T-13/4 (5 mm) Precision Optical
Performance AlInGaP LED
Lamps
Technical Data
Features
• Well Defined Spatial
Radiation Patterns
• Viewing Angles: 6°, 15°,
23°, 30°
• High Luminous Output
• Colors:
590 nm Amber
605 nm Orange
615 nm Reddish-Orange
626 nm Red
• High Operating
Temperature:
TJLED = +130°C
• Superior Resistance to
Moisture
• Package Options:
With or Without Lead Stand-
Offs
Benefits
• Viewing Angles Match
Traffic Management Sign
Requirements
• Colors Meet Automotive and
Pedestrian Signal
Specifications
• Superior Performance in
Outdoor Environments
• Suitable for Autoinsertion
onto PC Boards
Applications
• Traffic Management:
Traffic Signals
Pedestrian Signals
Work Zone Warning Lights
Variable Message Signs
• Commercial Outdoor
Advertising:
Signs
Marquees
• Automotive:
Exterior and Interior Lights
Description
These Precision Optical Perform-
ance AlInGaP LEDs provide
superior light output for excellent
readability in sunlight and are
extremely reliable. AlInGaP LED
technology provides extremely
stable light output over long
periods of time. Precision Optical
Performance lamps utilize the
aluminum indium gallium phos-
phide (AlInGaP) technology.
These LED lamps are untinted,
nondiffused, T-13/4 packages
incorporating second generation
optics producing well defined
spatial radiation patterns at
specific viewing cone angles.
These lamps are made with an
advanced optical grade epoxy,
offering superior high tempera-
ture and high moisture resistance
HP SunPower Series
HLMP-ELxx
HLMP-EJxx
HLMP-EHxx
HLMP-EGxx
performance in outdoor signal
and sign applications. The high
maximum LED junction tempera-
ture limit of +130°C enables high
temperature operation in bright
sunlight conditions. The package
epoxy contains both uv-a and
uv-b inhibitors to reduce the
effects of long term exposure to
direct sunlight.
These lamps are available in two
package options to give the
designer flexibility with device
mounting.
The HLMP-Exxx Series replace
the HLMP-Dxxx and HLMP-Uxxx
series products. A cross reference
is found on page 10 of this data
sheet.
22
Part Numbering Scheme
HLMP-E(1)(2)(3)-
(4)(5)(6)(7)(8)
where (1) = Color
“L” =592 nm Amber
“J” =605 nm Orange
“H” =615 nm Reddish-
orange
“G” =626 nm Red
where (2)(3) = Viewing
Angle and Lead Standoffs
“08” =6 degree without lead
standoffs
“10” =6 degree with lead
standoffs
“15” =15 degree without lead
standoffs
“17” =15 degree with lead
standoffs
“24” =23 degree without lead
standoffs
“26” =23 degree with lead
standoffs
“30” =30 degree without lead
standoffs
“32” =30 degree with lead
standoffs
where (4) = Minimum
Intensity Bin (refer to
table on page 9)
where (5) = Maximum
Intensity Bin (refer to
table on page 9)
where (6) = Color Bin
Selection
“K” =amber color bins 2
and 4 only (refer to
table on page 9)
“4” =amber color bin 4 only
(refer to table on
page 9)
where (7)(8) = Mechanical
or Packaging Option
“00” =bulk packaging,
minimum increment
500/bag
“DD”=ammo pack, minimum
increment 2000/box.
Available for products
shown in BOLD in
selection guide.
Refer to the device selection
guides for available
combinations.
Device Selection Guide
Typical
Viewing Color and Luminous
Angle Dominant Lamps Without Standoffs Lamps With Standoffs Intensity Iv (mcd) [1,2]
2θ1
/2Wavelength on Leads on Leads @ 20 mA
(Deg.)[4] (nm), Typ.[3] (Outline Drawing A) (Outline Drawing B) Min. Max.
HLMP-EL08-SV000 HLMP-EL10-SV000 1650 6300
HLMP-EL08-TW000 HLMP-EL10-TW000 2170 8300
HLMP-EL08-UW000 2750 8300
HLMP-EL08-UWK00* 2750 8300
HLMP-EL08-UX000 HLMP-EL10-UX000 2750 10700
HLMP-EL08-UXK00* 2750 10700
6°[5] Amber 590 HLMP-EL08-VW000 3600 8300
HLMP-EL08-VWK00* 3600 8300
HLMP-EL08-VX000 3600 10700
HLMP-EL08-VX400** 3600 10700
HLMP-EL08-VXK00* 3600 10700
HLMP-EL08-VY000 HLMP-EL10-VY000 3600 13800
HLMP-EL08-VYK00* 3600 13800
Notes:
1. The luminous intensity is measured on the mechanical axis of
the lamp package.
2. The optical axis is closely aligned with the package
mechanical axis.
3. The dominant wavelength, λd, is derived from the CIE
Chromaticity Diagram and represents the color of the lamp.
4. θ1/2 is the off-axis angle where the luminous intensity is one
half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at
the intensity peak.
Part numbers in bold are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.
“0” = no color bin limitation
3
Device Selection Guide (Continued)
Typical
Viewing Color and Luminous
Angle Dominant Lamps Without Standoffs Lamps With Standoffs Intensity Iv (mcd) [1,2]
2θ1/2Wavelength on Leads on Leads @ 20 mA
(Deg.)[4] (nm), Typ.[3] (Outline Drawing A) (Outline Drawing B) Min. Max.
HLMP-EJ08-TW000 HLMP-EJ10-TW000 2170 8300
HLMP-EJ08-UX000 HLMP-EJ10-UX000 2750 10700
Orange 605 HLMP-EJ08-VY000 HLMP-EJ10-VY000 3600 13800
HLMP-EJ08-WZ000 HLMP-EJ10-WZ000 4700 18400
HLMP-EH08-SV000 HLMP-EH10-SV000 1650 6300
HLMP-EH08-TW000 HLMP-EH10-TW000 2170 8300
Red-Orange 615 HLMP-EH08-UX000 HLMP-EH10-UX000 2750 10700
6°[5] HLMP-EH08-VY000 HLMP-EH10-VY000 3600 13800
HLMP-EG08-SV000 HLMP-EG10-SV000 1650 6300
HLMP-EG08-TW000 HLMP-EG10-TW000 2170 8300
HLMP-EG08-UW000 2750 8300
Red 626 HLMP-EG08-UX000 HLMP-EG10-UX000 2750 10700
HLMP-EG08-VW000 3600 8300
HLMP-EG08-VX000 3600 10700
HLMP-EG08-VY000 HLMP-EG10-VY000 3600 13800
HLMP-EL15-PS000 HLMP-EL17-PS000 765 2900
HLMP-EL15-QR000 1000 2200
HLMP-EL15-QRK00* 1000 2200
HLMP-EL15-QS000 1000 2900
HLMP-EL15-QS400** 1000 2900
Amber 590 HLMP-EL15-QSK00* 1000 2900
HLMP-EL15-QT000 HLMP-EL17-QT000 1000 3700
15°HLMP-EL15-QTK00* 1000 3700
HLMP-EL15-RU000 HLMP-EL17-RU000 1300 4800
HLMP-EL15-SV000 HLMP-EL17-SV000 1650 6300
HLMP-EJ15-PS000 HLMP-EJ17-PS000 765 2900
HLMP-EJ15-QT000 HLMP-EJ17-QT000 1000 3700
Orange 605 HLMP-EJ15-RU000 HLMP-EJ17-RU000 1300 4800
HLMP-EJ15-SV000 HLMP-EJ17-SV000 1650 6300
Notes:
1. The luminous intensity is measured on the mechanical axis of
the lamp package.
2. The optical axis is closely aligned with the package
mechanical axis.
3. The dominant wavelength, λd, is derived from the CIE
Chromaticity Diagram and represents the color of the lamp.
4. θ1/2 is the off-axis angle where the luminous intensity is one
half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at
the intensity peak.
Part numbers in bold are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.
44
Device Selection Guide (Continued)
Typical
Viewing Color and Luminous
Angle Dominant Lamps Without Standoffs Lamps With Standoffs Intensity Iv (mcd) [1,2]
2θ1
/2Wavelength on Leads on Leads @ 20 mA
(Deg.)[4] (nm), Typ.[3] (Outline Drawing A) (Outline Drawing B) Min. Max.
HLMP-EH15-PS000 HLMP-EH17-PS000 765 2900
HLMP-EH15-QT000 HLMP-EH17-QT000 1000 3700
Red-Orange 615 HLMP-EH15-RU000 HLMP-EH17-RU000 1300 4800
HLMP-EH15-SV000 HLMP-EH17-SV000 1650 6300
15°HLMP-EG15-PS000 HLMP-EG17-PS000 765 2900
HLMP-EG15-QT000 HLMP-EG17-QT000 1000 3700
Red 626 HLMP-EG15-RU000 HLMP-EG17-RU000 1300 4800
HLMP-EG15-SV000 HLMP-EG17-SV000 1650 6300
HLMP-EL24-LP000 HLMP-EL26-LP000 345 1330
HLMP-EL24-MQ000 HLMP-EL26-MQ000 450 1730
HLMP-EL24-NQ000 590 1730
HLMP-EL24-NQK00* 590 1730
HLMP-EL24-NR000 HLMP-EL26-NR000 590 2200
HLMP-EL24-NRK00* 590 2200
Amber 590 HLMP-EL24-PQ000 765 1730
HLMP-EL24-PQK00* 765 1730
HLMP-EL24-PR000 765 2200
HLMP-EL24-PR400** 765 2200
HLMP-EL24-PRK00* 765 2200
HLMP-EL24-PS000 HLMP-EL26-PS000 765 2900
23°HLMP-EL24-PSK00* 765 2900
HLMP-EJ24-MQ000 HLMP-EJ26-MQ000 450 1730
HLMP-EJ24-NR000 HLMP-EJ26-NR000 590 2200
Orange 605 HLMP-EJ24-PS000 HLMP-EJ26-PS000 765 2900
HLMP-EJ24-QT000 HLMP-EJ26-QT000 1000 3700
HLMP-EH24-LP000 HLMP-EH26-LP000 345 1330
HLMP-EH24-MQ000 HLMP-EH26-MQ000 450 1730
Red-Orange 615 HLMP-EH24-NR000 HLMP-EH26-NR000 590 2200
HLMP-EH24-PS000 HLMP-EH26-PS000 765 2900
HLMP-EG24-LP000 HLMP-EG26-LP000 345 1330
HLMP-EG24-MQ000 HLMP-EG26-MQ000 450 1730
Red 626 HLMP-EG24-NR000 HLMP-EG26-NR000 590 2200
HLMP-EG24-PS000 HLMP-EG26-PS000 765 2900
5
Device Selection Guide (Continued)
Typical
Viewing Color and Luminous
Angle Dominant Lamps Without Standoffs Lamps With Standoffs Intensity Iv (mcd) [1,2]
2θ1/2Wavelength on Leads on Leads @ 20 mA
(Deg.)[4] (nm), Typ.[3] (Outline Drawing A) (Outline Drawing B) Min. Max.
HLMP-EL30-LP000 HLMP-EL32-LP000 345 1330
HLMP-EL30-MQ000 HLMP-EL32-MQ000 450 1730
HLMP-EL30-NQ000 590 1730
HLMP-EL30-NQK00* 590 1730
HLMP-EL30-NR000 HLMP-EL32-NR000 590 2200
HLMP-EL30-NRK00* 590 2200
Amber 590 HLMP-EL30-PQ000 765 1730
HLMP-EL30-PQK00* 765 1730
HLMP-EL30-PR000 765 2200
HLMP-EL30-PR400** 765 2200
HLMP-EL30-PRK00* 765 2200
HLMP-EL30-PS000 HLMP-EL32-PS000 765 2900
HLMP-EL30-PSK00* 765 2900
HLMP-EJ30-MQ000 HLMP-EJ32-MQ000 450 1730
HLMP-EJ30-NR000 HLMP-EJ32-NR000 590 2200
30°Orange 605 HLMP-EJ30-PS000 HLMP-EJ32-PS000 765 2900
HLMP-EJ30-QT000 HLMP-EJ32-QT000 1000 3700
HLMP-EH30-KN000 HLMP-EH32-KN000 270 1000
HLMP-EH30-LP000 HLMP-EH32-LP000 345 1330
Red-Orange 615 HLMP-EH30-MQ000 HLMP-EH32-MQ000 450 1730
HLMP-EH30-NR000 HLMP-EH32-NR000 590 2200
HLMP-EG30-KN000 HLMP-EG32-KN000 270 1000
HLMP-EG30-LN000 345 1000
HLMP-EG30-LP000 HLMP-EG32-LP000 345 1330
Red 626 HLMP-EG30-MN000 450 1000
HLMP-EG30-MP000 450 1330
HLMP-EG30-MQ000 HLMP-EG32-MQ000 450 1730
HLMP-EG30-NR000 HLMP-EG32-NR000 590 2200
Notes:
1. The luminous intensity is measured on the mechanical axis of
the lamp package.
2. The optical axis is closely aligned with the package
mechanical axis.
3. The dominant wavelength, λd, is derived from the CIE
Chromaticity Diagram and represents the color of the lamp.
