70~100W Constant Current Mode LED Driver ELG-100-C series
SPECIFICATION
MODEL
RATED CURRENT
RATED POWER
OUTPUT
CURRENT ADJ. RANGE
SET UP TIME Note.4
VOLTAGE RANGE Note.3
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT(Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
EMC IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER TEMPERATURE
OVER VOLTAGE
(Please refer to "STATIC CHARACTERISTIC" section)
47 ~ 63Hz
PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load≧≧≧
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
<0.75mA / 277VAC
Compliance to EN55015,EN61000-3-2 Class C (@ load 60%) ; EN61000-3-3≧;; GB17743 GB17625.1,
EAC TP TC 020; KC KN15 KN61547,
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
ENVIRONMENT
EMC EMISSION
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed
I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
CURRENT TOLERANCE
±5.0%
CONSTANT CURRENT REGION
Note.2
TOTAL HARMONIC DISTORTION
OPEN CIRCUIT VOLTAGE
(max.)
Adjustable for A/AB-Type only (via built-in potentiometer)
COLD START 40A(twidth= s measured at 50% Ipeak)/230VAC760 Per NEMA 410μ;
MAX. No. of PSUs on 16A
CIRCUIT BREAKER 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
Tcase=-40 ~ +90 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)℃
MAX. CASE TEMP. Tcase=+90℃
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level ( )surge immunity Line-Earth 6KV, Line-Line 4KV ;
EAC TP TC 020; KC KN15 KN61547,
UL8750 independent, EN62384(type”HL”), CSA C22.2 No. 250.13-12; ;EN/AS/NZS 61347-1, EN/AS/NZS 61347-2-13
1. All parameters NOT specially mentioned are measured at 230VAC input, rated and 25 of ambient temperature.current ℃
2. Please refer to "DRIVING METHODS OF LED MODULE". For DA-Type, Constant Current region is 60%~100% of maximum voltage
under rated power delivery.
3. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
4. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 80 or less.℃
7. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
8. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
9. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
CURRENT RIPPLE 5.0% max. @rated current
100 ~ 305VAC 142 ~ 431VDC continue,320VAC for 24Hrs; 360VAC for 1Hr
ELG-100-C1050
48 ~ 95V
1050mA
99.75W
100 ~ 200V
ELG-100-C500
500mA
100W
ELG-100-C1400
35 ~ 72V
1400mA
100.8W
143 ~ 286V
ELG-100-C350 ELG-100-C700
350mA
100.1W
71 ~ 143V
700mA
100.1W
105V
210V 75V
297V 149V
525 ~ 1050mA
250 ~ 500mA 700 ~ 1400mA
175 ~ 350mA 350 ~ 700mA
90%
91% 90%
92% 90%
1.1A / 115VAC 0.6A / 230VAC 0.5A/277VAC
110 ~ 130V
222 ~ 242V 79 ~ 95V
305 ~ 333V 154 ~ 174V
199 63* *35.5 mm (L*W*H)
0.85kg; 16pcs/14.2kg/0.72CUFT
EAC TP TC 004 BIS IS15885(for 700A,1050A only); ; IP65 or IP67;; GB19510.1 GB19510.14,
approvedKC61347 1 KC61347 2 13-, --
THD< 20%(@load 50%/115VC; @load 60%/230VAC; @load 75%/277VAC)≧≧ ≧
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
1000ms/115VAC 500ms/230VAC
No load power consumption <0.5W for Blank / A / Dx / D2-Type
NO LOAD / STANDBY
POWER CONSUMPTION Standby power consumption <0.5W for B / AB / DA-Type
DALI STANDARDS Compliance to IEC62386-101, 102, 207 for DA-Type only
1087.5K hrs min. Telcordia SR-332 (Bellcore) 300.6Khrs min. MIL-HDBK-217F (25 )℃
70W
70W 70W 70.35W 70W
200VAC ~ 305VAC
100VAC ~ 180VAC
File Name:ELG-100-C-SPEC 2018-09-30