Agilent 8766/7/8/9K Microwave Single-Pole Multi-Throw Switches Product Overview dc to 18, 26.5 GHz Features and description * Exceptional reliability, long life (5,000,000 cycles minimum) * Excellent repeatability * Compact * Easy GPIB implementation for ATE applications * Single-pole, multiple-throw models available: three-throw (8766K) four-throw (8767K) five-throw (8768K) six-throw (8769K) This Agilent Technologies family of single-pole, multiple-throw switches utilizes the same proven technology as the well known Agilent 849X family of step attenuators. These products offer the same rugged reliability, excellent repeatability (typically 0.01 dB to 18 GHz and 0.05 dB to 26.5 GHz), long life (greater than 5 million switching cycles), compactness, and broadband performance as the 849X family. Each product consists of 2 to 5 solenoid driven switching sections connected in series. The solenoid armatures are held in place with permanent magnets able to withstand shocks over 10 g's. The sections switch within 20 milliseconds, including contact settling time, which is of importance for automatic test applications. The switches include self-interrupting contacts which minimize power consumption and simplify the driver circuit design (figure 1). Each model is available with a wide range of solenoid voltage choices (24 volts, standard, or optionally 5 or 15 volts) to match your product or system's requirements. As a section is switched, the internal contacts of the activated coil open, thus shutting off current flow. At the same time, the internal contacts for the other coil close so that it can be activated when desired. Figure 1 shows a section that has been switched to the RF connector position (note the closed thru line coil contact). The switching is "break-before-make" type, thus a momentary interruption of the RF signal occurs at switching. Section switching Although all sections can be switched simultaneously, the attenuator drive must not allow both pins of the same section (e.g., section 1, pins 5 and 6) to be activated concurrently, or else that section would cycle rapidly. All terminals are "floating," so bipolar or unipolar power supplies may be used. Figure 1 shows one switching section schematic. Each section utilizes one solenoid with dual coil windings, one coil to switch in the RF connector, and one coil to switch in the thru line. With a positive voltage applied to the common pin, the state (RF connector or thru line) of a particular section is determined by connecting its RF connector pin or thru pin to a negative voltage or ground. Tables 1 through 4 define the pin assignments for the different switches. Typical driver circuit Figure 1 shows an economical TTL compatible driver circuit for a single switching section utilizing an IC relay driver and an inverter. A TTL "HI" input to the driver switches in the RF connector, while a "LO" will activate the thru line for that section. This provides a complementary driver for the section which assures that only one solenoid of the pair is activated at a time. Diode protection is required to protect the IC from the solenoid voltage flyback. Switch position can be indicated remotely by utilizing the open and closed states of the internal coil contacts. Figure 1 displays two indicator circuits, one providing a TTL output and one that activates an LED. These circuits will output a TTL "HI" (LED lamp "ON") if the RF connector is in the RF circuit, and will output a TTL "LO" (LED lamp "OFF") if the thru line is in the RF circuit. Since current is drawn through the coil for these circuits, inadvertent switching is prevented by limiting the current to 5 mA. LED Inductor Circuit +5V 0.13K 5082-4880 (DM7406N*) (DM7404N*) Figure 1 2 The 11713A includes an integral power supply (with short circuit protection) that can simultaneously provide 125 milliamps at 24 volts to all contacts for control of the atten-uators and switches, so no external power supply is needed. Each 11713A is provided with two (2) plug-in drive cables for the programmable switches to simplify connection to the driver. B RF Connector Drive Pin RF In TTL Indicator Circuit Inverter Typical External Driver Thru Line Drive Pin Internal Coil Contacts (DS75451N*) (DM7404N*) RF Connector Drive Pin (e.g., pin 6) +24V TTL Output More configuration details are available on the Agilent 11713A and 87130A in literature number 5963-2038E. To next Section Drive Cable A * National Semiconductor part numbers, also supplied by other vendors. Note: Additional circuit design information may be required from the component manufacturers. The 87130A is a 3.5 inch high, full width system II attenuator/switch driver capable of driving up to 248 bistatic electromechanical switches or attenuator sections. The 87130A is controlled over GPIB via standard commands for programmable instruments (SCPI) commands. The 87130A has been designed for use in both ATE switching systems and computer controlled bench top applications. 4.22K Switch Drive Circuit Inverter IC Relay Driver GPIB attenuator/switch driver Employing programmable Agilent step attenuators and switches in an automatic test system becomes an easy task when the Agilent 11713A or 87130A attenuator/switch driver is specified into the system. The 11713A has all of the necessary features to provide GPIB control of up to ten switching sections of the 8766/7/8/9 series switches (e.g., five 8766s, two 8769s, etc.). 0.62K Driver +5V The 11713A also features convenient front panel keys so the user can manually activate the individual switch sections when in the "local" mode. Switching time for the drivers is less than 10 milliseconds. Attenuator Section LED TTL Input Agilent assumes no responsibility for the use of any circuits described herein and makes no representation or warranties, express or implied, that such circuits are free from patent infringement. D 4.22K 0.62K Internal Coil Contacts Thru Line Pin (e.g., pin 5) +Voltage (pin 1) to next Section RF Input RF to next Section or Output Thru Line RF to next Section or Output Figure 2 Isolation and insertion loss Specifications Isolation and insertion loss vary with frequency and depend on the port selected, as shown in the chart and tables below. The input connector "C" is always defined as the connector at the opposite end of the switch from the dc drive cable. Frequency range: dc to 26.5 GHz all models or dc to 18 GHz for Option 876xK-002 (SMA connectors) The output ports are numbered sequentially from the input connector. For example, if an 8768K is being used, use the 8768K table to read isolation to each port. If port three (the third connector from the input) is selected, the isolation to ports 1 and 2 will follow curve A. Isolation to port 4 will follow curve B and isolation to port 5 will follow curve C. Reading from figure 3 at 8 GHz, the worst case isolation to ports 1 and 2 will be 30 dB; to port 4, 45 dB; and to port 5, 65 dB. Note that in selecting ports 1 or 2, isolation to disconnected ports can be varied by choosing the position of each section to "thru" or "on." The important thing to note is that, depending on the user's application, port assignments can be important to optimize performance at higher frequencies. All isolation tables refer to figure 3. Maximum SW Frequency (GHz): dc to 8 8 to 12.4 12.4 to 18 18 to 26.5 8766/7/8K 1.3 1.5 1.6 1.8 8769K 1.3 1.55 1.8 2.05 Isolation (dB) 120 80 G F E 60 D 100 C 40 20 B A 0 2 4 6 8 10 12 14 16 Frequency (GHz) 18 20 22 24 26.5 Figure 3. Isolation curves Table 1. Agilent 8766K with switch profile and connector and pin assignments Port selected 1 X = Activated