3 Watt
Single
Output
30mW max of No Load Power Consumption
High efficiency up to 80%
Isolated Output 3kVAC / 1 min
Short Circuit Protection
Overvoltage Protection
Meet EN55022 and FCC Class B
Built-In Fusible Resistor
Features
Regulated
Converters
Selection Guide
Part Output Max. Ripple & Constant Efficiency
Number Voltage Current Noise Current Range (typ.)
(VDC) (lo, max) (mV) (1) (mA) (2) (%)
RAC03-3.3SC/277/W 3.3 900mA 200 1050-1350 71
RAC03-05SC/277/W 5 600mA 150 700-880 76
RAC03-12SC/277/W 12 250mA 150 310-390 78
RAC03-24SC/277/W 24 125mA 150 160-195 80
Input Voltage Range without Derating 85-305VAC or 110-430VDC
with 95% Derating 80-305VAC or 115-430VDC
Input Frequency 47-440Hz
Input Current (full Load) 115VAC/230VAC 70mA / 45mA typ.
Inrush Current 115VAC/230VAC 15A/30A max.
No Load Power Consumption 80-305VAC / 47-440Hz 30mW max.
Output Voltage (Vout nom.) 3.3V-24V
Minimum Load 0%
Line Voltage Regulation LL-HL at Full Load 1.5% max.
Load Voltage Regulation (3) 10-100% Load ±6% max.
Switching Frequency Full Load 45kHz typ.
Isolation Voltage Input-Output 3kVAC / 1 minute
Leakage Current 80-305VAC / 47-440Hz 10µA max.
Isolation Resistance Input-Output 1G Ωmin
Short Circuit Protection Continuous, Auto Restart
Over-Voltage Protection Zener clamp, set at 4.4V-5.0V for 3.3V and
112-140% of its nominal output voltage
Over Voltage Category OVC II
Operating Temperature natural convection, without derating -25°C to +75°C
natural air convection, with derating -25°C to +85°C
Storage Temperature -40°C to +85°C
Case Material UL94V-0 black plastic
Potting Material Silicone
Relative Humidity 95% RH max.
Package Weight 30g
Package Quantity 90 pcs
MTBF TA = 25°C > 1.000 x 10³ hours
(using MIL-HDBK217F)
TA = 75°C > 100 x 10³ hours
Physical Dimension (LxWxH) 38.25 x 24.35 x 17.40 mm
continued on next page
Derating Graph
(Ambient Temperature)
Specifications (@ TA 25°C, nominal input 100-277VAC after warm-up time with rated output current unless otherwise noted)
POWERLINE
AC/DC-Converter
with 3 year Warranty
EN-60950-1 Certified
IEC-60950-1 Certified
UL-60950-1 Certified
RAC03-C/277/W
100
60
40
20
0
80
Ambient Temperature Range (°C)
-25 200 40 60 80 100
Output Power (%)
120
Safe Operating Area
70
75 85
50
PA-10 REV: 0/2014 www.recom-power.com
E224736
RoHS
2011/65/EU
6/6
Refer to Application Notes
Descritption The ultra-compact wired RAC03-C/277/W modules are available with output voltages of
3.3, 5, 9, 12, 15, and 24V, and the input-to-output isolation is approximately 3kVAC/1min.
With a standby consumption of 30mW typical, the mini power supplies are particularly
suitable for energy-saving sleep mode and standby applications. Because of its compact
design (height <17 mm), it is a versatile solution for home automation and other similar
applications. Complete with an integrated input filter, the series has enhanced EMI
performance and complies with EN55022, class B. The mini power supplies are also
protected against short circuit with fully automatic restart after the error has been solved.
The converters are EN/UL60950-1 certified and come complete with a 3 year warranty.
www.recom-international.com PA-11
REV: 0/2014
RAC03-xxxC/277/W
Series
POWERLINE
AC/DC-Converter
Package Style and Pinning
Typical Characteristic
RAC03-
C/277/W
Notes:
Note1: Ripple and Noise is maximum peak-to-peak voltage value measured at output within 20Mhz bandwith, at rated line voltage and output load ranges.
Note2: Constant Current operation region is within 45% - 90% of Vo, nom. The Range includes all the tolerance of current precise, line regulation and load
load regulation. Typically, the current tolerance could be within ±7% at rated input voltage and output operation region for every single unit.used
Note3: „Total Regulation“ is the output voltage tolerance which includes initial voltage precise, thermal drift, line regulation and load regulation at rated input
voltage and load condition.
Specifications (@ TA 25°C, nominal input 100-277VAC after warm-up time with rated output current unless otherwise noted)
Io, max Icc1 Icc2
Io, min
0.4Vo, nom
0.9Vo, nom
0.94Vo, nom
1.06Vo, nom
Output V-I Characteristic
Vo
Io
24.35
12
4
3
Recommendend Footprint Details
Bottom View
0.75+0.25
-
17.4+0.25
-
5
38.25
17.4+0.25
-
10.0
85.0
AC IN
DC OUT
RECOM
RAC03-12SC/277/W
Input 100-277VAC
Output 12V/250mA
S
R
xxxx
Pb
LN
+-
105
80
Input Voltage (VAC) Ta=25°C
80 180
Load (%)
130 230 280
95
100
Input Voltage Derating Graph
Safe Operating Area
305
85
The product information and specifications are subject to change without prior notice. All products are designed for non-safety critical commercial and industrial applications.
The Buyer agrees to implement safeguards that anticipate the consequences of any failures that might cause harm, loss of life and/or damage property.
Wired Connections
Wired color Type Function
1 Brown UL-1015 AWG#22 VAC in (L)
2 Blue UL1015 AWG#22 VAC in (N)
3 Red UL-1430 AWG#22 +VDC out
4 Black UL-1430 AWG#22 -VDC out
Tolerance ±0.5mm unless otherwise specified
EMC Conducted and Radiated EN55022, Class B
Noise Immunity EN55024
Safety Standard
IEC General Safety CB-Report: 1311035-CB IEC-60950-1 2nd Edition
EN General Safety EN-60950-1 3rd Edtion
UL General Safety Report: E224736-A17 UL-60950-1
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
RECOM: