RSP-1500 1500W Single Output Power Supply series Features : Universal AC input/Full range ZVS new technology AC input active surge current limiting High efficiency up to 91% Built-in active PFC function,PF>0.95 Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC ball bearing fan Output voltage can be trimmed between 70~100% of the rated output voltage High power density 8.3W/inch3 Current sharing up to 6000W(3+1) Alarm signal output Built-in 12V/0.1A auxiliary output for remote control Built-in remote ON-OFF control Built-in remote sense function 3 years warranty SPECIFICATION MODEL OUTPUT RSP-1500-5 RSP-1500-12 RSP-1500-15 RSP-1500-24 RSP-1500-27 RSP-1500-48 DC VOLTAGE 5V 12V 15V 24V 27V 48V RATED CURRENT 240A 125A 100A 63A 56A 32A CURRENT RANGE 0 ~ 240A 0 ~ 125A 0 ~ 100A 0 ~ 63A 0 ~ 56A 0 ~ 32A RATED POWER 1200W 1500W 1500W 1512W 1512W 1536W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p VOLTAGE ADJ. RANGE 10 ~ 13.5V 13.5 ~ 16.5V 20 ~ 26.4V VOLTAGE TOLERANCE Note.3 INPUT 4.5 ~ 5.5V 2.0% 24 ~ 30V 43 ~ 56V 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 2.0% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1500ms, 100ms at full load HOLD UP TIME (Typ.) 10ms at full load VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47~63Hz POWER FACTOR (Typ.) 0.95/230VAC EFFICIENCY (Typ.) 80% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 17A/115VAC 30A/115VAC LEAKAGE CURRENT <2.0mA / 240VAC 14ms at full load 16ms at full load 127 ~ 370VDC 0.98/115VAC at full load 87% 87% 90% 90% 91% 8A/230VAC 60A/230VAC 105 ~135% rated output power OVERLOAD Note.5 PROTECTION OVER VOLTAGE OVER TEMPERATURE Protection type : Constant current limiting unit will shut down o/p voltage after 5sec. Re-power on to recover 5.75 ~ 6.75V 13.8 ~ 16.8V 17 ~ 20.5V Protection type : Shut down o/p voltage, recovers automatically after temperature goes down 12V@0.1A(Only for Remote ON/OFF control) REMOTE ON/OFF CONTROL Please see the Function Manual Please see the Function Manual Please see the Function Manual WORKING TEMP. -20 ~ +70 TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE (Refer to output load derating curve) 20~90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.05%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) HARMONIC CURRENT EMS IMMUNITY MTBF DIMENSION PACKING NOTE 57.6 ~ 67.2V Please see the Function Manual CURRENT SHARING WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY OTHERS 31 ~ 36.5V AUXILIARY POWER(AUX) FUNCTION ALARM SIGNAL OUTPUT OUTPUT VOLTAGE TRIM (Note 4) 27.6 ~ 32.4V Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW2 ) detect on heatsink of power transistor / 70% RH Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 62.6K hrs min. MIL-HDBK-217F (25 278*127*83.5mm (L*W*H) 3.0Kg; 4pcs/13Kg/1.19CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. http://store.iiic.cc/ File Name:RSP-1500-SPEC 2010-10-18 RSP-1500 1500W Single Output Power Supply Mechanical Specification Case No.943A series Unit:mm 11.2 240 22.7 16 max. 16 83.5 38.1 38 8-M4 L=5(Both Sides) 278 11.2 240 4 17.5 OUTPUT +V 4-M4 L=5 -V CN1 CN2 CN3 86 42 86 42 64 2 75 31 75 31 53 1 I/P LED 93 127 1 SVR 10 Air flow direction 13 2 3 AC Input Terminal Pin No. Assignment Pin No. 1 2 3 Control Pin No. Assignment(CN1,CN2) : HRS DF11-8DP-2DS or equivalent Assignment FG AC/N AC/L Pin No. 1 2 3,5,7 Assignment RCG RC2 -S Pin No. 4 6 8 RCG: Remote ON/OFF Ground RC2: Remote ON/OFF -S : -Remote Sensing Terminal Assignment Mating Housing TRIM HRS DF11-8DS HRS DF11-**SC LS(Current Share) or equivalent or equivalent +S TRIM: Adjustment of Output Voltage LS: Load Share +S: +Remote Sensing Control Pin No. Assignment(CN3) : HRS DF11-6DP-2DS or equivalent Pin No. 1 2 3 Assignment P OK GND P OK RCG Pin No. 4 