IA NT Features Agency recognition: PL M CO oH S *R Applications Radial Leaded Devices Maximum 600 VAC interrupt fault rating Available in matched resistance "bins" Ability to withstand lightning surges RoHS compliant* Customer Premise Equipment (CPE): Modems Cable modems Fax machines POS equipment Security equipment Set top boxes MF-R/600 Series - Telecom PTC Resettable Fuses Electrical Characteristics Model MF-R015/600 MF-R015/600-A MF-R015/600-B MF-R015/600-F MF-R016/600 MF-R016/600-A MF-R016/600-1 Max. Operating Voltage 60 60 60 60 60 60 60 Max. Interrupt Ratings Volts Amps Max. Max. 600 600 600 600 600 600 600 3 3 3 3 3 3 3 Hold Current Trip Current Amps at 23 C Amps at 23 C 0.15 0.15 0.15 0.15 0.16 0.16 0.16 0.30 0.30 0.30 0.30 0.32 0.32 0.32 Initial Resistance One Hour Max. Time Tripped Post-Trip To Trip Power Resistance @1A Dissipation Ohms at 23 C Ohms at 23 C Ohms at 23 C Min. Max. Max. 6.0 7.0 9.0 7.0 4.0 4.0 4.0 12.0 10.0 12.0 12.0 10.0 7.0 8.0 22.0 20.0 22.0 22.0 18.0 16.0 17.0 Seconds at 23 C Watts at 23 C Typ. 5.0 5.0 5.0 5.0 7.0 7.0 7.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Environmental Characteristics Operating/Storage Temperature ..............................-40 C to +85 C Maximum Device Surface Temperature in Tripped State......................................................125 C Passive Aging ..........................................................+85 C, 1000 hours ..........................................................5 % typical resistance change +60 C, 1000 hours 5 % typical resistance change Humidity Aging ........................................................+85 C, 85 % R.H. 500 hours ..........................................5 % typical resistance change Thermal Shock ........................................................MIL-STD-202F, Method 107G, ........................................10 % typical resistance change +125 C to -55 C,10 times 15 % typical resistance change Solvent Resistance ..................................................MIL-STD-202, Method 215B............................................No change Lead Solerability ......................................................ANSI/J-STD-002 Flammability ............................................................IEC 695-2-2......................................................................No Flame for 60 secs. Vibration ..................................................................MIL-STD-883C, Method 2007.1, Condition A..................No change Test Procedures And Requirements For Model MF-R/600 Series Test Test Conditions Accept/Reject Criteria Visual/Mech. ......................................................Verify dimensions and materials..................Per MF physical description Resistance ..........................................................In still air @ 23 C ........................................Rmin R Rmax Time to Trip ........................................................5 times Ihold, Vmax, 23 C..........................T max. time to trip (seconds) Hold Current ......................................................30 min. at Ihold............................................No trip Trip Cycle Life ....................................................Vmax, Imax, 100 cycles ..............................No arcing or burning Trip Endurance....................................................Vmax, 48 hours ..........................................No arcing or burning UL File Number ..................................................E 174545S CSA File Number ................................................CA 110338 Thermal Derating Chart - Ihold (Amps) Ambient Operating Temperature Model MF-R015/600 MF-R016/600 -40 C 0.233 0.249 -20 C 0.206 0.219 0 C 0.178 0.190 Itrip is approximately two times Ihold. *RoHS Directive 2002/95/EC Jan 27 2003 including Annex Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications. 