Cat No. PAGE Cat No. PAGE Cat No. PAGE
0919 . . . . . . . . . . . . . . .41
0920 . . . . . . . . . . . . . . .41
0936 . . . . . . . . . . . . . . .47
0938 . . . . . . . . . . . . . . .47
992B . . . . . . . . . . . . . .17,73
1041 . . . . . . . . . . . . . . .67
1045 . . . . . . . . . . . . . . .67
1047 . . . . . . . . . . . . . . .76
1048 . . . . . . . . . . . . . . .76,77
1050 . . . . . . . . . . . . . . .76,77
1067 . . . . . . . . . . . . . . .25
1080 . . . . . . . . . . . . . . .61,63,65
1090 . . . . . . . . . . . . . . .78
1091 . . . . . . . . . . . . . . .78
1100 . . . . . . . . . . . . . . .40
1101 . . . . . . . . . . . . . . .40
1250 . . . . . . . . . . . . . . .15
1300 . . . . . . . . . . . . . . .20
13 112 . . . . . . . . . . . . .16,17
13 208 . . . . . . . . . . . . .16
13 211 . . . . . . . . . . . . .17
1350 . . . . . . . . . . . . . . .26
1353 . . . . . . . . . . . . . . .26
1484 . . . . . . . . . . . . . . .26
1487 . . . . . . . . . . . . . . .26
1500 . . . . . . . . . . . . . . .20
1500 Twin units . . . . . .28
1501 . . . . . . . . . . . . . . .20
1502 . . . . . . . . . . . . . . .20
1510 . . . . . . . . . . . . . . .20,28
1511 . . . . . . . . . . . . . . .20
1520 . . . . . . . . . . . . . . .20,28
1521 . . . . . . . . . . . . . . .20
1522 . . . . . . . . . . . . . . .20
1550 . . . . . . . . . . . . . . .26
1551 . . . . . . . . . . . . . . .26
1552 . . . . . . . . . . . . . . .26
1553 . . . . . . . . . . . . . . .26
1560 . . . . . . . . . . . . . . .26
1561 . . . . . . . . . . . . . . .26
1562 . . . . . . . . . . . . . . .26
1570 . . . . . . . . . . . . . . .26
1571 . . . . . . . . . . . . . . .26
1572 . . . . . . . . . . . . . . .26
1700 . . . . . . . . . . . . . . .64
1710 . . . . . . . . . . . . . . .64
1710 Guard . . . . . . . . .63
1720 . . . . . . . . . . . . . . .64
1721 . . . . . . . . . . . . . . .64
1722 . . . . . . . . . . . . . . .64
1750 . . . . . . . . . . . . . . .64
1760 . . . . . . . . . . . . . . .64
1770 . . . . . . . . . . . . . . .64
1911 . . . . . . . . . . . . . . .43
1961 . . . . . . . . . . . . . . .43
22-- . . . . . . . . . . . . . . .30-33
23-- . . . . . . . . . . . . . . .30-33
24-- . . . . . . . . . . . . . . .30-31
25-- . . . . . . . . . . . . . . .30-31
2760 . . . . . . . . . . . . . . .69
2820 . . . . . . . . . . . . . . .70
2821 . . . . . . . . . . . . . . .70
2870 . . . . . . . . . . . . . . .70
290-- Snap action . . . .48
2950 . . . . . . . . . . . . . . .67
2951 . . . . . . . . . . . . . . .68
3005 . . . . . . . . . . . . . . .55
3006 . . . . . . . . . . . . . . .55
3101 . . . . . . . . . . . . . . .56
3102 . . . . . . . . . . . . . . .56
3111 . . . . . . . . . . . . . . .56
3130 . . . . . . . . . . . . . . .74
3141 . . . . . . . . . . . . . . .57
3145 . . . . . . . . . . . . . . .57
3146 . . . . . . . . . . . . . . .57
3147 . . . . . . . . . . . . . . .57
3160 . . . . . . . . . . . . . . .74
3161 . . . . . . . . . . . . . . .74
3221 . . . . . . . . . . . . . . .74
340- Snap action . . . . .50
390- Snap action . . . . .50
3900 Series . . . . . . . . .62
3950 Series . . . . . . . . .62
4102 . . . . . . . . . . . . . . .46
5500 . . . . . . . . . . . . . . .22
5500 Twin units . . . . . .23
0005 . . . . . . . . . . . . . . .61,65
0023 . . . . . . . . . . . . . . .78
0024 . . . . . . . . . . . . . . .78
0033 . . . . . . . . . . . . . . .82
0035 . . . . . . . . . . . . . . .83
0042 . . . . . . . . . . . . . . .23,25,27,29
0046 . . . . . . . . . . . . . . .19,21,23
0055 . . . . . . . . . . . . . . .54
0056 . . . . . . . . . . . . . . .54
0061 . . . . . . . . . . . . . . .75
0062 . . . . . . . . . . . . . . .75
0063 . . . . . . . . . . . . . . .75
0067 Lampholder . . . . .75
0067 Neon . . . . . . . . . .71
0081 . . . . . . . . . . . . . . .70
0092 . . . . . . . . . . . . . . .61,65
0095 . . . . . . . . . . . . . . .75
0145 . . . . . . . . . . . . . . .67
0167 Cover . . . . . . . . .11,13,14,35
0177 . . . . . . . . . . . . . . .71
0180 Neon . . . . . . . . . .71
0180 Cover . . . . . . . . .13,14
0188 Cover . . . . . . . . .16,17
0195 . . . . . . . . . . . . . . .67,72
0196 . . . . . . . . . . . . . . .72
0232 . . . . . . . . . . . . . . .63,65
0233 . . . . . . . . . . . . . . .72
0234 . . . . . . . . . . . . . . .72
0245 . . . . . . . . . . . . . . .67
0273 . . . . . . . . . . . . . . .68,69
0275 . . . . . . . . . . . . . . .69
0276 . . . . . . . . . . . . . . .69
0277 . . . . . . . . . . . . . . .69
0278 . . . . . . . . . . . . . . .68
0279 . . . . . . . . . . . . . . .61,65
0305 . . . . . . . . . . . . . . .53
0306 . . . . . . . . . . . . . . .53
0307 . . . . . . . . . . . . . . .53
0308 . . . . . . . . . . . . . . .53
0320 . . . . . . . . . . . . . . .52
0323 . . . . . . . . . . . . . . .42
0327 . . . . . . . . . . . . . . .47
0331 . . . . . . . . . . . . . . .61,65
0332 . . . . . . . . . . . . . . .82
0333 . . . . . . . . . . . . . . .82
0340 . . . . . . . . . . . . . . .82
0341 . . . . . . . . . . . . . . .82
0345 . . . . . . . . . . . . . . .83
0347 . . . . . . . . . . . . . . .83
0413 . . . . . . . . . . . . . . .78
0430 . . . . . . . . . . . . . . .20,73
0430 Twin units . . . . . .28
0434 . . . . . . . . . . . . . . .21,23
0441 . . . . . . . . . . . . . . .27
0445 . . . . . . . . . . . . . . .78
0480 . . . . . . . . . . . . . . .26,73
0494 . . . . . . . . . . . . . . .23,27,29
0506 . . . . . . . . . . . . . . .61,65
0520 . . . . . . . . . . . . . . .82
0539 . . . . . . . . . . . . . . .61,63,65
0568 . . . . . . . . . . . . . . .68
0569 . . . . . . . . . . . . . . .68
0579 . . . . . . . . . . . . . . .71
0581 . . . . . . . . . . . . . . .72
0582 . . . . . . . . . . . . . . .72
0586 . . . . . . . . . . . . . . .70
0589 . . . . . . . . . . . . . . .70
0600 . . . . . . . . . . . . . . .61
0602 . . . . . . . . . . . . . . .61
0616 . . . . . . . . . . . . . . .27
0707 . . . . . . . . . . . . . . .79
0708 . . . . . . . . . . . . . . .79
0709 . . . . . . . . . . . . . . .79
0710 . . . . . . . . . . . . . . .79
0711 . . . . . . . . . . . . . . .79
0717 . . . . . . . . . . . . . . .80
0721 . . . . . . . . . . . . . . .81
0722 . . . . . . . . . . . . . . .81
0723 . . . . . . . . . . . . . . .81
0873 . . . . . . . . . . . . . . .83
0910 . . . . . . . . . . . . . . .42
0911 . . . . . . . . . . . . . . .42,45
0911 Vandal . . . . . . . . .42,45
0916 . . . . . . . . . . . . . . .41
0917 . . . . . . . . . . . . . . .41
0918 . . . . . . . . . . . . . . .41
5503 . . . . . . . . . . . . . . .22
5508 . . . . . . . . . . . . . . .22
6000 . . . . . . . . . . . . . . .18
6000 Twin units . . . . . .25
6001 . . . . . . . . . . . . . . .18
6002 . . . . . . . . . . . . . . .18
6003 . . . . . . . . . . . . . . .18
6008 . . . . . . . . . . . . . . .18
6009 . . . . . . . . . . . . . . .18
6010 . . . . . . . . . . . . . . .18
6011 . . . . . . . . . . . . . . .18
6030 . . . . . . . . . . . . . . .18,73
6050 . . . . . . . . . . . . . . .24
6051 . . . . . . . . . . . . . . .24
6052 . . . . . . . . . . . . . . .24
6053 . . . . . . . . . . . . . . .24
6054 . . . . . . . . . . . . . . .24
6055 . . . . . . . . . . . . . . .24
6056 . . . . . . . . . . . . . . .24
6057 . . . . . . . . . . . . . . .24
6058 . . . . . . . . . . . . . . .24
6059 . . . . . . . . . . . . . . .24
6060 . . . . . . . . . . . . . . .24
6061 . . . . . . . . . . . . . . .24
6062 . . . . . . . . . . . . . . .24
6066 . . . . . . . . . . . . . . .24
6067 . . . . . . . . . . . . . . .24
6068 . . . . . . . . . . . . . . .24
6090 . . . . . . . . . . . . . . .24
6091 . . . . . . . . . . . . . . .24
6092 . . . . . . . . . . . . . . .24
7000 . . . . . . . . . . . . . . .38
7001 . . . . . . . . . . . . . . .38
7003 . . . . . . . . . . . . . . .38
7004 . . . . . . . . . . . . . . .38
7030 . . . . . . . . . . . . . . .38,73
7050 . . . . . . . . . . . . . . .38
7051 . . . . . . . . . . . . . . .38
7053 . . . . . . . . . . . . . . .38
7054 . . . . . . . . . . . . . . .38
8200 . . . . . . . . . . . . . . .36
8201 . . . . . . . . . . . . . . .36
8250 . . . . . . . . . . . . . . .36
8251 . . . . . . . . . . . . . . .36
8300 . . . . . . . . . . . . . . .34
8300 Vandal . . . . . . . . .44
8301 . . . . . . . . . . . . . . .34
8301 Vandal . . . . . . . . .44
8303 . . . . . . . . . . . . . . .34
8304 . . . . . . . . . . . . . . .34
8350 . . . . . . . . . . . . . . .34
8350 Vandal . . . . . . . . .44
8351 . . . . . . . . . . . . . . .34
8351 Vandal . . . . . . . . .44
8353 . . . . . . . . . . . . . . .34
8354 . . . . . . . . . . . . . . .34
8500 . . . . . . . . . . . . . . .10
8500 Push . . . . . . . . . .35
8503 . . . . . . . . . . . . . . .10
8550 . . . . . . . . . . . . . . .10
8550 Semi Rotary . . . . .11
8553 . . . . . . . . . . . . . . .10
8580 . . . . . . . . . . . . . . .10,73
8600 . . . . . . . . . . . . . . .12
8601 . . . . . . . . . . . . . . .12
8602 . . . . . . . . . . . . . . .12
8610 . . . . . . . . . . . . . . .12
8611 . . . . . . . . . . . . . . .12
8620 . . . . . . . . . . . . . . .14
8630 . . . . . . . . . . . . . . .12,73
8634 . . . . . . . . . . . . . . .13
8650 . . . . . . . . . . . . . . .12
8651 . . . . . . . . . . . . . . .12
8652 . . . . . . . . . . . . . . .12
8653 . . . . . . . . . . . . . . .12
8660 . . . . . . . . . . . . . . .12
8661 . . . . . . . . . . . . . . .12
8670 . . . . . . . . . . . . . . .14
8800 . . . . . . . . . . . . . . .8
8800 Twin units . . . . . .8
8801 . . . . . . . . . . . . . . .8
8802 . . . . . . . . . . . . . . .8
9000 . . . . . . . . . . . . . . .60
9100 . . . . . . . . . . . . . . .58
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
Index
84
Solutions for appliance & electronic applications
arcolectric
indicator lamps
appliance switches
fuseholders
IEC sockets
arcolectric
Arcolectric Switches plc,
Central Avenue,
West Molesey, Surrey
England KT8 2RF
tel: +44 (0)20 8979 3232
fax: +44 (0)20 8979 2565
info@arcoswitch.co.uk
www.arcolectric.co.uk
Catalogue 168
April
2003
this catalogue is available on CD
and on www.arcolectric.co.uk
for appliance & electronic applications
Solutions
Profile
North American Customers
We have a 20,000sqft production
& distribution facility in Los Angeles:
Arcolectric Corporation,
9001 Canoga Avenue, Canoga Park,
California 91304, USA.
Tel +1 818 700 1933
Fax +1 818 700 9541
e-mail info@arcolectric.com
Web www.arcolectric.com
President Carrie Bonica
Arcolectric Switches plc
Head Office, Sales and R&D
61 Central Avenue, West Molesey,
Surrey, England KT8 2RF
VAT Registration No. GB 211 3314 30
Tel +44 (0)20 8979 3232
Fax +44 (0)20 8979 2565
e-mail info@arcoswitch.co.uk
Web www.arcolectric.co.uk
Directors
R.A. Collier Chairman
H.J.A. Cowley Managing Director
J. Harris Technical Director
J. Collier Director
M.A. Collier Director
I. Ranken Collins Non-executive Director
Company Secretary D. Birdwood-Hedger
Export Sales H.J.A. Cowley
L.A. Hamon
UK Sales C. Macdonald
Arcolectric worldwide
Arcolectric Switches plc, established in 1932, specialise in
the manufacture of appliance switches, indicator lights and
fuseholders for every kind of product from computers to
coffee machines and lighting to laser printers.
We have two fully integrated factories totalling 90,000 sq.ft.
in Surrey, England, where we manufacture mouldings, springs,
pressings and turnings. The majority of our product is
assembled automatically.
Arcolectric also have purpose built factories in Shenzhen, China
(42,000sq.ft) and Tunis, North Africa (30,000 Sq.ft.).
The Group has recently acquired Otehall Switches Ltd., a
specialist manufacturer of high quality snap-action switches.
Arcolectric Switches plc and Otehall Switches Ltd are wholly
owned subsidiaries of Arcolectric Holdings plc, a Public Company
quoted on the Alternative Investment Market (AIM) in London.
contents
rocker
switches
8 - 29
technical
data
4, 6, 66
slide
switches
30 - 33
rotary
switches
58 - 60
push
switches
34 - 47
vandal resist
switches
snap-action
& safety
switches
42 - 45
48 - 52
refrigerator
switches
53 - 57
lever
switches
61 - 65
indicators
66 - 78
IEC
sockets
79 - 81
fuseholders
82 - 83
Approvals
The majority of Arcolectric products are covered by
international approvals. These will assist you in obtaining
worldwide approval of your own products.
Europe - The ENEC mark replaces national approval marks
for switches complying with product standard EN61058-1.
America - Switch approvals to UL1054.
Canada - Switch approvals to CSA C22.2 No.55-M1986.
Our North African and China factories are also approved by
these authorities.
Quality Assurance Approval
We are a BSI Registered Firm to
BS EN ISO 9002: 1994. Certificate No: FM 14821.
Not all products are produced on site, such items are therefore not manufactured under this approval.
Appliances bearing the mark are able to circulate freely
in Europe. Products in this catalogue, when fitted correctly,
comply with the CE requirement insofar as it relates to them.
Product from stock
For stock product availability please visit our website, call
our sales office or contact your nearest agent or distributor,
listed on the back of this catalogue.
Bankers
HSBC Bank plc,
56 High Street, Esher, Surrey, KT10 9RD.
Sterling Account No. 21148257 Sort Code: 40-20-26
HSBC Bank plc,
P.O. Box 181, 27-32 Poultry, London, EC2P 2BX.
U.S. Dollar Account No. 37038042 Sort Code: 40-05-15
Euro Account No. 39023138 Sort Code: 40-05-15
The Hong Kong and Shanghai Banking Corporation Limited,
1 Queen's Road, Central, Hong Kong.
U.S. Dollar Account No. 600-833255
Hong Kong Dollar Account No. 600-833255-001
NATIONAL
ACCREDITATION
OF CERTIFICATION
BODIES
GO
GO
for appliance & electronic applications
Solutions
6 Million Products
Every month we assemble over six million switches, indicator
lights, fuseholders and IEC sockets.
5 Manufacturing Centres
Almost all component parts used in our products - mouldings,
pressings, springs and turned parts, are manufactured in
our own production centres, then assembled and tested
fully automatically.
23 Automatic Assembly Machines
The great majority of our rocker, slide, push button and lever
switches are assembled automatically.
52 Injection Moulding Machines
Working at pressures up to 80 tons, our mould shop delivers
over 250 million components each year.
60,000 Miniature Springs
Some only a millimetre or so in diameter, are wound each
hour. Every one will be measured and tested.
15 Power Presses
We manufacture over 200,000 contacts and terminals
every hour.
Production
CONTS
Automated Testing
Each assembly machine tests the electrical and mechanical
function of every completed product.
8,000,000 turned parts
On site manufacture of our component parts ensures full
control of our production.
Tooling - In-house
A fully equipped toolroom manufactures and maintains the
jigs, press and mould tools we use each day.
Flexibility of response
Twenty-four hour running allows a positive response to
customer requests and ensures a competitively priced
finished product.
Research & Development
Our designers will work with you to achieve practical solutions
which satisfy your particular design criteria.
Arcolectric is the largest manufacturer
of appliance switches in the UK.
effective
design
development
sampling
costing
production
distribution
support
CONTS
Technical Information - Switches and Fuseholders
Most major technical information is shown on each specific
product page,other details are grouped here for easy reference.
Details shown here apply to most switches and fuseholders.
Snap-action switches (pages 42, 45 and 48-51), indicators
(pages 66-78) and connectors (pages 79-81) have product
specific information within the section.
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
4
MATERIALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .MOST PRODUCTS . . . . . . . . . EXCEPTIONS
Body and actuator (opaque) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Nylon 6.6. . . . . . . . . . . . . . . 8300V, 1900V, 0916V & 0911V bezels & actuators
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . are stainless steel
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . 0600 and 3900 actuators are plated brass
Actuator (transparent) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Polycarbonate . . . . . . . . . . .
Current carrying parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Copper Alloy. . . . . . . . . . . . .
Contact points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Silver Alloy. . . . . . . . . . . . . . N/A for 0055/56, 0600/2, 0916-0920, 0017,
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . 2000 & 3005/3006. Gold plated for 1100.
PROPERTIES
Electrical
Class II compliant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Confirmed . . . . . . . . . . . . . . IEC Sockets
Electrical life (Operations) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>10k, many >50k . . . . . . . . See relevant page for details
Contact resistance (switches) new condition . . . . . . . . . . . . . . . . . . . . . .<100m(at 12Vdc,1A) . . . . For 1100 & 2000 call factory
Contact resistance (fuseholders) new condition . . . . . . . . . . . . . . . . . . . .5m(average)
Insulation resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>20m
Dielectric strength:
across open contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>1kV
between poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>3kV
between live parts and accessible metal . . . . . . . . . . . . . . . . . . . . . .>4kV
Comparative Tracking Index (CTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>250
Temperature rise (terminals) at end of rated life . . . . . . . . . . . . . . . . . . . .max 30˚K (UL 1054), max 55˚K (EN 61058-1)
PROPERTIES
Physical
Humidity resistance at 91-95% relative humidity
(to subsequently comply with requirements of the
Dielectric strength test) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48hrs
Impact resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>0.5Nm
Storage temp. (1 year period) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<125˚C. . . . . . . . . . . . . . . . . Some discolouration of terminals may occur
Flame retardancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .UL94V2
Solderability to BS 2011 pt.2.1T - (with an iron) . . . . . . . . . . . . . . . . . . . .6 secs at 350°C
Angular movement ± overall (where applicable) . . . . . . . . . . . . . . . . .38°. . . . . . . . . . . . . . . . . . . . 1250, 6000, 8500, 8550, 8600, 8650, 8800 - 26°
Force to operate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.0N - 20.0N . . . . . . . . . . . . Call factory for specific values
Fixing nut torque (where applicable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0Nm (8.91 lb/in) nom.. . . . Call factory for specific values
CONTS
ALL SWITCHES
Heat and Fire resistance Category D.
Ingress Protection without cover is IP40.
Higher ratings where available will be shown on the relevant
catalogue page.
ALL PRODUCTS
Solder terminals should not be fitted with “Push on”,“QD”or “Fast on”
type cable connectors.
Panel holes must be punched in the direction of insertion.
Items marked on the following pages are assembled automatically.
This ensures the highest attainable quality at a competitive price.
All products should be applied, installed and maintained by the
customer using competent persons in accordance with good electrical
practice. Products should be tested by the customer in the application
to ensure suitability. Special care should be taken not to expose
switches to water,dust,corrosive chemicals,silicone ,excessive solder
flux, cyanoacrylate adhesives, severe impact, extremes of temperature,
electrical supply voltage or load current in excess of the specified limits.
Transparent lenses on indicator lights and lit switches are moulded in
polycarbonate, a material which is attacked by organic chemicals and
animal or vegetable fats.
Please contact the factory for advice on these products.
For performance in accord with the stated ratings, switch actuators
should be fully depressed and fully released during operation.
GENERAL INFORMATION
Product . . . . . . . . . gms
1048 . . . . . . . . . . . 2.8
1091FH . . . . . . . . . 12.6
1091FL . . . . . . . . . 52.8
1100 . . . . . . . . . . . 2.0
1250SP . . . . . . . . . 5.9
1250DP . . . . . . . . . 7.0
1300 . . . . . . . . . . . 5.7
1350 . . . . . . . . . . . 11.2
1500 . . . . . . . . . . . 5.7
1520 . . . . . . . . . . . 6.6
1550 . . . . . . . . . . . 11.2
1553 . . . . . . . . . . . 11.8
Product . . . . . . . . . gms
0055, 0056 . . . . . . 5.7/6.8
0305 . . . . . . . . . . . 32.9
0333 . . . . . . . . . . . 4.5
0345 . . . . . . . . . . . 8.9
0340 sw only . . . . . 7.12
0340K/P.. . . . . . . . 25.0
0430 . . . . . . . . . . . 5.5
0589 . . . . . . . . . . . 3.5
0711-1S. . . . . . . . . 16.6
0712-S. . . . . . . . . . 27.8
0717-1S. . . . . . . . . 22.4
0900S/L. . . . . . . . . 2.6/2.9
WEIGHTS OF OUR MOST FREQUENTLY SUPPLIED PRODUCTS,not including packaging.
Product . . . . . . . . . gms
1570 . . . . . . . . . . . 12.7
1584-1589. . . . . . . 11.1
1700H . . . . . . . . . . 8.4
1750H . . . . . . . . . . 13.2
1750O . . . . . . . . . . 25.6
2000 2pos C SP. . . 3.8
2000 2pos C DP. . . 4.5
2000 5pos A SP . . . 6.3
2000 5pos A DP. . . 7.3
T2225B . . . . . . . . . 5.0
2950 . . . . . . . . . . . 5.3
3111 . . . . . . . . . . . 11.8
Product . . . . . . . . . gms
5500 . . . . . . . . . . . 7.1
5503 . . . . . . . . . . . 7.8
5567 . . . . . . . . . . . 14.3
6050 . . . . . . . . . . . 13.58
6053 . . . . . . . . . . . 14.15
7000 . . . . . . . . . . . 10.4
7050 . . . . . . . . . . . 12.3
7053 . . . . . . . . . . . 12.9
8250 . . . . . . . . . . . 4.9
8300 . . . . . . . . . . . 4.0
8350 . . . . . . . . . . . 5.0
8350RP . . . . . . . . . 34.0
Product . . . . . . . . . gms
8353 . . . . . . . . . . . 5.9
8500.. . . . . . . . . . . 3.8
8550 . . . . . . . . . . . 4.8
8553 . . . . . . . . . . . 5.2
8600 . . . . . . . . . . . 3.5
8620 . . . . . . . . . . . 4.3
8650 . . . . . . . . . . . 6.3
8670 . . . . . . . . . . . 8.5
8800 . . . . . . . . . . . 2.9
9100 . . . . . . . . . . . 20.0
5
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
CONTS
Splashproof & Dust Resistant options for Switches
Mounting method and product orientation, air movement, pressure
differential across the product, intensity of impinging liquid flow and
application voltage.
Splashproofing does not imply total sealing, or resistance to
corrosive atmospheres or substances.
Suitability
A large number of Arcolectric products have optional or designed-in
resistance to moisture or dust.
For detailed IP ratings call the factory.
The suitability of these products for specific applications is subject
to numerous factors including:
Page 10 Pages 12 & 14 Pages 12 & 14 Page 16 Page 16
Page 18 Page 20 Page 22 Page 24 Page 26
Order code for
splash/dust proofing
options
is shown under the
illustration
Order code for
splash/dust proofing
options
is shown under the
illustration
feather-edge seal
collar
How they work
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
6
6000 1500 and 1300 5503 6050 1550 and 1350
has integral available with W or B can be fitted with has integral can be fitted with
water-thru feature and Splashproof rockers or water-thru feature and
GGGGG
Snap-on cover option Snap-on cover Snap-on cover Snap-on cover option Snap-on cover
G
Snap-on splashproof/
dustproof cover & bezel
for rocker switches
L167, L180, L188
Push-on splashproof/
dustproof covers
for rocker/push switches
8500 Twin 8600 & 8620 8650 & 8670 R13 Single pole R13 Double pole
can be fitted with can be fitted with can be fitted with can be fitted with can be fitted with
L167 L167 L180 L188 L188
Push-on cover Push-on cover Push-on cover Push-on cover Push-on cover
1500 W and 1500 B splashproof rockers
have internal feather edge seals and a close fitting
collar to protect current carrying parts from moisture
Option Bhas Hytrel moulded collar/seals for enhanced protection
CONTS
The right system
The fitting of external covers or panel sealing washers will normally
alter standard panel acceptance dimensions.
The fitting of external covers is not recommended for momentary
(spring return) rocker or lever switches.
In all instances applications should be discussed with the factory.
We will advise you on the best system for your application.
For full product details, dimensions and ratings refer to the
catalogue page shown in the photograph (not to scale).
Page 55 Page 56/57 Page 62 Page 64 Page 61
Page 34 Page 41 Page 43 Page 44 Page 45
Order code for
splash/dust proofing
options
is shown under the
illustration
Order code for
splash/dust proofing
options
is shown under the
illustration
O-ring
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
7
3005 3100 and 3141 3900 and 3950 1700 and 1750 0600
splashproof design splashproof design have integral O-ring seal can be fitted with can be fitted with
and can be fitted with
M539 or M1080 M331, M539, M1080 M331, M539, M1080
neck seal or cover covers or neck seals covers or neck seals
Water-thru
Integral
splashproof
system (pat app.)
Covers & Neck seals
(with nut fixing)
for lever switches
O-ring
Integral seal
for 3900 series
metal lever switches
8300 0916V 1900 8300V 0911V
can be fitted with has integral seal has integral seal has integral seal has integral seal
L167
Push-on cover
CONTS
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, ETC
H8800 V A - - -
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
8
8800/8800
V
Curved
Switches are ON when pressed over terminal 1
8800 Thinline Rocker Switches10A 250Vac
ROCKERFUNCTION
ON - OFF
Single pole
TERMINAL
8800
8801 ON - OFF (momentary ON)
Single pole
ON - OFF
Twin (Single pole)
H
4.8 x 0.8
T
3.5 x 0.8
Solder
10(6)A 250Vac T100
6(2)A 250Vac T100 5E4 (50,000 Operations)
Inrush 50A to EN60065:1998
UL CSA 15A 250Vac (Twin unit is 10A 250Vac)
UL CSA 125Vac 1/2hp
UL 100˚C,file E45221, CSA file LR10990
10A 28Vdc
3mm contact gap
Technical data on pages 4 & 5
In house test
9.7
2.6 8.8
1.5
1
1a
Switches are ON when pressed over terminals 1 or 3
3
4
1
2
Call factory for ratings
& dimensions
8802 ON - OFF (momentary OFF)
Single pole
Call factory for ratings
& dimensions
Factored
product
Factored
product
CONTS
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
9
8800V/8800V A (H terminals shown)
Finish
Matt finish only
Colour
Call factory for custom colours.
A full range is available for large orders
Legend printing
Select from the examples or call the
factory for custom legends
Examples of printing
CL132 CL133
H8800VA ---
T8800VA ---
H8800V/H8800VA
T8800V/T8800VA
H8800VA ---
T8800VA ---
H8800V/H8800VA
T8800V/T8800VA
6.3
5.0
9.7
2.0
9.0
14.5
5.0
9.7
2.0
9.0
14.5
BODY
A Single pole
A Single pole - Twin
Panel thickness Dim X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
Dimensions (mm)
8800VA (H terminals shown)
Panel cut-outs Flange
OPTIONS
Cut-outs must be punched in the direction of insertion
21.0
9.5
6.2
6.3
6.8
6.9
17.4
17.5
X
*
*
*Optional profile
for orientation
*Optional profile
for orientation
21.0
15.5
9.9
10.0
X
13.4/
13.5
17.4
17.5
*
*
Actual Size
CONTS
H Slotted for custom adaptors
R Semi-rotary
D Paddle lever (8500 only)
(not lit)
V Curved (not lit)
V Curved (lit)
X Two colour (not lit)
A Softline lens
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
10
TERMINAL FUNCTION ROCKER BODY PRINT,COLOUR,VOLTAGE ETC
H8550 V B
---
On Off Switches are ON when pressed over terminal 1
8550
8503
8500 Rocker Switches - Miniature 10A 250Vac Single & Double Pole
ROCKERFUNCTION
Approvals &
ratings vary
with function
ON - OFF
Single pole
(Uses terminals 1a & 2a)
ON - OFF - Lit
Double pole
Indicator
ON - OFF - Lit
Single pole
ON - OFF
Double pole
TERMINAL
8553
8500
8580
Available with
H terminals only
H
4.8 x 0.8
K
2.8 x 0.8
L
2.8 x 0.8
Right angle version of K terminal
available on 8500 only
R
4.8 x 0.8
T
Solder
8.5
4.5
1.5
3.1
Slots for
snap-in buttons
10(6)A 250Vac T125 (non lit types)
6(4)A 250Vac T125 5E4 (50,000 Operations) (non lit types)
10(6)A 250Vac T100 (lit types)
UL CSA 15A Non Ind 250Vac, 14A Ind 250Vac, 10A 277Vac
UL CSA 250Vac 1/2hp, 125Vac 1/4hp
UL 105˚C,file E45221, CSA file LR10990
Inrush 85A to EN61058-1 & 10A 28Vdc
3mm contact gap
Technical data on pages 4 & 5 (switches), 66 (indicators)
1a
3b
2a
4b
8.5
2.6
1.5
3.2
2.6
8.5
3.5
R1.0
R0.8
In house test
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
11
Finish
Matt finish only
Colour
Call factory for custom colours
A full range is available for large orders
Legend printing
Select from the examples or call the
factory for custom legends
Lamp voltage
Call factory for details of other
available voltages
Protective cover L167
(designed to IP65)
Snaps on to bodies with V or X style
rockers and A style lens but reduces
panel thickness by 0.8mm
Examples of printing
CL076 CL080
H8500VB ---
T8500VB --- H8550VB ---
T8550VB ---
H8553VB ---
T8553VB ---
H8550XB ---
T8550XB ---
H8580AB ---
H8550RB Semi-rotary
A splash proofing option
BODY
B
Standard body with terminal barrier
BC
Body without terminal barrier
Dimensions for snap-in fixing
Panel
thickness Dim X
0.75-1.25 19.1/19.2
1.25-2.00 19.3/19.4
2.00-3.00 19.7/19.8
DIMENSIONS (mm)
Panel cut-outs Flange
5.1
22.5
9.0
2.0
9.0
14.0
6.0
9.5
OPTIONS
21.0
15.0
X
12.9
21.0
15.0
X
12.9
“B” body with barrier for
H,T and K terminals
5.1
16.0
4.5
2.0
9.0
14.0
“BC” body w/o barrier primarily
for L or R terminals
(can be used for all terminals)
Terminal spacing between 1a & 3b - 6.0, between 2a & 4b - 9.5
Cut-outs must be punched in the direction of insertion
12
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
TERMINAL FUNCTION ROCKER BODY PRINT,COLOUR,VOLTAGE ETC
H8653 V B
---
V Curved
V Curved (lit)
D Paddle lever
(Single pole non-lit only)
F Flat
Indicator only (Single pole)
8600 Rocker Switches - Miniature 10A 250Vac Single & Double Pole
ROCKERFUNCTION
Approvals &
ratings vary
with function
On Off Switches
are ON when pressed
over terminal 3
ON - OFF 8600
10(4)A
16A 250V, 10A 277V
8650
10(4)A
10A 277V
ON - OFF
(momentary ON)
8601
6(1)A
16A 250V, 6A 277V
8651
6(1)A
6A 277V
ON - OFF
(momentary OFF)
8602
10A
16A 250V, 10A 277V
8652
10(4)A
6A 277V
ON - OFF
Lit
N/A 8653
10(4)A
6A 277V
ON - ON 8610
6(1)A
10A 277V
8660
6(1)A
10A 277V, 1/2HP 277V
1/2HP 250V, 1/4HP 277V
ON - OFF
(momentary 1 side)
8611
6A 277V
8661
6A 277V
ON - OFF - ON 8620 µ
See page 14 8670 µ
See page 14
Indicator 8630
TERMINAL
H
4.8 x 0.8
T
3.5 x 0.8
Solder
X
PCB*
0.8 Sq
Y
Right angle PCB
1.3 x 0.8
Contact the factory for details
*Switches with “X” terminals are
supplied without terminal barriers
7.4
10(4)A 250Vac T90 (unless noted below)
UL CSA See ratings below
UL 65˚C,file E45221, CSA file LR10990
Inrush 25A to EN61058-1 & 10A 28Vdc
3mm contact gap except where marked µ
Technical data on pages 4 & 5 (switches), 66 (indicators)
6.4
O/ 2.2
5.3
3.7
6.0
2
13
2
13
5
46
In house test
13
Finish
Matt finish only
Colour
Call factory for custom colours
A full range is available for large orders
Legend printing
Select from the examples or call the
factory for custom legends
Lamp voltage
Call factory for details of other
available voltages
Blanking plate A8634FB
Dummy unit to fill unused panel holes
Single pole size only
Protective covers
L167 for SP
L180 for DP
(designed to IP65)
Snap on to bodies with V rocker or F lens
but reduce panel thickness by 0.8mm.
Not for use with momentary types
Single Pole options
Most switches shown can have single
pole switching in double pole bodies
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
Examples of printing
CL142 CL059 CL058
CL076 CL080 CL141
H8600VB ---
T8600VB --- H8600VB ---
T8600VB ---
H8660VB ---
T8660VB --- T8653VB ---
H8630FB ---
T8630FB ---
H8653VB ---H8650VB ---
T8650VB ---
BODY
BSingle pole
Single Pole dimensions for snap-in fixing
Panel thickness Dimension X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
B (Double Pole) with terminal barrier
BC (Double Pole) w/o terminal barrier
Double Pole dimensions for snap-in fixing
Panel thickness Dimension X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
DIMENSIONS(mm)
Single pole Double pole
Panel cut-outs Flange
5.8
12.5
2.0 7.4
7.0
7.0
OPTIONS
21.0
15.0
X
12.9
21.0
24.0
X
21.9
Terminals shown
are “H” 4.8 push on type
For 8620 and 8670 see page 14
5.8
19.8
to barrier
2.0 12.5
7.0
7.0
Terminal spacing
10.2 between pole centres
Cut-outs must be punched in the direction of insertion
14
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, ETC
H8620 V B - - -
CL141 CL142
Examples of printing
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
H8620VB - - - H8670VB - - -
T8620VB - - - T8670VB - - -
Finish
Matt finish only
Colour
Call factory
for custom colours.
A full range is available
for large orders
Legend printing
Select from the
examples or call factory
for custom legends
Protective covers IP65
L167 for SP
L180 for DP
(designed to IP65)
Snaps on to body but
reduces panel thickness
by 0.8mm
8620 & 8670 Rocker Switches - 3 Positions 10A 250Vac
OPTIONSFUNCTION
V Curved B Single pole
Panel thickness Dim X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
BDouble pole
Panel thickness Dim X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
8620
ON - OFF - ON
Single pole
ROCKER BODYTERMINAL
H
4.8 x 0.8
T
Solder
X
PCB 0.8sq
Switches with X terminals are
supplied without terminal barriers
8.5
10(4)A 250Vac T90
UL CSA 15A 277Vac (Single pole)
UL CSA 250Vac 1/2hp (Single pole)
UL CSA 125Vac 1/4hp (Single pole)
UL CSA 10A 277Vac (Double pole)
UL CSA 125/250Vac 1/2hp (Double pole)
UL CSA 277Vac 1/2hp (Single & Double pole)
UL 90˚C,file E45221, CSA file LR10990
10A 28Vdc
µ contact gap
Technical data on pages 4 & 5
6.4
O/ 2.15
8.0
4.0
Dimensions (mm)
8620VB (H terminals shown) 8670VB (H terminals shown) 8670VB (X terminals shown)
8670
ON - OFF - ON
Double pole
213
5b
4b 6b
2a1a 3a
15.0
2.0
8.5
7.0
Ctrs
14.0
X
12.9
21.0
15.0
21.0
24.0
X
21.9
15.0
2.0
8.9
7.0
Ctrs
14.0
10.2
Ctrs
15.0
2.0
8.0
7.0
Ctrs
14.0
10.2
Ctrs
Cut-outs must be punched in the direction of insertion
In house test
Finish
Matt finish only
Colour
Call factory
for custom colours.
A full range is available
for large orders
Legend printing
Select from the
examples or call factory
for custom legends
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, ETC
C1250 A P - - -
CL085 CL086
C1250AP - - - C1250AN - - -
Examples of printing
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
15
1250 Rocker Switches10A 250Vac
OPTIONSFUNCTION
On when pressed over terminal 1
A Curved
Shown in N body
Shown in P body
N
Panel thickness Dim X
0.75-1.24 26.1/26.2
1.25-1.99 26.3/26.4
2.00-3.00 26.7/26.8
P
Panel thickness
0.75-3.00
1250
ON - OFF
Double pole
Poles are 9.0mm
between centres.
ROCKER BODYTERMINAL
C
6.3 x 0.8
X
PCB 0.8sq
(N body only)
9.0
10(6)A 250Vac T100
6A 400Vac T100
1A 30Vdc
UL CSA 10A 250Vac
UL CSA 16A 250Vac Resistive
UL CSA 125Vac 1/2hp
UL CSA 1A 30Vdc
UL 100˚C,file E45221, CSA file LR10990
Inrush 75A to EN61058-1 & 10A 28Vdc
3mm contact gap
Technical data on pages 4 & 5
9.0
5.2
Dimensions (mm)
1250AN (C terminals shown) 1250AN (X terminals shown) 1250AP (C terminals shown)
2a
1a 2
1
1250SP
ON - OFF
Single pole
1a 1
2
1
2a
1a
On when pressed over terminal 1
11a
11.0 21.0
Sub-panelFacia
10.6
9.8
4.0
6.0 26.0
Panel
10.6
9.8
4.0
11.0 17.0
Sub-panelFacia
10.6
4.0 3.2
29.5
15.0
29.5
13.0
13.1
nom
23.8
nom
R3.5
12.4/
12.5
X
12.4/
12.5
27.2/
27.3
Panel cut-out Flange
Panel cut-out Flange
Sub-panel Facia
Cut-outs must be punched in the direction of insertion
In house test
R13 Round Rocker Switches6A 250Vac
PRODUCT
DETAILS DIMENSIONS (mm)
SP 6A 250Vac T85,
DP 10(4)A 250Vac T85
UL CSA SP 10A 125Vac & 6A 250Vac (For 16A call the factory)
UL CSA DP 8A 125/250Vac
UL 85˚C, file E67774(S) CSA file LR45128
7.1 7.1 8.1
14.5
5.5
123
Ø23.0
2.0
0.9
Ø20.2
2.2
Ø17.0
4.8x0.8
12
12
12
123
123
123
123
123
Snap fixing into panel thickness up to 3.0
* R13 208F has 12.5mm deep body
*
5.0
8.5
15.8
5.5
12
Ø23.5
2.0
7.8
Ø17.0
only
Factored
product
Double pole
Panel cut-out
Single pole
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
SP ON - OFF µ
Cat no.
R13 112A AAA
SP ON - OFF µ
Cat no.
R13 112A AAB
SP ON - OFF µ
Lit 230V
Cat no.
R13 112B NAA
SP ON - OFF µ
Lit 230V
Cat no.
R13 112B NAB
DP ON - OFF
Cat no.
R13 244A AAA
SP ON - OFF µ
Lit 230V
Cat no.
R13 112B NAC
SP ON - ON µ
Cat no.
R13 112C AAA
SP ON - OFF - ON µ
Cat no.
R13 112D AAA
SP ON - OFF µ
(Momentary On)
Cat no.
R13 208F AAA*
DP ON - OFF
Lit 230V
Cat no.
R13 244B NAA
Single pole has µ contact gap
Technical data on pages 4 & 5
Standard products
Are supplied with the body and rocker colour, print & lamp voltage shown in
the product illustration and description
16
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR,VOLTAGE ETC
R13 112A AAA
R13 Round Rocker Switches6A 250Vac
PRODUCT
DETAILS PANEL CUT-OUT (mm)
6A 250Vac T85
UL CSA 10A 125Vac & 6A 250Vac (For 16A call the factory)
UL 85˚C, file E67774(S) CSA file LR45128
0.9
Ø20.2
2.2
12
123
12 3+
3
-
13
Snap fixing into panel thickness up to 3.0
* Dependent on panel thickness 0.75 - 3.0
12
123
Sub-panel Mounting
approvals - contact the factory
19.2/
19.8*
13.0
For R13 211A
R13 211C
For R13 112A2
R13 112B2
R13 112LP
R9 92B
Ø17.0
4.8x0.8
7.1 8.1
14.5
321
Ø23.0
2.0 5.5
Ø17.0
4.8x0.8
7.1 7.1 8.1
14.5
5.5
123
Ø23.0
2.0
Ø15.0
4.8x0.8
7.1 7.1 8.1
14.5
10.0
123
Ø23.0
2.0
Ø17.0
4.8x0.8
14.2 8.1
14.5
4.0
13
Ø23.0
2.0
4.8x0.8
7.1
11.8
12
Ø22.3
12.0
2.0
7.1
only
Factored
product
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
SP ON - OFF µ
Bright colour ON signal
Cat no.
R13 112A2 - -
SP ON - OFF µ
Lit Window
Cat no.
R13 112B2 - -
SP ON - OFF µ
Paddle tip has red LED
Cat no.
R13 112LP - -
Indicator light
Cat no.
R9 92B - - -
SP ON - OFF µ
R13 211A - - -
SP ON - ON µ
R13 211C - - -
Protective cover L188
Snaps on to bodies (not R13 211 or R13 112LP)
but reduces panel thickness by 0.6mm
Single pole has µ contact gap
Technical data on pages 4 & 5
Special products
Are made to order and can be supplied with a range of body and rocker/lens colours,
print & lamp voltage
Call the factory for availability to your special requirements
17
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR,VOLTAGE ETC
R13 112A2 - -
18
TERMINAL FUNCTION ROCKER BODY PRINT,COLOUR,VOLTAGE ETC
C6003 A L
---
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
C
6.3 x 0.8
H
4.8 x 0.8
S
Screw & Clamp
N/A for assemblies
with 3 terminals
European 16(4)A 250Vac T125, 10A 400Vac T125
UL CSA 20A+277Vac, 250Vac 11/2hp, 125Vac 1hp
UL 100˚C,file E45221, CSA file LR10990
Inrush 150A* to EN61058-1 (On - Off only)
20A 28Vdc
+*applies to non-momentary types
6000 Switches feature “Arcshield” to hide visible switching arc
3mm contact gap with Positive Break switching
Call factory for IP details
Technical data on pages 4 & 5 (switches), 66 (indicators)
Patent app.
A Softline
Matt
A Softline
Matt
P Lit window
Matt
A Lens
Matt (6030 indicator only)
6000 SP Splashproof Rocker Switches16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
On Off Switches - ON when pressed over terminal 3
TERMINAL
6000 ON - OFF
9.7
9.7
9.7
12 3
6001 ON - OFF (momentary ON)
6002 ON - OFF (momentary OFF)
6003 ON - OFF Lit
6008 ON - OFF Lit (Unswitched neutral)
6009 ON - OFF (momentary ON) Lit
(Unswitched neutral)
6010 ON - ON
6011 ON - ON (momentary 1 side)
6030 Indicator
For twin switches and double pole circuits see pages 24 & 25
Lit
In house test
EN1224 EN1223
Examples of printing
C6000AL --- C6000AL ---
C6003PL ---
C6010AL ---
C6030AL ---
C6003AL ---
19
Finish Matt is standard
Colour Call factory for custom colours
A full range is available for large orders
Legend printing Select from the examples
or call factory for custom legends
Lamp voltage Call factory for details
Protective cover (designed to IP65)
The 6000 series is a water thru design.
For a higher level of sealing, a snap on cover
is available (add G after body code). This
reduces panel thickness by 1mm.
Panel sealing washer W46 is available but
reduces panel thickness by a further 0.8mm.
Covers are not suitable for momentary types.
Mounting orientation may affect splashproofing
For all options call the factory
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
L
Matt
BODY DIMENSIONS (mm)
Panel cut-out ** Flange
OPTIONS
2.0 30.0
10.0
8.0
2A 1A
11.1/11.0
30.1/
30.0
14.0
31.5
R2.0
For IP65 see “options” below
Integral Splashproofing
Current carrying parts are protected from moisture.
Droplets which may enter the switch are channelled out
through ports in the switch body
Cut-outs must be punched in the direction of insertion Panel thickness
L0.75 to 2.5mm
** For cut-out details
on momentary switches
call the factory
A Softline Matt
B Splashproof (with Arcshield)
H Slotted (for custom Adaptors)
not momentary
V Curved Matt or gloss
W Splashproof (with Arcshield)
X Two colour Matt
ON - OFF only (not momentary)
F Flat lens Gloss (0430 only)
A Softline lens Matt (0430 only)
as F but with raised profile
20
TERMINAL FUNCTION ROCKER BODY PRINT,COLOUR,VOLTAGE ETC
C1300 A L
---
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
ON - OFF
1500 Standard & 1300 Hi Inrush Switches 150A to IEC65 and 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
On Off Switches - ON when pressed over terminal 1
TERMINAL
Standard
1500
ON - OFF
(momentary ON)
1501
HP rating N/A
C
6.3 x 0.8
H
4.8 x 0.8*
K
2.8 x 0.8*
T
Solder
U
Right angle “T” solder terminal
X
PCB 0.8Sq*
*N/A for 1300 series
9.1
7.0
Ø2.1
1500 Series 16(4)A 250Vac T125
UL CSA 16A Non Ind 250Vac, (2 posn) 250Vac 1hp, 125Vac 1/2hp,
(3 posn) 250Vac 1/2hp, 125Vac 1/4hp UL 85˚C, file E45221, CSA file LR10990
Inrush 36A to EN61058-1 & 20A 28Vdc
1300 series 16(6)A 250Vac T125 5E4 (50,000 Ops.) 150A Inrush to IEC 65,
UL CSA 20A 250Vac 1hp, 125Vac 1/2hp UL 85˚C,file E45221, CSA file LR10990
20A 28Vdc
3mm contact gap except if marked
µ.
Technical data on pages 4 & 5 (switches), 66 (indicators)
9.1
9.1
2.0 1.2
3.2
Ø2.1
9.1
4.0
12 3
ON - OFF
(momentary OFF)
1502
HP rating N/A
ON - ON
1510 µ
HP rating N/A
ON - ON
(momentary 1 side)
1511 µ
HP rating N/A
ON - OFF - ON
1520 µ
125V & 250V 1/2 HP
H terminal rated
T100 only
ON - OFF - ON
(momentary 1 side)
1521 µ
HP rating N/A
H terminal rated
T100 only
ON - OFF - ON
(momentary 2 sides)
1522 µ
HP rating N/A
H terminal rated
T100 only
Indicator
Technical data on page 66
0430
X terminal N/A
In house test
In house test
Matt
Matt
Hi Inrush
1300
Approvals apply to C & T
terminals only
Finish Matt is standard
Colour Call factory for custom colours.
A full range is available for large orders
Legend printing Select from the examples
or call factory for custom legends
Lamp voltage Call factory for details
Blanking plates A0434 - - Dummy units
to fill unused panel holes
Protective cover (designed to IP65)
Snaps on to A, L, Q or T bodies
(add G after body in cat no).
This reduces panel thickness by 1mm.
Panel sealing washer W46 is available for
the same body sizes but reduces panel
thickness by a further 0.8mm
Covers are not suitable for momentary types.
Arcshield
Hides switching arc
For all options call the factory 21
Examples of printing
EN602A EN730 EN822
C1500AL ---
T1500AL ---
C1500AR ---
T1500AR ---
C1520AL ---
T1520AL ---
C1500XL ---
T1500XL ---
C0430AL ---
T0430AL ---
C1510AL ---
T1510AL ---
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
A
Gloss or Matt
B
Matt only
L
Matt only
Q
Gloss or Matt
R
Matt only
T
Matt only
BODY DIMENSIONS (mm)
Panel cut-out *Flange
OPTIONS
12.2/12.3
27.2
27.3
11.0/11.1
30.0
30.1
11.5/11.6
28.2
28.3
11.5/11.6
28.2
28.3
14.0/14.1
28.5
28.6
11.0/11.1
30.0
30.1
14.0
30.2
14.0
33.4
R3.5
14.0
32.0
R1.0
14.0
30.2
R1.6
17.0
31.5
14.0
30.2
R1.6
Cut-outs must be punched in the direction of insertion
feather-edge seal
collar
Enhanced Splashproofing
1500 W and B splashproof options
Feather edge seals and a close fitting collar protect current
carrying parts from moisture.
B option has Hytrel collar/seals for enhanced protection.
Panel thickness
A,Q 0.75 to 3.3mm
L,B,T 0.75 to 2.5mm
R0.75 to 3.0mm
*For cut-out details
on momentary switches
call the factory
2.0 25.3 Max
9.2
13.2
7.6
plunger tube
1300 High inrush, positive break switching
The 1300 series mechanism ensures
contact welds formed at switch-on,
are positively separated by the
plunger tube acting directly on the
step in the moving contact.
step
22
TERMINAL FUNCTION ROCKER BODY PRINT,COLOUR,VOLTAGE ETC
C5503 A L
---
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
A Softline (Matt only)
P Lit window (Matt only)
ON - OFF
ON - OFF
Lit
Unswitched neutral
5500 Lit Rocker Switches - Single Pole16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
On Off Switches - ON when pressed over terminal 3
TERMINAL
5500 µ
5508 µ
for special
applications
C
6.3 x 0.8
H
4.8 x 0.8
T
Solder
9.1
7.0
Ø2.1
16(4)A 250Vac T85
10(3)A 250Vac T100, (12A 250Vac T125 for P rocker only)
UL CSA 15A 250Vac, CSA 16A Non Ind 250Vac
UL CSA 250Vac 1hp, 125Vac 1/2hp
UL 85˚C,file E45221, CSA file LR10990
Inrush 24A to EN61058-1 & 20A 28Vdc
µ
contact gap
Technical data on pages 4 & 5 (switches), 66 (indicators)
For Twin units repeat the order details for both the right and left sides
9.1
12 3
ON - OFF
Lit
Switched neutral
5503 µ
preferred option
In house test
Lit
23
Examples of printing
EN3036 EN3064 EN706
C5503AL --- C5500AL ---
C5503A/C5503AL
C5503PL ---
C5503P/C5503PL
C5503A/C5430AL
Finish Matt is standard
Colour Call factory for custom colours.
A full range is available for large orders
Legend printing Select from the examples
or call factory for custom legends
Lamp voltage Call factory for details
Blanking plate A0434- - (SP) A0494- -(DP)
Dummy units to fill unused panel holes
Protective cover (designed to IP65)
Snaps on to A, L, Q or T bodies
(add G after body in cat no).
This reduces panel thickness by 1mm.
Panel sealing washers W46 (Single Pole) and
W42 (Double Pole) are available for these
body types but reduce panel thickness by a
further 0.8mm
For all options call the factory
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
A
Matt only
B
Matt only
L
Matt only
Q
Gloss or Matt
R
Matt only
T
Matt only
BODY DIMENSIONS (mm)
Panel cut-out ** Flange
OPTIONS
Panel thickness
A,Q 0.75 to 3.3mm
L,B,T 0.75 to 2.5mm
R0.75 to 3.0mm
** For cut-out details on
momentary switches
call the factory
7.6
2.0 28.6 Max
9.2
13.2
12.2/12.3
27.2
27.3
11.0/11.1
30.0
30.1
11.5/11.6
28.2
28.3
11.5/11.6
28.2
28.3
14.0/14.1
28.5
28.6
11.0/11.1
30.0
30.1
14.0
30.2
14.0
33.4
R3.5
14.0
31.9
R1.0
14.0
30.2
R1.6
17.0
31.5
14.0
30.2
R1.6
Twin units
Two single switches or a switch and an indicator light can be
assembled side by side in one double pole body.
For 1500 range panel cut-out details see page 29.
For 5500 range panel cut-out details (L, B and T) call factor y.
For twin units the first set of order format details refer to the
left hand unit, when looking at the front of the assembly
(This has terminal numbers 1, 2 & 3)
1
2
3
4
5
6
1
2
3
4
5
6
Cut-outs must be punched in the direction of insertion
Terminal spacing - Poles 10.8 between centres (twin units)
24
TERMINAL FUNCTION ROCKER BODY PRINT,COLOUR,VOLTAGE ETC
C6053 A L
---
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
C
6.3 x 0.8
H
4.8 x 0.8
S
Screw & Clamp
N/A for assemblies
with 3 terminals in either pole
A Softline
Matt
A Softline
Matt
P Lit Window
Matt
6050 DP Splashproof Switches - IP44 & Twins#16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
On Off Switches - ON when pressed over terminals 3 & 6
TERMINAL
6050 ON - OFF
9.7
9.7
9.7
12 3
45 6
6060 ON - ON
6051 ON - OFF
(momentary ON) 6061 ON - ON
(momentary 1 side)
6062 2 Circuit ON - ON
In house tests only
6052 ON - OFF
(momentary OFF)
6066 ON - O N (Single pole)
(isolated light)
6053 ON - OFF
Lit
6067 ON - ON
Lit
ON - OFF
6054 (momentary ON)
Lit
6068 ON - ON 1pole
ON - OFF Lit 1pole
ON - OFF (Single pole)
6055 (momentary ON)
Lit
6090 ON - OFF 1pole
ON - OFF Lit 1pole
6056 ON - OFF (Single pole)
Isolated light
ON - OFF
6091 (momentary ON)
Lit
6057 ON - OFF
Isolated light
ON - OFF 1 pole
6092 ON - ON 1 pole
Lit
6058 ON - OFF (Single pole)
Lit
ON - OFF
6059 (momentary ON
Isolated light) Circuits are Double Pole
unless described otherwise
European 16(4)A 250Vac T125, 10A 400Vac T125
UL CSA 20A+277Vac, 277Vac 1hp, 125Vac 1/2hp
UL 100˚C,file E45221, CSA file LR10990
Inrush 150A* to EN61058-1
8(8)A 250Vac T125 5E4 on 6050 only
20A 28Vdc
+*applies to non-momentary types
6050 Switches feature “Arcshield” to hide visible switching arc
3mm contact gap with Positive Break switching
# Call factory for IP details on Twin units
Technical data on pages 4 & 5 (switches), 66 (indicators)
Patent app.
In house test
Lit Window
Lit
EN1196 EN1197
Examples of printing
C6050AL --- C6053AL ---
C6003P/C6003PL
C6053PL ---
C6003P/C6030AL
C6000A/C6000AL
25
Finish Matt is standard
Colour Call factory for custom colours.
A full range is available for large orders
Legend printing Select from the examples
or call factory for custom legends
Lamp voltage Call factory for details
Protective cover (designed to IP65 #)
The 6000 series is a water thru design.
For a higher level of sealing, a snap on cover
is available (add G after body code).This
reduces panel thickness by 1mm.
Panel sealing washer W42 is available but
reduces panel thickness by a further 0.8mm.
Covers are not suitable for momentary types.
IP Ratings Call the factory for details
Terminal Link P1067 connects the poles of
a double pole switch or twin unit
#Mounting orientation may affect IP rating
For all options call the factory
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
L Double pole
Matt
L Twin units
Contact factory for information on
splashproofing and IP ratings
Matt
BODY DIMENSIONS (mm)
Panel cut-out *Flange
OPTIONS
Twin units: 2 switches or indicators in one body
Repeat order details for both sides (left side first)
Call factory for IP details on Twin units
Circuits: refer to page 18
Panel thickness
L0.75 to 3.0mm
*For cut-out details on
momentary switches
call the factory
Terminal spacing - Poles 10.5 between centres
2.0 30.0
10.0
8.0
5B 4B
22.2/22.1
30.1/
30.0
25.0
31.5
R2.0
22.2/22.1
30.1/
30.0
25.0
31.5
R2.0
For IP65 see “options” below
Splashproof to IP44
Current carrying parts are protected from moisture.
Droplets which may enter the switch are channelled out
through ports in the switch body
Cut-outs must be punched in the direction of insertion
26
A Softline Matt
B Splashproof (with Arcshield)
V Curved
W Splashproof (with Arcshield)
P Lit window Matt
X Two colour Matt
F Flat lens Gloss (0480 only)
A Softline lens Matt (0480 only)
as F but with raised profile
TERMINAL FUNCTION ROCKER BODY PRINT,COLOUR,VOLTAGE ETC
C1553 A L
---
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
1550 Series 16(4)A 250Vac T125
UL CSA 16A 250Vac, (2 posn) 250Vac 1hp,125Vac 1/2hp,
(3 posn) 250 Vac 1/2hp, 125Vac 1/4hp. UL 85˚C, file E45221, CSA file LR10990
Inrush 36A to EN61058-1 & 20A 28Vdc
1350 series 16(4)A 250Vac T85 1E4 (10,000 Ops.)
On request 16(6)A 250Vac T125 5E4 (50,000 Ops.) & 150A Inrush to IEC 65
UL CSA 20A 250Vac 1hp, 125Vac 1/2hp
UL 72Vdc 7A, 36Vdc 14A. UL 85˚C, file E45221, CSA file LR10990
20A 28Vdc
3mm contact gap except if marked
µ.
Technical data on pages 4 & 5 (switches), 66 (indicators)
ON - OFF
1550 Standard & 1350 Hi Inrush Switches 150A to IEC65 and 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
On Off Switches - ON when pressed over terminal 1
TERMINAL
Hi Inrush
1350
C
6.3 x 0.8
H
4.8 x 0.8*
K
2.8 x 0.8*
T
Solder
U
Right angle T Solder (Not DP)
X
PCB 0.8Sq*
*
Contact factory for details on 1350 series
9.1
7.0
Ø2.1
9.1
9.1
2.0 1.2
3.2
Ø2.1
9.1
4.0
12 3
45 6
In house test
In house test
Standard
1550
ON - OFF
(momentary ON)
1551
HP rating N/A
ON - OFF
(momentary OFF)
1552
HP rating N/A
ON - OFF
Lit
1353
Not W, X or B rocker
1553
Not W, X or B rocker
ON - ON
1560 µ
ON - ON
(momentary 1 side)
1561 µ
HP rating N/A
2 Circuit
ON - ON
1562 µ
In house tests only
ON - OFF - ON
1570 µ
125V & 250V 1/2 HP
H terminal rated T100 only
ON - OFF - ON
(momentary 1 side)
1571 µ
HP rating N/A
H terminal rated T100 only
ON - OFF - ON
(momentary 2 sides)
1572 µ
HP rating N/A
H terminal rated T100 only
3 position selective
OFF - A - A+B
1484 µ
In-house tested to 10(3)A 250Vac
3 position selective
A - B - C
(link not supplied)
1487 µ
In-house tested to 10(3)A 250Vac
Indicator
Technical data on page 66
0480
X terminal N/A
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
“Arcshield” feature hides visible switching arc
Lit (not momentary)
Lit (not momentary)
Lit (not momentary)
Matt or gloss Gloss only
Top view
(On Off only - not momentary)
27
Examples of printing
EN602A EN730 EN822
C1350AL ---
C0480AL ---
C1550XL --- C1553PL ---
Finish Matt is standard
Colour Call factory for custom colours.
A full range is available for large orders
Legend printing Select from the examples or
call factory for custom legends
Lamp voltage Call factory for details
Blanking plates A0494 Dummy units
to fill unused panel holes
Protective cover (designed to IP65)
Snaps on to A, L, Q or T bodies
(add G after body in cat no).This reduces
panel thickness by 1mm.
Panel sealing washer W42 is available for
the above body sizes but reduces panel
thickness by a further 0.8mm.
Covers are not suitable for momentary types.
Arcshield
Hides switching arc
For all options call the factory
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
A
Gloss or Matt
B
Matt only
L
Matt only
Q
Gloss or matt
R
Matt only
T
Matt only
BODY DIMENSIONS (mm)
Panel cut-out *Flange
OPTIONS
Panel thickness
A,Q 0.75 to 3.3mm
L,B,T 0.75 to 2.5mm
R0.75 to 3.0mm
*For cut-out details
on momentary switches
call the factory
2.0 25.3 Max
9.2
13.2
7.6
Terminal spacing - Poles 10.2 between centres
22.3/22.4
27.2
27.3
22.1/22.2
30.0
30.1
22.3/22.4
28.2
28.3
22.3/22.4
28.2
28.3
23.0/25.4
28.4
28.5
22.1/22.2
30.0
30.1
25.0
30.2
25.0
33.4
R3.5
32.0
25.0
R1.0
25.0
30.2
R1.6
28.9
33.2
30.2
25.0
R1.6
C1553AA with M616 guard
Cut-out 22.0/22.1x29.4/29.5
Guard accepts “A body only
Optional snap-in M441 barrier
Cut-outs must be punched in the direction of insertion
plunger tube
1350 High inrush, positive break switching
The 1350 series mechanism ensures
contact welds formed at switch-on,
are positively separated by the
plunger tube acting directly on the
step in the moving contact.
step
TERMINAL FUNCTION ROCKER TERMINAL FUNCTION ROCKER BODY PRINT,COLOUR, ETC
C1500 A/C1510 A L
---
28
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
16(4)A 250Vac T125
UL CSA 16A 250Vac
UL CSA (2 posn) 250Vac 1hp,125Vac 1/2hp,(3 posn) 250 Vac 1/2hp,125Vac 1/4hp
UL 85˚C,file E45221,CSA file LR10990
Inrush 36A to EN61058-1 & 20A 28Vdc
For versions with High Inrush or for 50,000 operations, see pages 20 and 26
3mm contact gap except where marked
µ
Technical data on pages 4 & 5 (switches), 66 (indicators)
For twin units repeat the order details for both the left and right sides
ON - OFF
ON - ON
ON - OFF - ON
Indicator
Technical data on page 66
A Softline (Matt)
B Softlinesplashproof (Matt)
W Curved splashproof (Matt)
X Two colour (Matt) (not momentary)
ON - OFF only
A Softline lens (Matt) (Indicator)
1500 Twin Units Switches and Indicators 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
On Off Switches - ON when pressed over terminal 1 or 4
TERMINAL
1500
1510 µ
HP rating N/A
1520 µ
125V & 250V 1/2 HP, 125V
H terminal rated T100 only
0430
X terminal N/A
C
6.3 x 0.8
H
4.8 x 0.8
K
2.8 x 0.8
T
Solder
X
PCB 0.8Sq
9.1
7.0
Ø2.1
9.1
9.1
2.0 1.2
9.1
4.0
12 3
45 6
In house test
Finish Matt is standard
Colour Call factory for custom colours.
A full range is available for large orders
Legend printing Call factory for custom
legends. S t a te if a legend is to appear on the
right or left hand unit (viewed from the front)
Lamp voltage Call factory for details
Arcshield
Hides switching arc
For all options call the factory
Examples of printing
EN602A EN730
C1500A/C1500AL C1500A/C0430AL
C1500A/C1520AL
C1500X/C1500XL
C0430A/C0430AL
C1520A/C1510AL
29
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
A
Gloss or Matt
B
Matt only
L
Matt only
Q
Gloss or matt
R
Matt only
T
Matt only
BODY DIMENSIONS (mm)
Panel cut-out *Flange
OPTIONS
Twin unit terminal numbering
The first 6 digits of the catalogue number refer to the left hand
unit when looking at the front. (This has terminal nos. 4, 5 & 6)
22.3/22.4
27.2
27.3
22.1/22.2
30.0
30.1
22.3/22.4
28.2
28.3
22.3/22.4
28.2
28.3
23.0/25.4
28.4
28.5
22.1/22.2
30.0
30.1
25.0
30.2
25.0
33.4
R3.5
32.0
25.0
R1.0
25.0
30.2
R1.6
28.9
33.2
30.2
25.0
R1.6
Cut-outs must be punched in the direction of insertion Panel thickness
A,Q 0.75 to 3.3mm
L,B,T 0.75 to 2.5mm
R0.75 to 3.0mm
*For cut-out details
on momentary switches
call the factory
2.0 25.3 Max
9.2
13.2
7.6
Call the factory for terminal spacing details
feather-edge seal
collar
Enhanced Splashproofing
1500 W and B splashproof options
Feather edge seals and a close fitting collar protect current
carrying parts from moisture.
B option has Hytrel collar/seals for enhanced protection.
0
SLIDERTERMINAL SERIES
2
2
Switching
positions
3
Switching
positions
4
Switching
positions
5
Switching
positions
10
6.0
21.0
5.8Sq
531
642
20
531
642
30
531
642
40
531
642
10
531
642
7
8
20
531
642
7
8
30
531
642
7
8
40
531
642
7
8
10
531
642
7
8
9
10
20
531
642
7
8
9
10
30
531
642
7
8
9
10
40
531
642
7
8
9
10
10
531
642
7
8
9
10
11
12
20
531
642
7
8
9
10
11
12
30
531
642
7
8
9
10
11
12
40
531
642
7
8
9
10
11
12
POS’N CIRCUIT
6
6.0
5.8Sq
15.5
D
9.5
5.8Sq
15.5
L
7.9
8.0
2.3
Blade
5.8
15.5
1
36.8
6.0
7.9
5.8
Not 2 position 7
4.0
5.8Sq
15.5
E
8.2 7.0
2.0
Blade
5.8
9.2
21.0
N
7.5
4.2
5.8
21.0
2
1.7
5.8Sq
Ø2.0
Hole
21.0
9
3.5
5.8Sq
15.5
G
6.0
7.9
5.9
36.8
1.4
Slot
Not 2 position P
4.0
7.7
15.5
5.6
3
11.0
5.8 Sq
5.5
15.5
2.4 Slot
A
9.5
5.8Sq
21.0
H
4.7
5.7Sq
21.0
R
2.4
Ø5.0
5.8
15.5
4
3.0
Ø2.5
5.8 Sq
15.5
B
3.0
Ø2.9
5.8 Sq
36.8
Not 2 position J
4.7
5.7Sq
36.5
Not 2 position S
5
1.0
5.8Sq
21.0 Ø2.0
Hole
C
2.3
5.8Sq
13.5 Ø2.0
Hole
K
5.4
8.0
2.3
Blade
5.8
15.5
T
Viewed from back
10A 250Vac T85
6(3)A 250Vac T85
UL CSA 16A 250Vac Non Inductive
UL CSA 4A 300Vac
UL65°C,file no. E45221, CSA file no. LR10990
µ contact gap
Please specify: Standard action (SP116) or Light action (SP118)
2000 series lubrication is inorganic and does not degrade plastics
Technical data on pages 4 & 5
Limited travel on 2 pos
Limited travel on 2 posAlso with legend
Limited travel on 2 pos
Limited travel on 2 pos
Limited travel on 2 pos
9.0
8.0
2.2
Blade
5.8
15.5
4.6
5.8Sq
15.5
K
2.8 x 0.8
R
2.8 x 0.8
T
Solder
X
PCB 0.8 Sq.
Y
PCB 0.8 Sq.
For mounting stability
switches have extra
“support” terminals
* Nominal -
Dimension varies
with body type.
For exact figure
call factory
2.0 7.0*
1.3
5.6*
1.6
5.6*
2.6
2.6 6.0*
1.6
3.6*
O1.2
/
2000 Slide Switches - up to 5 position10A 250Vac
30
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
TERMINAL SERIES POSITIONS CIRCUIT SLIDER BODY PRINT,COLOUR, ETC
T 2 2 20 5 C
---
C 2 positions H 2 positions
BODY DIMENSIONS (mm)
OPTIONS
Cut-out/PCB Matrix
A 3 positions H 3 positions
A 4 positions H 4 positions
A 5 positions
3 Position A body 3 Position H body
4 Position A body 4 Position H body
5 Position A body
5.8
23.0
14.0
11.0
6.0
7.07.0
5.8
30.0
14.0
11.0
6.0
7.0 7.07.0
5.8
30.0
14.9
12.4
6.0
7.0 7.07.0
5.8
37.0
14.0
11.0
6.0
7.07.0 7.07.0
5.8
37.0
14.9
12.4
6.0
7.07.0 7.07.0
5.8
44.0
14.0
11.0
6.0
7.0
7.07.0 7.07.0
6.3
36.3
6.3
22.3
6.3
29.3
6.3
13.3
5.8
23.0
14.9
12.4
6.0
7.07.0
2 Position C body 2 Position H body
6.0
Ø1.3
7.07.0
6.0
Ø1.3
7.07.07.0
6.0
7.0 Ø1.3
7.07.07.0
6.0
7.0 Ø1.3
7.07.07.07.0
for PCB
for PCB
for PCB
for PCB
Colour
For custom slider
colours call the
factory.
A full range is
available for
large orders
31
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
X22205C --- T2220EC ---
T25302A ---
T23206A ---
T25100A ---
T24306A ---
0
SLIDERTERMINAL
2
2
Switching
positions
3
Switching
positions
10
10 A 250Vac T85
6(3)A 250Vac T85
UL CSA 16A 250Vac Non Inductive
UL CSA 4A 300Vac
UL65°C,file no. E45221, CSA file no. LR10990
µ contact gap
Please specify: Standard action (SP116) or light action (SP118)
2000 series lubrication is inorganic and does not degrade plastics
Technical data on pages 4 & 5
6.0
21.0
5.8Sq
115/230 is preferred legend
531
642
20
531
642
30
531
642
40
531
642
10
531
642
7
8
20
531
642
7
8
30
531
642
7
8
40
531
642
7
8
246
POS’N CIRCUIT
2Pos BBody only 6
6.0
5.8Sq
15.5
2&3Pos BBody only
7
4.0
5.8Sq
15.5
2&3Pos BBody only D
9.5
5.8Sq
15.5
2&3Pos BBody only M
4.8
4.1
18.4
FBody only
Legend optional
2
1.7
5.8Sq
Ø2.0
Hole
21.0
2Pos BBody only
8
8.0
4.0
18.4
EBody only E
8.2 7.0
2.0
Blade
5.8
9.2
21.0
2Pos BBody only N
7.5
4.2
5.8
21.0
2Pos BBody only
3
11.0
5.8 Sq
5.5
15.5
2.4 Slot
2&3Pos BBody only
9
3.5
5.8Sq
15.5
2&3Pos BBody only H
4.7
5.7Sq
21.0
2Pos BBody only P
4.0
7.7
15.5
5.6
2&3Pos BBody only
4
3.0
Ø2.5
5.8 Sq
15.5
2&3Pos BBody only
A
9.5
5.8Sq
21.0
2Pos BBody only K
5.4
8.0
2.3
Blade
5.8
15.5
2&3Pos BBody only R
2.4
Ø5.0
5.8
15.5
5
1.0
5.8Sq
21.0 Ø2.0
Hole
2Pos BBody only
C
2.3
5.8Sq
13.5 Ø2.0
Hole
E Body &
2&3Pos BBody only L
7.9
8.0
2.3
Blade
5.8
15.5
2&3Pos BBody only S
9.0
8.0
2.2
Blade
5.8
15.5
Legend optional
Viewed from back
Limited travel on 2 pos
Limited travel on 2 pos
Limited travel on 2 pos
Limited travel on 2 pos
Limited travel on 2 pos
Also with legend
K
2.8 x 0.8
R
2.8 x 0.8
T
Solder
X
PCB 0.8 Sq.
For mounting
stability
switches have
extra “support”
terminals
* Nominal -
Dimension varies
with body type.
For exact figure
call factory
2.0 7.0*
1.3
5.6*
1.6
2.6 6.0*
1.6
3.6*
O1.2
/
2&3Pos BBody only
2&3Pos BBody only
T
4.6
5.8Sq
15.5
2&3Pos BBody only
SERIES
2000 Slide Switches - Snap-in & 2 hole fixing 10A 250Vac
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
TERMINAL SERIES POSITIONS CIRCUIT SLIDER BODY PRINT,COLOUR, ETC
T 2 2 20 5 B
---
32
B With fixing holes
BODY
DIMENSIONS (mm) Cut-out / PCB Matrix
OPTIONS
2 Pos B
2 Pos E
2 Pos F
Panel
thickness Dim.Y
0.8-1.2 29.75/29.85
1.63 30.15/30.25
2.0 30.35/30.45
2.5 30.55/30.65
Panel
thickness Dim.Y
0.8-1.2 29.75/29.85
1.63 30.15/30.25
2.0 30.35/30.45
2.5 30.55/30.65
E Snap-in
230
F Snap-in
(single pole ON OFF only)
23.0
7.07.0
4.0 5.8
1.0
12.0
14.0
6.0
13.3
Panel cut-out
6.3
O3.3
/
34.0
33.0
14.0
10.8
6.0
7.0
7.0
4.0
2.0
27.4
Y
14.35
14.45
10.8
10.8
7.0
11.4
2.0
33.0
27.4
Y
10.85
10.95
30.0
7.0
7.0
7.0
4.0 5.8
1.0
12.0
14.0
6.0
22.3
Panel cut-out
6.3
O3.3
/
38.0
6.0
Ø1.3
7.07.07.0
6.0
Ø1.3
7.07.0
Cut-outs must be punched
in the direction of insertion
Cut-outs must be punched
in the direction of insertion
3PosB
6.0
Ø1.3
7.07.0
Ø1.3
7.0
for PCB
for PCB
for PCB,
call factory for details
for PCB
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
T22208E --- T22308E ---
T22305B ---
T2230MF ---
T23204B ---
T22205B ---
Colour
For custom slider
colours call the
factory.
