40 E2E/E2E2 Cylindrical Proximity Sensor
Pre-wired Models
(Shielded)
Fig. 2: E2E-CR8@@
Fig. 1: E2E-CR6@@
Fig. 4: E2E-X1@@
Fig. 3: E2E-C1@@
Fig. 5: E2E-X2D@-N
E2E-X1R5E@/F@
Pre-wired Models
(Shielded)
Pre-wired Models
(Unshielded)
Fig. 6: E2E-X4MD@
E2E-X2ME@/F@
Fig. 7: E2E-X1R5Y@Fig. 8: E2E-X2MY@
Fig. 9: E2E-X3D@-N
E2E-X2E@/F@Fig. 10: E2E-X8MD@
E2E-X5ME@/F@
2.9-dia. vinyl-insulated round cable with
3 conductors (Conductor cross section: 0.14 mm2,
Insulator diameter: 0.9 mm),
Standard length: 2 m
Robotics cable Models: 2.9-dia. vinyl-insulated
round cable with 3 conductors (Conductor cross
section: 0.15 mm2, Insulator diameter: 1.05 mm),
Standard length: 2 m
The cable can be extended up to 100 m (separate
metal conduit).
2.9-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.14 mm2, Insulator diameter: 0.9 mm),
Standard length: 2 m
Robotics cable Models: 2.9-dia. vinyl-insulated round cable with
3 conductors (Conductor cross section: 0.15 mm2,
Insulator diameter: 1.05 mm), Standard length: 2 m
The cable can be extended up to 100 m (separate metal conduit).
2.9-dia. vinyl-insulated round cable
with 3 conductors
(Conductor cross section: 0.14 mm2,
Insulator diameter: 0.9 mm),
Standard length: 2 m
Robotics cable Models: 2.9-dia.
vinyl-insulated round cable with
3 conductors (Conductor cross
section: 0.15 mm2, Insulator
diameter: 1.05 mm),
Standard length: 2 m
The cable can be extended up to
100 m (separate metal conduit).
4-dia. vinyl-insulated round cable with
2 conductors (D Models)/3 conductors (E, F
Models)(Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm),
Standard length: 2 m
Robotics cable models: 4-dia.
vinyl-insulated round cable with
2 conductors (D Models)/3 conductors (E
Models)(Conductor cross section:
0.3 mm2, Insulator diameter: 1.27 mm),
Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
Note: D Models: Operation indicator (red),
setting indicator (green);
E, F Models: Operation indicator (red)
Note: D Models:
Operation indicator (red),
setting indicator (green);
E, F Models:
Operation indicator (red)
Note: D Models:
Operation indicator (red),
setting indicator (green);
E, F Models:
Operation indicator (red)
Note: D Models: Operation indicator (red),
setting indicator (green);
E, F Models: Operation indicator (red)
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
0.3 mm2, Insulator diameter: 1.3 mm),
Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
0.3 mm2, Insulator diameter: 1.3 mm),
Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
4-dia. vinyl-insulated round cable with
2 conductors (D Models)/3 conductors
(D@S,E, F Models) (Conductor cross section:
0.3 mm2,Insulator diameter: 1.3 mm),
Standard length: 2 m
Robotics cable Models: 4-dia.
vinyl-insulated round cable with 2 conductors
(D Models)/3 conductors (E Models)
(Conductor cross section: 0.3 mm2, Insulator
diameter: 1.27 mm),
Standard length: 2 m
The cable can be extended (separate metal conduit)
up to 200 m (control output) or up to 100 m
(dia
nostic output).
4-dia. vinyl-insulated round cable with
2 conductors (D Models)/3 conductors
(E, F Models)(Conductor cross section:
0.3 mm2, Insulator diameter: 1.3 mm),
Standard length: 2 m
Robotics cable Models: 4-dia.
vinyl-insulated round cable with
2 conductors (D Models)/3 conductors
(E Models)(Conductor cross section:
0.3 mm2, Insulator diameter: 1.27 mm),
Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
4-dia. vinyl-insulated round cable with
2 conductors (D Models)/3 conductors
(D@S, E, F Models) (Conductor cross section:
0.3 mm2, Insulator diameter: 1.3 mm),
Standard length: 2 m
Robotics cable models: 4-dia.
vinyl-insulated round cable with 2 conductors
(D Models)/3 conductors (E Models)
(Conductor cross section: 0.3 mm2, Insulator
diameter: 1.27 mm),
Standard length: 2 m
The cable can be extended (separate metal
conduit) up to 200 m (control output) or up to
100 m (diagnostic output).
Pre-wired e-CON connector Model
1
15
2
3
4
5.9
15.6
Connector:
Product code 37104-3163-000FL
(Sumitomo 3M)
Pre-wired e-CON connector Model
1
15
2
3
4
5.9
15.6
Connector:
Product code 37104-3163-000FL
(Sumitomo 3M)
4 dia. 25
17.5
Operation
indicator
(red)
5.4 dia. 25
17.5
Operation
indicator
(red)
15 dia.
3
13
26
8
7
30
M8 × 1 Indicator
(See note.)
Two clamping
nuts
Toothed
washer
15 dia.
6.1 dia.
36
13
26
8
7
30
M8 × 1 Indicator
(See note.)
Two
clamping nuts
Toothed
washer
15 dia.
3
13
36
8
7
40
M8 × 1 Operation Indicator (red)
Two
clamping nuts
Toothed
washer
15 dia.
6.1 dia.
36
13
36
8
7
40
M8 × 1 Operation
indicator (red)
Two
clamping nuts
Toothed
washer
21 dia.
4
17
33
10
9
38
M12 × 1 Indicator
(See note.)
Two
clamping nuts
Toothed washer
4
815
25
17.5
9.7 dia.
M5 × 0.5
Operation
indicator (red)
Two clamping nuts
Toothed
washer
21 dia.
9 dia.
47
17
33
10
9
38
M12 × 1 Indicator
(See note.)
Two
clamping nuts
Toothed
washer
3±0.1 dia. 27
17
Operation
indicator
(red)
2.4-dia. (7/0.127-dia.) vinyl-insulated round cable
with 3 conductors,
Standard length: 2 m