23 C 0.150 0.160 40 C 0.124 0.132 50 C 0.110 0.117 60 C 0.096 0.103 70 C 0.083 0.088 85 C 0.062 0.066 Additional Features Ability to withstand AC power cross conditions MF-R/600 Series - Telecom PTC Resettable Fuses Product Dimensions Model MF-R015/600 MF-R016/600 A Max. 13.5 (0.531) B Max. 12.6 (0.496) C Max. 6.0 (0.236) D Min. 4.7 (0.185) E Nom. 5.0 (0.197) 16.0 (0.629) 12.6 (0.496) 6.0 (0.236) 4.7 (0.185) 5.0 (0.197) Packaging options: BULK: 500 pcs. per bag. Longer lead lengths available upon request. A C PART IDENTIFICATION R015 DATE CODE (FIRST DIGIT = LAST DIGIT OF YEAR; SECOND DIGIT = MONTH; NEXT THREE DIGITS = LOT CODE) 24001K MF - R 015/600 - A 05 - 2 Multifuse(R) Product Designator Series R = Radial Leaded Component MFG. LOCATION (K = KOREA S = CHINA) Hold Current, Ihold 015-016 (0.15 - 0.16 Amps) Max. Interrupt Voltage, V Resistance Range Narrow resistance ranges are available on all models as defined in Electrical Characteristics. Maximum Time to Trip at 23 C 1000 Time to Trip (Seconds) MM (INCHES) How to Order MANUFACTURER'S TRADEMARK B Sn/Cu DIMENSIONS = Typical Part Marking E 0.65 (0.026) 1 TAPE & REEL: 600 pcs. per reel. Represents total content. Layout may vary. D Physical Characteristics Style Lead Dia. Material 0.65 1 Sn/Cu (0.026) Resistance Bins Narrow resistance ranges can be separated into packages where each device is within 0.5 ohms of each other. MF-R016/600 100 Packaging Options - 0 = Bulk Packaging - 2 = Tape and Reel* MF-R015/600 *Packaged per EIA486-B 10 1 0.10 0.00 0.50 1.00 1.50 2.00 2.50 3.00 Fault Current (Amps) Resistance Options Model MF-R015/600 MF-R015/600-A MF-R015/600-B MF-R015/600-F MF-R016/600 MF-R016/600-A MF-R016/600-1 Rmin. 6.0 7.0 9.0 7.0 4.0 4.0 4.0 Rmax. 12.0 10.0 12.0 12.0 10.0 7.0 8.0 R1Max. 22.0 20.0 22.0 22.0 18.0 16.0 17.0 Bin N/A 0.5 0.5 0.5 N/A 0.5 0.5 MF-R/600, REV. E, 11/04 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications. MF-R, MF-R/90, MF-R/600, MF-RX, MF-RX/72 & MF-RX/250 Series Tape and Reel Specifications Devices taped using EIA468-B/IEC286-2 standards. See table below and Figures 1 and 2 for details. Dimension Description IEC Mark EIA Mark Carrier tape width W W Hold down tape width: W0 W4 Hold down tape Top distance between tape edges Dimensions Dimensions Tolerance 18 (.709) 11 (.433) min. No protrusion W2 W6 3 (.118) W5 9 (.354) 4 (.157) 18.5 (.728) 16 (.63) 38.0 (1.496) 32.2 (1.268) 55.0 (2.165) 43.2 (1.7) 54.0 (2.126) 42.5 (1.673) 1.0 (.039) 11 (.433) Sprocket hole position W1 Sprocket hole diameter D0 D0 Abscissa to plane (straight lead) H H Abscissa to plane (kinked lead) H0 H0 Abscissa to top (straight lead) H1 H1 Abscissa to top (kinked lead) H1 H1 Overall width w/lead protrusion (straight lead) C1 Overall width w/lead protrusion (kinked lead) C1 Overall width w/o lead protrusion (straight lead) C2 C2 Overall width w/o lead protrusion (kinked lead) Lead protrusion I1 L1 Protrusion of cutout L L Protrusion beyond hold tape I2 I2 Not specified Sprocket hole pitch P0 P0 12.7 (0.5) Pitch tolerance 20 consecutive Device pitch: MF-R005-MF-R160, MF-R/90, MF-RX/72 12.7 (0.5) Device pitch: MF-R185-MF-R400, MF-RX110-MF-RX375, MF-R/600 25.4 (1.0) Tape thickness -0.5/+1.0 (-0.02/+.039) t t t1 Tape thickness with splice: MF-R010-MF-R160 Tape thickness with splice: MF-R250-MF-R1100 MF-RX110-MF-RX375, MF-R/90 t1 Splice sprocket hole alignment 0.9 (.035) 1.5 (.059) 2.3 (.091) 0 Body lateral deviation h h Body tape plane deviation p p Lead spacing F F Reel width w W2 Reel diameter d a Space between flanges less device W1 h 0 0 5.08 (0.2) 56 (2.205) 370 (14.57) 4.75 (.187) max. -0.5/+0.75 (-0.02/+0.03) 0.2 (.0078) 3.0 (.118) 0.5 (.02) max. max. max. max. max. max. max. max. 0.3 (.012) 1 max. max. max. 0.3 (.012) 1.0 (.039) 0.3 (.021) 0.2 (.008) max. max. 3.25 (.128) DIMENSIONS = Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications. MM (INCHES) MF-R, MF-R/90, MF-R/600, MF-RX, MF-RX/72 & MF-RX/250 Series Tape and Reel Specifications IEC Mark Dimension Description EIA Mark Dimensions Dimensions Tolerance Arbor hole diameter f c 26 (1.024) 12.0 (.472) Core diameter: MF-R, MF-RX, MF-R/90 h n 80 (3.15) max. Core diameter: MF-RX/250, MF-R/600 h n 91 (3.58) max. 56 (2.2) 67 (2.64) 64 (2.52) Box: MF-R, MF-RX, MF-R/90 Box: MF-RX/250 Box: MF-R/600 372 (14.6) 372 (14.6) 372 (14.6) Consecutive missing places: MF-R, MF-RX, MF-R/90 3 Consecutive missing places: MF-RX/250, MF-R/600 none 372 (14.6) 362 (14.25) 362 (14.25) Empty places per reel: MF-R, MF-RX, MF-R/90 Not specified Empty places per reel: MF-RX/250, MF-R/600 0.1 % max. max. max. max. Taped Component Dimensions - Figure 1 p h h p Reference plane P1 H1 A L I2 H1 F H H0 B W0 I1 P0 D0 DIMENSIONS = MM (INCHES) W1 W User direction of feed Cross section A - B Reel Dimensions - Figure 2 t Reel h d User direction of feed Upper side Tape Lower side f h w Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications.