VLPS-75-24 Open Frame Power Supply
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 www.v-infinity.com 1-866-372-1258
DC output voltage 24V
Output rated current 3.2A
Output current range 0~3.5A
Rated output power 76.8W
Peak load(10 sec.) 84W
Ripple & noise 120mVp-p
Voltage adj. range 22~27V
Voltage tolerance ±2.0%
Line regulation ±1.0%
Load regulation ±1.0%
Setup, rise, hold time 100ms, 35ms, 50ms/230VAC 100ms, 35ms, 12ms/115VAC at full load
Input voltage range 90~264VAC 120~370VDC
Frequency range 47~63Hz
Efficiency 83%
AC current 1.9A/115V 1.1A/230V
Inrush current cold start 24A/115VAC 40A/230VAC
Leakage current <1mA/264VAC
Overload protection 115~150% rated output power
type: Hiccup mode, recovers automatically after fault condition is removed
Over voltage protection 27.6~32.4V type: Hiccup mode, recovers automatically after fault condition is
removed
Remote on/off RC+/RC- : 0~0.8V power on ; 4~10V power off
Working temperature -20~+60°C (Refer to output load derating curve)
Working humidity 20~90% RH non-condensing
Storage temp., humidity -20~+85°C, 10~95% RH
Temperature coefficient ±0.04%/°C (0~50°C)
Vibration 10~500Hz, 2G 10min./1 cycle, period for 60 min. each along X,Y,Z axes
Safety standards UL60950, TUV EN60950, approved
Withstand Voltage I/P-O/P: 3KVAC, I/P-F/G: 1.5KVAC, U/P-FG: 0.5KVAC
Isolation resistance I/P-O/P, I/P-F/G: 100M Ohms/500VDC min.
EMI conduction & radiation Compliance to EN55011, EN55022 (CISPR22) class B
Harmonic current Compliance to EN61000-3-2,-3
EMS immunity Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2
heavy industry level, criteria A
MTBF 355Khrs min. MIL-HDBK-217F (25°C)
Dimension 8.74x2.17x1.18 Inches (222x55x30mm)
Weight 0.66lbs (0.3Kg)
Notes: 1. All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient
2. Tolerance includes set up tolerance, line regulation, load regulation
3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
Features
·Universal AC input / Full range
·Short circuit, overload, over-voltage, protection
·Cooling by free air convection
·PWM control and regulated
·Small and compact size
·Built in remote on/off control
·LED indicator for power on
·100% full load burn-in test
·2 year warranty