A full range is
available for
large orders
Standard body
colour is black
Legend printing
A wide range is
available
For all options
call the factory
33
34
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
TERMINAL FUNCTION ACTUATOR BODY PRINT, COLOUR,ETC
H8353 J E
---
C
6.3 x 0.8
H
4.8 x 0.8
K
2.8 x 0.8
T
Solder
X
PCB 0.8 Sq
16(4)A 250Vac T85, 1E4 (10,000 Operations)
12(2)A 250Vac T105, 1E4 (10,000 Operations)
8(8)A 250Vac T105, 5E4 (50,000 Operations)
6(6)A 250Vac T125, 5E4 (50,000 Operations)
12A 250Vac DP, 13A 250Vac SP
250Vac 1hp, 125Vac 1/2hp
UL 85˚C,file E45221, CSA file LR10990
3mm contact gap
Technical data on pages 4 & 5
A Standard actuator
D Custom profile actuator
H Slotted for custom actuators
C Square lens
E Radiused actuator
F Small round actuator
J Smooth curved actuator
8300 Push Button Switches 16A 250Vac
ACTUATORFUNCTION
Approvals & ratings vary with function
Single pole switches use terminals 1 & 2 (& 3)
TERMINAL
8300 ON - OFF Single pole
12
34
8301 ON - OFF (momentar y ON) Single pole
8303 ON - OFF with light Single pole
8304 ON - OFF (momentar y ON) with light
Single pole
8350 ON - OFF Double pole
8351 ON - OFF (momentar y ON) Double pole
8353 ON - OFF with light Double pole
8354 ON - OFF (momentar y ON) with light
Double pole
8.5
2.6
1.5
7.0
4.5
A
As “H” but right
angle 4.8 x 0.8
V
Dual pin PCB
(Call factory for
matrix dims)
7.7
2.6 7.0
1.5
Slots for
snap-in buttons
All actuators except D & H available lit
8.5
10.1
3.7Ctrs
4.3
35
Finish
Matt finish standard except on J and D
actuators which are gloss
Colour
Call factory for custom colours
A full range is available for large orders
Legend printing
Select from the examples or call
factory for custom legends
Special buttons
Some of the many options are shown
Call the factory for the full range
L167 Protective cover
(designed to IP65)
Snaps on to switch bodies fitted with
“A or “J” style actuators but reduces
panel thickness by 0.8mm
EN1153 EN1152
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
Examples of printing
C8350AB --- H8353JE ---
H8350DB ---
H8353EB ---
T8350AB --- T8353JE --- T8353EB ---
H8350HB ---
H8353CB ---
T8350DB --- Example of actuator
T8353CB ---
B Standard body
D As B body but with PCB support peg
E Softline style body with radiused bezel
F As E body but with PCB support peg
Dimensions for snap-in fixing
Panel
thickness Dimension X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
BODY DIMENSIONS (mm)
Panel cut-out Flange
OPTIONS
8.5
4.5
11.0
1.7 "OFF"
"ON"
PCB support peg
(on D body only)
2.0
17.0
R0.5
8.5
4.3
11.0
1.7 "OFF"
"ON"
2.0
17.0
R0.5 R29.6
R12.0
R1.8
PCB support peg
(on F body only)
Spacing between centre of terminals 1 & 3 or 2 & 4 is 10.0mm
X
12.9
21.0
15.0
Cut-outs must be punched in the direction of insertion Actuator A
Body B
Actuator J
Body E
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
TERMINAL FUNCTION ACTUATOR BODY OPTIONS
H8200 A A
---
36
C
6.3 x 0.8
H
4.8 x 0.8
K
2.8 x 0.8
T
Solder
X
PCB 0.8 Sq
M
As V, PCB
but Right angle
A
As H, 4.8 x 0.8
Right angle
V
Dual pin PCB 0.8 Sq
(Call factory for
matrix dims)
16(4)A 250Vac T85, 1E4 (10,000 Operations)
12(2)A 250Vac T105, 1E4 (10,000 Operations)
8(8)A 250Vac T105, 5E4 (50,000 Operations)
6(6)A 250Vac T125, 5E4 (50,000 Operations)
12A 250Vac
250Vac 1hp, 125Vac 1/2hp
UL 85˚C,file E45221, CSA file LR10990
3mm contact gap
Technical data on pages 4 & 5
AStandard actuator for
snap-on custom adaptors
BFlat top actuator
CCurved top actuator
Examples of possible
actuation methods
Using a Snap on adaptor
Using a Hinged Actuator
8200 Push Button Switches16A 250Vac
ACTUATORFUNCTIONTERMINAL
8200 ON - OFF Single pole
12
34
8201 ON - OFF (momentary ON) Single pole
8250 ON - OFF Double pole
8251 ON - OFF (momentary ON) Double pole
10.1
8.5
2.6 7.0
1.5
7.6
7.3
5.3
8.5
2.6
1.5
7.0
4.5
4.3
3.7Ctrs
8.0
5.5
8.0
Facia
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
C8250AA ---
with impact washer M1226
X8201AA ---
M8200AC ---
K8200AA ---
A8200AA ---
37
Example of M8200AC
A
Standard body
See dimensioned drawings for details
C
As standard body but with side support
peg for use with M PCB terminals
See dimensioned drawings for details
D
As standard ‘A’ body but with base
support peg for use with V PCB terminals
See dimensioned drawings ‘A’ for details
BODY DIMENSIONS (mm)
A’ body with ‘H’ 4.8 terminals
12.9
14.5
8.5
12 24
4.0
6.0 sq
1.0 6.5
1.5
26.5
Off
4.3
Full travel
23.5
On
10.0Ctrs
18.9
10.0
10.0
11.0Ctrs
‘C’ body with ‘M’ right angle PCB terminals
26.5
Off
12 24
12.9
5.3
14.5
7.3
12.6
1.3
4.0
6.0 sq
1.0 6.5
1.5 4.3
Full travel
23.5
On
1.3
12.8
7.3
7.3
PCB Hole details
3.7
O2.2/
O1.6 /
18.9
10.0
10.0
11.0Ctrs
A’ body with ‘A’ right angle 4.8 terminals
12 24
18.9
12.9
7.6
14.5
4.0
6.0 sq
1.0 6.5
1.5
26.5
Off
4.3
Full travel
23.5
On
10.0
10.0
11.0Ctrs
Example of possible mounting styles
Impact washer resists damage
from excessive operator force
Alternative Actuator
ACTUATOR
ARound actuator
shown in F body
ARound actuator
shown in G body
SRectangular actuator
Shown in “A body
N/A for 7030
7000 Push Button Switches16A 250Vac
TERMINAL
C
6.3 x 0.8
H
4.8 x 0.8
7000
7001
7003
7004
7050
7051
7053
7054
7030
Single pole ON - OFF
Single pole ON - OFF
(momentary ON)
Single pole ON - OFF
with light
Single pole ON - OFF
(momentary On) with light
Double pole ON - OFF
Double pole ON - OFF
(momentary On)
Double pole ON - OFF
with light
Double pole ON - OFF
(momentary On) with light
Indicator
16(4)A 250Vac T125
8(8)A 250Vac T85
UL CSA 16A Non Ind, 250Vac 1hp, 125Vac 1/2hp
UL65°C,file no. E45221, CSA file no. LR10990
Inrush 35A to EN61058-1 & 16A 28V dc
3mm contact gap
Technical data on pages 4 & 5 (switches), 66 (indicators)
FUNCTION
9.1
9.1 19.5
8.8
21.0
9.7
12
1
2
4
1
3
2
4
1
3
2
4
2
4
In house test
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
38
TERMINAL FUNCTION ROCKER BODY PRINT,COLOUR, ETC
C7053 A F
---
Panel cut-outs
F H GBody types fit either cut-out
A
BODY DIMENSIONS (mm)
OPTIONS
Panel thickness:
A0.8 - 2.5mm
F,G,H 0.8 - 5.0mm
A
F
G
button only
H
7030 Indicator only
Accepts Alens only
Ø28.0
OFF
34.7
4.0
3.5
ON
Ø28.0
43.2
2.0
36.2
8.8
2.0
30.0
24.0
Ø28.0
16.0
3.5
9.8
27.2
27.3
22.4/22.3
25.0/25.2
1.7
1.9 O/ 25.0/25.2
O/ 23.5/23.7
21.0
Cut-outs must be punched in the direction of insertion
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
Finish
Matt finish is standard on bodies
Gloss finish is standard on actuators
Colour
Call factory for custom colours
A full range is available
for large orders
Legend printing
A wide range is available or call the
factory for custom legends
Lamp voltage
Call factory for details of other
available voltages
Protective housing (E)
(designed to IP65)
Covers are available for round body
styles, call factory for details
39
C7000AF --- C7001AF ---
C7053AG ---
C7003AF ---
C7030AH ---
C7050SA ---
TERMINAL FUNCTION ACTUATOR BODY OPTIONS
T1100 A A - - -
T1100AA - - - T1101AA - - -
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
40
1100 Push Button Switches0.125A 125Vac
FUNCTION
A
Actuator without button
B
Softline button
A
For purpose designed
facias and sub-panels
B
Snap-in fixing
Panel thickness Dimension X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
C
2 Hole fixing
1100
ON - OFF
(alternate)
Single pole
1101
ON - OFF
(momentary ON)
Single pole
ACTUATOR BODYTERMINAL
T
2.8 x 0.5
UL 0.125A 125Vac
UL 0.125A 45Vdc
UL file E45221
0.5A 250Vac T85 5E4 (50,000 Operations)
µ contact gap
Technical data on pages 4 & 5
7.0 Min
5.0
Min
Ø3.1
20.0
1
2
7.0
2.5
1.4
3.3sq
4.1
7.6ctrs
2.2
"ON"
"OFF"
21.3
11.9
10.7 Ø2.2
19.0 4.0
7.6ctrs
22.8
X
12.9
13.0
10.0
11.9
4.8
27.7 24.0
15.1 10.1
7.6ctrs
2.0 2.2
"ON"
"OFF"
15.0
21.0
27.0
16.5
In house test
Dimensions (mm)
T1100AA (Enclosure mounting) T1100AC (2 Hole Fixing) No.4 self-tapping screws T1100BB (Snap-in) Cut-outs must be punched in the direction of insertion
0916 - 0920 Push Button Switches0.5A 250Vac
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
41
Finish
Gloss finish for L and S
actuators
Colour
Call factory for
custom colours
A full range is available
for large orders
O
for L and S Actuator
Panel Cut-out
Panel thickness
Both nuts - 2.5mm
No backnut - 4.0mm
A
for V Actuator (stainless steel)
Chamfer profile bezel
Panel Cut-out
Panel thickness - 8.0mm
TERMINAL FUNCTION ACTUATOR BODY COLOUR
T0916 S O - - -
T0916SO--- & T0916LO--- T0916VA ---
0916
SP ON-OFF (momentary ON)
0917
SP ON-ON (momentary 1 side)
0918
SP ON-OFF (momentary OFF)
0919
SP ON-ON (momentary 1 side)
0920
DP ON-OFF (momentary ON)
Self-Wiping - Slow Make & Break
0.5A 250Vac T85
µ contact gap
Technical data on pages 4 & 5
Dimensions (mm)
Nylon S and L actuators Stainless steel V actuator (IP66)
OPTIONSFUNCTION
S
Small Actuator
L
Large Actuator
V
Vandal Resistant IP66
Flat top Stainless steel
ACTUATOR BODYTERMINAL
T
Solder
Ø19.2
Ø7.1
Neck thread - 40 TPI Whit. Actuator travel - 2.5 max Neck thread - 26 TPI Whit. Actuator travel - 2.5 max
Ø10.3
5.0
19.3
5.0
Ø6.0
6.3
Ø10.3
19.3
5.0 19.4
Ø21.5
1.2
5.0
3.3
10.7
Ø10.0
L
S
Black base
Brown base
White base
Black base
White base
50V only
In house test
V
R
Rectangular bezel
B
Large Contact factory for details
E
Long
P
Short
K
with satin chrome bezel
N
with nylon bezel
V
Vandal resistant (911only)
0910 - 0911 Push Button Snap Action Switches 15(4)A 250Vac
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
42
Colour
Call factory for
custom colours
A full range is available
for large orders
Cover M323
Available for “P” actuator
only
Covers have internal nylon nut
B
Panel cut-out
P, K, N & R actuators
Panel thickness
Both nuts 2.5mm
No backnut 4.0mm
A
Panel cut-out
V actuator only
Panel thickness
8.0mm max
B
N/A for V Actuator
Panel Cut-out
Panel thickness
Both nuts 2.5mm
No backnut 4.0mm
A
Stainless steel chamfer profile bezel
for V actuator only
Panel Cut-out
Panel thickness
8.0mm
C
6.3 x 0.8
TERMINAL FUNCTION ACTUATOR BODY COLOUR
C0911 K B - - -
C0911KB ---
C0911RB --- C0911PB --- C0911EB --- C0911BB ---
C0911VA ---
0910
ON - ON
(alternate)
0911
ON - ON
(momentary)
12.5
Dimensions (mm)
RP &EK &NV Vandal resistant designed to IP66
0910 is available with
K and N actuators only
BODY
15(4)A 250Vac T85
UL 15A, 1/2hp 125-250Vac 85˚C,
UL file E91973, CSA file LR98589
Approvals apply to switch mechanism only (34340350COLOOO)
µ contact gap
Full rating details and technical data on pages 50 & 51
Ratings are at full plunger travel
OPTIONSFUNCTION ACTUATORTERMINAL
Ø19.2
Ø12.7 11.1
1.3
21.5
44.0
31.3
15.0
24.8
28.7 10.9
17.8
22.0
44.0
31.3
15.0
24.8
28.7
7.7
8.1(E)
1.7(P) 44.0
31.3
15.0
10.8
24.8
28.7
23.9
20.1
44.0
31.3
15.0 24.8
28.7 20.0
21.5
43
TERMINAL FUNCTION ACTUATOR BODY
K1911 V L
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
K1911VL --- K1961VL ---
1900 Vandal Resistant Switches - Designed to IP66
Ø21.5
16.0
26.5 1.6
142
21.0
Ø18.3
17.6
26.5 1.6
142
142
21.0
Ø15.0
Ø11.8
Dimensions (mm)
Single pole (K1911VA shown) Double pole (K1961VL shown)
TERMINAL FUNCTION
V
Flat top (stainless steel) A
Stainless steel
Chamfer profile bezel
Panel thickness up to 4.0mm
