11EPCOS do Brasil Ltda.
Specifications and characteristics in brief
Rated voltage UR160 ... 350 Vdc
Surge voltage US1.1 . UR
Rated capacitance CR3.3 ... 220 µF
Capacitance tolerance ± 20 (M) %
Useful life
125°C, U ; Iac
R max
2 000 h
Failure rate ≤ 100 fit
( 1 fit = 10-9/h)
Voltage endurance test 2 000, 125°C
C/C
Tan 30% of initial measured value
initial specified value
IL
times initial specified value
h
Evaluation criteria:
Climatic category
in accordance
with IEC 60068
Standards IEC 60384
25/125/56 - U = 350V
R
40/125/56 - U 350V
R
-4
Vibration resistance in accordance with IEC 68068 - 2, test Fc:
Displacement amplitude 0.75 mm, frequency range
10 ... 2000 Hz, acceleration max. 10 g, duration 3 x 2 h
Specifications and characteristics in brief
Rated voltage
UR160 ... 350 Vdc
Surge voltage
US1.1 . UR
Rated capacitance CR3.3 ... 100 µF
Capacitance tolerance ± 20 (M) %
Useful life
140°C, U ; Iac
R max
1 000 h
Failure rate ≤ 100 fit
( 1 fit = 10-9/h)
Voltage endurance test 1 000, 140°C h
Evaluation criteria:
Climatic category
in accordance
with IEC 60068
Standards IEC 60384 -4
Vibration resistance in accordance with IEC 68068 - 2, test Fc:
Displacement amplitude 0.75 mm, frequency range
10 ... 2000 Hz, acceleration max. 10 g, duration 3 x 2 h
B43866 High Temperature 125°C
B43867 High Temperature 140°C
30 % of initial measured value
C/C 2 times initial specified value
Tan initial specified value
IL
40/140/56 - U 250V
R
25/140/56 - U 350V
R