www.clare.com
2R06
PLA110
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter Min Max Units
Blocking Voltage - 400 VP
Reverse Input Voltage - 5 V
Input Control Current - 50 mA
Peak (10ms) - 1 A
Input Power Dissipation 1- 150 mW
Total Package Dissipation 2- 800 mW
Isolation Voltage, Input to Output 3750 - Vrms
Operational Temperature -40 +85 ºC
Storage Temperature -40 +125 ºC
1 Derate Linearly 1.33 mW / ºC
2 Derate Linearly 6.67 mW / ºC
Absolute Maximum Ratings @ 25ºC
Electrical Characteristics @ 25ºC
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
Continuous, AC/DC Configuration - IL
- - 150 mA
Continuous, DC Configuration - - - 250
Peak t=10ms ILPK - - 400
On-Resistance
AC/DC Configuration IL=150mA RON
--22 Ω
DC Configuration IL=250mA - - 7
Off-State Leakage Current VL=400VPILEAK -- 1 μA
Switching Speeds
Turn-On IF=5mA, VL=10V ton -- 1 ms
Turn-Off toff - - 0.5
Output Capacitance VL=50V, f=1MHz COUT -25 - pF
Input Characteristics
Input Control Current IL=150mA IF-- 5 mA
Input Dropout Current - IF0.4 0.7 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10 μA
Common Characteristics
Input to Output Capacitance - CI/O -3 - pF