Notice for TAIYO YUDEN products Please read this notice before using the TAIYO YUDEN products. REMINDERS Product information in this catalog is as of October 2011. All of the contents specified herein are subject to change without notice due to technical improvements, etc. Therefore, please check for the latest information carefully before practical application or usage of the Products. Please note that Taiyo Yuden Co., Ltd. shall not be responsible for any defects in products or equipment incorporating such products, which are caused under the conditions other than those specified in this catalog or individual specification. Please contact Taiyo Yuden Co., Ltd. for further details of product specifications as the individual specification is available. Please conduct validation and verification of products in actual condition of mounting and operating environment before commercial shipment of the equipment. All electronic components or functional modules listed in this catalog are developed, designed and intended for use in general electronics equipment.(for AV, office automation, household, office supply, information service, telecommunications, (such as mobile phone or PC) etc.). Before incorporating the components or devices into any equipment in the field such as transportation,( automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network (telephone exchange, base station) etc. which may have direct influence to harm or injure a human body, please contact Taiyo Yuden Co., Ltd. for more detail in advance. Do not incorporate the products into any equipment in fields such as aerospace, aviation, nuclear control, submarine system, military, etc. where higher safety and reliability are especially required. In addition, even electronic components or functional modules that are used for the general electronic equipment, if the equipment or the electric circuit require high safety or reliability function or performances, a sufficient reliability evaluation check for safety shall be performed before commercial shipment and moreover, due consideration to install a protective circuit is strongly recommended at customer's design stage. The contents of this catalog are applicable to the products which are purchased from our sales offices or distributors (so called"TAIYO YUDEN' s official sales channel"). It is only applicable to the products purchased from any of TAIYO YUDEN's official sales channel. Please note that Taiyo Yuden Co., Ltd. shall have no responsibility for any controversies or disputes that may occur in connection with a third party's intellectual property rights and other related rights arising from your usage of products in this catalog. Taiyo Yuden Co., Ltd. grants no license for such rights. Caution for export Certain items in this catalog may require specific procedures for export according to"Foreign Exchange and Foreign Trade Control Law"of Japan,"U.S. Export Administration Regulations", and other applicable regulations. Should you have any question or inquiry on this matter, please contact our sales staff. 12 notice_e-01 SMD POWER INDUCTORS (NR SERIES/NR SERIES H TYPE/S TYPE/V TYPE) REFLOW FEATURES APPLICATIONS Small and Low profile inductor. For small DC/DC converter (cellular Phone, HDD, DVC, DSC, PDA, LCD display etc). It corresponds to High current. Simple and original magnetic shield structure. OPERATING TEMP. Durable structure against dropping impact. NR/NRS20/NRV20/NRH24/NRH30/NRV3012 : 25120Including self-generated heat NRS40/50/60/80 : 25125Including self-generated heat ORDERING CODE R 4 N 0 1 T 1 8 Type NR NRH NRS NRV T Blank Space Nominal inductance H Inductance tolerance M 20% N 30% example 2R2 100 101 Blank Space 2012 2410 2412 3010 3012 4010 4012 4018 5010 5012 5014 M 0 Packaging Tape & Reel Coating resin specification 0 Internal code 2.2 10 100 Rdecimal point External dimensions (WxLxH) 4.9x4.9x2.0 mm 2.0x2.0x1.2 mm 5020 4.9x4.9x2.4 mm 2.4x2.4x1.0 mm 5024 4.9x4.9x4.0 mm 2.4x2.4x1.2 mm 5040 6.0x6.0x1.0 mm 3.0x3.0x1.0 mm 6010 6.0x6.0x1.2 mm 3.0x3.0x1.2 mm 6012 6.0x6.0x1.4 mm 4.0x4.0x1.0 mm 6014 6.0x6.0x2.0 mm 4.0x4.0x1.2 mm 6020 6.0x6.0x2.8 mm 4.0x4.0x1.8 mm 6028 6.0x6.0x4.5 mm 4.9x4.9x1.0 mm 6045 8.0x8.0x3.0 mm 4.9x4.9x1.2 mm 8030 8.0x8.0x4.0 mm 4.9x4.9x1.4 mm 8040 EXTERNAL DIMENSIONS/STANDARD QUANTITY H L l H L W f f W e e Type NRS2012 NRV2012 NRH2410 NRH2412 e e Standard Quantity [pcs] Tape & Reel Type 2.00.1 2.00.1 1.2 max 0.50.2 1.250.2 (0.0790.004) (0.0790.004) 0.047 max 0.0200.0080.0500.008 2500 NRS5010 1.0 max 2.40.1 2.40.1 0.039 max 0.60.2 1.450.2 (0.0950.004) 0.0950.004 1.2 max 0.0240.0080.0570.008 0.047 max 2500 L W H e f NR 3010 1.0 max 0.039 max NRH3010 NR3012 3.00.1 0.90.2 3.00.1 1.90.2 1.2 max NRH3012 0.1180.004 0.1180.004 0.047 max0.0350.0080.0750.008 NRV3012 1.5 max NR 3015 0.059 max 1.0 max NR 4010 0.039 max NRS4010 1.2 max NR 4012 1.10.2 4.00.2 4.00.2 2.50.2 NRS4012 0.1570.008 0.1570.008 0.047 max0.0430.0080.0980.008 NR 4018 NRS4018 1.8 max 0.071 max *10R96R8 Type *2100101 Type NRS5014 NRS5020 2000 2000 2000 NRS5024 NR 5040 NRS5040 W H e f Standard Quantity [pcs] Tape & Reel l 1.0 max 0.039 max 1.2 max 0.047 max 1.4 max 0.055 max 4.90.2 4.90.2 3.30.2 1.3typ 1.20.2 2.0 max 0.1930.0080.1930.008 0.079 max 0.0470.0080.1300.008 0.051typ 2.4 max 0.094 max 3 * 4.1max 0.161max *4 4.0max 0.157max 1.0 max 0.039 max 1000 1000 1000 800 2500 1500 5000 NRS6010 4500 NR 6012 NRS6012 1.2 max 0.047 max 1000 NRS6014 1.4 max 0.055 max 1000 3500 3.0max 0.118max 1 8.00.2 8.00.2 1.600.3 5.60.3 NR 8040 * 4.2max 0.3150.0080.3150.0080.165max0.0630.012 0.220.012 2 * 4.0max NRS8040 0.157max NRS8030 NRS5012 L 1000 1000 Unitmminch 1.350.2 6.00.2 4.00.2 2.3typ 6.00.2 NR 6020 0.2360.0080.2360.008 2.0 max 0.0530.0080.1570.008 0.091typ 0.079 max NRS6020 NR 6028 2.8 max 0.110 max NRS6028 NR 6045 4.5 max 0.177 max NRS6045 *31R5100Type *4150470Type Unit : 1000 2500 2000 1500 mm (inch) This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 50 12 wound04_e-01 Recommended Land Patterns NRS5010, NRS5012, NRS5014, NRS6010, NRS6012, NRS6014, NRS4010, NRS4012, NRS4018 NRS5020, NRS5024, NRS5040 NRS6020, NRS6028, NRS6045 NRS2012, NRV2012 NRH2410, NRH2412NRH3010, NRH3012, NRV3012 1.35 1.45 2.2 2.0 2.8 2.0 3.6 0.7 0.8 0.65 0.65 5.6 2.7 3.7 0.7 NRS8030, NRS8040 4.7 4.0 0.8 1.2 1.2 1.5 1.5 5.7 1.6 7.5 1.6 1.8 NR4010, NR4012, NR4018 NR3010, NR3012, NR3015 NR5040 2.8 2.2 NR6012,NR6020,NR6028,NR6045 3.6 1.8 NR8040 5.6 4.7 2.7 3.7 4.0 0.8 1.2 1.2 1.5 5.7 7.5 1.5 1.6 1.6 1.8 AVAILABLE INDUCTANCE RANGE InductanceH Range Type NRS2012 NRV2012 NRH2410 NRH2412 NRH3010 NRH3012 1.8 NRV3012 NRS4010 Imax [mA] Rdc20 Imax [mA] Rdc20 Imax [mA] Rdc20 Imax [mA] Rdc20 Imax [mA] Rdc20 Imax [mA] Rdc20 Imax [mA] Rdc20 Imax [mA] 0.68 1700 1.0 0.070 1650 0.073 1570 0.060 1300 0.077 1480 0.065 1710 0.048 1600 0.065 1900 0.056 0.241 750 0.325 0.350 720 0.770 0.270 550 0.470 620 0.300 450 0.570 4.7 910 650 450 10 0.300 0.690 450 300 22 Rdc20 0.600 600 380 1.47 500 0.630 100 InductanceH Range Type NRS4012 NRS4018 NRS5010 NRS5012 NRS5014 NRS5020 NRS5024 POWER INDUCTORS INDUCTORS 0.8 NRS5040 Imax [mA] Rdc20 Imax [mA] Rdc20 Imax [mA] Rdc20 Imax [mA] Rdc20 Imax [mA] Rdc20 Imax [mA] Rdc20 Imax [mA] Rdc30 Imax [mA] Rdc30 0.68 2200 1.0 0.042 3200 0.027 1750 0.070 2300 0.053 2800 0.045 3600 0.021 4400 0.016 4500 0.017 0.170 1200 0.150 850 0.250 850 640 0.420 1050 0.670 0.200 1300 0.120 1200 0.125 2100 0.056 0.260 630 0.370 4.7 10 22 800 500 0.400 550 0.460 450 0.600 900 900 0.31 100 InductanceH Range Type 1.0 NRS6010 NRS6012 Rdc20 Imax [mA] Rdc20 Imax [mA] 1900 0.090 1800 0.090 2750 0.042 4100 0.270 1000 0.200 1800 NRS6028 NRS6045 Rdc20 Imax [mA] Rdc30 Imax [mA] 4600 0.013 4500 NRS8030 Rdc30 Imax [mA] NRS8040 Rdc30 Imax [mA] 0.014 0.020 6200 Rdc30 7800 0.006 0.009 4.7 10 1000 22 700 Type NR 3010 0.8 1300 1.0 3.3 10 47 950 0.580 320 IMAX [mA] InductanceH NRS6020 Rdc20 Imax [mA] 100 Range NRS6014 Imax [mA] NR 3012 0.140 1500 0.125 1900 0.300 950 0.290 1.670 NR 3015 650 NR 4010 NR 4012 Rdc20 IMAX [mA] Rdc20 IMAX [mA] Rdc20 IMAX [mA] Rdc20 IMAX [mA] 0.065 1490 0.05 2100 0.030 1050 0.100 1500 0.060 1830 NR 5040 Rdc20 IMAX [mA] 0.450 540 0.290 700 0.230 560 0.380 740 220 2.05 250 1.45 300 1.34 240 1.81 350 0.240 840 0.180 2100 1.00 900 170 0.046 2400 0.033 3100 0.034 1100 0.170 2200 0.066 0.600 750 0.466 NR 6012 Rdc30 IMAX [mA] NR 6020 Rdc20 IMAX [mA] 3800 0.030 3600 500 100 220 NR 4018 Rdc20 IMAX [mA] 0.065 2400 0.020 1730 0.056 1000 0.235 1400 950 320 NR 6045 Rdc30 IMAX [mA] 0.125 1900 0.013 NR 8040 Rdc30 IMAX [mA] Rdc30 7800 0.006 0.065 2500 0.047 3100 0.034 0.600 700 0.500 1000 0.290 4200 0.014 0.090 0.310 4.00 NR 6028 Rdc20 IMAX [mA] 0.020 4600 2.18 0.290 620 This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. wound04_e-01 12 51 PART NUMBERS NRS2012 Shielded type Ordering code NRS2012T NRS2012T NRS2012T NRS2012T NRS2012T 1R0N GJ 1R5N GJ 2R2M GJ 3R3M GJ 4R7M GJ EHS (Environmental Hazardous Substances) Inductance [H] RoHS RoHS RoHS RoHS RoHS 1.0 1.5 2.2 3.3 4.7 EHS (Environmental Hazardous Substances) Inductance [H] RoHS RoHS RoHS RoHS RoHS 1.0 1.5 2.2 3.3 4.7 EHS (Environmental Hazardous Substances) Inductance [H] RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 0.68 1.0 1.5 2.2 3.3 4.7 6.8 10 15 22 EHS (Environmental Hazardous Substances) Inductance [H] RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 1.5 2.2 3.3 4.7 6.8 10 EHS (Environmental Hazardous Substances) Inductance [H] RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.2 1.5 2.2 3.3 4.7 6.8 10 15 22 EHS (Environmental Hazardous Substances) Inductance [H] RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 1.5 2.2 3.3 4.7 6.8 10 15 22 Inductance Tolerance DC Resistance [] (20%) Rated current mA Temperature rise current Idc2 1,900 1,700 1,650 1,500 1,350 1,370 1,000 1,020 900 910 Saturation current Idc1 0.070 0.090 0.107 0.190 0.241 30 20 Measuring frequency kHz 100 NRV2012 type Ordering code NRV2012T NRV2012T NRV2012T NRV2012T NRV2012T 1R0N GF 1R5N GF 2R2M GF 3R3M GF 4R7M GF Inductance Tolerance DC Resistance [] (20%) Rated current mA Temperature rise current Idc2 2,200 1,650 1,800 1,400 1,600 1,200 1,250 900 1,100 750 Saturation current Idc1 0.073 0.100 0.129 0.227 0.325 30 20 Measuring frequency kHz 100 NRH2410 Shielded type Ordering code NRH2410T NRH2410T NRH2410T NRH2410T NRH2410T NRH2410T NRH2410T NRH2410T NRH2410T NRH2410T R68NN 4 1R0NN 4 1R5MN 2R2MN 3R3MN 4R7MN 6R8MN 100MN 150MN 220MN Inductance Tolerance 30 20 Self-resonant frequency MHz(min.) DC Resistance [] (20%) 120 106 94 77 56 50 43 32 27 22 0.060 0.070 0.110 0.150 0.220 0.290 0.410 0.690 1.02 1.47 Self-resonant frequency MHz(min.) DC Resistance [] (20%) 101 89 72 56 45 34 29 0.077 0.100 0.140 0.225 0.300 0.420 0.600 Self-resonant frequency MHz(min.) DC Resistance [] (20%) 120 99 86 64 50 44 34 25 22 0.065 0.075 0.083 0.130 0.170 0.250 0.350 0.550 0.770 Self-resonant frequency MHz(min.) DC Resistance [] (20%) 111 95 78 61 50 43 32 26 22 0.048 0.055 0.075 0.100 0.130 0.190 0.270 0.450 0.630 Rated current mA Temperature rise Saturation current current Idc1 Idc2 2,200 1,570 1,800 1,410 1,550 1,160 1,290 970 1,000 770 880 670 750 570 550 450 470 370 390 300 Measuring frequency kHz 100 NRH2412 Shielded type Ordering code NRH2412T NRH2412T NRH2412T NRH2412T NRH2412T NRH2412T NRH2412T 1R0NNGH 1R5NNGH 2R2MNGH 3R3MNGH 4R7MNGH 6R8MNGH 100MNGH Inductance Tolerance 30 20 Rated current mA Temperature rise Saturation current current Idc1 Idc2 2,350 1,300 2,100 1,150 1,700 1,000 1,400 750 1,150 650 950 550 810 450 Measuring frequency kHz 100 NRH3010 Shielded type Ordering code NRH3010T NRH3010T NRH3010T NRH3010T NRH3010T NRH3010T NRH3010T NRH3010T NRH3010T 1R2NN 1R5NN 2R2M 3R3MN 4R7MN 6R8MN 100M 150MN 220MN Inductance Tolerance 30 20 Rated current mA Temperature rise Saturation current current Idc1 Idc2 1,700 1,480 1,440 1,370 1,300 1,300 1,000 1,030 850 900 700 745 600 620 450 480 380 410 Measuring frequency kHz 100 NRH3012 Shielded type Ordering code NRH3012T NRH3012T NRH3012T NRH3012T NRH3012T NRH3012T NRH3012T NRH3012T NRH3012T 1R0NN 1R5NN 2R2MN 3R3MN 4R7MN 6R8MN 100MN 150MN 220MN Inductance Tolerance 30 20 Rated current mA Temperature rise Saturation current current Idc1 Idc2 2,200 1,710 1,700 1,600 1,500 1,370 1,200 1,210 1,000 1,060 850 890 730 720 530 570 500 500 Measuring frequency kHz 100 The saturation current value (Idc1) is the DC current value having inductance decrease down to 30%. (at 20) The temperature rise current value Idc2) is the DC current value having temperature increase up to 40. (at 20) The rated current is the DC current value that satisfies both of current value saturation current value and temperature rise current value. This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 52 12 wound04_e-01 PART NUMBERS NRV3012 type Self-resonant frequency MHz(min.) DC Resistance [] (20%) 110 92 70 55 48 40 32 0.065 0.075 0.120 0.150 0.190 0.300 0.470 Inductance Tolerance Self-resonant frequency MHz(min.) DC Resistance [] (20%) 1.0 2.2 3.3 4.7 6.8 10 15 22 30% 116 73 58 47 38 31 24 19 0.056 0.085 0.100 0.140 0.200 0.300 0.430 0.570 EHS (Environmental Hazardous Substances) Inductance [H] Inductance Tolerance Self-resonant frequency MHz(min.) DC Resistance [] (20%) RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 2.2 3.3 4.7 6.8 10 15 22 30% 100 70 60 45 35 30 24 18 0.042 0.060 0.070 0.095 0.125 0.170 0.260 0.400 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] Inductance Tolerance Self-resonant frequency MHz(min.) DC Resistance [] (20%) NRS4018T 1R0NDGJ NRS4018T 2R2MDGJ NRS4018T 3R3MDGJ NRS4018T 4R7MDGJ NRS4018T 6R8MDGJ NRS4018T 100MDGJ NRS4018T 150MDGJ NRS4018T 220MDGJ NRS4018T 330MDGJ RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 2.2 3.3 4.7 6.8 10 15 22 33 30% 90 60 45 35 30 25 18 15 12 0.027 0.042 0.055 0.070 0.098 0.150 0.210 0.290 0.460 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] Inductance Tolerance Self-resonant frequency MHz(min.) DC Resistance [] (20%) NRS5010T 1R0NMGF NRS5010T 2R2NMGF NRS5010T 3R3MMGF NRS5010T 4R7MMGF NRS5010T 6R8MMGF NRS5010T 100MMGF NRS5010T 150MMGF NRS5010T 220MMGF RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 2.2 3.3 4.7 6.8 10 15 22 95 65 42 37 33 23 19 15 0.070 0.105 0.125 0.145 0.185 0.250 0.400 0.600 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] Self-resonant frequency MHz(min.) DC Resistance [] (20%) NRS5012T 1R0NMGF NRS5012T 1R5NMGF NRS5012T 2R2MMGF NRS5012T 3R3MMGF NRS5012T 4R7MMGF NRS5012T 6R8MMGF NRS5012T 100MMGF NRS5012T 150MMGF RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 1.5 2.2 3.3 4.7 6.8 10 15 100 86 70 48 40 36 26 22 0.053 0.070 0.085 0.160 0.180 0.260 0.420 0.670 EHS (Environmental Hazardous Substances) Inductance [H] RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 1.5 2.2 3.3 4.7 6.8 10 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NRS4010T 1R0NDGG NRS4010T 2R2MDGG NRS4010T 3R3MDGG NRS4010T 4R7MDGG