Sealed Snap Action Switch D2VW Watertight Miniature Snap Action Switch * High-quality watertight, high-precision miniature Snap Action switch. Switch Body meets IP67 requirements * Use of epoxy resin assures high sealing capability and is ideal for dusty places or where water is sprayed * V-series internal mechanism assures high precision and long life * General-load (5 A at 250 VAC) models and micro-load models are available * RoHS Compliant Ordering Information Actuator Terminal Model 0.1 A Model 5 A Pin plunger With solder and #187 tab terminals D2VW-01-1HS D2VW-5-1HS With lead wires D2VW-01-1MS D2VW-5-1MS With solder and #187 tab terminals D2VW-01L1A-1HS D2VW-5L1A-1HS With lead wires D2VW-01L1A-1MS D2VW-5L1A-1MS With solder and #187 tab terminals D2VW-01L1-1HS D2VW-5L1-1HS With lead wires D2VW-01L1-1MS D2VW-5L1-1MS With solder and #187 tab terminals D2VW-01L1B-1HS D2VW-5L1B-1HS With lead wires D2VW-01L1B-1MS D2VW-5L1B-1MS With solder and #187 tab terminals D2VW-01L3-1HS D2VW-5L3-1HS With lead wires D2VW-01L3-1MS D2VW-5L3-1MS With solder and #187 tab terminals D2VW-01L2A-1HS D2VW-5L2A-1HS With lead wires D2VW-01L2A-1MS D2VW-5L2A-1MS With solder and #187 tab terminals D2VW-01L2-1HS D2VW-5L2-1HS With lead wires D2VW-01L2-1MS D2VW-5L2-1MS Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short hinge roller lever Hinge roller lever Model Note: 1. The standard lengths of the lead wires (UL1015 AWG20 for UL/CSA models, AV0.75f otherwise) of models incorporating them are 300 mm. Add "-0" to the end of the part number to obtain 1,000 mm long wires. (e.g.: D2VW-5L2A-1MS-0) 2. Remove "-HS" from the end of solder/quick-connect models to obtain non-UL/CSA versions. (e.g.: D2VW-01-1HS D2VW-01-1) 3. Remove "S" from the end of lead wire models to obtain non-UL/CSA versions with AV0.75f wire. (e.g.: D2VW-5L3-1MS D2VW-5L3-1M) Model Number Legend D2VW1 2 1. 3 4 Ratings 5: 5 A at 250 VAC 01: 0.1 A at 30 VDC 5 2. Actuator 3. None: Pin plunger L1A: Short hinge lever L1: Hinge lever L1B: Long hinge lever L3: Simulated roller lever L2A: Short hinge roller lever L2: Hinge roller lever Contact Form 1: SPDT 2: SPST-NC 3: SPST-NO 4. Terminals None, HS: Solder terminals (HS for UL and CSA approval.) M, MS: Molded lead wires (MS for UL and CSA approval) 5. Length of the molded lead wire None: 300 mm 0: 1,000 mm Sealed Snap Action Switch D2VW 1 Specifications Characteristics Model Operating speed Operating frequency Insulation resistance Contact resistance Dielectric strength (See note 2) Vibration resistance (See note 3) Shock resistance (See note 3) Degree of protection Degree of protection against electric shock Proof tracking index (PTI) Ambient operating temperature Ambient operating humidity Life expectancy Mechanical Electrical Weight D2VW-01 D2VW-5 0.1 mm to 1 m/s (at pin plunger) Mechanical: 300 operations/minute max. Electrical: 60 operations/minute max. 100 M min. (at 500 VDC) 50 m max. for solder terminal models 100 m max. for 300 mm molded lead wire models 200 m max. for 1,000 mm molded lead wire models 1,000 VAC, 50/60 Hz for 1 min. between terminals of the same polarity 1,500 VAC, 50/60 Hz for 1 min. between each current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts. Malfunction: 10 to 55 Hz, 1.5 mm double amplitude Destruction: 1,000 m/s2 (approx. 100G) max. Malfunction: 300 m/s2 (approx. 30G) max. IEC IP67 (excluding the terminals on terminal models). Class I 175 -40 to 85C (at 60% RH max.) with no icing 95% max. (for 5C to 35C) 10,000,000 operations min. at 60 operations per minute 1,000,000 operations min. at 30 ops. per minute. 100,000 operations min. at 30 ops. per minute Approx. 7g (pin plunger models without wires) Note: 1. Data shown are of initial value. 2. The dielectric strength shown is measured using a separator between the switch and metal mounting plate. 3. For the pin plunger models, the above values apply for use at the free position and total travel position. For the lever models, the values apply at the total travel position. 