74LVC2G17 Dual non-inverting Schmitt trigger with 5 V tolerant input Rev. 9 -- 15 December 2016 Product data sheet 1. General description The 74LVC2G17 provides two non-inverting buffers with Schmitt trigger input. It is capable of transforming slowly changing input signals into sharply defined, jitter-free output signals. Inputs can be driven from either 3.3 V or 5 V devices. This feature allows the use of these devices as translators in a mixed 3.3 V and 5 V environment. This device is fully specified for partial power-down applications using IOFF. The IOFF circuitry disables the output, preventing the damaging backflow current through the device when it is powered down. 2. Features and benefits Wide supply voltage range from 1.65 V to 5.5 V 5 V tolerant input/output for interfacing with 5 V logic High noise immunity Complies with JEDEC standard: JESD8-7 (1.65 V to 1.95 V) JESD8-5 (2.3 V to 2.7 V) JESD-8B/JESD36 (2.7 V to 3.6 V) ESD protection: HBM JESD22-A114F exceeds 2000 V MM JESD22-A115-A exceeds 200 V 24 mA output drive (VCC = 3.0 V) CMOS low-power consumption Latch-up performance exceeds 250 mA Direct interface with TTL levels Multiple package options Specified from 40 C to +85 C and 40 C to +125 C 3. Applications Wave and pulse shapers for highly noisy environments 74LVC2G17 Nexperia Dual non-inverting Schmitt trigger with 5 V tolerant input 4. Ordering information Table 1. Ordering information Type number Package Temperature range Name Description Version 74LVC2G17GW 40 C to +125 C SC-88 plastic surface-mounted package; 6 leads SOT363 74LVC2G17GV 40 C to +125 C TSOP6 plastic surface-mounted package (TSOP6); 6 leads SOT457 74LVC2G17GM 40 C to +125 C XSON6 plastic extremely thin small outline package; no leads; 6 terminals; body 1 1.45 0.5 mm SOT886 74LVC2G17GF 40 C to +125 C XSON6 plastic extremely thin small outline package; no leads; 6 terminals; body 1 1 0.5 mm SOT891 74LVC2G17GN 40 C to +125 C XSON6 extremely thin small outline package; no leads; 6 terminals; body 0.9 1.0 0.35 mm SOT1115 74LVC2G17GS 40 C to +125 C XSON6 extremely thin small outline package; no leads; 6 terminals; body 1.0 1.0 0.35 mm SOT1202 5. Marking Table 2. Marking codes Type number Marking code[1] 74LVC2G17GW VV 74LVC2G17GV VV 74LVC2G17GM VV 74LVC2G17GF VV 74LVC2G17GN VV 74LVC2G17GS VV [1] The pin 1 indicator is located on the lower left corner of the device, below the marking code. 6. Functional diagram $ < $ < PQE Fig 1. Logic symbol 74LVC2G17 Product data sheet PQE Fig 2. IEC logic symbol All information provided in this document is subject to legal disclaimers. Rev. 9 -- 15 December 2016 (c) Nexperia B.V. 2017. All rights reserved 2 of 19 74LVC2G17 Nexperia Dual non-inverting Schmitt trigger with 5 V tolerant input $ < $ < PQE Fig 3. Logic diagram 7. Pinning information 7.1 Pinning /9&* /9&* $ *1' 9&& $ < < $ < *1' 9&& $ Pin configuration SOT363 and SOT457 $ < *1' 9&& $ < < DDI DDI 7UDQVSDUHQWWRSYLHZ DDI Fig 4. /9&* Fig 5. Pin configuration SOT886 7UDQVSDUHQWWRSYLHZ Fig 6. Pin configuration SOT891, SOT1115 and SOT1202 7.2 Pin description Table 3. Pin description Symbol Pin Description 1A 1 data input GND 2 ground (0 V) 2A 3 data input 2Y 4 data output VCC 5 supply voltage 1Y 6 data output 8. Functional description Table 4. Function table[1] Input Output nA nY L L H H [1] H = HIGH voltage level; L = LOW voltage level. 74LVC2G17 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 9 -- 15 December 2016 (c) Nexperia B.V. 2017. All rights reserved 3 of 19 74LVC2G17 Nexperia Dual non-inverting Schmitt trigger with 5 V tolerant input 9. Limiting values Table 5. Limiting values In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V). Symbol Parameter VCC supply voltage IIK input clamping current VI input voltage IOK output clamping current Conditions Max Unit 0.5 +6.5 V - 50 mA 0.5 +6.5 V mA VI < 0 V [1] - 50 Active mode [1][2] 0.5 VCC + 0.5 Power-down mode [1][2] 0.5 +6.5 V - 50 mA VO < 0 V output voltage VO Min IO output current ICC supply current - 100 mA IGND ground current - 100 mA Tstg storage temperature 65 +150 C Ptot total power dissipation - 300 mW [1] VO = 0 V to VCC V Tamb = 40 C to +125 C [3] The input and output voltage ratings may be exceeded if the input and