SPECIFICATION
25WAC-DC High Reliability IndustrialAdaptor GST25E series
File Name:GST25E-SPEC 2015-06-24
GST25E05-P1J
GST25E07-P1J
GST25E09-P1J
GST25E12-P1J
GST25E15-P1J
GST25E18-P1J
GST25E24-P1J
GST25E28-P1J
GST25E48-P1J
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 8)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V
GST25E05
7.5V
GST25E07
9V
GST25E09
12V
GST25E12
15V
GST25E15
18V
GST25E18
24V
GST25E24
28V
GST25E28
48V
GST25E48
80mVp-p 80mVp-p 80mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
47 ~ 63Hz
0.25mA / 240VAC
TUV EN60950-1 approved
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
500Khrs min. MIL-HDBK-217F(25 )℃
20% ~ 90% RH non-condensing
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
79*54*33mm (L*W*H)
CONNECTOR
PLUG
CABLE
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
OVERLOAD
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Clamp by zener diode
4.0A 2.93A 2.55A 2.08A 1.66A 1.38A 1.04A 0.89A 0.52A
0 ~ 4.0A 0 ~ 2.93A 0 ~ 2.55A
0 ~ 2.08A
0 ~ 1.66A 0 ~ 1.38A 0 ~ 1.04A
0 ~ 0.89A
0 ~ 0.52A
20W 22W 23W 25W 25W 25W 25W 25W 25W
EMC IMMUNITY
EMC EMISSION
See page 3,4 ; Other type available by customer requested
See page 3,4 ; Other type available by customer requested
80mVp-p
85 ~ 264VAC
81.5% 84.5% 85% 86.5% 87% 87% 88% 88% 89%
110 ~ 140% rated output voltage
1000ms, 30ms, 50ms/230VAC 1500ms, 30ms, 15ms/115VAC at full load
0.6A / 115VAC 0.35A / 230VAC
35A / 115VAC 65A / 230VAC
202.5g; 60pcs/13.2Kg/1.22CUFT
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.Derating may be needed under low input voltage. Please check the derating curve for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
Compliance to EN55022 class B, EN61000-3-2,3
-30 ~ +70 (Refer to "Derating Curve")℃
-40 ~ +85 , 10 ~ 95% RH℃
±℃℃0.03% / (0 ~ 50 )
VOLTAGE RANGE Note.7