4. θ1/2 is the off-axis angle where the luminous intensity is one
half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at
the intensity peak.
Part numbers in bold are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.
66
NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS (INCHES).
2. LEADS ARE MILD STEEL, SOLDER DIPPED.
3. TAPERS SHOWN AT TOP OF LEADS (BOTTOM OF LAMP PACKAGE) INDICATE AN
EPOXY MENISCUS THAT MAY EXTEND ABOUT 1 mm (0.040 in.) DOWN THE LEADS.
4. RECOMMENDED PC BOARD HOLE DIAMETERS:
• LAMP PACKAGE A WITHOUT STAND-OFFS: FLUSH MOUNTING AT BASE OF
LAMP PACKAGE = 1.143/1.067 (0.044/0.042).
• LAMP PACKAGE B WITH STAND-OFFS: MOUNTING AT LEAD STAND-OFFS
= 0.965/0.889 (0.038/0.035).
5. FOR DOME HEIGHTS ABOVE LEAD STAND-OFF SEATING PLANE, d, LAMP PACKAGE
B, SEE TABLE.
B
Package Dimensions
A
1.14 ± 0.20
(0.045 ± 0.008)
5.80 ± 0.20
(0.228 ± 0.008)
5.00 ± 0.20
(0.197 ± 0.008)
31.60
(1.244) MIN.
0.70 (0.028)
MAX.
1.00
(0.039)MIN.
8.71 ± 0.20
(0.343 ± 0.008)
2.54 ± 0.38
(0.100 ± 0.015)
0.50 ± 0.10
(0.020 ± 0.004)SQ. TYP.
CATHODE
LEAD
2.35 (0.093)
MAX.
CATHODE
FLAT
1.14 ± 0.20
(0.045 ± 0.008)
5.80 ± 0.20
(0.228 ± 0.008)
5.00 ± 0.20
(0.197 ± 0.008)
31.60
(1.244) MIN.
0.70 (0.028)
MAX.
1.00
(0.039)MIN.
8.71 ± 0.20
(0.343 ± 0.008)
2.54 ± 0.38
(0.100 ± 0.015)
0.50 ± 0.10
(0.020 ± 0.004)SQ. TYP.
CATHODE
LEAD
CATHODE
FLAT
d
1.50 ± 0.15
(0.059 ± 0.006)
PART NO. d
HLMP-XX10
12.37 ± 0.25
(0.487 ± 0.010)
HLMP-XX17
12.42 ± 0.25
(0.489 ± 0.010)
HLMP-XX26
12.52 ± 0.25
(0.493 ± 0.010)
HLMP-XX32
11.96 ± 0.25
(0.471 ± 0.010)
7
Electrical/Optical Characteristics at TA = 25°C
Parameter Symbol Min. Typ. Max. Units Test Conditions
Forward Voltage IF = 20 mA
Amber (λd = 590 nm) 2.02
Orange (λd = 605 nm) VF1.98 2.4 V
Red-Orange (λd = 615 nm) 1.94
Red (λd = 626 nm) 1.90
Reverse Voltage VR520 VI
F
= 100 µA
Peak Wavelength: Peak of Wavelength of
Amber (λd = 590 nm) 592 Spectral Distribution
Orange (λd = 605 nm) λPEAK 609 nm at IF = 20 mA
Red-Orange (λd = 615 nm) 621
Red (λd = 626 nm) 635
Spectral Halfwidth ∆λ1/2 17 nm Wavelength Width at
Spectral Distribution
1/2 Power Point at
IF = 20 mA
Speed of Response τs20 ns Exponential Time
Constant, e-t/τ
Capacitance C 40 pF VF = 0, f = 1 MHz
Thermal Resistance RθJ-PIN 240 °C/W LED Junction-to-Cathode
Lead
Luminous Efficacy[1] Emitted Luminous
Amber (λd = 590 nm) 480 Power/Emitted Radiant
Orange (λd = 605 nm) ηv370 lm/W Power
Red-Orange (λd = 615 nm) 260
Red (λd = 626 nm) 150
Note:
1. The radiant intensity, Ie, in watts per steradian, may be found from the equation Ie = Iv/ηv, where Iv is the luminous intensity in
candelas and ηv is the luminous efficacy in lumens/watt.