4. The operating temperature of the lead wire (AV0.75f) for non-UL/CSA molded lead wire models is between -40 to 85C. Ratings (reference values) D2VW-5 Rated Voltage 125 VAC 250 VAC 30 VDC 125 VDC Non-inductive load Resistive load Lamp load NC NO NC NO 5A 0.5 A 5A 0.5 A 5A 3A 0.4 A 0.1 A Inductive load Inductive load Motor load NC NO NC NO 4A -- 4A -- 4A -- 0.4 A -- Non-inductive load Resistive load Lamp load NC NO NC NO 0.1 A -- 0.1 A -- Inductive load Inductive load Motor load NC NO NC NO -- -- D2VW-01 Rated Voltage 125 VAC 30 VDC -- -- Note: 1. The resistive load ratings apply under the following test conditions: Ambient Temperature = 202C, Ambient Humidity = 655%, Operating frequency = 30 operations/min. 2. The above current ratings are the values of the steady-state current. 3. Inductive load has a power factor of 0.7 min. (AC) and a time constant of 7 ms max. (DC). 4. Lamp load has an inrush current of 10 times the steady-state current. 5. Rating for UL/CSA approval is as follows (See "Approved Standards" section): D2VW-01 D2VW-5 2 0.1A @ 125 VAC 0.1A @ 30 VDC 3A @ 125 VAC, 250 VAC Sealed Snap Action Switch D2VW Approved Standards Contact Specifications Consult your OMRON sales representative for specific models with standard approvals. Item Specification Material Gap (standard value) Inrush current UL Recognized, CSA Certified Rated Voltage 125 VAC 250 VAC 30 VDC D2VW-5 3A 3A --- D2VW-01 0.1 A --0.1 A EN 61058-1 (VDE Approval) Rated Voltage 125 VAC 250 VAC D2VW-5 --3A D2VW-01 0.1 A --- D2VW-5 D2VW-01 Rivet Crossbar Silver alloy Gold alloy 0.5 mm NC: 15 A max. --NO: 15 A max. Minimum applicable load 160 mA at 5 VDC 1 mA at 5 VDC (see note) Note: Minimum applicable loads are indicated by N standard reference values. This value represents the failure rate at a 60% (60) reliability level (JIS C5003). The equation 60=0.5 x 10-6 / operations indicates that a failure rate of less than 1/2,000,000 operations can be expected at a reliability level of 60% Testing conditions: 25E3 (25,000 operations), T55 (0C to 55C) for D2VW-5 1E5 (100,000 operations), T85 (0C to 85C) for D2VW-01 Engineering Data Structure SPDT SPST-NC NC (red) NO (blue) COM (black) Note: SPST-NO NC (red) COM (black) NO (blue) COM (black) Colors in parentheses indicate lead wire colors. Mounting All switches may be panel mounted using M3 mounting screws with plane washers or spring washers to securely mount the switch. Tighten the screws to a torque of 0.39 to 0.59 N*m. Two, 3.1-dia. mounting holes or M3 screw holes 10.3 0.1 22.2 0.1 Sealed Snap Action Switch D2VW 3 Dimensions Terminals Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of 0.4 mm applies to all dimensions 2. The pin plunger model is shown here as a typical example for both the solder/quick connect terminals and the molded lead wire versions. Solder/Quick Connect Terminals 2.4 dia. hole Molded Lead Wires 1.3 dia. hole 10.3 AV 0.75f Lead wire (red)* AV 0.75f Lead wire (blue)* AV 0.75f Lead wire (black)* 4.8 1.2 5.2 8.4 0.5 (5) 22.20.1 2.5 5.2 2.8 33 10.3 L 5.2 * UL/CSA approved models have AWG20 UL1015 approved wiring. 22.20.1 2.8 t=0.5 Three, solder terminals 33 300 mm type 300 10 mm L 41.4 1,000 mm type 1,000 30 mm Dimensions and Operating Characteristics Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of 0.4 mm applies to all dimensions 2. Omitted dimensions are the same as pin plunger type. 3. The operating characteristics are for operation in the A direction( ) Pin Plunger Models 2.4 dia. hole D2VW-01-1HS D2VW-5-1HS 1.3 dia. hole 10.3 4.8 1.2 5.2 20.20.25 A 2.5 dia. 2.8 PT OP 8.4 +0.13 3.1 -0.03 dia. holes 0.5 15.9 10.30.1 2.5 5.2 5.2 OF max RF min. PT max. OT min. MD max. OP 200 gf 30 gf 1.2 mm 1.0 mm 0.4 mm 14.7 0.4 mm OF max RF min. PT max. OT min. MD max. OP 200 gf 20 gf 1.6 mm 0.8 mm 0.5 mm 15.2 0.5 mm OF max RF min. PT max. OT min. MD max. OP 120 gf 15 gf 4.0 mm 1.6 mm 0.8 mm 15.2 1.2 mm 3.20.1 dia. +0.13 3.1 -0.03 22.20.1 2.8 t=0.5 Three, solder terminals 33 41.4 Short Hinge Lever Models D2VW-01L1A-1MS D2VW-5L1A-1MS A 24.30.8 t=0.5* 5 4.3 PT OP 15.9 *Stainless-steel lever 10.3 Hinge Lever Models D2VW-01L1-1MS D2VW-5L1-1MS A 35.60.8 t=0.5* 5 4.3 PT OP 15.9 *Stainless-steel lever 4 Sealed Snap Action Switch D2VW 10.3 Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of 0.4 mm applies to all dimensions 2. Omitted dimensions are the same as pin plunger type. 3. The operating characteristics are for operation in the A