5 6 P OK GND: Power OK Ground P OK: Power OK Signal RCG: Remote ON/OFF Ground Terminal Assignment Mating Housing AUXG HRS DF11-6DS HRS DF11-**SC RC1 or equivalent or equivalent AUX AUXG: Auxiliary Ground RC1: Remote ON/OFF AUX: Auxiliary Output PFC fosc : 70KHz PWM fosc : 100KHz Block Diagram +S I/P EMI FILTER ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC RECTIFIERS & FILTER POWER SWITCHING +V -V -S PFC CONTROL O.V.P. O.L.P. PWM CONTROL O.T.P. LOAD SHARING AUX POWER http://store.iiic.cc/ DETECTION CIRCUIT P OK REMOTE CONTROL RC LS FAN RECTIFIERS & FILTER AUX POWER (12V/0.1A) File Name:RSP-1500-SPEC 2010-10-18 RSP-1500 1500W Single Output Power Supply Derating Curve series Static Characteristics Ta=25 100 Others +12V,+15V 80 100 90 50 +5V LOAD (%) LOAD (%) 60 40 20 -20 80 70 60 0 10 20 30 40 45 50 60 70 (HORIZONTAL) 90 100 120 140 150 160 180 200 220 240 264 INPUT VOLTAGE (V) 60Hz AMBIENT TEMPERATURE ( ) Function Manual 1.Remote ON/OFF (1)Remote ON/OFF control becomes available by applying voltage in CN1 & CN2 & CN3 (2)Table 1.1 shows the specification of Remote ON/OFF function (3)Fig.1.2 shows the example to connect Remote ON/OFF control function Table 1.1 Specification of Remote ON/OFF Connection Method Fig. 1.2(A) Output on SW Open SW Logic Output off SW Close Fig. 1.2(B) SW Open SW Close Fig. 1.2(C) SW Close SW Open Fig.1.2 Examples of connecting remote ON/OFF (A)Using external voltage source (B)Using internal 12V auxiliary output AUX AUX 2.2K 2.2K RC1 150 12V typ. 5V 150 RC2 12V typ. 620 RC1 RC2 SW RCG RCG SW AUXG AUXG (C)Using internal 12V auxiliary output AUX 2.2K 150 12V typ. RC1 RC2 SW RCG AUXG http://store.iiic.cc/ File Name:RSP-1500-SPEC 2010-10-18 RSP-1500 1500W Single Output Power Supply 2.Alarm Signal Output (1)Alarm signal is sent out through "P OK" & "P OK GND" pins (2)An external voltage source is required for this function. The maximum applied voltage is 50V and the maximum sink current is 10mA (3)Table 2.1 explain the alarm function built-in the power supply Function Description Output of alarm(P OK) The signal is "Low" when the power supply is above Low 65% of the rated output voltage-Power OK (0.5V max at 10mA) P OK High or open The signal turns to be "High" when the power supply (External applied voltage is under 65% of the rated output voltage-Power Fail 10mA max.) series P OK R 0.1uF 100K V P OK GND External voltage and R (The max. Sink is 10mA and 50V) Fig. 2.2 Internal circuit of P OK (Open collector method) Table 2.1 Explanation of alarm 3.Output Voltage TRIM (1)Adjustment of output voltage is possible between 70~100%(Typ.) of the rated output which is shown in Fig. 3.1 (2)Connecting a resistor externally between TRIM and-S on CN1 or CN2 that is shown in Fig. 3.2. Vout 100% CN1 90% TRIM R(0.5W) or 80% CN2 -S 70% R Fig. 3.2 Output voltage trimming 0 470 1.8K OPEN Fig. 3.1 External Resistor (Typical) 4.Current Sharing (1)Parallel operation is available by connecting the units shown as below (+S,-S and LS are connected mutually in parallel): (2)The voltage difference among each output should be minimized that less than 2% is required (3)The total output current must not exceed the value determined by the following equation (Output current at parallel operation)=(The rated current per unit) x (Number of unit) x 0.9 (4) In parallel operation 4 units is the maximum, please consult the manufacture for other applications (5) When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit No.1(Master) V+ +S -S CN1 LS V+S -S CN2 LS AC/L AC/N No.2(Slave) V+ +S -S CN1 LS V+S -S CN2 LS AC/L AC/N +S No.3(Slave) V+ +S -S CN1 LS -S +V -V Load V+S -S CN2 LS AC/L AC/N No.4(Slave) V+ +S -S CN1 LS V+S -S CN2 LS AC/L AC/N http://store.iiic.cc/ File Name:RSP-1500-SPEC 2010-10-18