Absolute Maximum Ratings at TA = 25°C
DC Forward Current[1,2,3] ............................................................ 50 mA
Peak Pulsed Forward Current[2,3] .............................................. 100 mA
Average Forward Current[3] ......................................................... 30 mA
Reverse Voltage (IR = 100 µA) ......................................................... 5 V
LED Junction Temperature.......................................................... 130°C
Operating Temperature .............................................. -40°C to +100°C
Storage Temperature .................................................. -40°C to +120°C
Dip/Drag Soldering Temperature ........................... 260°C for 6 seconds
Through-the-Wave Preheat Temperature ......................................145°C
Through-the-Wave Solder Temperature ................. 245°C for 3 seconds
[1.59 mm (0.060 in.) below seating plane]
Notes:
1. Derate linearly as shown in Figure 4.
2. For long term performance with minimal light output degradation, drive currents
between 10 mA and 30 mA are recommended. For more information on recommended
drive conditions, please refer to HP Application Brief I-024 (5966-3087E).
3. Please contact your Hewlett-Packard sales representative about operating currents
below 10 mA.
s
88
Figure 2. Forward Current vs.
Forward Voltage.
Figure 3. Relative Luminous Intensity
vs. Forward Current.
Figure 4. Maximum Forward Current
vs. Ambient Temperature. Derating
Based on TJMAX = 130°C.
Figure 1. Relative Intensity vs. Peak Wavelength.
Figure 5. Representative Spatial Radiation Pattern for 6 ° Viewing
Angle Lamps.
I
F
– FORWARD CURRENT – mA
0
0
T
A
– AMBIENT TEMPERATURE – °C
40 80
50
40
30
20
10
20 60 100
Rθ
JA
= 585° C/W
Rθ
JA
= 780° C/W
RELATIVE INTENSITY – %
100
0
θ – ANGULAR DISPLACEMENT – DEGREES
80
60
50
70
20
-20 -15
10
30
40
-10 0 5 10 15 20 25
90
-25 -5
RELATIVE LUMINOUS INTENSITY
(NORMALIZED AT 20 mA)
0
0
I
F
– DC FORWARD CURRENT – mA
40
3.0
2.0
1.5
1.0
0.5
20 60
2.5
Figure 6. Representative Spatial Radiation Pattern for 15° Viewing
Angle Lamps.
RELATIVE INTENSITY – %
100
0
θ – ANGULAR DISPLACEMENT – DEGREES
80
60
50
70
20
10
30
40
90
-20 -15 -10 0 5 10 15 20 25-25 -5
WAVELENGTH – nm
RELATIVE INTENSITY
550 600 650 700
1.0
0.5
0
AMBER RED-ORANGE
ORANGE RED
CURRENT – mA
1.0
0
V
F
– FORWARD VOLTAGE – V
2.5
100
40
30
1.5 2.0
60
3.0
10
20
50 RED
AMBER
70
80
90
9
Figure 7. Representative Spatial Radiation Pattern for 23° Viewing Angle Lamps.
Figure 8. Representative Spatial Radiation Pattern for 30° Viewing Angle Lamps.
RELATIVE INTENSITY – %
100
0
θ – ANGULAR DISPLACEMENT – DEGREES
80
60
50
70
20
10
30
40
90
-20 -15 -10 0 5 10 15 20 25-25 -5
RELATIVE INTENSITY – %
100
0
θ – ANGULAR DISPLACEMENT – DEGREES
80
60
50
70
20
10
30
40
90
-20 -15 -10 0 5 10 15 20 25-25 -5
Bin
Name Min. Max.
K 310 400
L 400 520
M 520 680
N 680 880
P 880 1150
Q 1150 1500
R 1500 1900
S 1900 2500
T 2500 3200
U 3200 4200
V 4200 5500
W 5500 7200
X 7200 9300
Y 9300 12000
Z 12000 16000
Intensity Bin Limits
(mcd at 20 mA)
Tolerance for each bin limit is ± 15%.
Bin
Name Min. Max.
1 584.5 587.0
2 587.0 589.5
4 589.5 592.0
6 592.0 594.5
HLMP-xLxx Color Bin
Limits (nm at 20 mA)
Tolerance for each bin limit is
± 0.5 nm.
Note:
1. Bin categories are established for
classification of products. Products
may not be available in all bin
categories.
1010
Part Number Cross Reference
Hewlett-Packard Precision Optical Performance
T-13/4 AlInGaP II lamps part numbers are changing.
The advantages of the new part numbering system
include:
- specification of maximum intensities
- for comparison/substitution purposes, easier
recognition of parts which are the same color
and viewing angle, but differ only in intensity
and/or color bin selection
In each case, except for HLMP-DL24 and DL26, the
new part number is an exact replacement for the old
part number.
