SIL/SMT40C2 Series Data Sheet
Environmental Specications
Thermal performance Operating ambient temperature -0 °C to +70 °C
See Note 5 Non-operating temperature -40 °C to +125 °C
Protection
Short-circuit Hiccup, non-latching
Overvoltage protection Hiccup, non-latching
Recommended System Capacitance
Input See Note 6 0 μF
Output See Note 7 0 μF
Output Voltage Adjustment
The ultra-wide output voltage trim range offers major advantages to users
who select the SIL40C2 series. It is no longer necessary to purchase a variety
of modules in order to cover different output voltages. The output voltage can
be trimmed in a range of 0.6-5 V. When the SIL40C2 converter leaves the
factory, the output has been adjusted to the default voltage of 0.6 V.
Ordering Information
Model
Number (3,5)
Input
Voltage
Output
Voltage
Output Current
(Min.)
Output Current
(Max.)
Efficiency
(Typical)
Regulation
Line Load
SIL40C2-00SADJ-VJ 4.5 - 13.8 Vdc 0.6 - 5 V 0 A 40 A 94% ±0.2% ±0.5%
SIL40C2-00SADJHJ 4.5 - 13.8 Vdc 0.6 - 5 V 0 A 40 A 94% ±0.2% ±0.5%
SMT40C2-00SADJJ 4.5 - 13.8 Vdc 0.6 - 5 V 0 A 40 A 94% ±0.2% ±0.5%
Notes:
1. Measured as per recommended system capacitance.
2. di/dt = 10 A/μs, Vin = Nom, Tc = 25 °C, load change = 0.75 lo to full lo and full lo to 0.75.
3. External input fusing is recommended.
4. Additional part numbers may be available with different output voltages.
5. Airflow dependent, 100 LFM minimum required.
6. No capacitors needed for ripple current stability.
7. No capacitors needed for stability.
8. NOTICE: Some models do not support all options. Please contact your local Artesyn Embedded
Technologies representative or use the on-line model number search tool at
http://www.Artesyn.com/power to find a suitable alternative.
9. To order a Horizontal Mounting option with a pin length of 0.165”, please use model
SIL40C2-00S-HP5.
Part Number System with Options
SIL 40 C 2 - 00 SADJ - V J
Product Family
SIL = Single In Line
SMT = Surface Mount
Output Voltage
Single Adjustable
Output
Performance
C = Cost
Optimized
Input Voltage
00 = 4.5 - 13.8 V
Generation
Blank = Standard
2 = Increased
current density
RoHS Compliance
J = Pb free (RoHS
6/6 compliant)
Mounting Option
V = Vertical
H = Horizontal
(Applicable to SIL
version only)
Rated Output
Current
06 = 6 Amp
15 = 15 Amp
20 = 20 Amp
30 = 30 Amp
40 = 40 Amp
Standard Application Drawing
7,8
10,11
6
9
5
1,2,3
4
SIL40C2
Enable
Vin
GND
Rtrim
(for trim
down)
Cout R
L
O
A
D
Power Good
Vout
+R sense
Cin