L
Stainless steel
Chamfer profile bezel
Panel thickness up to 4.0mm
K
2.8 x 0.5
T
Solder
X
PCB
1911
ON - ON (momentary 1 side) Single pole
1961
ON - ON (momentary 1 side) Double pole
ACTUATOR
BODY
Ø16.0
Ø19.2
3.4
1.14
2.54
5.3
4.57
7.9
6A 250Vac T85 25E3
2A 250Vac T85 50E3*
6A 250Vac T85
UL file no. E91973
Approvals apply to switch mechanism only
µ contact gap
Ratings shown are at full plunger travel
Switching mechanisms are snap action (not sealed)
Actuator and bezel are stainless steel
*See rating details and technical data on pages 48 & 49
44
TERMINAL FUNCTION ACTUATOR BODY
H8300 R P
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
H8300RP ---
C
6.3 x 0.8
K
Solder
V
Dual pin PCB
H
4.8 x 0.8
T
Solder
X
0.8Sq PCB
8300 Vandal Resistant Switches - Designed to IP66
11.5 5.2
10.316.0
11.0
12
19.0
ON/OFF
Ø15.0
Ø21.5
Dimensions (mm)
8300RP (H terminals shown)
R
Raised top (stainless steel) P
Stainless steel
Soft profile bezel
Panel thickness 0.75 - 3.0mm
For details of alternative panel cut-out
and bezel diameters, call the factory
8300
ON - OFF (alternate) Single pole
8301
ON - OFF (momentary ON) Single pole
8350
ON - OFF (alternate) Double pole
8351
ON - OFF (momentary ON) Double pole
Ø19.2
16(4)A 250Vac T85, 1E4 (10,000 Operations)
12(2)A 250Vac T105, 1E4 (10,000 Operations)
8(8)A 250Vac T105, 5E4 (50,000 Operations)
6(6)A 250Vac T125, 5E4 (50,000 Operations)
12A 250Vac DP, 13A 250Vac SP
250Vac 1hp, 125Vac 1/2hp
UL 85˚C,file E45221, CSA file LR10990
3mm contact gap
Technical data on pages 4 & 5
Switching mechanism not sealed
10.1
7.0
4.5
8.5
3.7Ctrs
4.3
2.6 7.0
1.5
8.5
2.6
1.5
TERMINAL FUNCTION
ACTUATOR
BODY
45
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
TERMINAL FUNCTION ACTUATOR BODY
C0911 V A
0911 Vandal Resistant Switches - Designed to IP66
C0911VA ---
Dimensions
C0911VA
Dimensions (mm)
C0911VA
V
Flat top (stainless steel) A
Stainless steel
Chamfer profile bezel
Panel thickness up to 8.0mm
C
6.3 x 0.8
0911
ON - ON
(momentary 1 side)
12.5
20.0
Ø21.5
24.83.9 Ø21.5
44.0
31.3
15.0
Ø19.2
16(4)A 250Vac T85
UL 16A, 1/2hp 125-250Vac 85˚C,
UL file E91973, CSA file LR98589
Approvals apply to switch mechanism only (34340350COLOOO)
µ contact gap
Full rating details and technical data on pages 50 & 51
Ratings are at full plunger travel
TERMINAL FUNCTION
ACTUATOR
BODY
04102 Push Button Switches16(4)A 250Vac
16(4)A 250Vac T85 (10,000 operations)
Snap action normally open or closed switching
Large overtravel allows actuator / button tolerance
Button shape allows operation by hinged actuators
µ contact gap
UL94 V1 Button and body
Complies with UL Glow wire test - 850˚C Cat D
Additional technical data on pages 4 & 5
Dimensions (mm)
04102-001 04102-001R
FUNCTION
2 Hole fixing
(shakeproof washers not to be used with fixings)
ACTUATOR BODYTERMINAL
6.3 x 0.8
Force when applying
connectors _<80N
6.3 x 0.8
Force when applying
connectors _<80N
04102-001
Single Pole ON-OFF
(momentary ON)
04102-001R
Single Pole ON-OFF
(momentary OFF)
9.7
11.4
9.7
24.5 6.0
22.0
2 Holes
Ø4.5
Ø6.0
26.8
Ctrs
30.0
12.5
10.0
26.8
Ctrs
24.5 6.0
22.0
Ø6.0
2 Holes
Ø4.5
30.0
13.2
(Off)15.0
(Mom On)12.4
(Full Travel) 8.0
(On)15.2
(Mom Off)13.0
(Full Travel) 8.2
22.0
Ø4.5
04102-001
Factored
product
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
46
TERMINAL FUNCTION ACTUATOR BODY
04102-001
32.4
24.1
7.7 23.9
17.3
19.7 12.2
OPTIONSFUNCTION
C
Nylon top plate and fixing neck
Back nut must be fitted
A
Metal top plate and fixing neck
For Low Voltage (up to 50V) only
Back nut must be fitted
0936
ON - OFF
(momentary ON)
0938
ON - OFF
(momentary OFF)
ACTUATOR BODYTERMINAL
C
6.3 x 0.8
0.5A 250Vac
0.25A 250Vdc
µ contact gap
Technical data on pages 4 & 5
Dimensions(mm)
In house test
In house test
0936 - 0938 Push Button Switches0.5A 250Vac
8.3
12.7
12.7
32.4
24.1
22.0 23.9
22.0
20.2 12.2
P
Small round push
K satin chrome bezel
M moulded nylon bezel
both with large round push
Specify Satin chrome or
nylon (black / white) bezel
Push button finish
Gloss finish only
Push button colour
Red, black
for other colours call
the factory
Cover M327
Available for “P” actuator
Covers have internal nylon nut
0936 / 0938 P 0936 / 0938 K / M
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
47
TERMINAL FUNCTION ACTUATOR BODY OPTION
C0936 P A
---
C0936PC - - - C0938MA - - -
SERIES TERMINAL CONTACT GAP OPERATING FORCE FUNCTION
29
1
2
3
4
5
20
(0.5 mm)
60
150
gms
6A 250Vac T85 25E3 - *150g
2A 250Vac T85 50E3 - *60g
6A 250Vac T85 - *150g
2A 250Vac T85 - *60g
UL file no. E91973 * *Operating force
Ratings shown are at full plunger travel
µ contact gap
For sealed snap-action switches contact the factory
7.9
3.5
3.3
PCB i h f
3.5
3.3
3.4
1.14
2.54
5.3
4.57
PCB
LH PCB
RH PCB
Viewed from plunger end
2.8 x 0.5
Solder
290 Series V4 Snap-action Switches Up to 6A 250Vac290 Series V4 Snap-action Switches Up to 6A 250Vac
CO
ON - (ON)
(momentary 1 side)
48
SERIES TERMINAL CONTACT GAP OPERATING FORCE FUNCTION ACTUATOR
29 120 150 CO L002
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
ACTUATOR
No lever
0000
Plain lever
L000
L001
L002
Roller lever
R000
R001
R002
Many alternative actuators are available from fully adjustable tooling
Contact factory for details
TECHNICAL DATA
Mechanical life >5 million operations
Temperature rating T85ºC
Insulation >1,250V
Tracking resistance PTI KB 250
MECHANICAL DATA
High at rest point** 8.92
Trip point** 8.16-8.54
Pre-travel 0.38-0.76
Movement differential 0.15 (max)
Overtravel 0.6 (min)
Operating force (nominal) Release force (min)
60g 10g
150g 50g
**Measured from fixing hole centres to top of plunger
MATERIALS
Body, lid & Plunger
Glass-filled nylon 6.6,VO
Plunger Glass-filled nylon 6.6,VO
Terminals Brass
Moving contact arm Phosphor bronze
Spring Stainless steel
Contacts
Fine silver
Actuator/roller Stainless steel/acetal
L
H3.0
4.2
L
H3.0
3.3
4.8
L000 L001 L002 R000 R001 R002
Dim H 12.23 15.19 19.93 16.97 19.93 24.66
Dim L 17.5 30.0 50.0 15.91 28.41 48.41
293 20 150 CO L000 291 20 60 CO - - - - 294 20 150 CO 0000
292 20 150 CO R000 291 20 150 CO R001 292 20 150 CO 0000
1.5
6.5
2.3
2.5
9.6
6.4 5.1
20.0
7.5
9.1
2.1
5.3
7.0 8.8
O1.5 /
DIMENSIONS(mm)
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
49
SERIES TERMINAL CONTACT GAP OPERATING FORCE FUNCTION
34
(See ratings above
for 340 Series)
39
(See ratings above
for 390 Series)
2
2
3
5
6
40
(1.0 mm)
075
(34 Series only)
Operating force in gms
120
(34 & 39 Series)
350
(34 & 39 Series)
340 Series
16(4)A 250VacT85 50E3 16A 125/250Vac 1/2hp T85*350g All functions
16(4)A 250VacT85 25E3 16A 125/250Vac 1/2hp T85*120g All functions
10(4)A 250VacT85 25E3 10A 125/250Vac 1/4hp T85* 75 g All functions
390 Series
25(4)A 250VacT85 50E3 22A 125/250Vac 1hp T85*350g NO or NC
22(4)A 250VacT85 50E3 22A 125/250Vac 1hp T85*120g NO or NC
20(4)A 250VacT85 10E3 20A 125/250Vac 1hp T85*350g CO
16(4)A 250VacT85 50E3 16A 125/250Vac 1/2hp T85*120g CO
UL file no. E91973 *Operating force
Ratings shown are at full plunger travel
µ contact gap
6.3
12.5
12.5
6.3
12.5
6.3 x 0.8
(34 & 39 Series)
4.8 x 0.5
(34 Series)
4.8 x 0.8
(34 Series)
Solder
(34 Series)
Both end terminals shown
Solder
(39 Series)
340 & 390 Series V3 Snap-action Switches Up to 25(4)A 250Vac
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
50
CO
ON - (ON)
(momentary 1 side)
NO
(ON) - OFF
(momentary On)
NC
ON - (OFF)
(momentary Off)
SERIES TERMINAL CONTACT GAP OPERATING FORCE FUNCTION ACTUATOR
34 340 350 NO ZDSO
ACTUATOR
No lever
L000
Plain lever
ZD00
ZD01
ZD02
Roller lever
ZDS0
ZDS1
Many alternative actuators are available from fully adjustable tooling.
Contact factory for details
TECHNICAL DATA
Mechanical life >10 million operations
Temperature rating T85ºC
Insulation >1,250V
Tracking resistance PTI KB 300
MECHANICAL DATA
High at rest point** 15.93
Trip point** 14.4-15.17
Pre-travel 0.76-1.52
Movement differential 0.25 (max)
Overtravel 1.32 (min)
Operating force (nominal) Release force (min)
75g 25g
120g 40g
350g 100g
**Measured from lower hole centre to top of plunger.
MATERIALS
Body, lid & Plunger
Glass-filled nylon 6.6,VO
Terminals Brass (silver plated for solder) - 34 Series
Brass silver plated - 39 Series
Rocker arm Brass silver plated
Moving contact Phosphor bronze silver plated
Spring Beryllium copper
Contacts
Fine silver (34 Series), silver cadmium oxide (39 Series)
Actuator/roller Stainless steel/acetal
Dummy contacts Glass-filled nylon 6.6,VO
B
A
4.8*
5.7 1.2
B
A
6.1 4.8
5.7 1.2
ZD00 ZD01 ZD02 ZDS0 ZDS1
Dim A 17.0 18.6 25.8 22.2 23.9
Dim B 22.6 33.9 84.4 19.7 31.7
*7.0 & 9.5mm wide levers also available - contact factory
343 40 120 CO ZDS1 342 40 120 CO ZD01 343 40 075 CO - - - -
346 40 350 NC - - - - 346 40 120 NO - - - - 343 40 120 CO L000
NC
NO
COM
3.1 20.2
28.8 12.5
22.2
10.1
15.9 10.3
15.9
4.6
2 x Ø3.2
R2.8
20.5 13.1
2.9
DIMENSIONS(mm) (3 terminals shown)
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
51
Safety Cut-out Switches16A 250Vac
TERMINAL FUNCTION
6.3 x 0.8 ON - OFF
(momentary OFF)
ACTUATOR MOUNTINGORDER CODE
C0320AA
C0320AA
16.1A 250Vac
C0320BB
16(4)A 250Vac 1/2hp
µ contact gap
These safety switches are assembled
with snap-action switches shown on
pages 50 and 51
Technical data, alternative ratings and
approvals are listed on the above pages
10.3
22.2
2 holes
Ø3.2
12.5
6.3 x 0.8
ON - OFF
(momentary OFF)
C0320BB
9.3
9.0
1.5
3 holes
Ø3.0
Ø3.8 8.5
9.0
12.5
Ø20.0
21.7
37.6
22.3
32.3
26.0 2.0
1.0
12.5
2.5
33.3
20.2
28.8
12.5 39.2
2 x Ø3.2
Ø12.7
10.1
15.9
20.5 13.1
Safety requirements for Portable Heaters can be met by the fitting of a safety cut-out switch
The heater will then turn off if overturned
ON
OFF
Dimensions (mm) (for assemblies fitted with 340 & 390 series switches)
C0320AA C0320BB
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
52
TERMINAL FUNCTION ACTUATOR MOUNTING
C0320AA - - -
OPTIONSFUNCTION
L
For Left hinged lid
for 0305/0306 switches
not for 0307 lampholders
View from bulb end
R
For Right hinged lid
for 0307 lampholders
or 0305/0306 switches
View from bulb end
T
Body without flange
for 0305/0306 switches
Top view
S
Body with rear flange
for 0307 lampholders and
for 0305/0306 switches
Top view
MOUNTING BODYTERMINAL
C
6.3 x 0.8
H
4.8 x 0.8
0305 (E14)
ON - OFF
Switch and Lampholder
0306 (E12)
ON - OFF
Switch and Lampholder
0307 (E14)
Lampholder only
(No Switch)
0308 (E12)
Lampholder only
(No Switch)
Dimensions (mm)
and Properties
30.5 5.5
51.0 20.5
21.5
2.0 Ø3.7
R13.0
35.0
4.0
TOP (LID)
25
min
TOP (LID)
25
min
9.1
9.1
The mechanism of this switch/lampholder does not contain mercury
and may be safely used in food storage equipment.
When fitted to the lid of a freezer storage cabinet, the switch will
operate the lamp when the lid is opened to the angle of tilt
shown in the drawing.
0305 Combined Switch / Lampholder for Freezers
2A 250Vac 25 T 85
UL15W 125/250Vac
UL 65˚C,file E116391
For approval status on versions
0306 and 0308 call the factory
Switched units have µ contact gap
Technical data on pages 4 & 5
TERMINAL FUNCTION MOUNTING BODY COLOUR, ETC
C0305 R T - - -
Colour
Call factory for colours.