direction( ) Long Hinge Lever Models D2VW-01L1B-1MS D2VW-5L1B-1MS A 59.40.8 4.3 5 t=0.5* PT OP 15.9 *Stainless-steel lever 10.3 OF max RF min. PT max. OT min. MD max. OP 60 gf 5 gf 9.0 mm 3.2 mm 2.0 mm 15.2 2.6 mm OF max RF min. PT max. OT min. MD max. OP 120 gf 15 gf 4.0 mm 1.6 mm 0.8 mm 18.7 1.2 mm OF max RF min. PT max. OT min. MD max. OP 230 gf 20 gf 1.6 mm 0.8 mm 0.5 mm 20.7 0.6 mm OF max RF min. PT max. OT min. MD max. OP 120 gf 15 gf 4.0 mm 1.6 mm 0.8 mm 20.7 1.2 mm Simulated Roller Lever Models D2VW-01L3-1MS D2VW-5L3-1MS A PT 32.60.8 3.5R t=0.5* 4.3 5 OP 15.9 10.3 *Stainless-steel lever Short Hinge Roller Lever Models D2VW-01L2A-1MS D2VW-5L2A-1MS 4.8 dia. 4.8 ** PT 24.30.8 A 20.10.8 5 t=0.5* 7.2 OP 15.9 *Stainless-steel lever **Oil-less polyacetal resin roller 10.3 Hinge Roller Lever Models D2VW-01L2-1MS D2VW-5L2-1MS A 340.8 4.8 dia. 4.8 ** PT 5 7.2 t=0.5* OP 15.9 *Stainless-steel lever **Oil-less polyacetal resin roller 10.3 Sealed Snap Action Switch D2VW 5 Precautions Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User's Guide, "Snap Action Switches, Technical Information" for correct use. Correct Use Cautions Operations Degree of Protection Make sure that the switching object is perfectly separated from the actuator when the switch is not operated and the actuator is pressed appropriately by the switching object when the switch is operated. The switch should be set so that its stroke will be within the rated OT when the switch is operated. With the pin plunger models, set the switch so that the plunger can be actuated from directly above. Since the plunger is covered with a rubber cap, applying a force from lateral directions may cause damage to the plunger or reduction in the sealing capability. Correct Incorrect Incorrect Do not use the Switch underwater. The switch was tested and found to satisfy the conditions necessary to meet the following standards. However, the test only checks for water intrusion after immersion for a specified time period, not for switching and operation underwater. The switch is tested and conforms to JIS C0920 (Degrees of protection provided by enclosures of electrical apparatus) and IEC60529 (Degrees of protection provided by enclosures). Note: The object to be tested is submerged at a depth of 1 meter for 30 minutes, then checked for water intrusion. Protection Against Chemicals Prevent the switch from coming into contact with oil and chemicals. Otherwise, damage to or deterioration of the switch materials may occur. Handling Handle the switch carefully so as not to break the sealing rubber of the plunger. Using Microloads Voltage (V) Using a model for ordinary loads to switch microloads may result in faulty operation. Instead, use the models that are designed for microloads and that operate in the following range; 30 26mA 100mA 0.16mA 24 Operating range for micro load models D2VW-01 Operating range for general-load models D2VW-05 12 Inoperable range 5 0 1mA 1 100mA 160mA 10 100 1,000 Current (mA) However, even when using microload models within the operating range shown above, if inrush current or inductive voltage spikes occur when the contact is opened or closed, then contact wear may increase and so decrease the service life. Therefore, insert a contact protection circuit where necessary. Soldering - Connecting to Solder Terminals When soldering the lead wire to the terminal, first insert the lead wire conductor through the terminal hole and then conduct soldering. Complete the soldering at the iron tip temperature between 350 to 400 C within 3 seconds, and do not apply any external force for 1 minute after soldering. Soldering at an excessively high temperature or soldering for more than 3 seconds may deteriorate the characteristics of the switch. Mounting Use M3 mounting screws with plane washers or spring washers to securely mount the switch. Tighten the screws to a torque of 0.39 to 0.59 N*m ( 4 to 6 kgf*cm) 6 Sealed Snap Action Switch D2VW MEMO Sealed Snap Action Switch D2VW 7 All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com OMRON ELECTRONIC COMPONENTS LLC 847-882-2288 Cat. No. C095-E-05 8 09/14 (11/10) Sealed Snap Action Switch Specifications subject to change without notice D2VW Printed in USA