Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1592A Multi-Conductor - Category 5e Nonbonded-Pair Patch Cable For more Information please call 1-800-Belden1 General Description: CAT5e (200MHz), 4-Pair, U/UTP-Unshielded, CM Rated, Premise Patch Cable, 24 AWG Stranded (7x32) Bare Copper Conductors, Polyolefin Insulation, PVC Jacket, RJ-45 Compatible Usage (Overall) Suitable Applications: Premise Patch Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422 Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 4 24 7x32 BC - Bare Copper Total Number of Conductors: 8 Insulation Insulation Material: Insulation Material PO - Polyolefin Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Outer Jacket Diameter: Nom. Dia. (mm) 5.410 Pair Pair Color Code Chart: Number Color 1 White/Blue Stripe & Blue 2 White/Orange Stripe & Orange 3 White/Green Stripe & Green 4 White/Brown Stripe & Brown Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +75C Bulk Cable Weight: 31.252 Kg/Km Max. Recommended Pulling Tension: 111.205 N Min. Bend Radius/Minor Axis: 25.400 mm Min. Bend/Installation: 53.340 mm Page 1 of 4 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1592A Multi-Conductor - Category 5e Nonbonded-Pair Patch Cable Min. Bend/Installation: 53.340 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CM CEC/C(UL) Specification: CM EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Telecommunications Standards: Category 5e - TIA 568.C.2 Other Specification: ICEA 661 Category 5 Patch Flame Test UL Flame Test: UL1685 Vertical Tray Flame Test C(UL) Flame Test: FT1 CSA Flame Test: FT1 Suitability Suitability - Indoor: Yes Suitability - Outdoor: No Suitability - Aerial: No Suitability - Burial: No Sunlight Resistance: No Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Mutual Capacitance: Capacitance (pF/m) 49.215 Maximum Capacitance Unbalance (pF/100 m): 330 Nominal Velocity of Propagation: VP (%) 69 Maximum Delay: Delay (ns/100 m) 510 @ 100MHz Typical Delay Skew: Delay Skew (ns/m) 0.121 Max. Delay Skew: Delay Skew (ns/100 m) 45 Page 2 of 4 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1592A Multi-Conductor - Category 5e Nonbonded-Pair Patch Cable Maximum Conductor DC Resistance: DCR @ 20C (Ohm/100 m) 9.38 Max. Operating Voltage - UL: Voltage 300 V RMS Maximum DCR Unbalanced: DCR Unbalance @ 20C (%) 3 Electrical Characteristics-Premise (Overall) Premise Cable Electrical Table 1: Freq. (MHz) Max. Attenuation (dB/100 m) Min. NEXT (dB) Min. PSNEXT (dB) Min. ACR (dB) Min. PSACR (dB) Min RL (dB) Min. SRL (dB) 1 2.5 65.3 62.3 62.8 59.8 20.0 23.0 4 4.9 56.3 53.3 51.4 48.4 23.0 23.0 8 6.9 51.8 48.8 44.9 41.9 24.5 24.5 10 7.8 50.3 47.3 42.5 39.5 25.0 25.0 16 9.9 47.3 44.3 37.4 34.4 25.0 25.0 20 11.1 45.8 42.8 34.7 31.7 25.0 25.0 25 12.5 44.3 41.3 21.8 28.8 24.3 24.3 31.25 14.1 42.9 39.9 28.8 25.8 23.6 23.6 62.5 20.4 38.4 35.4 18.0 15.0 21.5 21.5 100 26.4 35.3 32.3 8.9 5.9 20.1 20.1 155 33.7 32.5 29.5 15.8 200 38.9 30.8 27.8 15.0 Premise Cable Electrical Table 2: Freq. (MHz) Input (Unfitted) Imp. (Ohms) Fitted Impedance Min. ELFEXT (dB) Min. PSELFEXT (dB) 1 100 15 100 15 63.8 60.8 4 100 15 100 15 51.7 48.7 8 100 15 100 15 45.7 42.7 10 100 15 100 15 43.8 40.8 16 100 15 100 15 39.7 36.7 20 100 15 100 15 37.7 34.7 25 100 15 100 15 35.8 32.8 31.25 100 15 100 15 33.9 30.9 62.5 100 15 100 15 27.8 24.8 100 100 15 100 15 23.8 20.8 155 100 25 100 15 19.9 16.9 200 100 25 100 15 17.7 14.7 Notes (Overall) Notes: Jacket sequentially marked at 2 ft. intervals. Third party verified to ANSI/TIA-568-C.2, Category 5e Patch. Put Ups and Colors: Item # Putup Ship Weight Color 1592A F2VU1000 305 MT 9.979 KG GRAY, DEC Notes Item Desc CAT5E PATCH U/UTP CM BOX 1592A F2V1000 305 MT 10.886 KG GRAY, DEC CAT5E PATCH U/UTP CM REEL 1592A 002U1000 305 MT 9.979 KG RED 1592A 0021000 305 MT 10.886 KG RED 1592A 003U1000 305 MT 9.979 KG ORANGE 1592A 0031000 305 MT 10.886 KG ORANGE 1592A 004U1000 305 MT 9.979 KG YELLOW CAT5E PATCH U/UTP CM BOX 1592A 0041000 305 MT 10.886 KG YELLOW CAT5E PATCH U/UTP CM REEL 1592A 005U1000 305 MT 9.979 KG GREEN, DARK 1592A 0051000 305 MT 10.886 KG GREEN, DARK 1592A 006U1000 305 MT 9.979 KG BLUE, LIGHT 1592A 0061000 305 MT 10.886 KG BLUE, LIGHT CAT5E PATCH U/UTP CM BOX C Page 3 of 4 CAT5E PATCH U/UTP CM REEL CAT5E PATCH U/UTP CM BOX C CAT5E PATCH U/UTP CM REEL CAT5E PATCH U/UTP CM BOX C CAT5E PATCH U/UTP CM REEL CAT5E PATCH U/UTP CM BOX C CAT5E PATCH U/UTP CM REEL 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1592A Multi-Conductor - Category 5e Nonbonded-Pair Patch Cable 1592A 007U1000 305 MT 9.979 KG VIOLET 1592A 0071000 305 MT 10.886 KG VIOLET 1592A 009U1000 305 MT 9.979 KG WHITE 1592A 0091000 305 MT 10.433 KG WHITE 1592A 010U1000 305 MT 9.979 KG BLACK 1592A 0101000 305 MT 10.886 KG BLACK CAT5E PATCH U/UTP CM BOX C CAT5E PATCH U/UTP CM REEL CAT5E PATCH U/UTP CM BOX C CAT5E PATCH U/UTP CM REEL CAT5E PATCH U/UTP CM BOX C CAT5E PATCH U/UTP CM REEL Notes: C = CRATE REEL PUT-UP. Revision Number: 4 Revision Date: 08-14-2013 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 4 of 4 10-30-2013