Old Part Number New Part Number
HLMP-DG08 HLMP-EG08-UX000
HLMP-DG10 HLMP-EG10-UX000
HLMP-DG15 HLMP-EG15-RU000
HLMP-DG17 HLMP-EG17-RU000
HLMP-DG24 HLMP-EG24-PS000
HLMP-DG26 HLMP-EG26-PS000
HLMP-DG30 HLMP-EG30-MQ000
HLMP-DG32 HLMP-EG32-MQ000
HLMP-DH08 HLMP-EH08-UX000
HLMP-DH10 HLMP-EH10-UX000
HLMP-DH15 HLMP-EH15-RU000
HLMP-DH17 HLMP-EH17-RU000
HLMP-DH24 HLMP-EH24-PS000
HLMP-DH26 HLMP-EH26-PS000
HLMP-DH30 HLMP-EH30-MQ000
HLMP-DH32 HLMP-EH32-MQ000
HLMP-DJ08 HLMP-EJ08-WZ000
HLMP-DJ10 HLMP-EJ10-WZ000
HLMP-DJ15 HLMP-EJ15-RU000
HLMP-DJ17 HLMP-EJ17-RU000
HLMP-DJ24 HLMP-EJ24-QT000
HLMP-DJ26 HLMP-EJ26-QT000
HLMP-DJ30 HLMP-EJ30-PS000
HLMP-DJ32 HLMP-EJ32-PS000
HLMP-DL08 HLMP-EL08-VY000
HLMP-DL10 HLMP-EL10-VY000
HLMP-DL15 HLMP-EL15-SV000
HLMP-DL17 HLMP-EL17-SV000
HLMP-DL24 HLMP-EL25-QT000 or
HLMP-EL24-PS000*
HLMP-DL26 HLMP-EL27-QT000 or
HLMP-EL26-PS000*
HLMP-DL30 HLMP-EL30-PS000
HLMP-DL32 HLMP-EL32-PS000
*The new parts are not exact replacements for HLMP-DL2x.
HLMP-EL2x-QT000 are AlInGaP II lamps of equivalent intensity.
HLMP-EL2x-PS000 are AlInGaP lamps of slightly lower intensity.
11
Old Part Number New Part Number
HLMP-UG06 HLMP-EG08-SV000
HLMP-UG07 HLMP-EG10-SV000
HLMP-UG13 HLMP-EG15-PS000
HLMP-UG14 HLMP-EG17-PS000
HLMP-UG22 HLMP-EG24-LP000
HLMP-UG23 HLMP-EG26-LP000
HLMP-UG28 HLMP-EG30-KN000
HLMP-UG29 HLMP-EG32-KN000
HLMP-UH06 HLMP-EH08-SV000
HLMP-UH07 HLMP-EH10-SV000
HLMP-UH13 HLMP-EH15-PS000
HLMP-UH14 HLMP-EH17-PS000
HLMP-UH22 HLMP-EH24-LP000
HLMP-UH23 HLMP-EH26-LP000
HLMP-UH28 HLMP-EH30-KN000
HLMP-UH29 HLMP-EH32-KN000
HLMP-UJ06 HLMP-EJ08-TW000
HLMP-UJ07 HLMP-EJ10-TW000
HLMP-UJ13 HLMP-EJ15-PS000
HLMP-UJ14 HLMP-EJ17-PS000
HLMP-UJ22 HLMP-EJ24-MQ000
HLMP-UJ23 HLMP-EJ26-MQ000
HLMP-UJ28 HLMP-EJ30-MQ000
HLMP-UJ29 HLMP-EJ32-MQ000
HLMP-UL06 HLMP-EL08-SV000
HLMP-UL07 HLMP-EL10-SV000
HLMP-UL13 HLMP-EL15-PS000
HLMP-UL14 HLMP-EL17-PS000
HLMP-UL22 HLMP-EL24-MQ000
HLMP-UL23 HLMP-EL26-MQ000
HLMP-UL28 HLMP-EL30-LP000
HLMP-UL29 HLMP-EL32-LP000
For technical assistance or the location of
your nearest Hewlett-Packard sales office,
distributor or representative call:
Americas/Canada: 1-800-235-0312 or
408-654-8675
Far East/Australasia: Call your local HP
sales office.
Japan: (81 3) 3335-8152
Europe: Call your local HP sales office.
www.hp.com/go/led
Data subject to change.
Copyright © 1999 Hewlett-Packard Co.
Obsoletes 5968-2279E (10/98)
5968-3820E (1/99)