SIMATIC
BRAUMAT/SISTAR
Readme V7.5 (Online)
Readme
Version: 2018-05-30 (Online)
05/2018
A5E44319741-AA
Security information 1
Overview 2
Installation instructions 3
Notes on Use 4
Virtualization 5
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be
used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property
damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified
personnel are those who, based on their training and experience, are capable of identifying risks and avoiding
potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended or
approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described.
Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in
this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
Siemens AG
Division Digital Factory
Postfach 48 48
90026 NÜRNBERG
GERMANY
A5E44319741-AA
Ⓟ 05/2018 Subject to change
Copyright © Siemens AG 2018.
All rights reserved
Table of contents
1 Security information......................................................................................................................................5
2Overview.......................................................................................................................................................7
3Installation instructions.................................................................................................................................9
3.1 Delivery format.........................................................................................................................9
3.1.1 Delivery package......................................................................................................................9
3.1.2 Licenses and configuration limits.............................................................................................9
3.2 Hardware requirements..........................................................................................................12
3.2.1 PC hardware..........................................................................................................................12
3.2.1.1 Recommended PC hardware configuration...........................................................................12
3.2.1.2 Network..................................................................................................................................13
3.2.2 AS S7-400 hardware..............................................................................................................14
3.2.2.1 HW versions...........................................................................................................................14
3.2.2.2 Settings in HW Config............................................................................................................18
3.2.3 AS S7-1500 hardware............................................................................................................19
3.2.3.1 HW versions...........................................................................................................................19
3.2.3.2 HW device configuration........................................................................................................21
3.3 Software requirements/installation.........................................................................................22
3.3.1 Software installation...............................................................................................................22
3.3.1.1 Requirements.........................................................................................................................22
3.3.1.2 Notes on installing the software.............................................................................................26
3.3.2 Shutting down Windows, standby mode / hibernation...........................................................27
3.3.3 Use of virus scanners.............................................................................................................28
3.3.4 Using Microsoft Office............................................................................................................28
4 Notes on Use..............................................................................................................................................29
4.1 What's new as of V7.5 ?.........................................................................................................29
4.1.1 PCU type S7-1500.................................................................................................................29
4.1.2 Other new features.................................................................................................................30
4.1.3 Obsolete functions.................................................................................................................32
4.1.4 S7 AS blocks..........................................................................................................................33
4.2 SQL adapter option................................................................................................................35
4.2.1 Notes on Use.........................................................................................................................35
4.2.2 Upgrading earlier project solutions.........................................................................................36
4.3 BRAUMAT/SISTAR on IPC427D Microbox RTX...................................................................38
4.3.1 Basics.....................................................................................................................................38
4.3.2 Installation and configuration.................................................................................................39
5 Virtualization...............................................................................................................................................43
5.1 General..................................................................................................................................43
5.2 Hardware and software requirements....................................................................................45
5.3 Licensing................................................................................................................................48
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 3
Table of contents
Readme V7.5 (Online)
4Readme, 05/2018, A5E44319741-AA
Security information 1
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines, and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens’ products and solutions only form one element of such a concept.
Customer is responsible to prevent unauthorized access to its plants, systems, machines and
networks. Systems, machines and components should only be connected to the enterprise
network or the internet if and to the extent necessary and with appropriate security measures
(e.g. use of firewalls and network segmentation) in place.
Additionally, Siemens’ guidance on appropriate security measures should be taken into
account. For more information about industrial security, please visit:
http://www.siemens.com/industrialsecurity.
Siemens’ products and solutions undergo continuous development to make them more secure.
Siemens strongly recommends to apply product updates as soon as available and to always
use the latest product versions. Use of product versions that are no longer supported, and
failure to apply latest updates may increase customer’s exposure to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS
Feed under
http://www.siemens.com/industrialsecurity.
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 5
Security information
Readme V7.5 (Online)
6Readme, 05/2018, A5E44319741-AA
Overview 2
You have obtained the BRAUMAT/SISTAR software with the version V7.5 .
This system offers you appropriate solutions for automation of discontinuous batch processes
in the food and beverage industry.
BRAUMAT/SISTAR is the proven process control system for F&B production plants with the
Siemens "Totally Integrated Automation" concept.
Based on robust SIMATIC S7 and IPC hardware and software components complying with
industry standards
Flexible and simple integration of field devices and drives on the basis of PROFIBUS and
PROFINET
Modular structured and scalable process control system
Openness at all levels
Modern, distributed client-server architecture
Greater availability due to server redundancy
Scalable from a small laboratory system to networks of plants
Efficient, plant-wide engineering
Simple and quick system expansion and optimization in runtime
We wish you every success and hope you enjoy working with BRAUMAT/SISTAR.
Your BRAUMAT/SISTAR team
Note
Read these notes carefully; they contain important information and additional details about
BRAUMAT/SISTAR.
The information provided in this readme file takes precedence over all manuals of the system
documentation.
Note
Complementary to the BRAUMAT control system for control and monitoring of brewing
processes, the scope of delivery starting from Version V7.5 additionally contains an industry-
neutral variant of the control system named SISTAR. By running the corresponding setup
program from the data storage medium, SISTAR can be installed alternatively to BRAUMAT.
This system documentation is generally valid for both systems. In light of this, the product will
be referred to generally as „BRAUMAT/SISTAR“. Isolated uses of the individual terms
BRAUMAT or SISTAR also describe both systems.
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 7
Overview
Readme V7.5 (Online)
8Readme, 05/2018, A5E44319741-AA
Installation instructions 3
3.1 Delivery format
3.1.1 Delivery package
When you order one of the products listed in the following section, you will also receive one
of the following individual components:
Certificate of License CoL
BRAUMAT/SISTAR V7.5 DVD - depending on order number
BRAUMAT/SISTAR V7.5 License Key ALM-USB Memory Stick - depending on order
number
The license keys required to operate the software for the supplied product are located on
the USB memory stick.
To simplify your license management, you can also save the license keys for other SIMATIC
products on this memory stick.
3.1.2 Licenses and configuration limits
The following table describes the available BRAUMAT/SISTAR products as well as their
functional properties:
Product name Article number Basic
license type / Li‐
cense type
Scope of deliv‐
ery
Activated function / application
BRAUMAT,SISTAR IOS
Server 7.5
6DL5210-1BX
57-0YA0
Single
DVD, CoL, ALM
stick
PCU server (server function), recipe server, trend server,
order system server
For redundancy this license is required on both IOS server
PCs.
Operation of all applications except engineering applications
BRAUMAT,SISTAR IOS
Server Upgrade 7.x→7.5
6DL5210-1BX
57-0YE0
BRAUMAT,SISTAR Cli‐
ent 7.5
6DL5210-1CX
57-0YB5
Floating
DVD, CoL, ALM
stick
PCU server (client function)
Operation of all applications except engineering applications
BRAUMAT,SISTAR Cli‐
ent Upgrade 7.x→7.5
6DL5210-1CX
57-0YE5
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 9
Product name Article number Basic
license type / Li‐
cense type
Scope of deliv‐
ery
Activated function / application
BRAUMAT,SISTAR Engi‐
neering 7.5
6DL5210-0AX
57-0YA5
Floating
DVD, CoL, ALM
stick
Parameter assignment/text parameter assignment, image
design, measured value editor, curve entry, ZL synchroni‐
zation, Excel import/export
BRAUMAT,SISTAR Engi‐
neering Upgrade 7.x→7.5
6DL5210-0AX
57-0YE5
BRAUMAT,SISTAR RCS
Server 7.5
6DL5210-1DX
57-2YB0
Single
CoL, ALM stick
RCS server
For redundancy this license is required on both IOS server
PCs.
BRAUMAT/SISTAR RCS
Server Upgrade 7.x→7.5
6DL5210-1DX
57-2YE0
BRAUMAT,SISTAR PCU
7.5
6DL5210-1EX
57-0YB0
Single / Count
relevant
CoL, ALM stick
S7 coupling for 1 PCU (S7-400 or S7-1500)
Note:
For the number <n> PCUs, <n> licenses are required
per IOS server, which means 2 x <n> licenses for a
redundant server pair.
If more PCUs are configured in the plant configuration,
the attempt to establish a connection is rejected.
BRAUMAT,SISTAR PCU
Upgrade 7.x→7.5
6DL5210-1EX
57-0YE0
BRAUMAT,SISTAR SQL
Adapter IOS 7.5
6DL5210-1FX
57-2YB0
Single
CoL, ALM stick
SQL Adapter application
IOS server function
This license is required on each IOS server in case of a
redundant server pair.
BRAUMAT,SISTAR SQL
Adapter IOS 7.x→7.5
6DL5210-1FX
57-2YE0
BRAUMAT,SISTAR SQL
Adapter Server 7.5
6DL5210-1GX
57-2YB0
Single
CoL
SQL Adapter application
SQL DB Host function
BRAUMAT,SISTAR SQL
Adapter Server Upgrade
7.x→7.5
6DL5210-1GX
57-2YE0
BRAUMAT,SISTAR MES
API IOS 7.5
6DL5210-1JX
57-2YB0
Single
CoL, ALM stick
MES-API (Application Programming Interface for MES ap‐
plications)
IOS server function
This license is required on each IOS server in case of a
redundant server pair.
BRAUMAT,SISTAR MES
API IOS Upgrade 7.x→7.5
6DL5210-1JX
57-2YE0
BRAUMAT,SISTAR MES
API Server 7.5
6DL5210-1KX
57-2YB0
Single
CoL
MES-API (Application Programming Interface for MES ap‐
plications)
SQL DB Host function
BRAUMAT, SISTAR MES
API Server Upgrade
7.x→7.5
6DL5210-1KX
57-2YE0
Installation instructions
3.1 Delivery format
Readme V7.5 (Online)
10 Readme, 05/2018, A5E44319741-AA
Product name Article number Basic
license type / Li‐
cense type
Scope of deliv‐
ery
Activated function / application
BRAUMAT,SISTAR Lean
(4 Units) 7.5
6DL5210-1HB
57-0YA0
Single
DVD, CoL, ALM
stick
Includes in limited form 1x IOS server, 1x PCU and 1x En‐
gineering. Access from IOS clients is possible.
If the LEAN license is in use, the following restrictions apply:
Only one Lean license per IOS is used
Only 1 PCU coupling is established (PCU server
connection setup).
Engineering is permitted on this IOS, including where no
Engineering license is present
No RCS server is started (RCS port = disabled),
including where there is an RCS license present
Any potential redundancy switching or server
synchronization is prevented
The Lean license cannot be used on the same station
together with other licenses (IOS Server, IOS Client,
Engineering, PCU).
Important:
The number of units is limited to 4. In the recipe server,
the configuration of the "SEQUENCE" class is checked
accordingly and limited to the use of instances 1..4.
When upgrading from V7.x to V7.5, a
BRAUMAT,SISTAR Lean (16 Units) license is created.
BRAUMAT,SISTAR Lean
Upgrade 7.x→7.5
6DL5210-1HD
57-0YE0
BRAUMAT,SISTAR Lean
PowerPack +12 Units 7.5
6DL5210-1HX
57-0YF0
Single / Power‐
Pack
CoL, ALM stick
Extends an existing Lean license by 12 UNITs. This Power‐
Pack can be used up to 3 times. This enables the following
conversions:
1. BRAUMAT,SISTAR Lean (4 Units) → Lean (16 Units)
2. BRAUMAT,SISTAR Lean (16 Units) → Lean (28 Units)
3. BRAUMAT,SISTAR Lean (28 Units) → Lean (40 Units)
BRAUMAT,SISTAR Con‐
vert Lean (4 Units) → IOS
Server 7.5
6DL5210-1HB
57-0YD0
Single / Power‐
Pack
CoL, ALM stick
Converts an existing Lean (4 Units) license into an IOS
Server license.
ALM stick also contains 1x Engineering and 1x PCU license
BRAUMAT,SISTAR Con‐
vert Lean (16 Units) IOS
Server 7.5
6DL5210-1HD
57-0YD0
Single / Power‐
Pack
CoL, ALM stick
Converts an existing Lean (16 Units) license into an IOS
Server license.
ALM stick also contains 1x Engineering and 1x PCU license
BRAUMAT,SISTAR Con‐
vert Lean (28 Units) IOS
Server 7.5
6DL5210-1HF
57-0YD0
Single / Power‐
Pack
CoL, ALM stick
Converts an existing Lean (28 Units) license into an IOS
Server license.
ALM stick also contains 1x Engineering and 1x PCU license
BRAUMAT,SISTAR Con‐
vert Lean (40 Units) IOS
Server 7.5
6DL5210-1HH
57-0YD0
Single / Power‐
Pack
CoL, ALM stick
Converts an existing Lean (40 Units) license into an IOS
Server license.
ALM stick also contains 1x Engineering and 1x PCU license
Installation instructions
3.1 Delivery format
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 11
3.2 Hardware requirements
3.2.1 PC hardware
3.2.1.1 Recommended PC hardware configuration
Released PC hardware for server and client
We recommend the following configuration for PC components (the higher the quality of the
equipment, the better):
Parameter IOS single station
IOS server
SQL DB host
IOS client
Basic PC (see catalog) SIMATIC IPC 847C / 847D / 647C / 647D / 547D / 547E / 547G
Processor min. INTEL Core 2 Duo; >=2.4GHz, INTEL Core 2 Quad
Work memory (RAM) >= 8 GB (64-bit operating system) >=4 GB (64-bit operating system)
Hard disk
Partition size
>= 500 GB HDD / SSD *1)
C:\ 100 GB
>= 160 GB HDD / SSD
C:\ 100 GB
Network adapter/com‐
munications interfaces
For terminal bus
communication
For plant bus
communication
RJ45 on-board gigabit Ethernet
CP1613 A2 / CP 1623 or BCE
network card
RJ45 on-board gigabit Ethernet
Opt. drive DVD
Parameter
BRAUMAT/SISTAR Lean on IPC 427D Microbox RTX
Basic PC (see catalog) SIMATIC IPC427D with Windows Embedded Standard 7 SP1 and WinAC
RTX 2010 SP2
Processor Intel Core i7-3517UE
Clock rate >=1.2 GHz
Work memory (RAM) 4.0 GB
Hard disk
partition size
>=160 GB HDD / SSD
C:\ 40GB
Network adapter/com‐
munications interfaces
2 x RJ45 on-board Gigabit Ethernet
On-board PROFIBUS CP 5611 / CP 5622
On-board PROFINET CP 1616
Opt. drive External via USB
Purpose BRAUMAT/SISTAR Lean based on SIMATIC IPC427D is approved for AS
and OS operation.
Notice: The use of the "Replay mode" feature is not recommended here.
Installation instructions
3.2 Hardware requirements
Readme V7.5 (Online)
12 Readme, 05/2018, A5E44319741-AA
Note
Note the following:
For IOS server and SQL DB host systems, only the Windows Server operating system
versions (64-bit) are supported.
*1) A hard disk >= 1 TB is recommended when using the "Replay mode" feature.
For Multi-VGA configurations with extensive graphical configuration, we recommend a
relatively high CPU clock frequency. Deactivation of hyper threading in the BIOS of the OS
client can result in a better performance during graphical output.
Using other system hardware
Siemens AG guarantees compatibility between hardware and software for system
configurations based on the hardware components specified.
The system test confirms that the system software of the BRAUMAT/SISTAR process control
system can run on the SIMATIC Industrial Workstations.
Despite extensive testing, it cannot be ruled out that operation of a BRAUMAT/SISTAR system
may be disrupted or impaired by additional software not explicitly approved for BRAUMAT/
SISTAR.
If you use other basic hardware or additional non-system software, you do so at your own
responsibility. If these hardware/software components cause compatibility problems,
troubleshooting support is not free of charge.
Additional information
Internet Link Catalog ST80 (https://mall.industry.siemens.com/mall/en/us/Catalog/Products/
5109999?tree=CatalogTree)
3.2.1.2 Network
Network configuration
The network for the process bus and terminal bus must be isolated via switches, routers or
gateways so that no external interference can enter the network.
Recommendations for this can be found in the document:
Process control system V7.5 function manual, section 1 "Safety Information"
See also
Security concept PCS 7 & WinCC (Basic) (http://support.automation.siemens.com/WW/view/
en/60119725)
Installation instructions
3.2 Hardware requirements
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 13
3.2.2 AS S7-400 hardware
3.2.2.1 HW versions
AS S7-400 CPU types
For the PCU (Programmable Control Unit), the CPU types of the S7-400 series (with the
exception of the CPU-410) are generally permitted.
Installation instructions
3.2 Hardware requirements
Readme V7.5 (Online)
14 Readme, 05/2018, A5E44319741-AA
Note
Planning and selection of the CPU type
Using PCU V7 is only recommended with CPUs as of version 05 for performance reasons.
However, the full configuration limit in connection with the PCU V7 cannot be used with all
CPU types.
We strongly recommend careful planning of the application (new plant or upgrade) and
dimensioning of the configuration limit in connection with the CPU selection.
Using the "Replay mode" feature
Due to the high communication performance requirements, using replay mode can only be
recommended for CPU types in the upper performance segment and of the latest generation.
CPU 416-3 (6ES7416-3XS07-0AB0) / 416-3 PN/DP (6ES7416-3ES07-0AB0)
CPU 417-4 (6ES7417-4XT07-0AB0)
With older CPU generations (in particular before generation "05") even with lower numbers of
TAGs long cycle times are reached and the expectation of extensive coverage of all process
data cannot be met. Replay mode would then have to be limited to a few process diagrams.
The following restrictions apply to the PCU V7 when using CPU types 414 in general as well
as CPU 416/417 < version 07:
With CPU 414, only 2 MB RAM is available for data. However, the complete BRAUMAT/
SISTAR basic system already uses 1750 KB in the delivery project. This means that the
delivery project should be reduced to the necessary range of functions prior to configuring
to create sufficient space for user and control recipe DBs.
The use of the max. 128 units and the max. 9 BLR groups can overload the 100 ms time
slices TS01...TS10 in very extensive configurations and thus cause errors in the recipe
execution.
Solution:
Reduce number of units in the affected PCU (Parameter assignment / "Sequences"
class / Global data / Set "Count" <= 64)
Disable BLR groups that are not used (Parameter assigment / "BLR1"..."BLR9" class /
Global data / Set "DS_CountAct" = 0)
Disable TANK and LINE instances that are not in use
Installation instructions
3.2 Hardware requirements
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 15
Limit the unit user programs, e.g. avoid comprehensive copying instructions
SLB (seat lifting with double seat valve) and PULSE class must not be called in the 100 ms
OB 35 "FB 1224"
Any restrictions are mainly dependent on the size of the TA-/ EOP- user programs as well as
the use of the BLR-groups. The configuration engineer needs to assess based on real HW
whether the use of the relevant CPU type is possible for the required application and make
sure that the available resources, CPU RAM and CPU performance, are adequate. The
measurement of the CPU cycle times in "STEP 7" and the BRAUMAT/SISTAR time slice loads
("CyclMeas" class) under "PLCSim" leads to incorrect results.
Upgrading existing plants
When upgrading from PCU V6 to PCU V7, a dedicated assessment and evaluation of the
following points is necessary:
Upgrading with or without using new functionalities and configuration limits (now and in the
future)
Complexity of the previous configuration
Continued use of existing CPU types
For questions regarding performance requirements and CPU selection, get in touch with your
representative in Product Management (DF FA AS HMI-PRM 2) or SIMATIC Customer
Support.
Table 3-1 Performance data CPU version 05:
CPU type Work memory code /
data
Max. number of DBs /
FBs / FCs
CPU processing times
Bit-Word-INT / REAL
CPU 414-3 PN/DP 2.0 MB / 2.0 MB 6000 / 3000 / 3000 45 ns / 135 ns
CPU 416-2 2.8 MB / 2.8 MB 10000 / 5000 / 5000 30 ns / 90 ns
CPU 416-3 5.6 MB / 5.6 MB 10000 / 5000 / 5000 30 ns / 90 ns
CPU 416-3 PN/DP 8.0 MB / 8.0 MB 10000 / 5000 / 5000 30 ns / 90 ns
CPU 417-4 15.0 MB / 15.0 MB 16000 / 8000 / 8000 18 ns / 54 ns
Table 3-2 Performance data CPU version 07:
CPU type Work memory code /
data
Max. number of DBs /
FBs / FCs
CPU processing times
Bit-Word-INT / REAL
CPU 414-3 PN/DP 2.0 MB / 2.0 MB 6000 / 3000 / 3000 18.75 ns / 37.5 ns
CPU 416-2 4.0 MB / 4.0 MB 10000 / 5000 / 5000 12.5 ns / 25 ns
CPU 416-3 8.0 MB / 8.0 MB 10000 / 5000 / 5000 12.5 ns / 25 ns
CPU 416-3 PN/DP 8.0 MB / 8.0 MB 10000 / 5000 / 5000 12.5 ns / 25 ns
CPU 417-4 16.0 MB / 16.0 MB 16000 / 8000 / 8000 7.5 ns / 15 ns
Installation instructions
3.2 Hardware requirements
Readme V7.5 (Online)
16 Readme, 05/2018, A5E44319741-AA
The following table provides a guide for the memory requirements of typical BRAUMAT/
SISTAR applications:
(Information on earlier CPU versions can be found in earlier Readme files)
Table 3-3 Requirements for CPU version 05
Memory requirement for
data
CPU 414-3
PN/DP
CPU 416-2 CPU 416-3 CPU 416-3
PN/DP
CPU 417-4
CPU RAM data 2000 KB 2800 KB 5600 KB 8000 KB 15000 KB
Basic System PCU V7
static / without control rec‐
ipe DBs
1750 KB 1750 KB 1750 KB 1750 KB 1750 KB
Option RCS Not possible 300 KB
(30 routes)
700 KB
(150 routes)
700 KB
(150 routes)
1200 KB
(300 routes)
Reserve for user and con‐
trol recipe DBs
without RCS
250 KB 1050 KB 3850 KB 6250 KB 13250 KB
Reserve for user and con‐
trol recipe DBs
With RCS option
Not possible 800 KB 3150 KB 5550 KB 12050 KB
Table 3-4 Requirements for CPU version 07
Memory requirement for
data
CPU 414-3
PN/DP
CPU 416-2 CPU 416-3 CPU 416-3
PN/DP
CPU 417-4
CPU RAM data 2000 KB 4000 KB 8000 KB 8000 KB 16000 KB
Basic System PCU V7
static / without control rec‐
ipe DBs
1750 KB 1750 KB 1750 KB 1750 KB 1750 KB
Option RCS Not possible 300 KB
(30 routes)
700 KB
(150 routes)
700 KB
(150 routes)
1200 KB
(300 routes)
Reserve for user and con‐
trol recipe DBs
without RCS
250 KB 2250 KB 6250 KB 6250 KB 14250 KB
Reserve for user and con‐
trol recipe DBs
With RCS option
Not possible 1950 KB 5550 KB 5550 KB 13050 KB
Additional information
PCS 7 catalog Internet link (https://www.automation.siemens.com/mcms/infocenter/content/
en/Pages/order_form.aspx?HTTPS=REDIR&nodeKey=key_518272&infotype=1&linkit=null)
Installation instructions
3.2 Hardware requirements
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 17
3.2.2.2 Settings in HW Config
Settings in HW Config/ CPU properties / memory
The CPU local data of the priority classes should be set according to the table below depending
on the CPU type:
Priority class CPU 414-x
Default / recommended
CPU 416-x
Delivery project
CPU 417-4
Default
Priority 1 758 / 1024 1024 1024
Priority 2 256 / 256 1024 1024
Priority 3 256 / 256 256 1024
Priority 4 256 / 256 256 1024
Priority 5 256 / 256 256 1024
Priority 6 256 / 256 256 1024
Priority 7 0 / 0 1024 1024
Priority 8 0 / 0 1024 1024
Priority 9 758 / 1024 1024 1024
Priority 10 758 / 1024 1024 1024
Priority 11 256 / 1024 1024 1024
Priority 12 758 / 1024 1024 1024
Priority 13 0 / 0 1024 1024
Priority 14 0 / 0 1024 1024
Priority 15 0 / 0 1024 1024
Priority 16 256 / 256 1024 1024
Priority 17 256 / 256 256 1024
Priority 18 256 / 256 256 1024
Priority 19 256 / 256 256 1024
Priority 20 0 / 0 256 1024
Priority 21 0 / 0 256 1024
Priority 22 0 / 0 256 1024
Priority 23 0 / 0 256 1024
Priority 24 256 / 256 1024 1024
Priority 25 256 / 256 1024 1024
Priority 26 758 / 1024 1024 1024
Priority 27 758 / 1024 1024 1024
Priority 28 256 / 1024 1024 1024
Priority 29 256 / 256 256 1024
Occupies xxx bytes 8132 / 11264 20480 29696
of max. bytes 8192 / 16384 *) 22000 32768
*) Maximum value must be adjusted prior to changing the priority classes
Settings in HW Config/ CPU properties / diagnostics / clock
"Acknowledgment-triggered reporting of SFB 33-35" option → disable
Installation instructions
3.2 Hardware requirements
Readme V7.5 (Online)
18 Readme, 05/2018, A5E44319741-AA
Settings in HW Config/ CPU properties / cycle clock memory
"OB1 Update process image cyclically" option → enable
Scan cycle monitoring time → 6000 ms
Size of the process image of the inputs/outputs → 512
"Clock memory" option → enable / MB 0
3.2.3 AS S7-1500 hardware
3.2.3.1 HW versions
AS S7-1500 CPU types
The following CPU types of the S7-1500 series are approved for the PCU (Programmable
Control Unit):
CPU 1518-4 PN/DP 6ES7 518-4AP00-0AB0 (FW version as of V2.5)
CPU 1516-3 PN/DP 6ES7 516-3AN01-0AB0 (FW version as of V2.5)
Installation instructions
3.2 Hardware requirements
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 19
Note
Dependence of the configuration limits on the CPU type
Note the following differences:
CPU 1518-4 PN/DP → Support of the full PCU configuration limits (identical to CPU type
S7-400)
CPU 1516-3 PN/DP → Reduced PCU configuration limits.
The requirements for CPU performance and work memory (data) can only be met with
reduced configuration limits for the "Sequences" (units) and "Tank" classes. For these
reasons, the following measures are required when using this CPU type:
Sequences class: Restriction to instances 1 ... 32
Sequences class: Restriction to the user blocks BmUsrSeq001FC [FC3001] ...
BmUsrSeq032FC [FC3032] in the STEP 7 TIA portal project
Tank class: Restriction to instances 1 ... 32
Class BLR: Unused BLR groups should be disabled (set parameter assignment /
"BLR1"..."BLR9" class / Global data / "DS_CountAct" = 0)
Using the "Replay mode" feature with CPU 1516-3 PN/DP
Due to the high performance requirements for communication, the maximum possible number
of data points (20000 RT and 20000 ENG) per PCU cannot be used here. For these reasons,
the following measures are required when using this CPU type:
The selection of the process diagrams for the process data logging should be defined in
such a way that the following values are not exceeded: Number of data points: Max. 3000
runtime / max. 1000 configuration
Settings of device configuration / CPU properties / Communication load:
The value for "Cycle load from communication" should be set to 30% ... 40%.
Conversion of the delivery project to other CPU types
The STEP 7 delivery project for the S7-1500 contains the full configuration limits with a
CPU of type CPU 1518-4 PN/DP.
The conversion to type CPU 1516-3 PN/DP and the recommended measures for reducing
the configuration limits are described in section "System installation and configuration/AS
installation/Creating an S7-1500 user project".
Buffering in case of power failure
The retentive memory allocated to the complete system program of the delivery project is
greater than the retentive memory volume provided by the CPU alone. To prevent data loss
in the event of a power failure, use of the special backup power supply "PS 60W 24/48/60VDC
HF" is strongly recommended. This is already taken into consideration in the device
configuration of the delivery project.
Installation instructions
3.2 Hardware requirements
Readme V7.5 (Online)
20 Readme, 05/2018, A5E44319741-AA
3.2.3.2 HW device configuration
Settings in the CPU properties
CPU property Setting
PROFINET interfaces [X1] ...
[X3]
The IP address and subnet mask of the process bus connection
must be in accordance with the PCU settings in the IOS server
configuration and must be adapted to the respective project
requirements.
Time synchronization (NTP) must be disabled in the standard
scenario, since it is performed by the IOS server with the
corresponding configuration.
Communication load:
"Cycle load from communication"
CPU 1518-4 PN/DP → 20% (Standard)
CPU 1516-3 PN/DP → should be set to 30% ... 40%
System and clock memory Not required by the system itself
Web server Not required by the system and should remain disabled for security
reasons
Time of day The CPU time zone and the daylight saving time settings are set to
the time zone of the location of use (in Germany: Set UTC +01:00 ...
S/W difference = 60min).
The same setting as in the IOS server must be made here as well
OPC UA Not used by the system
System power supply Since the use of the buffer power supply "PS 60W 24/48/60VDC
HF" is obligatory, the "No connection to supply voltage L+" option
should be activated.
Installation instructions
3.2 Hardware requirements
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 21
3.3 Software requirements/installation
3.3.1 Software installation
3.3.1.1 Requirements
Released operating systems
The following operating systems are supported in BRAUMAT/SISTAR V7.5 :
Windows Embedded Standard 7 SP1 (32Bit)
Windows 7 Ultimate/Enterprise SP1 (64Bit)
Windows 10 Enterprise 2015 LTSB (64Bit)
Windows 10 Enterprise 2016 LTSB (64Bit)
Windows Server 2008 R2 SP1 Standard Edition (64 Bit)
Windows Server 2012 R2 Standard Edition (64 Bit)
Windows Server 2016 Standard Edition (64 Bit)
Not all station types are suitable for every operating system. The following table shows the
assignment of the station types to the operating systems.
BRAUMAT/SISTAR PC Station Windows Em‐
bedded Stand‐
ard 7
32bit SP1
Windows 7
Ultimate / En‐
terprise
64bit SP1
Windows 10
Enterprise
LTSB
64bit
Windows Serv‐
er
Standard
64bit
IOS-Single Station X X X
IOS-Lean Station AS & OS
(IPC 427D / WinAC RTX 2010
SP2)
X
IOS-Server X
IOS-Client X X X
SQL-DB Host X
Released Simatic SW versions
Note:
The SIMATIC software mentioned here is not part of the product package and must be provided
and installed by the customer.
Installation instructions
3.3 Software requirements/installation
Readme V7.5 (Online)
22 Readme, 05/2018, A5E44319741-AA
BRAUMAT/SISTAR V7.5 has been tested with the following versions:
SIMATIC STEP 7 V5.5 (as of SP4) / V5.6 (Windows 10 / Server 2012 / Server 2016)
SIMATIC STEP 7 Professional (TIA Portal) V15
SIMATIC NET IE-Softnet S7 as of V14 SP1
Required on IOS Server or IOS Lean / single station for connection of the process bus
for IOS ↔ AS communication
When the SIMATIC STEP 7 or SIMATIC STEP 7 Professional (TIA Portal) package is
installed on this IOS, SIMATIC NET IE-Softnet S7 is not required.
Microsoft SQL Server 2012 SP1 (64-bit) / Microsoft SQL Server 2014 (64-bit)
Note:
The Microsoft SQL Server software is not part of the "SQL Adapter Server" or "MES API" add-
on package and must be provided and installed by the customer.
The Microsoft SQL Server must be installed before one of these add-on packages is
installed. The "Standard" and "Enterprise" editions are tested and recommended.
The computer name must be set before SQL Server is installed.
The computer name should not be changed afterwards.
(if this is absolutely necessary then special knowledge of SQL is required for this)
Microsoft .NET 4.5.2
The "SQL Adapter Server" or "MES API Server" add-on package requires Microsoft ".NET
4.5.2". If necessary, this is included in the installation automatically by the Setup program.
Notes on installation of the Windows operating system
If a released Windows version is not yet installed on the PC station, reinstall the PC. This
requires the operating system to be changed. The use of tools such as Windows Easy Transfer
to transfer data and settings between different operating systems or to perform a direct upgrade
from Windows Vista to Windows 7 has not been approved.
The following Windows features are not released for use with BRAUMAT:
XP mode (only available with Windows 7)
HomeGroup (only available with Windows 7 and Windows 10)
Parental Control (only available with Windows 7 and Windows 10)
Bit Locker
Fast user switching
The use of this feature can be disabled by the administrator via a group policy. Additional
information on the procedure is available in the function manual section 3.1.1.6 "How to
disable user switching"
Installation instructions
3.3 Software requirements/installation
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 23
Operating multiple monitors
Very long process diagram changing time were observed for some PC stations with multiple
monitors when more than three process diagrams with numerous graphic objects were opened
at the same time.
The cause is related to HW acceleration of the graphics card.
Remedy:
For Windows 7:
Control Panel / Adaptation / Select Aero Design Windows 7 and assign the Braumat
background picture once again.
For Windows Server 2008 R2:
Control Panel / Administrative Tools / Services / Start "Designs" or "Themes" service and
set Startup type to "Automatic".
Control Panel / Adaptation / Select Aero Design Windows 7 and assign the Braumat
background picture once again.
For Multi-VGA configurations with extensive graphical configuration, we recommend a
relatively high CPU clock frequency. Deactivation of hyper threading in the BIOS of the OS
client can result in a better performance during graphical output.
Windows Software Update Service (WSUS)
The WSUS cannot install software versions that are not described in this document as a
minimum system requirements. This includes service packs for Microsoft operating systems,
SQL Server, Office or new versions of Internet Explorer.
For patch management of plant computers running Windows 10, Windows Server 2012 R2
and Windows Server 2016 operating systems, the WSUS server must run on at least Windows
Server 2012 R2.
Operating system languages
We recommend the following Windows MUI operating systems (Multilingual User Interface)
with the following languages and corresponding regional settings:
German
English
Spanish
Chinese (PRC)
To use it, you need to set the desired target language and region consistently at all points in
the Windows language settings. This affects all the settings available under "Regional and
Language Options".
If you are using BRAUMAT/SISTAR in Chinese, make the following settings in the Windows
region and language options:
For the "Language version of the non-Unicode programs" select "Chinese (PRC)"
For the "Language used in menus and dialog", select "English" if you have set the
BRAUMAT/SISTAR language to English.
Installation instructions
3.3 Software requirements/installation
Readme V7.5 (Online)
24 Readme, 05/2018, A5E44319741-AA
For the "Language used in menus and dialog", select "English" or "Chinese (simplified,
PRC)" if you have set the BRAUMAT/SISTAR language to Chinese.
For the "Standards and formats", select "Chinese (PRC)".
You must make these settings before installing the BRAUMAT/SISTAR software.
Rules for computer names
The selection of the computer name is critical for the entire project configuration:
Invalid characters: . , ; : ! ? " ' ^ ´ ` ~ - + = / \ ¦ @ * # $ % & § ° ( ) [ ] { } < > space character,
underscore ("_")
Max. 15 characters
The first character must be a letter.
It is always advisable that only alphanumeric characters are used for the computer name. You
should choose a name consisting of uppercase Latin letters (A-Z) and digits (0-9) only, starting
with a letter and containing a maximum of 15 characters.
Security settings
You can find information on the security settings in the function manual section 3.1.1.4
"Security settings for the PC configuration".
Settings need to be made in the registry and the exception list of the Windows firewall for the
BRAUMAT/SISTAR software to operate correctly.
Before the installation begins, the "Setup - System Settings" dialog appears. There, the system
settings to be changed are listed. To continue the setup, you need to agree to the change to
these system settings.
Note
Please note the following:
The settings in the exception list of the Windows firewall are applied to the area of the local
network (subnet). If your PC stations are located in different networks (subnets), you need
to change this area.
If you need to make individual changes to any of the firewall settings, they should be
adapted afterwards.
The settings in the exception list of the Windows firewall are made when the Windows
firewall is disabled.
See also
Download Link Manual (http://support.automation.siemens.com/WW/view/en/60119725)
KB3156387 (https://support.microsoft.com/en-US/kb/3156387)
Installation instructions
3.3 Software requirements/installation
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 25
3.3.1.2 Notes on installing the software
Requirements
Note the following before installing:
If BRAUMAT/SISTAR software from a previous version prior to V7.0 has already been
installed, the following components must be uninstalled via the Windows Control Panel
"Programs and Features":
BRAUMAT/SISTAR Classic V6.0 SP... Upd ...
BRAUMAT/SISTAR Classic SQL V6.0 + SP2
ILS RCS OFFLINE SERVER V6.0.
The dialog box "Remove shared file?" appears during the uninstall process - confirm
this with "Yes to All" / confirm check query again
If BRAUMAT/SISTAR software V7.0 or higher is already installed, the new version V7.5
can be installed over it.
The Windows Firewall must be active = Windows standard setting
The Windows UAC ("User Account Control") must be active = Windows standard setting,
third stage
Important: Both the setup as well as subsequent operation should be executed in all cases
as a Windows standard user and not as administrator. A user of this type must be created
if not already present.
The Admin User prompt is displayed automatically for all installation/configuration actions
that require Admin rights.
Make sure that no updates are being performed for antivirus software or the Windows
Software Update Services (WSUS) during the installation. You can ensure this by
temporarily disabling the corresponding options in each program.
A Windows UAC query should appear shortly after executing "Setup.exe".
If it does not appear then there is something wrong with the call environment and the setup
may not be able to execute all system registrations.
The setup installs the required sub-components (Microsoft VC/.NET Runtime Libraries as
well as Siemens Automation License Manager ALM).
However, the process bus connection (via STEP 7 or SIMATIC NET Softnet IE) must be
installed separately.
Earlier BRAUMAT/SISTAR SoftCP drivers are no longer supported and should be
uninstalled in the Windows LAN Connections / Properties.
Documentation
The current manual is located on the installation media in the folder "<lw>:....\_Manuals
\English\BraumatSistar_Manual_b.pdf" (for viewing prior to installation).
For further information on the Windows installation see manual section 3.1.1.
For additional information on the BRAUMAT/SISTAR installation, see manual section
3.1.2.
For information on starting the system and the active project, see manual section 3.1.3.
Installation instructions
3.3 Software requirements/installation
Readme V7.5 (Online)
26 Readme, 05/2018, A5E44319741-AA
Installation via network
When performing a network installation on computers with an operating system based on
Windows 7 and Windows Server 2008, ensure that access to the setup is guaranteed, even if
the computer reboots during the setup. There the computer is not in a domain, you must enter
the sign-in information of the user in order to access the network share for the server in the
Windows Credential Manager.
After the installation
Note
Before starting the system, note the following:
Information on separating the system from the project and on taking over projects from
previous versions with the "Management / System settings" tool can be found in section
3.1.3 of the manual.
Failure to observe this information may cause System components of the earlier system
version on the PC. These can interfere with the operation of the new version.
The following entries are available in the Start menu following the installation:
Start→Siemens Automation→BRAUMAT/SISTAR→Application Center (=previously
"NewMenu.exe")
Start→Siemens Automation→BRAUMAT/SISTAR SQL Adapter→ Service Tool (with
corresponding selection in Setup)
The desktop icon is named "Application Center". Icons from previous installations should
be deleted.
In principle, licensing is performed via ALM licenses (see section 3.1.4.).
If there are no ALM licenses available then DEMO mode is activated (with an indication).
This is limited to 4 hours.
The system is located in the Windows programs folder (by default 'c:\Program Files
(x86)\Siemens\Braumat' or 'c:\Program Files (x86)\Siemens\Sistar').
3.3.2 Shutting down Windows, standby mode / hibernation
If you shut down Windows, use the "Shutdown" or "Restart" modes on your PC stations in the
"Start > Power" menu bar.
Do not use "standby mode" and "idle state".
Installation instructions
3.3 Software requirements/installation
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 27
3.3.3 Use of virus scanners
Approved virus scanners
The following virus scanners have been tested for compatibility with BRAUMAT/SISTAR V7.5
and can be installed subsequently even with an existing installation:
Trend Micro OfficeScan V11.0 SP1 (Windows 10 clients are only supported as of this
service pack)
You can find more detailed information on the administration of virus scanners in the "Industry
Online Support" under the following entry:
Internet link (https://support.industry.siemens.com/cs/ww/en/view/38625951)
Statements regarding "PCS 7 and WinCC" also apply to BRAUMAT/SISTAR.
Here you need to pay special attention to the section "Configuration of virus scanners".
3.3.4 Using Microsoft Office
The following Microsoft Office versions have been tested for compatibility with BRAUMAT/
SISTAR V7.5.
Microsoft Office Professional 2010 32-bit SP2 (Excel)
Microsoft Office Professional 2016 32-bit (Excel)
Note:
Note
Using MS Excel
For the "Excel import/export for external configuration" function, only the 32-bit version of
Microsoft Office is supported. This can also be executed on 64-bit operating systems.
Access to project archive files in dBase format (*.dbf) with MS Excel should always be
avoided.
Reason:
dBase files opened with MS Excel cannot be simultaneously used by IOS server processes
(protocol handlers) and there is a risk of data loss.
MS Office should not be used on IOS servers (recipe and RCS servers) since it will
significantly lower the performance.
The operation of MS Office applications can also cause significantly lower performance on
IOS client systems.
Installation instructions
3.3 Software requirements/installation
Readme V7.5 (Online)
28 Readme, 05/2018, A5E44319741-AA
Notes on Use 4
4.1 What's new as of V7.5 ?
4.1.1 PCU type S7-1500
Core statement
In addition to the previously supported S7-400 PCU type, the new CPU generation, S7-1500,
is supported from product version V7.5.
In addition to new and extended functions, the S7-1500 CPU also offers configuration with
the new STEP 7 software for TIA Portal.
Thanks to new editors and central data storage, this enables more efficient and simpler
engineering.
The current S7-1500 system delivery project is configured for the STEP 7 version for TIA
Portal V15.
Functional restrictions in the first release stage with S7-1500
"Route Control System" option is not available for the S7-1500 PCU type
The configuration does not contain any RCS objects
In RCS engineering, the use of the AS-1500 PCU type is excluded
Cross-coupling not available for the S7-1500 PCU type
The configuration does not contain any objects XC_ASTA_RCV, XC_JOB_32, XC_PCU_32
Note: However, a cross-coupling S7-400 <-> S7-1500 can be configured in the application.
Status S7 for the S7-1500 PCU type not available
The disassembly procedure of the MC7 machine code used with S7-400 is not available
for the S7-1500
Online status display (without BLR logic) can only take place in the TIA Portal via monitoring
and force tables.
The application itself and all calls of Status S7 (SeqCtrl, Unit-Ctrl, ICM-OCX, ESG variable)
therefore exclude the S7-1500 PCU type.
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 29
"Weighing and scales" function not available for the S7-1500 PCU type
The GF weigher blocks and parameter assignment (= basic weigher function) are missing
in the delivery project
The TF weigher blocks (= technological function) are missing in the delivery project
The recipe editor and batch management do not support the process input list and
component weighing for this PCU type.
Limited availability of synchronization symbol table for the S7-1500 PCU type
The SEQ/EOP names are completely missing from the TIA Portal symbol table. As a result,
the FB/FC names are also not available in the "ZL Synchronizer" application.
Limited availability of "Simulation" coupling type for the S7-1500 PCU type
The "Simulation" coupling type can be enabled in the PCU server for PCUs of the S7-1500
type, but a simulation similar to the S7-400 is not currently supported.
For example, it is not possible to release the units or start batch processes.
4.1.2 Other new features
Core statement
Here you will find a short description of the other product innovations in the current version,
V7.5.
Division into product versions BRAUMAT and SISTAR
In addition to the BRAUMAT control system for control and monitoring of brewing processes,
the scope of delivery additionally contains an industry-neutral variant of the control system
named SISTAR.
The two product versions differ in the following ways:
By running the corresponding setup program from the data storage medium, SISTAR can
be installed alternatively to BRAUMAT.
The setup checks whether the selected product variant is suitable for pre-installation (if
available). If this is not the case, a message about uninstallation is displayed and the setup
is terminated.
For more information, refer to the respective installation descriptions in the manual.
Installation directories:
"...Program Files (x86)\SIEMENS\Braumat\..."
"...Program Files (x86)\SIEMENS\Sistar\..."
"...Program Files (x86)\SIEMENS\Sistar_SQL\..." ← applies to BRAUMAT and SISTAR
"...ProgramData\SIEMENS\Sistar_SQL\..." ← applies to BRAUMAT and SISTAR
Notes on Use
4.1 What's new as of V7.5 ?
Readme V7.5 (Online)
30 Readme, 05/2018, A5E44319741-AA
Windows Start menu commands:
... Siemens Automation / BRAUMAT / Application Center
... Siemens Automation / SISTAR / Application Center
Application Center icon (desktop, Start menu, etc.): Individual BRAUMAT and SISTAR icon
Application Center plant logo: Individual BRAUMAT and SISTAR default logo
Windows user group (created by Setup)
"BRAUMAT Group" for BRAUMAT installation
"SISTAR Group" for SISTAR installation
S7-400 delivery project:
No difference in block name/icons, block title, block family
S7-1500: Delivery project
Block name "Bm......" → independent of product version
Block family: "BRAUMAT/SISTAR"
Folder structures in the TIA Portal: "...\Braumat/Sistar\..."
OS SW resource properties:
File description, Product name → "BRAUMAT/SISTAR"
BRAUMAT/SISTAR Lean - new license model
For the entry-level product, the number of supported units has been changed as follows:
BRAUMAT/SISTAR Lean (4 Units) → basic package, supports up to 4 units
BRAUMAT/SISTAR Lean PowerPack +12 Units → increases the number of units by 12.
The PowerPack can be used up to 3 times (max. 16, 28, 40 units).
For more information, see section Licenses and configuration limits (Page 9).
Process diagrams: Diagram switching times and number of objects per diagram have been optimized
Several measures in resource management for the "Controls" diagram objects have resulted
in a faster diagram switching compared to the previous version. This is particularly effective
when changing diagrams in complex process diagrams with many diagram objects and when
several process diagram instances are opened simultaneously (multi-monitor operation).
The number of objects per diagram (controls and static variables) has been increased from
512 → 1024.
Excel template for external configuration
The logic configuration of all BLR instances is stored as a hexadecimal string for each instance
in the Excel sheet and can be saved together with the other configuration data for each PCU.
The INKU class has been retrofitted.
Notes on Use
4.1 What's new as of V7.5 ?
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 31
Process data logging/replay mode
The process data logging for line recipes has been extended. DFMs and BLRs for parallel lines
are now logged.
Batch management
When creating a new batch for an order category for which the manual specification of the
batch year is blocked, the batch year is now automatically set to the current year.
New DFM type: Function 12: "Bit mask setpoint/actual"
Function 12 has been added to DFM groups DFM1 - DFM4 - Times, Limits, Decoders (DINT):
When the EOP starts, the setpoint is loaded into the setpoint cell.
The source of the actual value is set in the ActualValueRef parameter.
Difference to mode 6 "Bit mask": The result of the comparison is displayed via the Result
parameter (= DFM flag bit):
Result - TRUE: Actual value = Setpoint
Result - FALSE: Actual value ≠ Setpoint
Sequencer interface: Material compatibility check even when the sequence is not running
A material check can now be processed via the sequencer data record interface even if the
sequence is not in the "Running" state.
4.1.3 Obsolete functions
Discontinued functions
The following functions and contents of the previous versions are no longer supported on newly
installed IOS stations as of BRAUMAT/SISTAR V7.5:
Example application "Free protocols for display and evaluation"
The template directory "<sys-path>\!BM_Proj\Access32\..." with the MS Access example
"Pi_cha32.mdb" is no longer included.
Microsoft MS Access Runtime 2003 is no longer included in the product package.
Notes on Use
4.1 What's new as of V7.5 ?
Readme V7.5 (Online)
32 Readme, 05/2018, A5E44319741-AA
4.1.4 S7 AS blocks
Core statement
All changes made to blocks of the S7-400 AS since the last product version BRAUMAT V7.1.1
are listed below.
Update information V7.5
Block folder BM_USR
PCU V7 user FCs / DBs, which may already contain user configurations. Please apply any
user configurations:
DB689 "BmCurveGroupData"
new "byBatchYear" attribute in UDT502
No transfer to the project required, since there are no interface changes
DB725 "SEQ"
new "SEQ".u.CTRL.xMatCheckReset" attribute in UDT725
Transfer to project only when using the new function "Reset material check"
Notice: Update in the project is required → see text section below
DB727 "AIN"
new "bDecimalPoints" attribute in UDT727
No transfer to the project required, since there are no interface changes
Block folder BM_SYS
PCU V7 FBs, FCs, UDTs, which have been adapted or newly added:
Number Name Last modified AS stop
FB714 BmSeqRunEopFB 2017-11-21 No
FB725 BmSeqFB 2017-11-21 No
FB727 BmMessFB 2018-02-21 No
FB730 BmPidFB 2018-04-16 No
FB737 BmDfm1FB 2017-11-17 No
FB747 BmCurveSetpointsFB 2018-02-05 No
FB750 BmVmonFB 2018-03-09 No
FC505 BmCallMain 2018-03-12 No
FC689 BmTriggerCurveGroupFC 2018-03-12 No
FC695 BmTriggerCurveGroupUsrFC 2018-03-12 No
FC716 BmMsgToFifoFC 2018-01-08 No
FC717 BmSeqXChangeMsgDataFC 2017-11-20 No
UDT502 BmCurveGroupDataUDT 2018-03-12 No
UDT714 BmSeqStatusUDT 2018-11-21 No
UDT715 BmSeqInternUDT 2018-11-21 No
UDT716 BmSeqCtrlUDT 2018-11-21 No
UDT725 SEQ_UDT 2018-11-21 No
UDT727 AIN_UDT 2018-02-21 No
Notes on Use
4.1 What's new as of V7.5 ?
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 33
Update of DB725 ("SEQ") in the project
If the DB725 is already configured, the following update procedure is recommended:
Notice: No unit may be running in the PCU involved for the following steps
Make sure that DB 725 is up-to-date on the IOS (offline DBs); if necessary, save it with
block transfer PCU→IOS
The existing configuration of DB 725 must be imported in the MS Excel configuration /
"Sequences" sheet
Copy DB 725 from the V7 AS delivery project into the STEP 7 project/into the block folder
and load it into the AS
Backup the new DB 725 with block transfer from PCU→IOS
Export to Excel configuration / "Sequences" sheet, i.e. transfer configuration to the new
offline DB 725
Download new offline DB 725 including the configuration with block transfer from IOS→PCU
Notes on Use
4.1 What's new as of V7.5 ?
Readme V7.5 (Online)
34 Readme, 05/2018, A5E44319741-AA
4.2 SQL adapter option
4.2.1 Notes on Use
SQL adapter on the IOS server
After installation/update of the IOS server, a new "Configuration" application with SQL
adapter settings and the IOS component "SQL adapter" itself is available.
The IOS component is not launched until the system has been configured and restarted.
The SQL adapter reads data from dBase files in the project directory. Be sure to avoid
opening these files during operation with independent programs such as Microsoft Excel,
since such programs lock the files against write access by the IOS server processes, which
can lead to data loss.
SQL adapter on the database server
The following configuration tools are available in the Start menu following installation on the
DB host:
Start→Siemens Automation→SISTAR Proxy Manager
Start→Siemens Automation→SISTAR Service Configuration
Using the SQL database
The structure of the SQL database (tables, columns, data types, etc.) is created by the
system services and may not be modified by the user; otherwise, there is a risk of data loss,
inconsistencies, and failed data transfer using the SQL adapter.
User applications may only have read access to the system SQL database; otherwise, there
is a risk of data loss, inconsistencies and failed data transfer.
Since the system SQL tables may change as a result of product enhancements, user
applications and reports should not access these tables directly. Defining views is
recommended instead for example, so that only these views need to be amended in the
event of any changes.
IT security
→ Notes on Windows system and user accounts as well as SQL server settings are available
in the "SQL DB Host" manual, chapter "Installation and configuration / Setup program".
Notes on Use
4.2 SQL adapter option
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 35
Configuration changes
Note
Changing instance names and identifiers in the configuration
In BRAUMAT/SISTAR, names are never used as unique identifiers for recipes, units, etc.
They can be changed at random and at any time because identification always takes place
by means of unique instance IDs.
We generally recommend that you only use these instance IDs as identifiers in higher-level
systems (MIS/MES/ERP).
We also recommend that you do not change the instance names after commissioning
because the non-unique and non-constant names may be used for reporting.
Renaming of BRAUMAT_SQL → SISTAR_SQL
With the current system version, the installation directory of the "BRAUMAT, SISTAR SQL
Adapter Server" add-on package has been changed as follows:
The add-on package is installed in "...Program Files (x86)\SIEMENS\Sistar_SQL\...",
regardless of the product version, BRAUMAT or SISTAR.
If you have pre-installed BRAUMAT_SQL, you will be prompted during setup to uninstall it,
since previously only "BRAUMAT_SQL" was used and in future only "SISTAR_SQL" will
be used.
The configuration settings of the "Sistar Services" and the "Proxy Manager" can be carried
over from the previous installation.
For this, copy the "…ProgramData\Siemens\Braumat_SQL\Sys\*.config" files to "…
ProgramData\Siemens\Sistar_SQL\Sys\*.config". after the installation
4.2.2 Upgrading earlier project solutions
Compatibility, upgrading earlier project solutions
Before the version BRAUMAT/SISTAR V6.0 SP2, certain systems/customers used the
following database connections that were not released as products:
1. the so-called CIS interface
2. BRAUMAT MIS interface (SISTAR SQL connection) - a project-specific predecessor variant
of the "BRAUMAT/SISTAR SQL Adapter" product option presented here.
3. BRAUMAT MES Interface (SISTAR API) - transfer of data from an MES system to
BRAUMAT/SISTAR.
These application solutions used before BRAUMAT/SISTAR V6.0 SP2 are explicitly
incompatible with the product option released here due to changes to the interface and
database.
Notes on Use
4.2 SQL adapter option
Readme V7.5 (Online)
36 Readme, 05/2018, A5E44319741-AA
For 1 and 2:
When upgrading such a system to the current system version, an existing database
connection must be migrated to the current "SQL Adapter" product option. Any customer-
specific database application must be adapted accordingly.
No automatic migration of the database application or of the database itself can be offered
for upgrades.
For 3:
The previous MES interface has not been adapted or tested for the current system version.
For the time being, upgrading a system to the current system version is only possible without
use of the earlier MES interface.
General:
Upgrades for plants with the listed MIS/MES connections (prior to V6.0 SP2) require customer-
specific implementation and must be supported by the Support Center for Breweries where
necessary.
For questions about upgrading database connections before BRAUMAT/SISTAR V6.0 SP2,
contact SIMATIC Customer Support.
Internet link to support pages (https://support.automation.siemens.com)
Notes on Use
4.2 SQL adapter option
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 37
4.3 BRAUMAT/SISTAR on IPC427D Microbox RTX
4.3.1 Basics
What is BRAUMAT/SISTAR Lean on IPC 427D Microbox RTX ?
BRAUMAT/SISTAR Lean on IPC427D Microbox RTX is a complete process control system
consisting of the following components:
Hardware: SIMATIC IPC427D Microbox PC with pre-installed software bundle:
Windows Embedded Standard 7, 32-bit operating system
WinAC RTX 2010 SP2 automation system (internal AS)
SIMATIC NET V12 SP2
Software: BRAUMAT/SISTAR Lean (IOS, PCU, ES) - contains 1x IOS, 1x PCU and 1x
Engineering in a limited form.
Optional: Distributed I/O
This configuration lets you implement a complete process control system with all necessary
components and the standard software at a reasonable price.
Areas of application
This product variant is suitable for the following areas of application:
Autonomous small plants in which multiple AREAs and server redundancy are not required
Package units with integrated operator control and monitoring unit
Testing and training plants
Technical center
Due to the full integration of all standard features, you can take advantage of all the benefits
offered by BRAUMAT/SISTAR . This mainly applies to the following applications:
Construction of a complete "all-in-one" solution consisting of an IOS single station and a
PCU V7
Connection of an external SIMATIC STEP 7 engineering station
Structure of AS-AS cross-coupling via process bus
Connection to the process bus
With the "all-in-one" solution described here, GB ports available as standard (RJ45) of the
IPC427D Microbox PC are required for the connection between the IOS and PCU. These must
be connected either over a switch (when connecting additional process bus stations) or by
means of a crossover patch cable.
A process bus connection as "double bus" is not possible with this solution.
Notes on Use
4.3 BRAUMAT/SISTAR on IPC427D Microbox RTX
Readme V7.5 (Online)
38 Readme, 05/2018, A5E44319741-AA
Connection to a separate terminal bus
If a separate terminal bus is to be used to connect additional IOS clients to a BRAUMAT/
SISTAR Lean Microbox RTX, the Microbox PC must be equipped with an additional PCIe
interface with an Ethernet LAN adapter. Two additional PCIe interfaces with so-called "teaming
capable" Intel LAN adapters are required for a redundant terminal bus.
Note:
This must be taken into consideration when ordering the IPC427D Microbox PC because PCIe
interface cards cannot be installed at a later time.
4.3.2 Installation and configuration
Installation and configuration - IPC427D Microbox PC
Usually the IPC427D Microbox PC is delivered with the pre-installed system configuration
"SIMATIC Embedded Bundles RTX" ready for operation. The special features of this system
configuration are described in the supplied operating manual
"embedded_bundles_ipc_4x7d_operating_manual_<language>.pdf". Only the
"Preconfiguration RTX" is valid for operation with BRAUMAT/SISTAR.
The necessary steps for manual installation are described in the supplied operating instructions
"winac_rtx_2010_manual_<language>.pdf".
In both cases, the recommended settings for operation with BRAUMAT/SISTAR are described
below:
SIMATIC NET settings:
In the Windows Control Panel / "Set PG/PC Interface" , set the S7ONLINE access point to
"TCP/IP(Auto) -> Intel(R) 82574LM Gigabit Network Connection". This is the standard
connection method for automation systems based on WinAC RTX.
Settings in the station configuration editor:
The WinLC RTX controller must be installed in slot 2. An Ethernet controller (e.g. "IF2 -
Intel(R) 82574L Gigabit Network Connection for WinLC RTX") must be configured in the
submodules of this controller.
The station name must correspond to the Windows computer name of the IPC427D.
The Windows LAN Adapter (e.g. "Intel(R) 82574LM Gigabit Network Connection") must be
installed as "IE General" in slot 3.
Any OPC server in slot 1 that may have been pre-installed can remain here, but this is not
required for BRAUMAT/SISTAR.
Settings in the WinLC RTX Control Panel
The settings for operation of the soft PLC can be made in the menu CPU / Properties... The
available settings or properties are also described in the operating instructions
"winac_rtx_2010_manual_<language>.pdf". Only the special features for operation with
BRAUMAT/SISTAR are described below:
Notes on Use
4.3 BRAUMAT/SISTAR on IPC427D Microbox RTX
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 39
General tab
none
Data Storage tab
Activate the option "Save to disk....".
Reason: The retentive data cannot be saved to NVRAM because the BRAUMAT PCU
system blocks already take up more than 128 KB. This means the retentive data can only
be saved to a hard disk with BRAUMAT.
For data security, a UPS is mandatory when saving the retentive data to the hard disk. All
steps required for buffering in case of a power failure with SITOP DC UPS are described
in the Simatic Online Support portal FAQ entry ID 52311477.
PLC memory tab
none
Security tab
none
Submodule tab
The submodules are best configured in the station configuration editor (see above).
Installation and configuration - BRAUMAT/SISTAR
Installation takes place with the setup program and is the same as for other IOS stations.
The following components must be configured within the Administration / Configuration
application:
IOS with the settings:
Name = Windows computer name = station name in the station configuration editor
The TCP/IP address of the Windows network adapter (identical to KoKo IE General in slot
3) must be used.
Route control = inactive, additional options depending on project requirements
PCU with the settings:
Route control = inactive
Connection / slot = 2
Type of connection = TCP/IP
Use the TCP/IP address of the Ethernet controller of the WinLC RTX submodule (e.g. "IF2
- Intel(R) 82574L Gigabit Network Connection for WinLC RTX").
Factory settings
Notice: The "Use CRC" option should be activated in the "S7" tab.
Notes on Use
4.3 BRAUMAT/SISTAR on IPC427D Microbox RTX
Readme V7.5 (Online)
40 Readme, 05/2018, A5E44319741-AA
Note
The number of active UNITs is limited under this license (see section Licenses and
configuration limits (Page 9)).
To comply with this licensing condition, you need to reduce the sequences in the configuration
of the PCU involved. Verification takes place during the recipe server run-up.
If the parameter assignment is incorrect, the message "License Error" appears in the "Recipe
control" diagnostics window of the PCU server.
For this reason, ensure the following parameter assignment before starting:
Parameterization application / "Sequences" class / Data source "Online (PCU)" / Global
data / set "Count" attribute to the number of LEAN UNITs available in the ALM.
Configuration in the STEP 7 project
The IPC427D Microbox PC must be inserted as "SIMATIC PC station" component into the
project.
Its station/computer name must be used as object name for the SIMATIC PC station.
The slot and address information in HW Config must match the settings in the station
configuration editor.
A controller of the type "WinLC RTX" must be installed in slot 2 with the same submodules
as in the station configuration editor (without OPC server).
The Windows LAN adapter must be installed as CP Industrial Ethernet of the type "IE
General" in slot 3.
The TCP/IP addresses of the two LAN adapters (Windows and WinLC RTX) can be
adjusted in the respective setting dialogs.
Note
Settings for the CPU properties of the "WinLC RTX" controller for operation with BRAUMAT/
SISTAR
The "Acknowledgment-triggered reporting of SFB33-35" option must not be selected.
Open the properties dialog of WinLC RTX and select the tab [Diagnostics/Clock].
If necessary, disable the option [Acknowledgement-triggered reporting of SFB 33-35].
Connection configuration with NetPro
You can configure the required subnets with NetPro as well as any required AS-AS cross
connections for the WinLC RTX automation system in the usual way.
Notes on Use
4.3 BRAUMAT/SISTAR on IPC427D Microbox RTX
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 41
Setting the PG/PC interface
For the download function of STEP 7, HW Config and NetPro on the engineering PC, it is
important that the target address on the IPC427D Microbox PC can also be reached.
If S7ONLINE is set to TCP/IP, one of the two TCP/IP addresses of the Microbox PC can
be selected during downloading.
If S7ONLINE is set to ISO, only the MAC address of the Windows LAN adapter can be
selected during downloading.
AS installation
Only the PCU version V7 has been tested and released for the "WinLC RTX" controller.
When assembling the AS software, proceed in the same way as described in the function
manual for the SIMATIC S7-400 standard CPUs (see section "3.2 AS Installation").
Note
Components of the S7-400 delivery project not supported by the "WinLC RTX" controller
The following blocks are not supported by the soft PLC controller:
OB 81 PS_FLT
OB 87 COMM_FLT
OB 101 RESTART
After copying the blocks from the source folder (e.g. Delivery project/"BM_SYS" folder) to the
target folder of the "WinLC RTX" controller, these blocks should be deleted to prevent error
messages during loading.
Notes on Use
4.3 BRAUMAT/SISTAR on IPC427D Microbox RTX
Readme V7.5 (Online)
42 Readme, 05/2018, A5E44319741-AA
Virtualization 5
5.1 General
Fundamentals
BRAUMAT/SISTAR V7.5 is approved for use on virtual machines running VMware vSphere
6.0.
Scope of the release
Virtualization enables several independent virtual machines (VM) to be realized on a physical
computer (host system), each with its own virtual hardware components. VMs behave like real
computers and can run applications themselves.
The following station types are approved for virtual operation based on BRAUMAT/SISTAR
V7.5:
IOS clients
IOS server
IOS single stations
SQL DB host
Important information
Problems that occur during operation on virtual machines are corrected by Siemens if they
can be reproduced in the standard runtime environment (real, non-virtual operating
environment) approved for BRAUMAT/SISTAR. Otherwise we have to assume that the
problem was caused by the virtualization software or the hardware components. In this case,
Siemens unfortunately will not be able to solve the problem. Make sure to take this aspect into
consideration during plant configuration, and contract for the corresponding support services
with your supplier of hardware components and virtualization software.
Also note the following aspects when using the software in virtual operating environments:
Increased system complexity
Additional administrative overhead
Possibly increased security expenditures for the virtual environment (e.g. authorization
concept, data security, patch management)
Risk of a single point of failure (if there is no hardware redundancy in ESX host systems)
Additional license costs for virtualization depending on the range of functions
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 43
Hardware and software requirements
The hardware requirements of VMware vSphere 6.0 apply to the host systems. The host
system is the real hardware on which the ESXi server (hypervisor) runs for the operation of
the virtual machines. This host system makes its resources available to the virtual machines.
Virtualization using "SIMATIC Virtualization as a Service (SIVaaS)"
"SIMATIC Virtualization as a Service (SIVaaS)", for example, allows you to simplify the use of
BRAUMAT/SISTAR in virtual operating environments. Here you obtain an approved complete
system with coordinated sub-components and a comprehensive service package, also for the
components from third-party suppliers.
For sales questions, please contact your Siemens sales representative. Additional information
is available at www.siemens.com/sivaas (https://www.siemens.com/sivaas).
Virtualization
5.1 General
Readme V7.5 (Online)
44 Readme, 05/2018, A5E44319741-AA
5.2 Hardware and software requirements
Virtualization environment
The infrastructure required for the virtualization of BRAUMAT/SISTAR is based on "server-
based virtualization" with the following VMware products:
VMware ESXi V6.0 or higher with VMware vCenter Server V6.0 or higher
VMware vSphere Client V6.0 or higher
ESX server
The ESX server provides the necessary or allocated hardware resources for operation of the
virtual machines. Virtual machines can be created, cloned and configured with the "VMware
vCenter Server" management tool.
The ESX server should meet the following hardware requirements:
Sufficient main memory for the operation of all virtual machines without memory swapping.
Sufficient hard disk space for the operation of all virtual machines.
Sufficient number of network adapters to distribute the communication load and configure
isolated pools of related virtual machines.
The ESX server should have at least two network adapters to separate the communication
load on the client bus on the one hand and on the process bus on the other.
Network adapter 1: VMware client bus and terminal bus communication
Network adapter 2: Process bus
Joint operation on a common LAN adapter can lead to interference of the IOS client / IOS
server / process bus communication and is therefore not recommended.
VMware vSphere client
The VMware vSphere client software is installed and executed on a standard Windows PC.
Any machine from the inventory list of the ESX server can be switched on and operated with
this application. Furthermore, the VM-specific settings can also be changed.
Thin Client
A "Thin Client" can be used as alternative to the Windows PC with VMware vSphere client
software. This is a basic system with screen, keyboard and mouse that can be used to visualize
and operate a specific VM. The internal configuration of the Thin Client determines which virtual
machine is going to be connected.
Virtual network
A virtual network mainly consists of a pool of related VMs, a virtual switch and a real network
card of the ESX server. The configuration of the ESX server determines which elements belong
to the virtual network.
Virtualization with BRAUMAT/SISTAR
Basically, the software and hardware requirements of a virtualized IOS station correspond to
those of a real IOS station.
Virtualization
5.2 Hardware and software requirements
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 45
In addition, the following requirements and restrictions apply to virtualized IOS stations:
Configuration of the VMs
The following table shows the minimum configuration of the VMs using the data listed in the
section Recommended PC hardware configuration (Page 12).
Hard disk vHDD Virt. Core vCPU vRAM [GB] Network adapter
IOS client C:\ 100GB
D:\ 10GB
1 (2) 1) 4 1: Terminal bus
IOS server
IOS single station
C:\ 100GB
D:\ 50GB 3)
2 (4) 2) 8 1: Terminal bus
2: Process bus 4)
SQL DB host C:\ 100GB
D:\ 1TB 3)
4 16 1: Terminal bus
1) A second virtual core (vCPU) is recommended for multi-monitor operation and intensive use
of several process diagram instances.
2) 4 virtual cores are recommended for simultaneous operation of OS/recipe/RCS server,
process data logging and process diagrams/replay mode.
3) The memory expansion for the data partition must be adapted to the requirements of the
project. When using the "Replay mode" feature, a size >= 1 TB is recommended for the archive
path.
4) Process bus communication to the automation system is exclusively via the (virtual) standard
network adapter (SoftNet-IE S7 coupling).
Host operating system
For virtualized IOS stations, the Windows versions listed in the section Requirements
(Page 22) are supported as host operating systems. However, the special "Microsoft Software
License Terms" regarding virtualization for the respective operating system version must be
taken into account.
Installation on a VM
Basically, installation and configuration are performed on a virtual machine in the same way
they are on a real computer. A requirement is that the virtual machine can be connected to a
CD/DVD drive and a USB port. This connection can either be made by using USB drives on
the ESX server or locally on the client device.
Technical restrictions and further Information in the context of virtualization
Only the hardware certified in the VMware Compatibility Guide can be used for the ESXi
server and its components: http://www.vmware.com/go/hcl (http://www.VMware.com/go/
hcl)
Communication modules (e.g. CP1623), multi-monitor graphics card and signal modules
thus cannot be used in the host system.
The host system must provide the virtual machines with sufficient resources even with
increased resource requirements.
Virtualization
5.2 Hardware and software requirements
Readme V7.5 (Online)
46 Readme, 05/2018, A5E44319741-AA
Virtual IOS stations are to be treated like real IOS stations. It follows that:
The virtual stations must be protected as described in the "Security information" manual
in the function manual.
This means, for example, the use of network segmentation, firewalls, virus scanners
and update mechanisms (patch installation via WSUS) must be integrated and
configured as in real installations.
A plant-specific security concept must be implemented.
Virtual stations may not be paused.
The use of snapshots is not permitted during system operation.
VMware options such as vMotion and High Availability (HA) are only supported when using
SIVaaS. Fault tolerance (FT) is not supported in general.
All operating stations can be operated through exactly one open remote connection. This
applies to a remote desktop connection, a RealVNC connection and a connection via a
vSphere Client.
The current Windows session of the locally logged in user must be used for a remote
desktop connection.
Audio signals cannot be transmitted via a RealVNC connection.
No support for redundant terminal bus configurations.
Virtualization
5.2 Hardware and software requirements
Readme V7.5 (Online)
Readme, 05/2018, A5E44319741-AA 47
5.3 Licensing
In regard to licensing, a BRAUMAT/SISTAR software installation on a virtual machine does
not differ from an installation on real hardware (SIMATIC Industrial Workstation).
Therefore, each SIMATIC software installation on a virtual machine, e.g. BRAUMAT/SISTAR
and other SIMATIC applications, must also be licensed.
Virtualization
5.3 Licensing
Readme V7.5 (Online)
48 Readme, 05/2018, A5E44319741-AA