www.recom-power.com REV.: 4/2018 ECO-1
Features
Unregulated
Converters
High isolation 2W converter
3kVDC and 4kVDC basic isolation
UL94V-0 package material
Optional continuous short circuit protected
Efficiency up to 84%
Suitable for IGBT applications
RKZ
Description
The RKZ Series of 2W DC/DC Converters are certified to EN60950-1. This makes them suitable for high
end industrial applications such as IGBT driver circuitry. The RKZ converters are pin-compatible with the
RK and RH converter series, offering a simple way to upgrade a 1W high isolation supply to 2W.
DC/DC Converter
2 Watt
SIP7
Single and
Dual Output
E358085
UL60950-1 certified
CSA C22.2 No. 60950-1-07 certified
IEC/EN60950-1 certified
EN55032 compliant
www.recom-power.com/eval-ref-boards
Selection Guide
Part nom. Input Output Output Efficiency max. Capacitive
Number Voltage Voltage Current typ.
(1) Load
(2)
[VDC] [VDC] [mA] [%] [µF]
RKZ-xx05S (3,4) 5, 12, 24 5 400 82-84 1500
RKZ-xx12S (3,4) 5, 12, 24 12 168 82-87 330
RKZ-xx15S (3,4) 5, 12, 24 15 132 82-84 330
RKZ-xx05D (3,4) 5, 12, 24 ±5 ±200 70-83 ±680
RKZ-xx12D (3,4) 5, 12, 24 ±12 ±84 82-84 ±220
RKZ-xx15D (3,4) 5, 12, 24 ±15 ±66 82-88 ±220
RKZ-xx1509D (3,4) 5, 12, 24 +15/-9 +67/-111 70-81 ±330
Model Numbering
Notes:
Note3: standard part is without Continuous Short Circuit Protection
add suffix „/P“ for Continuous Short Circuit Protection
Note4: add suffix „/H“ for 4kVDC Isolation
or add suffix „/HP“ for 4kVDC Isolation and Continuous Short Circuit Protection
Ordering Examples:
RKZ-0515S/P: 5VDC Input Voltage, 15VDC Output Voltage, Single Output with continuous short circuit protection
RKZ-0515D/HP:
5VDC Input Voltage, ±15VDC Output Voltage, Dual Output with continuous short circuit protection and 4kVDC isolation
nom. Input Voltage
Output Voltage
RKZ- __ /
Protection (3)
Isolation Option (4)
Single or Dual
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the
capacitive load that will allow start up in under 1s without damage to the converter
www.recom-power.com REV.: 4/2018 ECO-2
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RKZ
Series
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Internal Input Filter capacitor
Input Voltage Range ±10%
Minimum Load (5) 0%
Internal Operating Frequency all others
RKZ-xx1509D
20kHz
20kHz
50kHz
51kHz
85kHz
Output Ripple and Noise 20MHz BW 150mVp-p
continued on next page
Notes:
Note5: Operation below 10% load will not harm the converter, but specifications may not be met
Efficiency vs. Load
RKZ-xx05S
RKZ-xx15S
RKZ-xx12S
RKZ-xx05D
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0505
1205
2405
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0515
1215
2415
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0512
1212
2412
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0505
1205
2405
www.recom-power.com REV.: 4/2018 ECO-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RKZ
Series
REGULATIONS
Parameter Condition Value
Output Accuracy ±5.0% max.
Line Regulation low line to high line ±1.2% of 1.0% Vin typ.
Load Regulation 10% to 100% load 5Vout
12, 24Vout and RKZ-xx1509D
15.0% max.