NRS4010T 6R8MDGG NRS4010T 100MDGG NRS4010T 150MDGG NRS4010T 220MDGG RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS Ordering code NRS4012T 1R0NDGG NRS4012T 2R2MDGJ NRS4012T 3R3MDGJ NRS4012T 4R7MDGJ NRS4012T 6R8MDGJ NRS4012T 100MDGJ NRS4012T 150MDGJ NRS4012T 220MDGJ Ordering code NRV3012T NRV3012T NRV3012T NRV3012T NRV3012T NRV3012T NRV3012T 1R0N 1R5N 2R2M 3R3M 4R7M 6R8M 100M Inductance Tolerance 30% 20% Rated current mA Temperature rise Saturation current current Idc1 Idc2 2,500 1,600 2,100 1,400 1,800 1,100 1,600 1,000 1,250 850 950 650 800 550 Measuring frequency kHz 100 NRS4010 Shielded type Measuring frequency kHz 100 NRS4012 Shielded type 20% Rated current mA Temperature rise Saturation current current Idc1 Idc2 2,800 2,200 1,650 1,900 1,400 1,700 1,200 1,500 900 1,300 800 1,100 650 750 500 620 Measuring frequency kHz 100 NRS4018 Shielded type 20% Rated current mA Temperature rise Saturation current current Idc1 Idc2 4,000 3,200 3,000 2,200 2,300 2,000 2,000 1,700 1,600 1,450 1,300 1,200 1100 850 900 720 700 550 POWER INDUCTORS INDUCTORS 20% Rated current mA Temperature rise Saturation current current Idc1 Idc2 2,000 1,900 1,200 1,500 1,100 1,400 950 1,200 800 1,000 620 750 540 600 450 500 Measuring frequency kHz 100 NRS5010 type 30% 20% Rated current mA Temperature rise Saturation current current Idc1 Idc2 2,350 1,750 1,500 1,400 1,400 1,250 1,200 1,150 1,000 1,000 850 900 680 650 550 450 Measuring frequency kHz 100 NRS5012 type Inductance Tolerance 30% 20% Rated current mA Temperature rise Saturation current current Idc1 Idc2 4,500 2,300 3,800 2,200 3,100 2,000 2,400 1,450 2,200 1,400 1,700 1,100 1,400 850 1,200 640 Measuring frequency kHz 100 The saturation current value (Idc1) is the DC current value having inductance decrease down to 30%. (at 20) The temperature rise current value Idc2) is the DC current value having temperature increase up to 40. (at 20) The rated current is the DC current value that satisfies both of current value saturation current value and temperature rise current value. This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. wound04_e-01 12 53 PART NUMBERS NRS5014 Shielded type Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NRS5014T 1R2NMGG NRS5014T 2R2NMGG NRS5014T 3R3NMGG NRS5014T 4R7NMGG NRS5014T 6R8MMGG NRS5014T 100MMGG RoHS RoHS RoHS RoHS RoHS RoHS 1.2 2.2 3.3 4.7 6.8 10 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NRS5020T 1R0NMGJ NRS5020T 1R5NMGJ NRS5020T 2R2NMGJ NRS5020T 3R3NMGJ NRS5020T 4R7MMGJ NRS5020T 6R8MMGJ NRS5020T 100MMGJ NRS5020T 150MMGJ NRS5020T 220MMGJ RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 1.5 2.2 3.3 4.7 6.8 10 15 22 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NRS5024T 1R0NMGJ NRS5024T 1R5NMGJ NRS5024T 2R2NMGJ NRS5024T 3R3NMGJ NRS5024T 4R7MMGJ NRS5024T 6R8MMGJ NRS5024T 100MMGJ NRS5024T 150MMGJ NRS5024T 220MMGJ NRS5024T 330MMGJ RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 1.5 2.2 3.3 4.7 6.8 10 15 22 33 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NRS5040T 1R5NMGJ NRS5040T 2R2NMGJ NRS5040T 3R3NMGJ NRS5040T 4R7NMGK NRS5040T 6R8MMGJ NRS5040T 100MMGJ NRS5040T 150MMGJ NRS5040T 220MMGK NRS5040T 330MMGJ NRS5040T 470MMGJ RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.5 2.2 3.3 4.7 6.8 10 15 22 33 47 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NRS6010T 1R5MMGF NRS6010T 2R2MMGF NRS6010T 3R3MMGF NRS6010T 4R7MMGF NRS6010T 6R8MMGF NRS6010T 100MMGF NRS6010T 220MMGF RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.5 2.2 3.3 4.7 6.8 10 22 Self-resonant frequency MHz(min.) DC Resistance [] (20%) 86 56 48 41 33 27 0.045 0.065 0.080 0.100 0.150 0.200 Self-resonant frequency MHz(min.) DC Resistance [] (20%) 81 68 57 46 37 30 24 20 17 0.021 0.026 0.035 0.048 0.060 0.090 0.120 0.165 0.260 Self-resonant frequency MHz(min.) DC Resistance [] (20%) 85 67 51 41 37 28 21 18 15 11 0.016 0.022 0.029 0.043 0.055 0.080 0.125 0.170 0.230 0.370 Self-resonant frequency MHz(min.) DC Resistance [] (20%) 60 42 32 28 21 18 13 9 7 6 0.017 0.022 0.027 0.029 0.049 0.056 0.080 0.126 0.180 0.310 Inductance Tolerance Self-resonant frequency MHz(min.) DC Resistance [] (20%) 20% 77 56 42 36 30 25 12 0.090 0.110 0.135 0.165 0.220 0.270 0.580 Inductance Tolerance 30% 20 Rated current mA Temperature rise Saturation current current Idc1 Idc2 3,800 2,400 2,800 2,000 2,350 1,700 2,050 1,400 1600 1,200 1400 1,050 Measuring frequency kHz 100 NRS5020 Shielded type Inductance Tolerance 30% 20% Rated current mA Temperature rise Saturation current current Idc1 Idc2 4,000 3,600 3,350 3,200 2,900 2,900 2,400 2,400 2,000 2,000 1,600 1,650 1,300 1,450 1,100 1,200 900 1,000 Measuring frequency kHz 100 NRS5024 Shielded type Inductance Tolerance 30% 20% Rated current mA Temperature rise Saturation current current Idc1 Idc2 5,800 4,400 5,200 3,600 4,100 3,100 3,100 2,400 2,700 2,000 2,200 1,600 1,700 1,200 1,400 1,000 1,200 820 1,000 630 Measuring frequency kHz 100 NRS5040 Shielded type Inductance Tolerance 30% 20% Rated current mA Temperature rise Saturation current current Idc1 Idc2 6,400 4,500 5,000 3,700 4,000 3,300 3,300 3,100 2,800 2,400 2,300 2,100 2,000 1,800 1,500 1,400 1,300 1,200 1,100 900 Measuring frequency kHz 100 NRS6010 type Rated current mA Temperature rise Saturation current current Idc1 Idc2 2,400 1,900 1,900 1,700 1,600 1,500 1,300 1,400 1,200 1,200 1,000 1,100 650 700 Measuring frequency kHz 100 The saturation current value (Idc1) is the DC current value having inductance decrease down to 30%. (at 20) The temperature rise current value Idc2) is the DC current value having temperature increase up to 40. (at 20) The rated current is the DC current value that satisfies both of current value saturation current value and temperature rise current value. This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 54 12 wound04_e-01 PART NUMBERS NRS6012 Shielded type EHS (Environmental Hazardous Substances) Inductance [H] NRS6012T 2R5NMGG NRS6012T 3R3NMGG NRS6012T 4R7MMGG NRS6012T 5R3MMGJ NRS6012T 6R8MMGJ NRS6012T 100MMGJ NRS6012T 150MMGJ NRS6012T 220MMGJ NRS6012T 330MMGJ NRS6012T 470MMGJ NRS6012T 680MMGJ NRS6012T 101MMGJ RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 2.5 3.3 4.7 5.3 6.8 10 15 22 33 47 68 100 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NRS6014T 1R2NMGG NRS6014T 2R2NMGG NRS6014T 3R3MMGG NRS6014T 4R7MMGG NRS6014T 6R8MMGG NRS6014T 100MMGG NRS6014T 150MMGG NRS6014T 220MMGG RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.2 2.2 3.3 4.7 6.8 10 15 22 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NRS6020T 0R8NMGG NRS6020T 1R5NMGJ NRS6020T 2R2NMGJ NRS6020T 3R3NMGJ NRS6020T 4R7NMGJ NRS6020T 6R8NMGJ NRS6020T 100MMGG NRS6020T 220MMGG RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 0.8 1.5 2.2 3.3 4.7 6.8 10 22 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NRS6028T 0R9NMGJ NRS6028T 1R5NMGJ NRS6028T 2R2NMGJ NRS6028T 3R0NMGJ NRS6028T 4R7MMGK NRS6028T 6R0MMGK NRS6028T 100MMGK NRS6028T 150MMGJ NRS6028T 220MMGJ NRS6028T 330MMGJ NRS6028T 470MMGJ NRS6028T 680MMGJ NRS6028T 101MMGJ RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 0.9 1.5 2.2 3.0 4.7 6.0 10 15 22 33 47 68 100 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NRS6045T 1R0NMGK NRS6045T 1R3NMGK NRS6045T 1R8NMGK NRS6045T 2R3NMGK NRS6045T 3R0NMGK NRS6045T 4R5MMGK NRS6045T 6R3MMGK NRS6045T 100MMGK NRS6045T 150MMGK NRS6045T 220MMGK NRS6045T 330MMGK NRS6045T 470MMGK NRS6045T 680MMGK NRS6045T 101MMGK RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 1.3 1.8 2.3 3.0 4.5 6.3 10 15 22 33 47 68 100 Inductance Tolerance 30 20 Self-resonant frequency MHz(min.) DC Resistance [] (20%) 45 42 36 34 30 22 18 12 8 6 3 1 0.090 0.105 0.125 0.125 0.165 0.200 0.295 0.465 0.580 0.965 1.160 1.670 Self-resonant frequency MHz(min.) DC Resistance [] (20%) 77 61 41 36 30 24 20 16 0.042 0.055 0.075 0.090 0.115 0.140 0.210 0.300 Self-resonant frequency MHz(min.) DC Resistance [] (20%) 110 93 73 55 43 30 18 11 0.020 0.026 0.034 0.040 0.058 0.085 0.125 0.290 Self-resonant frequency MHz(min.) DC Resistance [] (30%) 90 78 68 55 39 30 20 17 12 10 8 5 3 0.013 0.016 0.020 0.023 0.031 0.040 0.065 0.095 0.135 0.220 0.300 0.420 0.600 Self-resonant frequency MHz(min.) DC Resistance [] (30%) 110 95 80 60 45 25 15 12 10 7 6 5 4 3 0.014 0.016 0.019 0.022 0.024 0.030 0.036 0.046 0.070 0.107 0.141 0.211 0.304 0.466 Rated current mA Temperature rise Saturation current current Idc1 Idc2 2,100 1,800 1,800 1,700 1,600 1,550 1,500 1,550 1,300 1,350 1,000 1,200 800 800 760 650 590 550 520 460 440 410 350 320 Measuring frequency kHz 100 NRS6014 Shielded type Inductance Tolerance 30% 20% Rated current mA Temperature rise Saturation current current Idc1 Idc2 4,100 2,750 3,000 2,300 2,500 2,000 2,000 1,900 1,700 1,650 1,400 1,400 1,150 1,200 950 1,000 Measuring frequency kHz 100 NRS6020 Shielded type Inductance Tolerance 30% 20% Rated current mA Temperature rise Saturation current current Idc1 Idc2 6,400 4,100 4,300 3,600 3,200 2,900 2,800 2,750 2,400 2,150 2,000 1,800 1,900 1,500 1,250 950 Measuring frequency kHz POWER INDUCTORS INDUCTORS Ordering code 100 NRS6028 Shielded type Inductance Tolerance 30% 20% Rated current mA Temperature rise Saturation current current Idc1 Idc2 6,700 4,600 5,100 4,200 4,200 3,700 3,600 3,400 2,700 3,000 2,500 2,500 1,900 1,900 1,600 1,800 1,300 1,400 1,100 1,100 1,000 920 800 770 650 660 Measuring frequency kHz 100 NRS6045 Shielded type Inductance Tolerance 30% 20% Rated current mA Temperature rise Saturation current current Idc1 Idc2 9,800 4,500 8,200 4,200 7,200 3,900 6,400 3,600 5,600 3,300 4,400 3,100 3,600 3,000 3,100 2,400 2,500 1,900 2,000 1,600 1,650 1,400 1,400 1,150 1,100 950 900 750 Measuring frequency kHz 100 The saturation current value (Idc1) is the DC current value having inductance decrease down to 30%. (at 20) The temperature rise current value Idc2) is the DC current value having temperature increase up to 40. (at 20) The rated current is the DC current value that satisfies both of current value saturation current value and temperature rise current value. This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. wound04_e-01 12 55 PART NUMBERS NRS8030 Shielded type Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NRS8030T 1R0NJGJ NRS8030T 1R5NJGJ NRS8030T 2R2NJGJ NRS8030T 3R3MJGJ NRS8030T 4R7MJGJ NRS8030T 6R8MJGJ NRS8030T 100MJGJ NRS8030T 150MJGJ NRS8030T 220MJGJ NRS8030T 330MJGJ NRS8030T 470MJGJ RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 1.5 2.2 3.3 4.7 6.8 10 15 22 33 47 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NRS8040T 0R9NJGJ NRS8040T 1R4NJGJ NRS8040T 2R0NJGJ NRS8040T 3R6NJGJ NRS8040T 4R7NJGJ NRS8040T 6R8NJGJ NRS8040T 100MJGJ NRS8040T 150MJGJ NRS8040T 220MJGJ RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 0.9 1.4 2.0 3.6 4.7 6.8 10 15 22 Inductance Tolerance Self-resonant frequency MHz(min.) DC Resistance [] (30%) 120 80 60 50 40 32 27 20 16 13 11 0.009 0.012 0.015 0.019 0.022 0.029 0.033 0.060 0.070 0.120 0.170 Self-resonant frequency MHz(min.) DC Resistance [] (30%) 85 63 50 34 30 24 22 16 13 0.006 0.007 0.009 0.015 0.018 0.025 0.034 0.050 0.066 30% 20% Rated current mA Temperature rise Saturation current current Idc1 Idc2 7,800 6,200 6,200 5,300 4,900 4,800 4,300 4,200 3,600 4,000 3,000 3,400 2,400 3,000 2,000 2,200 1,750 1,900 1,300 1,500 1,100 1,300 Measuring frequency kHz 100 NRS8040 Shielded type Inductance Tolerance 30% 20% Rated current mA Temperature rise Saturation current current Idc1 Idc2 13,000 7,800 10,000 7,000 8,100 6,300 6,400 4,900 5,400 4,100 4,400 3,700 3,800 3,100 2,900 2,400 2,400 2,200 Measuring frequency kHz 100 NR 3010 Shielded type Ordering code NR NR NR NR NR NR NR NR NR NR NR 3010T 3010T 3010T 3010T 3010T 3010T 3010T 3010T 3010T 3010T 3010T 1R0N 1R5N 2R2M 3R3M 4R7M 6R8M 100M 150M 220M 330M 470M EHS (Environmental Hazardous Substances) Inductance [H] RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 1.5 2.2 3.3 4.7 6.8 10 15 22 33 47 EHS (Environmental Hazardous Substances) Inductance [H] RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 1.5 2.2 3.3 4.7 6.8 10 15 22 33 47 EHS (Environmental Hazardous Substances) Inductance [H] RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 1.5 2.2 3.3 4.7 6.8 10 15 22 33 47 Inductance Tolerance 30 20 Self-resonant frequency MHz(min.) DC Resistance [] (20) 126 98 82 63 56 46 35 30 25 20 17 0.065 0.080 0.095 0.140 0.190 0.300 0.450 0.740 1.03 1.55 2.05 Self-resonant frequency MHz(min.) DC Resistance [] (20) 110 92 70 55 48 40 32 27 22 19 17 0.050 0.060 0.080 0.100 0.130 0.190 0.290 0.450 0.630 1.03 1.45 Self-resonant frequency MHz(min.) DC Resistance [] (20) 100 87 64 49 40 36 28 23 20 18 17 0.030 0.040 0.060 0.080 0.120 0.160 0.230 0.360 0.520 0.840 1.34 mA Rated current Saturation current Temperature rise current Idc1 Idc2 1,300 1,400 1,200 1,300 1,100 1,100 940 870 780 750 630 610 510 500 400 400 350 350 275 260 235 220 Measuring frequency kHz mA Rated current Saturation current Temperature rise current Idc1 Idc2 1,500 1,490 1,360 1,400 1,200 1,100 1,050 910 980 770 740 670 630 540 485 440 420 375 330 310 280 250 Measuring frequency kHz mA Rated current Saturation current Temperature rise current Idc1 Idc2 2,100 2,100 1,800 1,820 1,500 1,480 1,230 1,210 1,040 1,020 880 870 710 700 560 560 470 470 370 390 300 320 Measuring frequency kHz 100 NR 3012 Shielded type Ordering code NR NR NR NR NR NR NR NR NR NR NR 3012T 3012T 3012T 3012T 3012T 3012T 3012T 3012T 3012T 3012T 3012T 1R0N 1R5N 2R2M 3R3M 4R7M 6R8M 100M 150M 220M 330M 470M Inductance Tolerance 30 20 100 NR 3015 Shielded type Ordering code NR NR NR NR NR NR NR NR NR NR NR 3015T 3015T 3015T 3015T 3015T 3015T 3015T 3015T 3015T 3015T 3015T 1R0N 1R5N 2R2M 3R3M 4R7M 6R8M 100M 150M 220M 330M 470M Inductance Tolerance 30 20 100 The saturation current value (Idc1) is the DC current value having inductance decrease down to 30%. (at 20) The temperature rise current value Idc2) is the DC current value having temperature increase up to 40. (at 20) The rated current is the DC current value that satisfies both of current value saturation current value and temperature rise current value. This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 56 12 wound04_e-01 PART NUMBERS NR 4010 Shielded type EHS (Environmental Hazardous Substances) Inductance [H] RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 2.2 3.3 4.7 6.8 10 15 22 33 47 EHS (Environmental Hazardous Substances) Inductance [H] Inductance Tolerance RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 2.2 3.3 4.7 6.8 10 15 22 33 47 30 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] Inductance Tolerance NR 4018T 1R0N NR 4018T 2R2M NR 4018T 3R3M NR 4018T 4R7M NR 4018T 6R8M NR 4018T 100M NR 4018T 150M NR 4018T 220M NR 4018T 330M NR 4018T 470M NR 4018T 680M NR 4018T 101M NR 4018T 151M NR 4018T 221M RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 2.2 3.3 4.7 6.8 10 15 22 33 47 68 100 150 220 30 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] Inductance Tolerance NR 5040T 1R5N NR 5040T 2R2N NR 5040T 3R3N NR 5040T 4R7N NR 5040T 6R8M NR 5040T 100M NR 5040T 150M NR 5040T 220M NR 5040T 330M NR 5040T 470M RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.5 2.2 3.3 4.7 6.8 10 15 22 33 47 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NR 6012T 2R5NE NR 6012T 4R0NE NR 6012T 5R3ME NR 6012T 6R8ME NR 6012T 100ME NR 6012T 150ME NR 6012T 220ME NR 6012T 330ME NR 6012T 470ME NR 6012T 680ME NR 6012T 101ME RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 2.5 4.0 5.3 6.8 10 15 22 33 47 68 100 Ordering code NR NR NR NR NR NR NR NR NR NR 4010T 4010T 4010T 4010T 4010T 4010T 4010T 4010T 4010T 4010T 1R0N 2R2N 3R3M 4R7M 6R8M 100M 150M 220M 330M 470M Inductance Tolerance 30 20 Self-resonant frequency MHz(min.) DC Resistance [] (20) 116 73 58 47 38 31 24 19 15 13 0.100 0.150 0.180 0.210 0.300 0.380 0.510 0.870 1.54 1.81 Self-resonant frequency MHz(min.) DC Resistance [] (20) 131 66 50 45 35 28 23 18 15 12 0.060 0.090 0.130 0.140 0.180 0.240 0.400 0.480 0.810 1.00 Self-resonant frequency MHz(min.) DC Resistance [] (20) 80 52 44 34 29 24 19 16 12 10 8.3 6.5 5.5 4.0 0.030 0.060 0.070 0.090 0.110 0.180 0.250 0.360 0.530 0.650 1.00 1.50 2.50 4.00 Self-resonant frequency MHz(min.) DC Resistance [] (30) 60 42 32 28 21 18 13 9 7 6 0.020 0.022 0.027 0.029 0.049 0.056 0.080 0.126 0.180 0.310 Self-resonant frequency MHz(min.) DC Resistance [] (20) 45 39 34 30 22 18 12 8 6 3 1 0.090 0.105 0.125 0.165 0.235 0.330 0.530 0.700 1.05 1.35 2.18 mA Rated current Saturation current Temperature rise current Idc1 Idc2 1,800 1,050 1,150 890 820 1,100 750 900 620 740 600 560 510 470 400 360 300 280 280 240 Measuring frequency kHz mA Rated current Saturation current Temperature rise current Idc1 Idc2 2,500 1,500 1,650 1,200 980 1,200 960 1,050 840 900 770 740 600 560 540 510 420 400 370 350 Measuring frequency kHz mA Rated current Saturation current Temperature rise current Idc2 Idc1 4,000 1,830 2,700 1,440 2,000 1,230 1,700 1,200 1,450 1,060 1,200 840 940 650 800 590 650 490 570 420 470 320 400 270 310 220 270 170 Measuring frequency kHz mA Rated current Saturation current Temperature rise current Idc2 Idc1 6,000 3,600 4,600 3,500 3,800 3,300 3,300 3,100 2,600 2,300 2,300 2,100 2,000 1,800 1,600 1,400 1,300 1,200 1,100 900 Measuring frequency kHz mA Rated current Saturation current Temperature rise current Idc1 Idc2 2,100 1,730 1,800 1,570 1,500 1,400 1,300 1,180 1,000 1,000 800 790 760 630 590 530 520 460 440 410 350 320 Measuring frequency kHz 100 NR 4012 Shielded type NR NR NR NR NR NR NR NR NR NR 4012T 4012T 4012T 4012T 4012T 4012T 4012T 4012T 4012T 4012T 1R0N 2R2M 3R3M 4R7M 6R8M 100M 150M 220M 330M 470M 20 100 NR 4018 Shielded type 20 POWER INDUCTORS INDUCTORS Ordering code 100 NR 5040 Shielded type 30 20 100 NR 6012 Shielded type Inductance Tolerance 30 20 100 The saturation current value (Idc1) is the DC current value having inductance decrease down to 30%. (at 20) The temperature rise current value Idc2) is the DC current value having temperature increase up to 40. (at 20) The rated current is the DC current value that satisfies both of current value saturation current value and temperature rise current value. This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. wound04_e-01 12 57 PART NUMBERS NR 6020 Shielded type Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NR 6020T 0R8N NR 6020T 1R5N NR 6020T 2R2N NR 6020T 3R3N NR 6020T 4R7N NR 6020T 6R8N NR 6020T 100M NR 6020T 220M RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 0.8 1.5 2.2 3.3 4.7 6.8 10 22 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NR 6028T 0R9N NR 6028T 1R5N NR 6028T 2R2N NR 6028T 3R0N NR 6028T 4R7M NR 6028T 6R0M NR 6028T 100M NR 6028T 150M NR 6028T 220M NR 6028T 330M NR 6028T 470M NR 6028T 680M NR 6028T 101M RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 0.9 1.5 2.2 3.0 4.7 6.0 10 15 22 33 47 68 100 Ordering code EHS (Environmental Hazardous Substances) Inductance [H] NR 6045T 1R0N NR 6045T 1R3N NR 6045T 1R8N NR 6045T 2R3N NR 6045T 3R0N NR 6045T 4R5M NR 6045T 6R3M NR 6045T 100M NR 6045T 150M NR 6045T 220M NR 6045T 330M NR 6045T 470M NR 6045T 680M NR 6045T 101M RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1.0 1.3 1.8 2.3 3.0 4.5 6.3 10 15 22 33 47 68 100 EHS (Environmental Hazardous Substances) Inductance [H] RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 0.9 1.4 2.0 3.6 4.7 6.8 10 15 22 33 47 68 100 Inductance Tolerance 30 20 Self-resonant frequency MHz(min.) DC Resistance [] (20) 110 93 73 55 43 30 18 11 0.020 0.026 0.034 0.040 0.058 0.085 0.125 0.290 Self-resonant frequency MHz(min.) DC Resistance [] (30) 90 78 68 55 39 30 20 17 12 10 8 5 3 0.013 0.016 0.020 0.023 0.031 0.040 0.065 0.095 0.135 0.220 0.300 0.420 0.600 Self-resonant frequency MHz(min.) DC Resistance [] (30) 110 95 80 60 45 25 15 12 10 7 6 5 4 3 0.014 0.016 0.018 0.021 0.024 0.031 0.038 0.047 0.077 0.115 0.145 0.220 0.330 0.500 Self-resonant frequency MHz(min.) DC Resistance [] (30) 85 63 50 34 30 24 22 16 13 12 8 7 6 0.006 0.007 0.009 0.015 0.018 0.025 0.034 0.050 0.066 0.100 0.150 0.230 0.290 mA Rated current Saturation current Temperature rise current Idc1 Idc2 5,500 3,800 4,000 3,200 3,200 2,700 2,800 2,600 2,400 2,000 2,000 1,800 1,700 1,400 1,050 950 Measuring frequency kHz mA Rated current Saturation current Temperature rise current Idc1 Idc2 6,600 4,600 5,000 4,200 4,200 3,700 3,600 3,400 2,700 3,000 2,500 2,500 1,900 1,900 1,600 1,800 1,300 1,400 1,100 1,100 950 920 760 770 620 660 Measuring frequency kHz mA Rated current Saturation current Temperature rise current Idc2 Idc1 8,500 4,200 8,000 4,000 7,000 3,700 6,000 3,500 5,000 3,200 4,000 3,000 3,800 2,800 3,000 2,500 2,300 1,900 1,900 1,500 1,500 1,400 1,300 1,100 1,000 900 800 700 Measuring frequency kHz mA Rated current Saturation current Temperature rise current Idc1 Idc2 11,000 7,800 9,000 7,000 7,400 6,300 5,300 4,900 4,700 4,100 4,000 3,700 3,400 3,100 2,700 2,400 2,200 2,200 1,900 1,700 1,500 1,400 1,200 1,100 1,000 1,000 Measuring frequency kHz 100 NR 6028 Shielded type Inductance Tolerance 30 20 100 NR 6045 Shielded type Inductance Tolerance 30 20 100 NR 8040 Shielded type Ordering code NR NR NR NR NR NR NR NR NR NR NR NR NR 8040T 8040T 8040T 8040T 8040T 8040T 8040T 8040T 8040T 8040T 8040T 8040T 8040T 0R9N 1R4N 2R0N 3R6N 4R7N 6R8N 100M 150M 220M 330M 470M 680M 101M Inductance Tolerance 30 20 100 The saturation current value (Idc1) is the DC current value having inductance decrease down to 30%. (at 20) The temperature rise current value Idc2) is the DC current value having temperature increase up to 40. (at 20) The rated current is the DC current value that satisfies both of current value saturation current value and temperature rise current value. This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 58 12 wound04_e-01 ELECTRICAL CHARACTERISTICS DC Bias characteristics Measured by HP4285A NRS2012 10 4R7M 4R7M 3R3M 220M 100M 2R2M 1R5N 1R0N 1R5N 1 1R0N 4R7M 2R2N 1R0N 1,000 0.1 10 10,000 DC Bias mA 100 2R2M 100 1,000 0.1 10 10,000 1R0N 4R7M 2R2M 1R0N 1 100 NRS4010 1,000 0.1 10 10,000 220M 100M 100M 10 10 2R2M 1R0N 1 InductanceH 4R7N InductanceH 4R7N 2R2M 1R0N 1,000 0.1 10 10,000 DC Bias mA 100 1,000 2R2M 0.1 10 10,000 1R0N 100 NRS5012 100 10,000 NRS5014 100 220M 1,000 DC Bias mA DC Bias mA NRS5010 100M 4R7N 1 1 100 10,000 100 220M 10 1,000 NRS4018 NRS4012 220M 100 DC Bias mA 100 NRS5020 100 100 220M 150M InductanceH 10 4R7M 2R2N 1R0N 0.1 100 1,000 DC Bias mA 10,000 10 4R7M 2R2M 1 1 100M 100M InductanceH 100M 0.1 10 1R0N 100 10 InductanceH InductanceH 10,000 10 DC Bias mA 100 InductanceH 1,000 DC Bias mA 100M 100M 2R2N DC Bias mA 10 100 NRV3012 4R7M 1 1 10 10 10,000 100 InductanceH InductanceH 10 4R7M 0.1 10 1,000 220M 100M 0.1 10 0.1 100 DC Bias mA 100 220M InductanceH 0.1 10 10,000 NRH3012 NRH3010 100 10 1,000 DC Bias mA 2R2M 1R0N POWER INDUCTORS INDUCTORS 100 4R7M 1 1 0.1 10 100M 10 10 InductanceH InductanceH InductanceH 100 3R3M 2R2M 1 NRH2412 NRH2410 100 InductanceH 10 NRV2012 4R7M 1R2N 1 1,000 DC Bias mA 10,000 0.1 10 100M 4R7M 2R2N 1R0N 1 100 1,000 DC Bias mA 10,000 0.1 10 100 1,000 10,000 DC Bias mA This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. wound04_e-01 12 59 ELECTRICAL CHARACTERISTICS DC Bias characteristics NRS5024 NRS5040 100 100 470M 220M 220M 100M 100M 10 InductanceH InductanceH 10 4R7M 2R2N 1R0N 4R7N 2R2N 1 1 0.1 0.1 10 100 1,000 10,000 10 100 DC Bias mA 1,000 10,000 DC Bias mA NRS6012 NRS6010 100 100 NRS6020 NRS6014 100 100 101M 470M 220M 100M 10 4R7M 2R2N 4R7N 2R5N 1 1 0.1 10 100 1,000 0.1 10 10,000 100 101M 100 InductanceH InductanceH 100M 4R7M 0R9N 100 10,000 0.1 10 2R2N 1 100 1,000 DC Bias mA 10,000 0.1 10 0R8N 100 1,000 10,000 DC Bias mA 101M 4R5M 2R3N 1 1,000 10,000 0.1 10 100,000 100M 1R0N 100 DC Bias mA 1,000 10,000 100,000 10,000 100,000 DC Bias mA NRS8030 1000 2R5N 4R7N 220M 10 2R2N 0.1 10 4R7N 470M 220M 1 10 NRS6045 1000 470M 10 1,000 DC Bias mA NRS6028 1000 100M 100M 1 DC Bias mA 100 10 InductanceH 100M InductanceH InductanceH 10 220M 220M InductanceH 220M NRS8040 100 220M 100 10 InductanceH InductanceH 470M 220M 10 100M 4R7M 2R2N 4R7N 2R0N 1 1 0.1 10 100M 0R9N 1R0N 100 1,000 DC Bias mA 10,000 100,000 0.1 10 100 1,000 DC Bias mA This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 60 12 wound04_e-01 ELECTRICAL CHARACTERISTICS DC Bias characteristics Measured by HP4285A NR 3010 NR 3012 220M 4R7M 10 220M 100M 100M 4R7M 2R2M 1,000 1 10 10,000 1,000 1 10 10,000 NR 4012 1,000 1 10 10,000 100 10,000 NR 6012 NR 5040 1000 1,000 DC Bias mA DC Bias mA NR 4018 100 2R2N 100 DC Bias mA 100M 4R7M 2R2M 100 DC Bias mA 10 1000 100 470M 470M 221M 470M 220M 10 100M 10 100 N 470M 220M 100M 10 5R3M 2R2N 2R2M 1,000 1 10 10,000 100 DC Bias mA 1,000 1 10 10,000 100 1,000 1 10 10,000 100 DC Bias mA DC Bias mA NR 6020 100 100M 4R7N 4R7M 2R2M Inductance H 100 Inductance H 100M 4R7M 1 10 101M 100 Inductance H Inductance H 10 220M 101M 220M 10,000 DC Bias mA NR 6045 NR 6028 NR 8040 1000 1000 1,000 POWER INDUCTORS INDUCTORS 100 220M 10 4R7M 2R2M 470M Inductance H 220M 100 470M Inductance H 470M 100M 1 10 100 470M 10 NR 4010 NR 3015 100 Inductance H Inductance H 100 1000 220M 101M 101M 2R2M 1 100 220M 220M 10 4R7 100M 10 4R5N 2R3N 2R2 10 100M 4R7N 2R0N N 1 0.1 10 470M 220M 100M 0R8N 101M 470M Inductance H 4R7M 100 470M Inductance H Inductance H Inductance H 10 100 100 100M 1,000 DC Bias mA 10,000 0.1 10 0R9 1 100 1,000 DC Bias mA 10,000 0.1 10 1R0N 1 100 1,000 DC Bias mA 10,000 100,000 0.1 10 0R9N 100 1,000 10,000 100,000 DC Bias mA This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. wound04_e-01 12 61 PACKAGING Minimum Quantity Embossed tape 12mm wide (0.47 inches wide) Tape Material 1.750.1 K 0.0690.004 T A 12.00.3 0.4720.012 NRS2012/NRV2012 NRH2410 NRH2412 NR 3010/NRH3010 NR 3012/NRH3012/NRV3012 NR 3015 NR 4010/NRS4010 NR 4012/NRS4012 NR 4018/NRS4018 NRS5010 NRS5012 NRS5014 NRS5020 NRS5024 NR 5040/NRS5040 NRS6010 NR 6012/NRS6012 NRS6014 NR 6020/NRS6020 NR 6028/NRS6028 NR 6045/NRS6045 NRS8030 NR 8040/NRS8040 CHIP cavity 0.1 1.50 0.004 0.0590 5.50.1 0.2170.004 Type B Standard Quantity [pcs] Tape Reel 2500 2500 2500 2000 2000 2000 5000 4500 3500 1000 1000 1000 800 2500 1500 1000 1000 1000 2500 2000 1500 1000 1000 Electrode bottom view F 2.00.1 4.00.1 0.0790.004 0.1570.004 Chip cavity Type A Insertion pitch B Tape thickness F T K NR 4010 NRS4010 4.30.1 4.30.1 NR 4012 NRS4012 0.1690.0040.1690.004 NR 4018 NRS4018 1.40.1 0.0550.004 1.60.1 0.0630.004 2.10.1 0.0830.004 1.40.1 NRS5010 0.30.1 0.0550.004 0.0120.004 1.40.1 NRS5012 0.0550.004 5.250.1 5.250.1 1.60.1 NRS5014 0.2070.0040.2070.004 0.0630.004 2.30.1 NRS5020 0.0910.004 8.00.1 2.70.1 NRS5024 0.3150.004 0.1060.004 5.150.1 5.150.1 4.20.1 NR 5040 NRS5040 0.2030.0040.2030.004 0.1650.004 1.40.1 NRS6010 0.0550.004 1.60.1 NR 6012 NRS6012 0.0630.004 0.40.1 1.60.1 NRS6014 0.0160.0040.0630.004 6.30.1 6.30.1 2.30.1 NR 6020 0.2480.0040.2480.004 NRS6020 0.0900.004 NR 6028 3.10.1 NRS6028 0.1220.004 4.70.1 NR 6045 NRS6045 0.1850.004 Unit : mm (inch) Embossed tape 16mm wide (0.63 inches wide) Embossed tape 8mm wide (0.315 inches wide) B A CHIP cavity K 1.750.1 0.0690.004 1.750.1 K 0.0690.004 T 16.00.3 0.6300.012 3.50.1 0.1380.004 0.059 F 1.50.1 0.0590.004 8.00.2 0.3150.008 CHIP cavity 1.5 0.1 0 0.004 0 2.00.1 0.0790.004 4.00.1 0.1570.004 F 2.00.05 4.00.1 0.0790.002 0.1570.004 7.50.1 0.2950.004 A Electrode bottom view Chip cavity Type T B Taping dimensions A B Electrode bottom view Insertion pitch F Tape thickness T K 3.40.1 8.30.1 8.30.1 12.00.1 0.50.1 0.1340.004 4.50.1 NR 8040 0.3270.0040.3270.0040.4720.0040.0200.004 NRS8040 0.1770.004 NRS8030 Chip cavity Insertion pitch F Tape thickness T K 0.250.05 1.30.1 0.0090.0020.0510.004 Type A B NRS2012 2.20.1 2.20.1 NRV2012 0.1020.0040.1020.004 NRH2410 2.60.1 2.60.1 0.250.05 1.30.1 0.0090.0020.0510.004 NRH2412 0.0870.0040.1020.004 NR 3010 1.40.1 4.00.1 NRH3010 0.0550.004 0.1570.004 NR 3012 3.20.1 3.20.1 0.30.05 1.60.1 NRH3012 0.1260.0040.1260.004 0.0120.0020.0630.004 NRV 3012 1.90.1 NR 3015 0.0750.004 Unit : mm (inch) Leader and Blank portion NR, NRH, NRS, NRV Chip cavity Blank portions Blank portions Leader Unit : mm (inch) 160mm or more (6.3 inches or more) 100mm or more (3.94 inches or more) 400mm or more (15.8 inches or more) Direction of tape feed This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. wound0405_pack-P1 12 wound0405_pack_e-01 PACKAGING Reel size W D d 20.5 130.5 2.5 or less 0.098inches or less D Reel size (Reference values) d W 1800.5 7.0870.019 601.0 2.360.04 10.01.5 0.3940.059 1803.0 7.0870.118 602.0 2.360.08 14.01.5 0.5510.059 Type NRS2012 NRV2012 NRH2410 NRH2412 NR 3010 NRH3010 NR 3012 NRH3012 NRV3012 NR 3015 NRS5010 NRS5012 NRS5014 NRS5020 NRS6010 NR 6012 NRS6012 NRS6014 Unit : mm (inch) W D d 20.5 130.5 t Type NR 4010 NRS4010 NR 4012 NRS4012 NR 4018 NRS4018 NRS5024 NR 5040 NRS5040 NR 6020 NRS6020 NR 6028 NRS6028 NR 6045 NRS6045 NRS8030 NR 8040 NRS8040 D Reel size (Reference values) d t (max.) 3303.0 802.0 12.990.118 3.150.078 W 18.5 0.72 13.51.0 0.5310.04 22.5 0.89 17.51.0 0.6890.04 Unit : mm (inch) Top Tape Strength The top tape requires a peel-off force of 0.1 to 1.3N in the direction of the arrow as illustrated below. 165 180 This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. wound0405_pack_e-01 12 wound0405_pack-P2 RELIABILITY DATA SMD inductor NR, NS series 1. Operating Temperature Range NR30/40/50/60/80, NRS20, NRV20/30, NRH24/30 Type NRS40/50/60/80 Type NR10050 Type NS101, NS125Type Test Method and Remarks Including self-generated heat 25120 25125 25105 40125 2. Storage Temperature Range NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type 4085 NR10050 Type NS101, NS125Type Test Method and Remarks NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type, NR10050 Type, NS101/125 Type : 5 to 40 for the product with taping. 