viking cable pin/wire # and color of ribbon pin # ( ) Section status Isolation curve (see table 3) for port # Section 1 Section 2 1 2 1 2 3 6 (2) 5 (13) YEL VIO Conn. Thru X X 8 (5) 7 (11) GRN VLK Conn. Thru X X On On On Off - - B C D B X Off On A - B Off Off A A - 2 X 3 X X Note: Red wire, pin(1) of viking cable, or brown wire, pin(6) of ribbon cable must be connected to + 24 voc. 3 Table 2. Agilent 8767K with switch profile and connector and pin assignments X = Activated viking cable pin/wire # and color or ribbon pin # ( ) Isolation curve (see table 3) for port # Section status Port selected Section 1 Section 2 Section 3 1 2 3 1 2 3 4 1 8 (5) 7 (11) GRN BLK Conn. Thru X X X X 10 (9) 9 (3) BLU ORN Conn. Thru X X X X 6 (2) 5 (13) YEL V/0 Conn. Thru X X X X On On On On On On Off Off On Off On Off - - - - B B C C D E B C E D C B X X X Off Off On On On Off A A - - B C C B Off Off On A A - A Off Off Off A A A - 2 X X X 3 X X 4 X X X X Note: Red wire, pin(1) of viking cable, or brown wire, pin(6) of ribbon cable must be connected to + 24 voc. Table 3. Agilent 8768K with switch profile and connector and pin assignments X = Activated viking cable pin/wire # and color or ribbon pin # ( ) Port selected 1 2 Section status Isolation curve for port # Section 1 Section 2 Section 3 Section 4 1 2 3 4 1 2 3 4 5 12 (10) 11 (4) WHT BRN Conn. Thru X X X X 8 (5) 7 (11) GRN BLK Conn. Thru X X X X 10 (9) 9 (3) BLU ORN Conn. Thru X X X X 6 (2) 5 (13) YEL VIO Conn. Thru X X X X On On On On On On Off Off On Off On Off On On On On - - - - B B C C D E B C E D D B F E E C X X X X X Off Off On On On Off On On A A - - B C D B E C X Off Off On On A A - B C X Off Off Off On A A A - A Off Off Off Off A A A A - X X X 3 X X X 4 X X X 5 X X X X Note: Red wire, pin(1) of viking cable, or brown wire, pin(6) of ribbon cable must be connected to + 24 voc. 4 Table 4. Agilent 8769K with switch profile and connector and pin assignments X = Activated viking cable pin/wire # and color or ribbon pin # ( ) Port selected 1 2 3 Section 1 Section 2 Section 3 Section 4 Section 5 12 (10) 11 (4) WHT BRN Conn. Thru X X X X X X X 8 (5) 7 (11) GRN BLK Conn. Thru X X X X X X X 10 (9) 9 (3) BLU ORN Conn Thru X X X X X X X 6 (2) YEL Thru 5 (13) VIO Thru X X 3 (8) GRY Thru X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 5 X X X 6 X X X X 1 2 3 4 5 1 2 3 4 5 6 X On On On On On On On On On On Off Off Off Off On On Off On Off Off Off On Off On On On Off Off On On On On On On Off - - - - - - - B B B C C C C D D E B C C C E F D D B C C F E E E C B C G F F F E D B X Off Off Off On On On On Off Off On On Off On On Off A A A - - - B C C D B C E C C E F B X Off Off Off Off Off Off On On On On Off Off On On Off A A A A A A - - - B A C C B C E D A 4 (7) WT/RD Thru X X X 4 Isolation curve for port # Section status X X X X Off Off Off Off Off A A A - A C X X Off Off Off Off Off A A A A - B Off Off Off Off Off A A A A A - X Note: Red wire, pin(1) of viking cable, or brown wire, pin(6) of ribbon cable must be connected to + 24 voc. 5 Specifications, continued Ordering information Maximum insertion loss Port 1 0.2 dB +0.05 dB/GHz Port 2 0.2 dB +0.06 dB/GHz Port 3 0.2 dB +0.08 dB/GHz Port 4 0.25 dB +0.095 dB/GHz Port 5 0.25 dB +0.108 dB/GHz Port 6 0.25 dB +0.12 dB/GHz Microwave single-pole multi-throw switches 8766K Single-pole, three-throw 8767K Single-pole, four-throw 8768K Single-pole, five-throw 8769K Single-pole, six-throw Options RF input power (max): 1 watt average, 100 watts peak (10 s pulse width) Life (min): 5 million cycles per section Repeatability: 0.01 dB, typ. to 18 GHz, 0.05 dB, typ. to 26.5 GHz (up to 5,000,000 cycles) Environmental capabilities Temperature, operating: -20C to +75C Temperature, non-operating: -55C to +85C Altitude, operating: 15,000 ft (4,570 meters) Altitude, non-operating: 50,000 ft (13,700 meters) Humidity: Cycling 5 days, 40C at 95% RH with condensation Shock, operating: 10 g's, 6 ms, on six sides, three blows Shock, non-operating: 500 g's, 1.8 ms, in six directions Vibration, operating: 5 g's, 34 to 2000 Hz EMC: Radiated interference is within the requirements of MIL-STD-461B method RE02, VDE 0871, and CTSPR Publication 11. 