Product: 10GX24
10GX Category 6A Enhanced Cable, 4 Pair, U/UTP, LSZH
Product Description
10GX Category 6A Enhanced Premise Horizontal Cable (625MHz), 4 Pair, 23 AWG Solid Bare Copper Conductors, U/UTP, Haloarrest® LSZH Jacket
Technical Specifications
Product Overview
Suitable Applications: Premise Horizontal Cable, Ethernet up to 10GBASE-T, HDBaseT, PoE++, PoE+, PoE
Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/resources/patents.
Construction Details
Conductor
AWG Stranding Material Number of Pairs
23 Solid BC - Bare Copper 4
Insulation
Material Color Code
PO - Polyolefin White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown
Bonded-Pair: No
Outer Jacket Material
Separator Material Material Material Trade Name Nom. Diameter Ripcord
Double H Cross-Web (Patented RoundFlex®) LSZH - Low Smoke Zero Halogen (Flame Retardant) Haloarrest® 0.295 in Yes
Electrical Characteristics
Electricals
Max. Conductor DCR Max. DCR Unbalance Max. DCR Unbalanced Between Pairs [%] Max. Capacitance Unbalance Nom. Mutual Capacitance
7.4 Ohm/100m 3% 5% 90 pF/100m 17 pF/ft
Delay
Frequency [MHz] Max. Delay Max. Delay Skew Nom. Velocity of Propagation (VP) [%]
100 MHz 537.6 ns/100m 45 ns/100m 64%
High Freq
Frequency
[MHz]
Max. Insertion Loss
(Attenuation)
Min.
PSNEXT
[dB]
Min.
PSACR
[dB]
Min. PSACRF
(PSELFEXT) [dB]
Min. RL
(Return Loss)
[dB]
Max./Min. Input
Impedance (unFitted)
Max./Min. Fitted
Impedance
Min.
PSANEXT
Min.
PSAACRF
Min.
TCL [dB]
Min.
ELTCTL [dB]
1 MHz 2.1 dB/100m 73.3 dB 71.2 dB 68.8 dB 20.0 dB 100 ± 15 Ohm 100 ± 15 Ohm 67.0 dB 67.0 dB 40.0 dB 35.0 dB
4 MHz 3.8 dB/100m 64.3 dB 60.5 dB 56.8 dB 23.0 dB 100 ± 15 Ohm 100 ± 10 Ohm 67.0 dB 67.0 dB 40.0 dB 23.0 dB
8 MHz 5.3 dB/100m 59.8 dB 54.4 dB 50.7 dB 24.5 dB 100 ± 15 Ohm 100 ± 10 Ohm 67.0 dB 61.1 dB 40.0 dB 16.9 dB
10 MHz 5.9 dB/100m 58.3 dB 52.4 dB 48.8 dB 25.0 dB 100 ± 15 Ohm 100 ± 10 Ohm 67.0 dB 59.2 dB 40.0 dB 15.0 dB
16 MHz 7.5 dB/100m 55.2 dB 47.8 dB 44.7 dB 25.0 dB 100 ± 15 Ohm 100 ± 10 Ohm 67.0 dB 55.1 dB 40.0 dB 10.9 dB
20 MHz 8.4 dB/100m 53.8 dB 45.4 dB 42.8 dB 25.0 dB 100 ± 15 Ohm 100 ± 10 Ohm 67.0 dB 53.2 dB 38.0 dB 9.0 dB
25 MHz 9.4 dB/100m 52.3 dB 43.0 dB 40.8 dB 24.3 dB 100 ± 15 Ohm 100 ± 10 Ohm 67.0 dB 51.2 dB 36.0 dB 7.0 dB
31.25 MHz 10.5 dB/100m 50.9 dB 40.4 dB 38.9 dB 23.6 dB 100 ± 15 Ohm 100 ± 10 Ohm 67.0 dB 49.3 dB 35.1 dB
62.5 MHz 15.0 dB/100m 46.4 dB 31.4 dB 32.9 dB 21.5 dB 100 ± 15 Ohm 100 ± 10 Ohm 66.6 dB 43.3 dB 32.0 dB
100 MHz 19.1 dB/100m 43.3 dB 24.2 dB 28.8 dB 20.1 dB 100 ± 15 Ohm 100 ± 10 Ohm 63.5 dB 39.2 dB 30.0 dB
200 MHz 27.6 dB/100m 38.8 dB 11.2 dB 22.8 dB 18.0 dB 100 ± 22 Ohm 100 ± 10 Ohm 59.0 dB 33.2 dB 27.0 dB
250 MHz 31.1 dB/100m 37.3 dB 6.3 dB 20.8 dB 17.3 dB 100 ± 32 Ohm 100 ± 10 Ohm 57.5 dB 31.2 dB 26.0 dB
300 MHz 34.3 dB/100m 36.1 dB 1.9 dB 19.3 dB 16.8 dB 100 ± 32 Ohm 100 ± 10 Ohm 56.3 dB 29.7 dB 25.2 dB
350 MHz 37.2 dB/100m 35.1 dB 17.9 dB 16.3 dB 100 ± 32 Ohm 100 ± 10 Ohm 55.3 dB 28.3 dB 24.6 dB