output current ratings are observed. [2] When VCC = 0 V (Power-down mode), the output voltage can be 5.5 V in normal operation. [3] For SC-88 and SC-74 packages: above 87.5 C the value of Ptot derates linearly with 4.0 mW/K. For XSON6 packages: above 118 C the value of Ptot derates linearly with 7.8 mW/K. 10. Recommended operating conditions Table 6. Recommended operating conditions Symbol Parameter VCC supply voltage VI input voltage VO output voltage Tamb ambient temperature Conditions Min Typ Max Unit 1.65 - 5.5 V 0 - 5.5 V 0 - VCC V 40 - +125 C Min Typ Max Unit IO = 100 A; VCC = 1.65 V to 5.5 V - - 0.1 V IO = 4 mA; VCC = 1.65 V - - 0.45 V IO = 8 mA; VCC = 2.3 V - - 0.3 V 11. Static characteristics Table 7. Static characteristics At recommended operating conditions; voltages are referenced to GND (ground = 0 V). Symbol Parameter Tamb = 40 C to +85 VOL Conditions C[1] LOW-level output voltage 74LVC2G17 Product data sheet VI = VT+ or VT IO = 12 mA; VCC = 2.7 V - - 0.4 V IO = 24 mA; VCC = 3.0 V - - 0.55 V IO = 32 mA; VCC = 4.5 V - - 0.55 V All information provided in this document is subject to legal disclaimers. Rev. 9 -- 15 December 2016 (c) Nexperia B.V. 2017. All rights reserved 4 of 19 74LVC2G17 Nexperia Dual non-inverting Schmitt trigger with 5 V tolerant input Table 7. Static characteristics ...continued At recommended operating conditions; voltages are referenced to GND (ground = 0 V). Symbol Parameter Conditions VOH VI = VT+ or VT HIGH-level output voltage IO = 100 A; VCC = 1.65 V to 5.5 V Min Typ Max Unit VCC 0.1 - - V IO = 4 mA; VCC = 1.65 V 1.2 - - V IO = 8 mA; VCC = 2.3 V 1.9 - - V IO = 12 mA; VCC = 2.7 V 2.2 - - V IO = 24 mA; VCC = 3.0 V 2.3 - - V IO = 32 mA; VCC = 4.5 V 3.8 - - V II input leakage current VI = 5.5 V or GND; VCC = 5.5 V - 0.1 1 A IOFF power-off leakage current VI or VO = 5.5 V; VCC = 0 V - 0.1 2 A ICC supply current VI = VCC or GND; IO = 0 A; VCC = 5.5 V - 0.1 4 A ICC additional supply current VI = VCC 0.6 V; IO = 0 A; VCC = 2.3 V to 5.5 V - 5 500 A CI input capacitance - 3.5 - pF IO = 100 A; VCC = 1.65 V to 5.5 V - - 0.1 V IO = 4 mA; VCC = 1.65 V - - 0.70 V Tamb = 40 C to +125 C LOW-level output voltage VOL VOH HIGH-level output voltage VI = VT+ or VT IO = 8 mA; VCC = 2.3 V - - 0.45 V IO = 12 mA; VCC = 2.7 V - - 0.60 V IO = 24 mA; VCC = 3.0 V - - 0.80 V IO = 32 mA; VCC = 4.5 V - - 0.80 V VCC 0.1 - - V IO = 4 mA; VCC = 1.65 V 0.95 - - V IO = 8 mA; VCC = 2.3 V 1.7 - - V VI = VT+ or VT IO = 100 A; VCC = 1.65 V to 5.5 V IO = 12 mA; VCC = 2.7 V 1.9 - - V IO = 24 mA; VCC = 3.0 V 2.0 - - V IO = 32 mA; VCC = 4.5 V 3.4 - - V - 0.1 1 A II input leakage current VI = 5.5 V or GND; VCC = 5.5 V IOFF power-off leakage current VI or VO = 5.5 V; VCC = 0 V - - 2 A ICC supply current VI = VCC or GND; IO = 0 A; VCC = 5.5 V - - 4 A ICC additional supply current VI = VCC 0.6 V; IO = 0 A; VCC = 2.3 V to 5.5 V - - 500 A [1] All typical values are measured at VCC = 3.3 V and Tamb = 25 C. 74LVC2G17 Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 9 -- 15 December 2016 (c) Nexperia B.V. 2017. All rights reserved 5 of 19 74LVC2G17 Nexperia Dual non-inverting Schmitt trigger with 5 V tolerant input 12. Dynamic characteristics Table 8. Dynamic characteristics Voltages are referenced to GND (ground = 0 V); for test circuit see Figure 8. Symbol Parameter 40 C to +85 C Conditions power dissipation capacitance CPD Unit Min Max Min Max VCC = 1.65 V to 1.95 V 1.5 5.6 10.5 1.5 13.1 ns VCC = 2.3 V to 2.7 V 1.0 3.7 6.5 1.0 8.5 ns VCC = 2.7 V 1.0 3.8 6.5 1.0 8.5 ns VCC = 3.0 V to 3.6 V 1.0 3.6 5.7 1.0 7.1 ns VCC = 4.5 V to 5.5 V 1.0 2.7 4.3 1.0 5.4 ns - 16.3 - - - pF propagation delay nA to nY; see Figure 7 tpd 40 C to +125 C Typ[1] per buffer; VCC = 3.3 V; VI = GND to VCC [2] [3] [1] Typical values are measured at Tamb = 25 C and VCC = 1.8 V, 2.5 V, 2.7 V, 3.3 V and 5.0 V respectively. [2] tpd is the same as tPLH and tPHL. [3] CPD is used to determine the dynamic power dissipation (PD in W). PD = CPD VCC2 fi N + (CL VCC2 fo) where: fi = input frequency in MHz; fo = output frequency in MHz; CL = output load capacitance in pF; VCC = supply voltage in V; N = number of inputs switching; (CL VCC2 fo) = sum of outputs. 13. Waveforms 9, Q$LQSXW 90 90 *1' W3/+ W3+/ 92+ 90 Q