3. Rated current NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type NR10050 Type NS101, NS125Type Within the specified tolerance 4. Inductance NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type Within the specified tolerance NR10050 Type NS101, NS125Type Test Method and Remarks LCR Meter : HP 4285A or equivalent, Measuring frequency : Specified frequency NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type, NS101/125 Type NR10050 Type : LCR Meter : LCR Meter : HP 4285A or equivalent, 100kHz, 1V : HP 4263A or equivalent, 100kHz, 1V 5. DC Resistance NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type Within the specified tolerance NR10050 Type NS101, NS125Type Test Method and Remarks DC ohmmeter : HIOKI 3227 or equivalent 6. Self resonance frequency NR30/40/50/60/80, NRV30, NRH24/30, NRS40/50/60/80 Type Within the specification NR10050 Type NS101, NS125Type Test Method and Remarks NR30/40/50/60/80, NRV30, NRH24/30, NRS40/50/60/80Type, NR10050 Type, NS101/125 Type : Inpedance analyzer/material analyzer : HP4291A or equivalent HP4191A, 4192A or equivalent 7. Temperature characteristic NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type Inductance change : Within 20% NR10050 Type NS101, NS125Type Inductance change : Within 15% Test Method and Remarks NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type, NR10050 Type : Measurement of inductance shall be taken at temperature range within 2585. With reference to inductance value at 20., change rate shall be calculated. NS101, NS125 Type : Measurement of inductance shall be taken at temperature range within 40125. With reference to inductance value at 20., change rate shall be calculated. Change of maximum inductance deviation in step 1 to 5 Temperature at step 1 20 Temperature at step 2 Minimum operating temperature Temperature at step 3 20 (Standard temperature) Temperature at step 4 Maximum oparating temperature Temperature at step 5 20 8. Resistance to flexure of substrate NR30/40/50/60/80, NRV20/30, No damage NRH24/30, NRS20/40/50/60/80 Type NR10050 Type NS101, NS125Type No damage Test Method and Remarks NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type, NS101/125Type : The test samples shall be soldered to the test board by the reflow. As illustrated below, apply force in the direction of the arrow indicating until deflection of the test board reaches to 2 mm. Test board size : 100x40x1.0 Force Rod 20 10 Land dimension NRS20, NRV20 Land dimension Test board material : glass epoxy-resin R230 Solder cream thickness : 0.10 (NR30, NRS20, NRH24/30, NRV20/30) 3.2 2.0 0.15 (NR40/50/60/80, NRS40/50/60, NS101/125Type) Board R5 2.5 5.6 2.5 0.65 0.7 0.65 Test Sample 452mm 452mm NR50, NRS50 Land dimensionNR60, NRS60 Land dimension NR80, NRS80 Land dimension Land dimension NRH24Land dimensionNR30, NRH30, NRV30 Land dimensionNR40, NRS40Land dimension 2.0 0.7 0.75 0.7 4.0 3.7 2.7 0.8 1.4 0.8 1.2 1.6 1.2 1.5 2.1 1.5 7.5 5.7 1.6 3.1 1.6 1.8 3.8 1.8 3.2 2.5 8.6 2.5 Unit : mm This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. wound0407_reli-RP1 12 wound0407_reli_e-01 RELIABILITY DATA SMD inductor NR, NS series 9. Insulation resistance : between wires NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type NR10050 Type NS101, NS125Type 10. Insulation resistance : between wire and core NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type NR10050 Type NS101, NS125Type 11. Withstanding voltage : between wire and core NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type NR10050 Type NS101, NS125Type 12. Adhesion of terminal electrode NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type Shall not come off PC board NR10050 Type NS101, NS125Type Test Method and Remarks NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type, NS101/125 Type : The test samples shall be soldered to the test board by the reflow. Applied force : 10N to X and Y directions. Duration : 5s. 10N, 5s Solder cream thickness : 0.15mm. NR10050 Type : Applied force : 5N to X and Y directions. Duration : 5s. 13. Resistance to vibration NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type Inductance change : Within 10% NR10050 Type No significant abnormality in appearance. NS101, NS125Type Test Method and Remarks NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type, NR10050 Type, NS101/125 Type : The test samples shall be soldered to the test board by the reflow. Then it shall be submitted to below test conditions. Frequency Range Total Amplitude Sweeping Method Time 1055Hz 1.5mm (May not exceed acceleration 196m/s2) 10Hz to 55Hz to 10Hz for 1min. X Y For 2 hours on each X, Y, and Z axis. Z Recovery : At least 2hrs of recovery under the standard condition after the test, followed by the measurement within 48hrs. 14. Solderability NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type At least 90 of surface of terminal electrode is covered by new solder. NR10050 Type NS101, NS125Type Test Method and Remarks The test samples shall be dipped in flux, and then immersed in molten solder as shown in below table. Flux : Methanol solution containing rosin 25%. NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type, NR10050 Type, NS101/125 Type : Solder Temperature Time 2455 51.0 sec. Immersion depth : All sides of mounting terminal shall be immersed. 15. Resistance to soldering heat NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type Inductance change : Within 10% NR10050 Type No significant abnormality in appearance. NS101, NS125Type Test Method and Remarks NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type, NR10050 Type, NS101/125 Type : The test sample shall be exposed to reflow oven at 2305 for 40 seconds, with peak temperature at 2605 for 5 seconds, 2 times. Test board thickness : 1.0mmNR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type, NS101/125 Type 1.6mmNR10050 Type Test board material : glass epoxy-resin This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. wound0407_reli_e-01 12 wound0407_reli-RP2 RELIABILITY DATA SMD inductor NR, NS series 16. Thermal shock NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type Inductance change : Within 10% NR10050 Type No significant abnormality in appearance. NS101, NS125Type Test Method and Remarks NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type, NR10050 Type, NS101/125 Type : The test samples shall be soldered to the test board by the reflow. The test samples shall be placed at specified temperature for specified time by step 1 to step 4 as shown in below table in sequence. The temperature cycle shall be repeated 100 cycles. Conditions of 1 cycle Step 1 Temperature () 403 Duration (min) 303 2 Room temperature Within 3 3 852 303 4 Room temperature Within 3 17. Damp heat NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type NR10050 Type Inductance change : Within 10% No significant abnormality in appearance. NS101, NS125Type Inductance change : Within 10% No significant abnormality in appearance. Test Method and Remarks NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type, NS101/125Type : The test samples shall be soldered to the test board by the reflow. The test samples shall be placed in thermostatic oven set at specified temperature and humidity as shown in below table. Temperature Humidity Time 602 9095%RH 50024/0 hour 18. Loading under damp heat NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type Inductance change : Within 10% NR10050 Type No significant abnormality