400 MHz 40.1 dB/100m 34.3 dB 16.8 dB 15.9 dB 100 ± 32 Ohm 100 ± 10 Ohm 54.5 dB 27.2 dB 24.0 dB
450 MHz 42.7 dB/100m 33.5 dB 15.7 dB 15.5 dB 100 ± 32 Ohm 100 ± 10 Ohm 53.7 dB 26.1 dB 23.5 dB
500 MHz 45.3 dB/100m 32.8 dB 14.8 dB 15.2 dB 100 ± 32 Ohm 100 ± 10 Ohm 53.0 dB 25.2 dB 23.0 dB
550 MHz 47.7 dB/100m 32.2 dB 14.0 dB 14.9 dB 100 ± 32 Ohm 100 ± 10 Ohm 52.4 dB 24.4 dB
600 MHz 50.1 dB/100m 31.6 dB 13.2 dB 14.7 dB 100 ± 32 Ohm 100 ± 10 Ohm 51.8 dB 23.6 dB
625 MHz 51.2 dB/100m 31.4 dB 12.9 dB 14.5 dB 100 ± 32 Ohm 100 ± 10 Ohm 51.6 dB 23.3 dB
750 MHz 56.7 dB/100m 30.2 dB 11.3 dB 14.0 dB 50.4 dB 21.7 dB
860 MHz 61.2 dB/100m 29.3 dB 10.1 dB 13.6 dB 49.5 dB 20.5 dB
Voltage
UL Voltage Rating Non-UL Voltage Rating
300 V RMS 300 V
Mechanical Characteristics
Temperature
Operating Installation Storage
-20°C To +75°C 0°C To +50°C -20°C To +75°C
Bend Radius
Stationary Min. Installation Min.
1.25 in 3.0 in
Max. Pull Tension: 25 lbs
Bulk Cable Weight: 35 lbs/1000ft
Standards and Compliance
Environmental
Suitability: LSZH, Indoor, Non-Halogenated
Sustainability: Product Lens™, Environmental Product Declaration (EPD) Available
Flammability / Fire
Resistance: IEC 60332-1-2
ICEA Compliance: S-116-732-2013
IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4
NEMA Compliance: ANSI/NEMA WC-66
Data Category: Category 6A
TIA/EIA Compliance: ANSI/TIA-568.2-D Category 6A
Cenelec Compliance: Segregation class according EN50174-2=a
CPR Euroclass: Eca
European Directive
Compliance: EU Directive 2015/863/EU, EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16
APAC Compliance: China RoHS II (GB/T 26572-2011)
Other Standard
Compliance(s): Verified Channel/Category 6A
Part Number
Plenum Number: 10GX13
Non-Plenum Number: 10GX12
Variants
Item # Color Putup Type Length UPC/EAN
10GX24.10305 Black Reel 305 m 8719605000224
10GX24.06305 Blue Reel 305 m 8719605000156
10GX24 0061000 Blue Reel 1,000 ft 612825061854
10GX24.08305 Gray Reel 305 m 8719605000194
10GX24.08500 Gray Reel 500 m 8719605125149
10GX24.07305 Purple Reel 305 m 8719605000170
10GX24.07500 Purple Reel 500 m 8719605000187
10GX24 0071000 Purple Reel 1,000 ft 612825061830
10GX24.071000 Purple Reel 1,000 m 8719605000163
10GX24.09305 White Reel 305 m 8719605000200
10GX24.09500 White Reel 500 m 8719605000217
10GX24 0091000 White Reel 1,000 ft 612825061847
10GX24.04305 Yellow Reel 305 m 8719605000149
10GX24 0041000 Yellow Reel 1,000 ft 612825061861
10GX24.041525 Yellow Reel 1,525 m 8719605173232
Product Notes
Notes: Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Values above 625 MHz are for Engineering
Information Only. 0.295" Cable Dimension per TIA 6@1 Equivalent Diameter. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0.
History
Update and Revision: Revision Number: 0.466 Revision Date: 02-11-2021
© 2021 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.