CF
carbon film leaded resistors
Resistance
Range
E-24
(G±2%)
Resistance
Range
E-24
(J±5%)
Part
Designation
Absolute
Maximum
Working
Voltage
Absolute
Maximum
Overload
Voltage
Power
Rating
@ 70°C
applications and ratings
Minimum
Dielectric
Withstanding
Voltage
CFS1/4
CFPS1/4
CF1/4
CFP1/4
CFS1/2
CFPS1/2
0.25W
0.50W
0.50W
300V 500V
600V
700V
250V
300V
350V
800V400V
500V
700V
700V
2.2Ω - 1MΩ
2.2Ω - 47kΩ51kΩ - 100kΩ
110kΩ - 330kΩ
110kΩ - 330kΩ
2.2Ω - 100kΩ
100kΩ - 1MΩ
110kΩ - 1MΩ
360kΩ - 1MΩ
—
—
—
1.1MΩ - 2.2MΩ
1.0Ω - 91kΩ
2.2Ω - 91kΩ
10Ω - 330kΩ
10Ω - 100kΩ
10Ω - 1MΩ
2.2Ω - 1MΩ
2.2Ω - 1MΩ
2.2Ω - 5.1MΩ
1.0Ω - 5.1MΩ
Derating Curve
environmental applications
% Rated Power
100
80
60
40
20
-60 -40 04060 80 100 160
70
20
Ambient Temperature
(°C)
0
-55
120
155
-20 140
Surface Temperature Rise
Temperature Rise (°C)
60
50
40
30
20
0255075
% Rated Power
0100
10
CFPS1/4
CFS1/4
Surface
CFS1/2
CFB1/2
Load Life @ 70°C, 1000 Hr
∆ R/R (%)
+2
+1
0
10 100 1k 10k
Resistance
(Ω)
-2 100k
-1
1M
CFS1/4
Performance Characteristics
CFB1/2
2.4MΩ - 5.1MΩ
1.1MΩ - 2.2MΩ
2.2Ω - 100kΩ2.2Ω - 5.1MΩ
T.C.R.
(ppm/°C)
+350 to -450 0 to -700 0 to -1000 0 to -1300
360kΩ - 1MΩ
1.1MΩ - 5.1MΩ
2.4MΩ - 5.1MΩ
2.2Ω - 1MΩ
Parameter
Requirement ∆ R ±(% + 0.05Ω)
Limit Typical Test Method
Resistance
T.C.R.
Measuring points are at 10mm ±1mm from the end cap.
+25°C/+125°C
Within specified
tolerance
Within specified
T.C.R.
—
—
Overload (Short time) Rated voltage x 2.5 or max. overload voltage for 5 seconds, whichever is lower
±1% ±0.5%
Resistance to Solder Heat 260°C ±5°C, 10 seconds ± 1 second
±1% ±0.5%
Rapid Change of Temperature -55°C (30 minutes), +125°C (30 minutes), 5 cycles
±1% ±0.5%
Terminal Strength Twist 360°C, 5 times
No lead-coming off
and loose terminals —
Moisture Resistance 40°C ± 2°C, 90 - 95% RH, 1000 hours, 1.5 hr ON, 0.5 hr OFF cycle
±5% ±2.5%
Resistance to Solvent
(CFS & CFPS only) Ultrasonic washing with Isopropyl alcohol for 2 minutes.
Power: 0.3W/cm2, f: 28kHz, temp: 35°C±5°C
No abnormality
in appearance.
Marking shall be
easily legible.
––
Flame Retardant
(CFS & CFPS only)
Flame test: The test flame shall be applied and removed for each 15 seconds
respectively to repeat the cycle 5 times.
Overload flame retardant: Power (AC) corresponding to 2, 4, 8, 16 and 32
times the power rating shall be applied for each 1 minute until disconnection
occurs. However the applied voltage shall not exceed 4 times the maximum
operating voltage.
No evidence
of flaming or
self-flaming ––
Endurance at 70°C 70°C ± 2°C, 1000 hours, 1.5 hr ON, 0.5 hr OFF cycle
±3% ±1.5%
168 KOA Speer Electronics, Inc. • 199 Bolivar Drive • Bradford, PA 16701 • USA • 814-362-5536 • Fax: 814-362-8883 • www.koaspeer.com
Specifications given herein may be changed at any time without prior notice. Please confirm technical specifications before you order and/or use. 2/20/17
resistors
For resistors operated at an ambient temperature
of 70°C or above, a power rating shall be derated
in accordance with the above derating curve.
Operating temperature: -55°C ~ +155°C