in appearance. NS101, NS125Type Test Method and Remarks NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type, NR10050 Type, NS101/125Type : The test samples shall be soldered to the test board by the reflow. The test samples shall be placed in thermostatic oven set at specified temperature and humidity and applied the rated current continuously as shown in below table. Temperature Humidity Applied current Time 602 9095RH Rated current 50024/0 hour 19. Low temperature life test NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type Inductance change : Within 10% NR10050 Type No significant abnormality in appearance. NS101, NS125Type Test Method and Remarks NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type, NR10050 Type, NS101/125Type : The test samples shall be soldered to the test board by the reflow. After that, the test samples shall be placed at test conditions as shown in below table. Temperature Time 402 50024/0 hour 20. High temperature life test NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type Inductance change : Within 10% No significant abnormality in appearance. NR10050 Type NS101, NS125Type Test Method and Remarks NR10050 Type : Temperature 1053 Time 50024/0 hour Recovery : At least 2hrs of recovery under the standard condition after the test, followed by the measurement within 48hrs. 21. Loading at high temperature life test NR30/40/50/60/80, NRV20/30, Inductance change : Within 10% NRH24/30, NRS20/40/50/60/80 Type No significant abnormality in appearance. NR10050 Type Inductance change : Within 10% NS101, NS125Type No significant abnormality in appearance. Test Method and Remarks NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80Type, NS101/125 Type : The test samples shall be soldered to the test board by the reflow soldering. Temperature Applied current Time 852 Rated current 50024/0 hour 22. Standard condition NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type NR10050 Type NS101, NS125Type Standard test condition : Unless otherwise specified, temperature is 2015 and 6520of relative humidity. When there is any question concerning measurement result: In order to provide correlation data, the test shall be condition of 202 of temperature, 655% relative humidity. Inductance is in accordance with our measured value. This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. wound0407_reli-RP3 12 wound0407_reli_e-01 PRECAUTIONS SMD inductor NR, NS series 1. Circuit Design Operating environment 1. The products described in this specification are intended for use in general electronic equipment,(office supply equipment, telecommunications systems, measuring equipment, and household equipment). They are not intended for use in mission-critical equipment or systems requiring special quality and high Precautions reliability (traffic systems, safety equipment, aerospace systems, nuclear control systems and medical equipment including life-support systems,) where product failure might result in loss of life, injury or damage. For such uses, contact TAIYO YUDEN Sales Department in advance. 2. PCB Design Land pattern design 1. Please refer to a recommended land pattern. Land pattern design Technical Surface Mounting considerMounting and soldering conditions should be checked beforehand. ations Applicable soldering process to this products is reflow soldering only. Precautions 3. Considerations for automatic placement Adjustment of mounting machine 1. Excessive impact load should not be imposed on the products when mounting onto the PC boards. Precautions 2. Mounting and soldering conditions should be checked beforehand. Technical Adjustment of mounting machine consider1. When installing products, care should be taken not to apply distortion stress as it may deform the products. ations 4. Soldering Reflow soldering 1. Please contact any of our offices for a reflow soldering, and refer to the recommended condition specified. 2. The product shall be used reflow soldering only. 3. Please do not add any stress to a product until it returns in normal temperature after reflow soldering. Lead free soldering 1. When using products with lead free soldering, we request to use them after confirming adhesion, temperature of resistance to soldering heat, soldering etc Precautions sufficiently. Recommended conditions for using a soldering iron (NR10050 Type) Put the soldering iron on the land-pattern. Soldering iron's temperature - Below 350 Duration - 3 seconds or less The soldering iron should not directly touch the inductor. Reflow soldering 1. If products are used beyond the range of the recommended conditions, heat stresses may deform the products, and consequently degrade the reliability of the products. Temperature NR30/40/50/60/80, NRV20/30, NRH24/30, NRS20/40/50/60/80 Type, NR10050 Type, NS101/125 Type Recommended reflow condition (Pb free solder) Technical considerations 5sec max 300 200 100 0 Peak 2505/0 150180 9030sec 3010sec 230 min eating Timesec 5. Cleaning Precautions Technical considerations Cleaning conditions 1. Washing by supersonic waves shall be avoided. Cleaning conditions 1. if washed by supersonic waves, the products might be broken. 6. Handling Handling 1. Keep the product away from all magnets and magnetic objects. Breakaway PC boards (splitting along perforations) 1. When splitting the PC board after mounting product, care should be taken not to give any stresses of deflection or twisting to the board. 2. Board separation should not be done manually, but by using the appropriate devices. Mechanical considerations Precautions 1. Please do not give the product any excessive mechanical shocks. 2. Please do not add any shock and power to a product in transportation. Pick-up pressure 1. Please do not push to add any pressure to a winding part. Please do not give any shock and push into a ferrite core exposure part. Packing 1. Please avoid accumulation of a packing box as much as possible. Breakaway PC boards (splitting along perforations) 1. The position of the product on PCBs shall be carefully considereed to minimize the stress caused from splitting of the PCBs. Mechanical considerations 1. There is a case to be damaged by a mechanical shock. Technical 2. There is a case to be broken by the handling in transportation. considerations Pick-up pressure 1. Damage and a characteristic can vary with an excessive shock or stress. Packing 1. If packing boxes are accumulated, that could cause a deformation on packing tapes or a damage on the products. 7. Storage conditions Storage 1. To maintain the solderability of terminal electrodes and to keep the packing material in good condition, temperature and humidity in the storage area should be controlled. Recommended conditions Ambient temperature : 540 Humidity : Below 70% RH Precautions Technical considerations The ambient temperature must be kept below 30. Even under ideal storage conditions, solderability of products electrodes may decrease as time passes. For this reason, product should be used within 6 months from the time of delivery. In case of storage over 6 months, solderability shall be checked before actual usage. Storage 1. Under a high temperature and humidity environment, problems such as reduced solderability caused by oxidation of terminal electrodes and deterioration of taping/packaging materials may take place. This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. wound0407_reli-RP4 12 wound0407_reli_e-01