MODEL
RATED CURRENT
RATED POWER
FULL POWER CURRENT RANGE
OUTPUT
CURRENT ADJ RANGE.
VOLTAGE RANGE Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING HUMIDITY
STORAGE TEMP HUMIDITY.,
VIBRATION
OVER TEMPERATURE
47 ~ 63Hz
1.1A / 115 0.5A / 230 0.42A / 277VAC VAC VAC
<0.75mA / 277VAC
20 ~ 95% non-condensingRH
-40 ~ +80 , 10 ~ 95% non-condensing℃RH
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
92.5% 91%
COLD START VAC50A(t =300 s measured at 50% I ) at 230 ;width peakμPer 410NEMA
TOTAL HARMONIC DISTORTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4.2 I/P- :2.1 O/P- :1.5KVAC FG KVAC FG KVAC
I/P-O/P, I/P- , O/P- :100M Ohms / 500 / 25 / 70%FG FG VDC RH℃
CONSTANT CURRENT REGION
MAX NO PSU. . of s on 16A
CIRCUIT BREAKER 8 unit(circuit breaker of type B) / 14 units(circuit breaker of type C) at 230VAC
(Please refer to " " ang “ "section)STATIC CHARACTERISTIC DRIVING METHODS OF LED MODULE
100 ~ 305 142 ~ 431VAC VDC VDC
OPEN CIRCUIT VOLTAGE (max.)
TEMP. COEFFICIENT ±0.03%/ (0 ~ 60 )℃℃
SPECIFICATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated and 25 of ambient temperature.current ℃
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7.Only for XLG-100 I series
8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
11. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 80 or less.
℃
12. Products sourced from the Americas regions may not have the PSE/CCC/BIS/KC logo. Please contact your MEAN WELL sales for more information.
13. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
1006.16K hrs min. Telcordia SR-332 (Bellcore) ; 276.37Khrs min. MIL-HDBK-217F (25 )℃
140 63**32mm (L*W*H)
0.58Kg;24pcs /15Kg /0.85CUFT
100W Constant Power Mode DriverLED XLG-100 series
WORKING TEMP. Tcase=-40 ~ +90 (Please refer to " vs " section)℃OUTPUT LOAD TEMPERATURE
MAX CASE TEMP.. Tcase=+90℃
0.97 / 115 , 0.95 / 230 full loadPF VAC PF VAC≧≧≧, 0.92 / 277 atPF VAC
(Please refer to " " )Power Factor Characteristic section
THD VAC VAC VAC< 10% (@ load 50% at 115 /230 ,@load 75% at 277 )≧≧
Please refer to “ ( )” sectionTOTAL HARMONIC DISTORTION THD
CURRENT RIPPLE 3.0%(@rated current)
CURRENT TOLERANCE ±5%
SET UP TIME 500ms/230 , 1200ms/115VAC VAC
STANDBY
POWER CONSUMPTION
UL8750 ENEC EN61347-1, EN61347-2-13 independent, EN62384(type”HL”), UL879, CSA C22.2 No. 250.13-12; ;
GB19510.1 GB19510.14,; EAC TP TC 004; IP67 approved
100W
700mA
71 ~ 142V
149V
350~1050mA
700~1050mA
XLG-100-L-
100W
2100mA
27 ~ 56V
60V
875~2780mA
1750~2780mA
XLG-100-H-
Hiccup mode, recovers automatically after fault condition is removed
Standby power consumption <0.5W for AB-Type(Dimming OFF)(for standard version)
OVER POWER 105 ~ 150%
INPUT OVER VOLTAGE
Note.7
320 ~ 390 (Shut down output voltage when the input voltage exceeds protection voltage)VAC
can survive input voltage stress of 440Vac for 48 hours
EMC IMMUNITY
EMC EMISSION
Parameter
Conducted
Radiated
Harmonic Current
Voltage Flicker
EN61547
Parameter
ESD
Radiated
EFT/Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
Standard
EN55015(CISPR15)
EN55015(CISPR15)
EN61000-3-2
EN61000-3-3
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Test Level/Note
-----
-----
Class C @load≥50%
-----
Test Level/Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 3
Level 3
4KV/Line-Line 6KV/Line-Earth(6K/10K option)
Level 3
Level 4
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
File Name:XLG-100-SPEC 2019-04-09
Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
Shut down output voltage, re-power on to recover
160 ~ 220V 66 ~ 90V
OVER VOLTAGE