6 To add options to a product, use the following scheme: Model: 876xK (x = 6, 7, 8, 9) Model options: 876xK-Option 001 876xK-Option 002 Supply voltage (must choose one) 876xK-011 5 V solenoid 876xK-015 15 V solenoid 876xK-024 24 V solenoid (standard option) RF connectors (must choose one) 876xK-002 SMA female connectors 876xK-004 3.5 mm female (standard option) DC connectors (must choose one) 876xK-016 16 inch ribbon cable 876xK-060 5 foot dc control cable; 12 pin "viking" (standard option) Calibration documentation (optional) 876xK-UK6 SWR and insertion loss data measured with an automatic network analyzer with very small uncertainties; directly traceable to NIST standards. Calibration frequencies: 1.5 to 26.5 GHz, every 0.25 GHz. Other combinations can be created for your applications; refer to Agilent Application Note 332-1. Mechanical information Net weight: 8766K 8767K 8768K 8769K 178 grams (6.3 oz) 235 grams (8.3 oz) 292 grams (10.3 oz) 349 grams (12.3 oz) Mounting position: For any orientation, holes are threaded for a metric screw (m 3 x 0.5 x 5.1 deep).A RF connectors: 3.5 mm female (SMA compatible) Option 876xK-002 SMA (for use only to 18 GHz) Switching speed: Maximum 20 msec including settling time Solenoids Coil voltage Switching currentB Nominal coil impedance Standard 24 V (20 to 30 V) 130 mA (at 24 V) 185 Ohms Option 876xK-015 15 V (13 to 22 V) 187 mA (at 15 V) 80 Ohms Option 876xK-011 5V (4 to 7 V) 332 mA (at 5 V) 17 Ohms B. Current per section; approximately 8 msec duration before internal contacts open the coil circuit. Accessory provided (except Option 008 and 016): Solenoid drive plug on 5-foot cable included. (Replacement plug and cable assembly available as part number 8120-2178, except 8769K p/n 5061-0969.) 59.94 (2.360) 45.59 (1.795) 19.43 (0.765) 8.89 (0.35) 25.40 (1.00) 8766K 25.40 (1.00) 83.31 (3.280) 68.96 (2.715) 42.80 (1.685) 16.64 (0.655) 8767K 52.83 (2.088) 81.53 (3.210) 76.2 (3.000) 104.9 (4.13) 110.87 (4.365) 95.12 (3.745) 68.96 (2.715) 42.80 (1.685) 138.38 (5.448) 122.61 (4.827) 96.47 (3.798) 70.31 (2.768) 8768K 103.73 (4.084) 132.3 (5.21) 30.48 (1.20) 7.4 (0.29 C) A 8766/7/8 44.5 (1.75) 8769 49.5 11.4 (1.95) (0.45) 8.89 (0.35) 52.83 (2.088) 11.4 (0.45) 22.9 (0.90) C. This dimension applies to connectore on each end of the switch. Connectors between the ends are 0.05 inches taller. 44.20 (1.740) 19.43 (0.765) 8.89 (0.35) 16.64 (0.655) 8.89 (0.35) 25.40 (1.00) 11.4 (0.45) 8769K 131.32 (5.170) 160.02 (8.300) Figure 4. Dimensions in millimeters and (inches) 7 Agilent Technologies' Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent's overall support policy: "Our Promise" and "Your Advantage." Get the latest information on the products and applications you select. Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. China: (tel) 800 810 0189 (fax) 800 820 2816 Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. By internet, phone, or fax, get assistance with all your test & measurement needs Online assistance: www.agilent.com/find/assist Phone or Fax United States: (tel) 800 452 4844 Canada: (tel) 877 894 4414 (fax) 905 282 6495 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (82 2) 2004 5004 (fax) (82 2) 2004 5115 Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6836 0252 Email: tm_asia@agilent.com Product specifications and descriptions in this document subject to change without notice. (c) Agilent Technologies, Inc. 2002 Printed in USA, May 30, 2002 5959-7831