LD (ALD)
ORDERING INFORMATION
TYPES
Packing quantity: Carton 100 pieces, Case 500 pieces
Note: The “W” at the end of the part number only appears on the inner and outer packaging. It does not appear on the relay itself.
Please consult with our sales office on a tube pa king type.
RATING
1. Coil data
1a 3A slim power relays
LD RELAYS (ALD)
Contact arrangement Nominal coil voltage Part No.
1 Form A
4.5V DC ALD14HW
5V DC ALD105W
6V DC ALD106W
9V DC ALD109W
12V DC ALD112W
18V DC ALD118W
24V DC ALD124W
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
4.5V DC
75%V or less of
nominal voltage
(Initial)
5%V or more of
nominal voltage
(Initial)
44.6mA 101
200mW 130%V of
nominal voltage
5V DC 40.0mA 125
6V DC 33.3mA 180
9V DC 22.2mA 405
12V DC 16.7mA 720
18V DC 11.1mA 1,620
24V DC 8.3mA 2,880
VDE
RoHS compliant
FEATURES
1. Slim type: Width 7 mm .276 inch.
20.3(L)×7.0(W)×15.0(H) mm
.799(L)×.276(W)×.591(H) inch
2. Perfect for small load switching of
home appliances
105 switching operations possible with a
3A 250V AC resistive load.
3. Low operating power
Compact size, nominal operating power
as low as 200mW.
4. High shock resistance
The relay withstands a functional shock
resistance of 300m/s2 [approx. 30 G
more]
5. High insulation resistance
Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch
Surge withstand voltage between
contact and coil: 10,000 V
6. UL, CSA, VDE, TÜV approved.
TYPICAL APPLICATIONS
Air conditioner
Refrigerator
Hot water units
Microwave ovens
Fan heaters
LD relay
ALD 1 W
Nominal coil voltage (DC)
4H: 4.5V, 05: 5V, 06: 6V, 09: 9V, 12: 12V, 18: 18V, 24: 24V
Packing style
W: Carton packing
Contact arrangement
1: 1 Form A
Note: Certified by UL, CSA, TÜV and VDE
To Be Discontinued:
Made in Japan type
(Made in Thailand type already
discontinued)
Last time buy:September 30, 2014
2013.09 industrial.panasonic.com/ac/e/ ©Panasonic Corporation 2013
–1– ASCTB192E 201309-T
Automation Controls Catalog
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
Characteristics Item Specification
Contact
Arrangement 1 Form A
Contact resistance (Initial) Max. 100 m (By voltage drop 6 V DC 1A)
Contact material AgNi type
Rating
Nominal switching capacity (resistive load) 3A 277V AC, 3A 30V DC
Max. switching power (resistive load) 831VA (AC), 90W (DC)
Max. switching voltage 277V AC, 30V DC
Max. switching current 3A
Min. switching capacity*1100mA, 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 750 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Temperature rise (coil) Max. 45°C 113°F (By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 3A, at 70°C 158°F)
Surge breakdown voltage*2
(Between contact and coil) (Initial) 10,000 V
Operate time (at nominal voltage) (at 20°C 68°F) Max. 10 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20°C 68°F) Max. 10 ms (excluding contact bounce time) (With diode)
Mechanical
characteristics
Shock resistance Functional 300 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Destructive 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life Mechanical (at 180 times/min.) Min. 5×106
Electrical (at 20 times/min.) Min. 2×105 (3A 125V AC, 3A 30V DC at rated load), Min. 105 (3A 250V AC at rated load)
Conditions Conditions for operation, transport and storage*3Ambient temperature: –40°C to +70°C –40°F to +158°F,
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 4 g .14 oz
1. Max. switching power 2. Life curve 3. Coil temperature rise
Sample: ALD112W, 6 pcs.
Point measured: inside the coil
Contact current: 0 A, 3 A
0.2
0.3
0.4
0.5
1.0
2.0
3.0
20 30 50 100 200 3000
Contact voltage, V
Contact current, A
AC resistive load
DC resistive load
0
10
30
50
100
123
125V AC
resistive load
Contact current, A
Life, ×104
Coil applied voltage, %V
Temperature rise, °C
70°C
1000 125 175150
70
60
50
40
30
20
10
0
3A
0A
20°C
4-(1). Operate time
Sample: ALD112W, 6 pcs.
4-(2). Release time (without diode)
Sample: ALD112W, 6 pcs.
4-(3). Release time (with diode)
Sample: ALD112W, 6 pcs.
Coil applied voltage, %V
Operate time, ms
80 100 140120
10
8
6
4
2
0
Max.
Min.
Coil applied voltage, %V
Release time, ms
80 100 140120
10
8
6
4
2
0
Max.
Min.
Coil applied voltage, %V
Release time, ms
80 100 140120
10
8
6
4
2
0
Max.
Min.
To Be Discontinued:Made in Japan type (Made in Thailand type already discontinued)
Last time buy:September 30, 2014
©Panasonic Corporation 2013
Panasonic Corporation Automation Controls Buisiness Division
industrial.panasonic.com/ac/e/ –2– ASCTB192E 201309-T
LD (ALD)
DIMENSIONS (mm inch)
SAFETY STANDARDS
UL/C-UL (Recognized) CSA (Certified VDE (Certified TÜV (Certified
File No. Contact rating File No. Contact rating File No. Contact rating File No. Rating
E43028 3A 277V AC
3A 30V DC
LR26550
etc.
3A 277V AC
3A 30V DC
40014384 3A 250V AC (cos
φ
= 1.0)
3A 30V DC (0ms)
B 11 03
13461 289
3A 250V AC (cos
φ
= 1.0)
3A 30V DC (0ms)
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
0.4 dia.
0.4
0.8
1.15
4.7
0.2
0.2
3.4
Max. 20.5
Max. 15.3
Max. 7.2
11.5
1.05 7.0
016 dia.
.016
.031
.045
.185
.008
.008
.134
.807
.602
.284
.453
.041 .276
PC board pattern (Bottom view)
Tolerance: ±0.1 ±.004
Schematic (Bottom view)
4-1.1 dia.
(1.15)
(1.05) 11.5
4.7
7.0
4-.043 dia.
(.045)
(.041) .453
.185
.276
COIL
COM NO
CAD Data
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
General tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
To Be Discontinued:Made in Japan type (Made in Thailand type already discontinued)
Last time buy:September 30, 2014
©Panasonic Corporation 2013
Panasonic Corporation Automation Controls Buisiness Division
industrial.panasonic.com/ac/e/ –3– ASCTB192E 201309-T
LD (ALD)