.648
.040
.020
MANAGEMENT BAR STRAIN RELIEF
.260
REFERENCE THE FOLLOWING DOCUMENTS:
DTERMINATION INSTRUCTIONS LTI-004
TOOLING INFORMATION LCT-002
LCT-003 (PROPRIETARY) MAY VARY
NONE
FSCM NO.
A
B
.05
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PLUG,RJ45 8X8 SHIELDED W/STRAIN RELIEF
.005
01845
SCALE:
SIZE
CAD FILE:
DWG. NO.
A
SHEET OF
REV.
DATE
APPROVALS
DRAWN BY
CHECKED BY
APPROVED BY
12
3
4
5
6
CABLE LENGTH TOLERANCE
C
D
45 BEECHWOOD DRIVE
WITHOUT THE WRITTEN PERMISSION OF L-COM, INC. IS PROHIBITED.
OUTLINE DRAWING
A
B
C
D
12
3
4
5
6
7
8
.XXX
NORTH ANDOVER, MA
PROPERTY OF L-COM, INC. ANY REPRODUCTION IN PART OR WHOLE
.SLDDRW 11
D. PARHAM 2/3/2004
REVISIONS
DESCRIPTION APPROVED
REV DATE
T. CLARK
C. McCORMICK
2/3/2004
2/3/2004
2/3/04C
D
ECN1618: ADDED COMPONENT SPECIFICATION TABLE. UPDATED FORMAT
ECN#2230: ADDED REFERENCE DOCUMENTATION LINKS 10/12/05
TDS8PC5-OD1 D
TDS8PC5-OD1
<300" ±5% >300" ±2%
DRAWING TITLE
D. PARHAM
7
8
D. PARHAM
PRODUCT DESCRIPTION
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES
TOLERANCES ARE:
.X .1
.XX CONFIGURATION DETAILS OF
UNDIMENSIONED FEATURES 43321
.460
Component Specifications
Material
Housing Polycarbonate, UL9V-0 rated
Management Bar Polycarbonate, UL9V-0 rated
Shielding Brass
Contacts Phosphor Bronze
Finish
Shielding 80 µinches Nickel
Contacts 50 µinches Gold (in contact area) over Nickel
Electrical
Current Rating 1.5A
Contact Resistance 20 m @ 100 mA max, 50 mV max
Insulation Resistance 500 M min @ 500 VDC
Dielectric Withstanding
Voltage 1000 Vac, 60Hz for 1 minute
Mechanical
Design Meets requirements of FCC 68.5 Subpart F
Mating Durability 1000 cycles
Cable OD Range .228” to .256”
Conductor OD Range 24 and 26 AWG (Insulation O.D.: .039”)
Conductor Type Solid or Stranded
Environmental
Operating Temperature -40°C to 80°C
CS-226