10.0% max.
continued on next page
Efficiency vs. Load
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0512
1212
2412
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0515
1215
2415
RKZ-xx12D RKZ-xx15D
Deviation vs. Load
25
15
5
-50
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0505
1205
2405
25
15
5
-50
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0512
1212
2412
RKZ-xx05S RKZ-xx12S
www.recom-power.com REV.: 4/2018 ECO-4
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RKZ
Series
25
15
5
-50
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0515
1215
2415
25
15
5
-50
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0512
1212
2412
25
15
5
-50
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0505
1205
2405
25
15
5
-50
20
10
0
-10
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
0515
1215
2415
RKZ-xx15S RKZ-xx05D
Accuracy vs. Load
RKZ-xx12D RKZ-xx15D
PROTECTIONS
Parameter Type Value
Short Circuit Protection (SCP) without suffix
with suffix “/P”
1 second
continuous
Isolation Voltage (6) I/P to O/P
without suffix tested for 1 second
rated for 1 minute
3kVDC
1.5kVAC / 60Hz
with suffix “/H” tested for 1 second
rated for 1 minute
4kVDC
2kVAC / 60Hz
Isolation Resistance 10G min.
Isolation Capacitance 120pF max.
Insulation Grade basic
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is required. Recommended fuse: slow blow type
www.recom-power.com REV.: 4/2018 ECO-5
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RKZ
Series
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range full load @ free air convection (see graph) -40°C to +85°C
Maximum Case Temperature +110°C
Temperature Coefficient ±0.03%/K typ.
Thermal Impedance 40K/W typ.
Operating Altitude 2000m
Operating Humidity non-condensing 95% RH max.
Pollution Degree PD2
MTBF according to MIL-HDBK-217F, G.B. +25°C
+85°C
18300 x 103 hours
8070 x 103 hours
-40 -20 0 20 40 7060-30 -10 10 30 50 80 90
85
110100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
Derating Graph
(@ free air convection)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
Information Technology Equipment, General Requirements for Safety
1602031 IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
Information Technology Equipment, General Requirements for Safety E358085-A4-UL UL60950-1, 2nd Edition:2007
CAN/CSA C22.2 No. 60950-1-03, 2nd Edition:2007
EAC RU-AT.49.09571 TP TC 004/2011
RoHs 2+ RoHS-2011/65/EU + AM-2015/863
EMC Compliance Condition Standard / Criterion
Information technology equipment - Radio disturbance
characteristics - Limits and methods of measurement with external filter EN55032, Class A
EN55032, Class B
continued on next page
www.recom-power.com REV.: 4/2018 ECO-6
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RKZ
Series
EMC Filtering Suggestions according to EN55032
C1
+VIN
-VIN
+VOUT
-VOUT
C1
L1
+VIN
-VIN
+VOUT
-VOUT
C3
C2
Component List Class B
Model L1 C1 C2 (safety) C3 (safety)
5Vout 12µH, PR4532Z-120K 10µF
100V, MLCC
470pF
5kV
1nF
5kV
12, 15Vout 22µH, PR4532Z-220K
Component List Class A
Class A Class B
Model L1 C1 C2 C3
all types NA 10µF
100V, MLCC NA NA
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Material case
potting
Package Dimension (LxWxH) 19.65 x 7.05 x 10.2mm
Package Weight 2.8g typ.
Pinning information
Pin # Single Dual
1 +Vin +Vin
2 -Vin -Vin
5 -Vout -Vout
6 no pin Com
7 +Vout +Vout
Bottom View
0.5
1.27
10.2
0.5+0.10/-0.05 0.25±0.05
7.05
19.65
embossed Logo
6 x 2.54 =15.24
4 x 2.54 = 9.65
2.00
12 567
2.54
2.54
4.10
Bottom View
1 2 5 7
Marking
Top View
12 567
Dimension Drawing (mm)
Recommended Footprint Details
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
www.recom-power.com REV.: 4/2018 ECO-7
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RKZ
Series
INSTALLATION AND APPLICATION
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) tube 520.0 x 16.0 x 9.0mm
Packaging Quantity tube 25pcs
Storage Temperature Range -55°C to + 125°C
Storage Humidity 95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.
IGBT Application Circuit
DC
DC
IGBT Driver
C1
R1
Q1
E
C
G
C3
C2
+Vin
+Vin
-Vin
-Vin
+Vout
Signal-
Signal+
-Vout
IN OUT
IC2
IC1
+