Bulletin PD-20753 rev. D 07/01 MURS120 Ultrafast Rectifier trr = 25ns IF(AV) = 1Amp VR = 200V Features * * * * Ultrafast Recovery Time Low Forward Voltage Drop Low Leakage Current 175C Operating Junction Temperature SMB Description/ Applications International Rectifier's MUR.. series are the state of the art Ultra fast recovery rectifiers specifically designed with optimized performance of forward voltage drop and ultra fast recovery time. The planar structure and the platinum doped life time control, guarantee the best overall performance, ruggedness and reliability characteristics. These devices are intended for use in the output rectification stage of SMPS, UPS, DC-DC converters as well as freewheeling diode in low voltage inverters and chopper motor drives. Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over dissipation in the switching element and snubbers. Absolute Maximum Ratings Parameters Max Units VRRM Peak Repetitive Peak Reverse Voltage 200 V IF(AV) Average Rectified Forward Current, T L = 158C 1 A IFSM Non Repetitive Peak Surge Current 40 TJ, TSTG Operating Junction and Storage Temperatures - 65 to 175 CATHODE 2.15 (.085) 1.80 (.071) 3.80 (.150) 3.30 (.130) 1 ANODE 2 1 POLARITY 4.70 (.185) C 2 PART NUMBER 4.10 (.161) 2.5 TYP. (.098 TYP.) 2.40 (.094) 1.90 (.075) 1.30 (.051) 0.76 (.030) 0.30 (.012) 0.15 (.006) 5.60 (.220) 5.00 (.197) 2.0 TYP. (.079 TYP.) SOLDERING PAD 4.2 (.165) 4.0 (.157) Outline SMB Dimensions in millimeters and (inches) www.irf.com 1 MURS120 Bulletin PD-20753 rev. D 07/01 Electrical Characteristics @ TJ = 25C (unless otherwise specified) Parameters Min Typ Max Units Test Conditions VBR, Vr Breakdown Voltage, Blocking Voltage 200 VF Forward Voltage - 0.83 0.875 - 0.65 0.71 V I F = 1A, TJ = 150C IR Reverse Leakage Current - 0.1 2 A V R = VR Rated - 11 50 A T J = 150C, VR = VR Rated - 12 - pF V R = 200V CT Junction Capacitance - - V I R = 100A V I F = 1A Dynamic Recovery Characteristics @ TJ = 25C (unless otherwise specified) Parameters t rr Min Typ Max Units Test Conditions Reverse Recovery Time - - 35 - - 25 ns I F = 1.0A, di F /dt = 50A/s, V R = 30V I F = 0.5A, I R = 1.0A, I REC = 0.25A Thermal - Mechanical Characteristics Parameters 2 Min Typ Max Units TJ Max. Junction Temperature Range - - 175 C TStg Max. Storage Temperature Range - 65 - 175 RthJL Thermal Resistance, Junction to Lead - - 21 Wt Weight - 0.1 - g - 0.07 - (oz) C/W www.irf.com MURS120 Bulletin PD-20753 rev. D 07/01 Reverse Current - I R (A) 100 150C 10 125C 1 100C 0.1 0.01 25C 0.001 T = 175C J 0 T = 150C J 1 Tj = 175C 40 80 120 160 Reverse Voltage - VR (V) 200 Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage T = 25C J 100 Tj = 25C Junction Capacitance - C T (pF) Instantaneous Forward Current - I F (A) 10 0.1 0.4 10 0.6 0.8 1 1.2 1.4 Forward Voltage Drop - VFM (V) Fig. 1 - Typical Forward Voltage Drop Characteristics 0 40 80 120 160 200 Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage Thermal Impedance Z thJL (C/W) 100 10 1 D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01 PDM t1 t2 Single Pulse (Thermal Resistance) Notes: 1. Duty factor D = t1/ t2 2. Peak Tj = Pdm x ZthJC+ Tc 0.1 0.001 0.01 0.1 1 10 t1, Rectangular Pulse Duration (Seconds) Fig. 4 - Max. Thermal Impedance Z thJC Characteristics www.irf.com 3 MURS120 Bulletin PD-20753 rev. D 07/01 1 Average Power Loss ( Watts ) Allowable Lead Temperature (C) 180 170 DC 160 Square wave (D = 0.50) Rated Vr applied 150 0.8 RMS Limit 0.6 D = 0.01 D = 0.02 D = 0.05 D = 0.1 D = 0.2 D = 0.5 DC 0.4 0.2 see note (3) 140 0 0 0.4 0.8 1.2 0 1.6 Average Forward Current - I F (AV) (A) 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 Average Forward Current - I F (AV) (A) Fig. 5 - Max. Allowable Lead Temperature Vs. Average Forward Current Fig. 6 - Forward Power Loss Characteristics 100 10 Tj = 25C Qrr ( nC ) trr ( ns ) Tj = 25C 10 Vr = 30V If = 1A Vr = 30V If = 1A 1 100 1000 1000 di F /dt (A/s ) di F /dt (A/s ) Fig. 7 - Typical Reverse Recovery vs. di 1 100 F /dt Fig. 8 - Typical Stored Charge vs. di F /dt (3) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = rated VR 4 www.irf.com MURS120 Bulletin PD-20753 rev. D 07/01 Tape & Reel Information Dimensions in millimeters and (inches) Marking & Identification Ordering Information Each device has 8 characters, configurated 4 digits on two rows, for identification. The first row designates the device as manufactured by International Rectifier as indicated by the letters "IR", and the Part Number ( indicates the current rating and voltage/process). The second row indicates the year and the week of manufacturing. MURS SERIES - TAPE AND REEL WHEN ORDERING, INDICATE THE PART NUMBER AND THE QUANTITY ( IN MULTIPLES OF 3000 PIECES). EXAMPLE: MURS120TR - 6000 PIECES MURS.. SERIES - BULK QUANTITIES WHEN ORDERING, INDICATE THE PART NUMBER I R 1Q Voltage/ Process M N P Q R S T V Current Rating (1A) IR logo YY WW = = = = = = = = 50 V 100 V 150 V 200 V 300 V 400V 500V 600V AND THE QUANTITY ( IN MULTIPLES OF 250 PIECES). EXAMPLE: MURS120 - 500 PIECES (Date Code) Week Year www.irf.com 5 MURS120 Bulletin PD-20753 rev. D 07/01 Ordering Information Table Device Code MUR S 1 20 1 2 3 4 1 - Ultrafast MUR Series 2 - Package Style: SMB 3 - Current Rating (1 = 1A) 4 - Voltage Rating (20 = 200V) Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level. Qualification Standards can be found on IR's Web site. IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 07/01 6 www.irf.com