TQDILP
Corning Frequency Control • Worldwide Data Book 2001 v1.0.2000-10-31
Corning Frequency Control Inc. • 100 Watts Street • Mt. Holly Springs, PA 17065 • Tel 1-717-486-3411 • Fax 1-717-486-5920 • www.corningfrequency.com
Tele Quarz GmbH & Co. KG • Landstrasse • D-74924 Neckarbischofsheim, Germany • Tel +49-7268-801-0 • Fax +49-07268-801-281 • www.telequarz.de
1 / 2
Typical Applications Features
Base Stations AT-Cut Crystal
Test Equipment Dual-inline oszillator
Synthesizers Hermetically Sealed Package
Surface Mount Option
Frequency range 30 MHz – 90 MHz
Standard frequencies 30.72; 32.768; 50; 68.768MHz
Frequency stabilities
Parameter Code II Frequency stability Operating temp range
20 ± 100 ppm
21 ± 50 ppm -55 ... +125°C
22 ± 50 ppm
24 ± 25 ppm -55 ... +105°C
34 ± 15 ppm -40 ... +90°C
32 ± 10 ppm -30 ... +80°C
10 ± 50 ppm
12 ± 20 ppm
14 ± 10 ppm
16 ± 7.5 ppm
vs. operating temperature range
18 ± 5.0 ppm
-20 ... +70°C
Parameter Code I Frequency stability Condition
Initial tolerance 01 ± 100 ppm @ 25°C
02 ± 50 ppm
03 ± 20 ppm
05 ± 10 ppm
07 ± 5 ppm
RF output
Parameter Value Condition
Signal LS-TTL
Fan out 10
Rise and Fall time < 10 ns 30 MHz to 40 MHz
< 6 ns ≥ 40 MHz
Duty cycle 40/60 % @ 1.5 V
Supply voltage
Parameter Value Condition
Supply voltage (Vs) 5.0 V ± 5 %
Current consumption < 40 mA
Additional parameters
Parameter Value Condition
Phase Noise <-80 dBc/Hz 10 Hz Note 1
<-110 dBc/Hz 100 Hz
<-135 dBc/Hz 1kHz
<-145 dBc/Hz 10 kHz
<-150 dBc/Hz 100 kHz
Weight < 6 g