A full range is available
for large orders
53
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
C0305LT - - -
C0305RT - - -
OPTIONSFUNCTION
R B
Panel cut-out
Panel thickness
0055 1.0 - 1.6
0056 1.0 - 2.6
Flange
0055
ON - OFF
(momentary OFF)
0056
ON - OFF
(momentary OFF)
ACTUATOR BODYTERMINAL
C
6.3 x 0.8
H (0056 only)
4.8 x 0.8
14.3
7.0 16.9
15.0
25.3
7.0 16.3
Ø24.1
6.6
Ø19.05
19.2
9.1
9.1
Dimensions(mm)
C0055RB C0056RB
0055 & 0056
2(0.2)A 250Vac 25T125 5E4
(50,000 operations)
µ contact gap
Technical data on pages 4 & 5
0055 Refrigerator Door Switches
C0056RB ---C0055RB ---
Finish
Gloss finish only
Colour
White is standard
Call factory for
custom colours
TERMINAL FUNCTION ACTUATOR BODY COLOUR, ETC
C0055 R B - - -
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
54
3005 Refrigerator Door SwitchesSplashproof
3005 25W 25T85 5E4 (50,000 Operations) 250Vac
3006 65W 25T85 5E4 (50,000 Operations) 250Vac
These products require 3mm minimum actuator stroke
to ensure switch action and rating above
µ contact gap
Technical data on pages 4 & 5
OPTIONSFUNCTION
B
C
3005 or 3006
Terminal direction (viewed from hinge end)
Panel cut-out Flange
3005 only
Terminal direction (viewed from hinge end)
Panel cut-out Flange
3005
ON - OFF
(momentary OFF)
1mm max travel
to OFF position
3006
ON - OFF
(momentary ON)
3mm min travel
to ON position
ACTUATOR BODYTERMINAL
C
6.3 x 0.8
H
4.8 x 0.8
9.1
9.1
26.0
13.0
13.8
20.3
26.0
R31.0
27.0
9.1max
5.0
R31.0 13.0
4.2
25.0
9.1max
12.1/12.2
25.4
25.5
14.0
30.2
12.1/12.2
25.4
25.5
18.0
30.2
5.0
19.8
9.1max
17.8
R31.0 13.0
4.2
9.1
max
13.8
20.3
26.0
R31.0
Panel thickness 1.0 - 2.5mm Panel thickness 1.0 - 2.5mm
Dimensions(mm) (C terminals shown)
3005 3006
3005
3006
RL B
DS U
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
55
Finish
Gloss finish only
Colour
White is standard
Call factory for
custom colours
A full range is available
for large orders
TERMINAL FUNCTION ACTUATOR BODY COLOUR, ETC
C3005 C B - - -
C3005CB --- C3005BL ---
Dimensions(mm) (“A actuator shown)
3101 uses terminals 1,2
3102 uses terminals 1,2
3111 uses terminals 1,2,3
For details of actuator travel
and switching angles call the factory
23.9
2.4
22.0 19.8 5.7
7.9
1.8
10.2
21
17.6
Max
25.3 11.9
6.7
12.7
Ctrs
29.7
12.8
3
3100 Refrigerator Door SwitchesSplashproof
5A 250Vac 25T85 5E4 (50,000 Operations)
UL CSA 5A 250Vac
UL 85˚C,file E45221, CSA file LR10990
200W 250Vac Lampload (400,000 operations)
µ contact gap
Technical data on pages 4 & 5
Sealed terminals option available. Call factor y for details
OPTIONSFUNCTION
A
B
C
D
E
A
Panel cut-out
Panel thickness 1.0 - 2.5mm
3101
ON - OFF
(momentary ON)
3102
ON - OFF
(momentary OFF)
3111
ON - ON
(momentary 1 side)
ACTUATOR BODYTERMINAL
E
4.8 x 0.5
For sealed terminals
call the factory
7.9
12 3
21
1
2
2
31
17.6
max
15.6
max
23.0
max
17.1
max
15.0
max
27.56
27.31
22.73
22.99
3.68
2.93
3.68
2.93
1.65
1.14 Optional
cut-out
for
orientation
In house test
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
56
Finish
Gloss finish only
Colour
White is standard
Call factory for
custom colours
A full range is available
for large orders
TERMINAL FUNCTION ACTUATOR BODY COLOUR, ETC
E3102 A A - - -
E3102AA - - - E3111BA - - -
Dimensions(mm) (“A actuator shown)
3141 uses terminals 1,2,3,4
3145 uses terminals 3,4
3146 uses terminals 1,2
For details of actuator travel
and switching angles call the factory
17.6
23.9
10.2
7.1
1.9
22.0
12
34
25.3 11.9
6.7
13.3
Ctrs
29.7
12.8
19.8 5.7
8.0
1.8
3140 Refrigerator Door SwitchesSplashproof
5A 250Vac 25T85 5E4 (50,000 Operations)
UL CSA 5A 250Vac
UL 85˚C,file E45221, CSA file LR10990
200W 250Vac Lampload (400,000 operations)
3mm contact gap
Technical data on pages 4 & 5
Sealed terminals option available. Call factor y for details
OPTIONSFUNCTION
A
B
C
D
E
A
Panel cut-out
Panel thickness 1.0 - 2.5mm
ACTUATOR BODYTERMINAL
H
4.8 x 0.8
Standard format is
H terminals
in positions 1 & 2
and
K terminals
in positions 3 & 4
For sealed terminals
call the factory
K
2.8 x 0.8
8.0
8.0
2.6
1.5
34
12 17.6
max
15.6
max
23.0
max
17.1
max
15.0
max
27.56
27.31
22.73
22.99
3.68
2.93
3.68
2.93
1.65
1.14 Optional
cut-out
for
orientation
In house test
3141
ON - ON
(momentary)
3145
ON - OFF
(momentary OFF)
34
1
3
2
4
3146
ON - OFF
(momentary ON)
12
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
57
Finish
Gloss finish only
Colour
White is standard
Call factory for
custom colours
A full range is available
for large orders
TERMINALS FUNCTION ACTUATOR BODY COLOUR, ETC
HK 3141 A A - - -
HK3141AA - - - H3145AA - - -
SPINDLE
A
B
C
D
M
N
P
R
S
L supplied without spindle
9100 Rotar y Switches16A 250Vac
TERMINAL
C
6.3 x 0.8
H
4.8 x 0.8
For approval information on H terminals,
contact the factory
Simple circuits may not use all terminals
Unnecessary terminals may be omitted.
9
2
Switching
positions
3
Switching
positions
4
Switching
positions
5
Switching
positions
6
Switching
positions
9100 switches offer almost infinite
switching options
For this reason it is impractical to show all
the options available
The table below gives an example of a
5 position switching sequence:
OFF, 1, 1+2, 1+2+3, 1+2+3+4
The code for your chosen circuit will be
allocated by our technicians
Please contact the factory for details
Use the blank table to plan your switching
up to 6 positions
16(4)A 250Vac T125
16A 400Vac T125
8(8)A 250Vac T125 5E4 (50,000 Operations)
UL CSA 20A Non Ind 277Vac, 250Vac 2hp, 125Vac 1hp
UL85°C,file no. E45221, CSA file no. LR10990
20A 28V dc
9100 switches are highly versatile with up to 6 positions at 30° intervals and 6 terminals
per switch. For more complex switching (7 positions & over), contact the factory
Two switches may be stacked to give up to 12 terminal switching
Custom spindles of any length, with or without a “D” flat, can be produced from
our infinitely variable tooling. The flat can be at any angle
3mm contact gap
Technical data on pages 4 & 5
SERIES POSITION CIRCUIT
9.2
9.2
1
A
Pos 1
Off Pos 2 Pos 3 Pos 4 Pos 5
2
3
B4
1
A
Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Pos 6
2
3
B4
In house test
26.0
ø6.0 4.5
A/F
ø6.0 22.0
4.5
A/F
ø6.0 10.8
4.5
A/F
ø6.05 12.2
4.65
A/F
ø6.05
12.2
15˚
4.65
A/F
ø6.0 20.0
4.5
A/F
ø6.0 23.0
4.5
A/F
ø6.0 12.2
for 2 gang switching20.1
4.5
A/F
10.8
4.5
A/F
45˚
ø6.0
tel: +44 (0)20 8979 3232 Arcolectric email: info@arcoswitch.co.uk
TERMINAL SERIES POSITIONS CIRCUIT SPINDLE BODY
C 9 5 01 D A
58
35.8
Pos 1
Spindle Movement 3600 in 300 intervals
Pos 2
18.5
12.4
34
B
31.8
32.09.2 9.2
7.0
28.0
6.3x0.8 tabs
2.5AF
Hex hole
18.5
21
A
43
B
12
A
1
A
Pos 1
Off Pos 2
B
Pos 1
Off Pos 2
3B
Pos 1
Off Pos 2
3
A11
A
Pos 1
Off Pos 2 Pos 3
2
1
A
Pos 1 Off
Pos 2 Pos 3
2
3
B4
1
A
Pos 1 Pos 3
2
Off
Pos 2
OFF, 1
3
B
1
A
Pos 1
Off Pos 2 Pos 3 Pos 4
2
OFF,1,2,3
A
Pos 1
Off Pos 2 Pos 3
2
3
B4
3
B4
1
A
Pos 1 Pos 2 Pos 3 Pos 4
2
Pos 1
Off Pos 2 Pos 3
3
B4
3
B4
Pos 1
Off Pos 2 Pos 3 Pos 4
1
A
Pos 1
Off Pos 2 Pos 3 Pos 4
2
3
B
1
A
Pos 1
Off Pos 2 Pos 3 Pos 4
2
B4
1
A
Pos 1
Off Pos 2 Pos 3 Pos 4
2
4
B
1
A
Pos 1
Off Pos 2 Pos 3 Pos 4
B3
3
B4
1
A
Pos 1
Off Pos 2 Pos 3 Pos 4
Off
3
B4
1
A
Pos 1 Pos 2 Pos 3 Pos 4
2
3
B4
1
A
Pos 1
Off Pos 2 Pos 3 Pos 4
2
OFF, 2+3, 2+3+4
A
Standard 2 hole fixing
Recommended fixing
2 off No4 / 3.0mm self tapping screws
5.0mm min penetration into switch body
Snap together body sections withstand
>1.0Nm separation force
Stacked Switches
For more complex switching a
second switch may be stacked
on the first
BODY DIMENSIONS (mm)
OPTIONS
Anti-rotation stops
May be fitted at any of the index positions
to limit the maximum angle of rotation
Panel clearance
A spacer can be fitted to the switch body
to increase the clearance between the
mounting panel and switch terminals
For all options call the factory
28.0
14.0
2 Holes O3.2
/
/
O8.5
OFF, 3
1, 2, 3, 4
OFF, 3, 3+4
OFF, 1+3
OFF,3,4,3+4
OFF, 1, 2+3, 1+3
OFF, 1, 1+2 1+3, OFF, 2+4
OFF, 4, 1+4, 1+2+4
1, OFF, 2
9201
1
A
Pos 1
Off Pos 2
2
OFF, 1+2
9202 9203 9204 9301 9304 9305
OFF, 1, 3, 1+3
9407 9408 9409 9411 9414 9419
OFF, 1+2, 1+4, 1+2+3+4
Off
4
B
1
A
Pos 1 Pos 2 Pos 3 Pos 4
2
9421
OFF, 1+2, 1+4, 1+2+4
Off
1
A
Pos 1 Off
Pos 4Pos 2 Pos 3
2
9422
OFF, 1, 2, OFF
OFF, 1, 1+4, 1+2+4 OFF, 1+3, 1+4, 1+3+4
OFF, 1+4, 2+4, 3+4
9312 9313 9401 9403
1
A
Pos 1
Off Pos 2 Pos 3 Pos 4
2
3
B
OFF, 1, 1+2, 1+2+3
9402 9404 9405
1
A
Pos 1
Off Pos 2 Pos 3 Pos 4 Pos 5
2
3
B4
OFF,1,1+2,1+2+3, 1+2+3+4
1
A
Pos 1
Off Pos 2 Pos 3 Pos 4 Pos 5
2
3
B4
1
A
Pos 1
Off Pos 2 Pos 3 Pos 4 Pos 5
2
3
B4
1
A
Pos 1
Off Pos 2 Pos 3 Pos 4 Pos 5
2
3
B
OFF, 1, 2, 1+3, 1+3+4 OFF, 1+4, 1+3, 2+3, 1+2+3 OFF, 1, 1+2, 1+3, 1+2+3
9501 9503 9504 9505
1
A
Pos 1
Off Pos 2 Pos 3 Pos 4 Pos 5
3
B4
OFF, 4, 1+4, 3+4, 1+3+4
9509
Note
In the circuits on this page,
the symbol shows the
position of the switch cam,
NOT the position of the
spindle flat
3
B
1
A
Pos 1 Pos 2 Pos 3 Pos 4
2
Off
9423
OFF, 3, 1+3, 1+2+3
tel: +44 (0)20 8979 3232 Arcolectric email: info@arcoswitch.co.uk
59
9000 Rotar y Switches For Foot Spas 2A 250Vac
2A 250Vac T85
UL 2A 250Vac, 65˚C, file E45221
µ contact gap
Technical data on pages 4 & 5
A 4-position single pole rotary switch.
All nylon construction, threaded neck and flatted 6.0mm dia. spindle.
Positive detent action, 90° between index positions.
Stops available to restrict rotation.
Various circuits may be obtained by changing the supply and load
connections or by omission of one or two terminals.
Line and loads may be connected to any terminals.
Any three of the four contacts are always connected.
Illustrated loads and line are for example only.
Suitable for class II appliances.
Patent app.
Rotation Stops
Can be specified to limit
the number of switching
positions
OPTIONSFUNCTION
Panel Cut-out
Panel thickness 1.25 - 3.5mm
BODYTERMINAL
T
Solder
9000
Position 1 Position 2
Viewed from terminal side
OFF Loads B+C switched
Position 3 Position 4
Loads A+C switched Loads A+B switched
1.75
5.5
2.75
Dimensions (mm)
450
12.0
12.1 2.4/2.5
14.0/14.1
Ø
6.3
14.5
Ø6.0/5.95
11.79/11.68 x 32TPI Whit
21.0
34.0
34.0
450
5.1 AF
1
24
3
24
3 1
Load C Line in
Load ALoad B
24
3 1
Load C Line in
Load ALoad B
24
3 1
Load C Line in
Load ALoad B
24
3 1
Load C Line in
Load ALoad B
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
60
TERMINAL FUNCTION
T9000 T9000 00 ---
Cover M331 (C Actuator only)
Seal M539
(C,H & U Actuators)
Actuator visible
Cover M1080
(C Actuator only)
Covers have internal nylon nuts
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
C0600HD - - - C0600CC - - -
0600 Lever Switches1A 250Vac0600 Lever Switches1A 250Vac
61
TERMINAL FUNCTION ACTUATOR BODY OPTIONS
C0600 H D
---
OPTIONSFUNCTION
CChromed brass (0600)
UNylon (0600)
GNylon (0600)
HNylon (0600)
SChromed brass stem/
nylon paddle (0602 only)
DNylon neck and top plate
(Used with actuator codes U, G and H)
CMetal neck and top plate
(Used with actuator codes C and S)
Panel thickness - 3.5mm
Back nut must be fitted
Fixing nuts (Standard is M506 & T92)
T5 Hex brass
M506 Hex nylon
T92 Knurled brass
M279 Knurled nylon
0600
ON - OFF
0602
ON - OFF
(momentary ON)
ACTUATOR BODYTERMINAL
C
6.3 x 0.8
Dimensions(mm)
Ø12.7 11.1
1.3
0600 (U actuator shown) 0602
10.1
16.2
4.1
16.0
2.6
15.2
3.0 (M506)
2.0 (T5)
In house test 1A 250Vac
10A 6/24Vdc
3mm contact gap
Technical data on pages 4 & 5
15.0
12.1
27.0
17.0
41.8
14.6
11.0
Keyslot
25.4
12.7
25.4
12.7
14.6
11.0
Keyslot
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
B
Finish is nickel plate
17.5
TERMINAL FUNCTION ACTUATOR BODY OPTIONS
C3900 B A - - -
3900 Splashproof Metal Lever Switches16A 250Vac
62
C
6.3 x 0.8
S
Screw & clamp
available for
On - Off switches only
T
Solder
10.5
10.5
10.5
Ø3.1
TERMINAL ACTUATORFUNCTION
Single pole Double pole
123 123
456
3920 3970
ON - OFF - ON µ
3911 3961
ON - ON
(momentary 1 side)
3910 3960
ON - ON
3902 3952
ON - OFF
(momentary OFF)
3901 3951
ON - OFF
(momentary ON)
3900 3950
ON - OFF
3921 3971
ON - OFF - ON µ
(momentary 1 side)
3922 3972
ON - OFF - ON µ
(momentary 2 sides)
16(4)A 250Vac T85 (3900 & 3950)
10(4)A 250Vac T85 (All other circuits)
UL CSA 20A 125/277Vac (ON-OFF Circuits)
UL CSA 16A 125/277Vac (Other Circuits)
UL CSA 7A 72Vdc, 14A 36Vdc
UL 250Vac 1hp, 125Vac 1/2hp
UL 85˚C,file E45221, CSA file LR10990
Inrush rating - Contact factory for details
Approvals and ratings vary with function
3mm contact gap except where marked µ
Integral O-ring neck seal
Technical data on pages 4 & 5
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
C3900BA ---
C3950BB ---
C3920BA ---
C3972BB ---
Neck Seal M539
Actuator is visible
Cover M1080
Covers have internal nylon nuts
Fixing nuts
Nickel plated brass are supplied
Hex Back nut
Knurled Front nut
Panel thickness 4.0 with backnut
Guard R17-10
Anti-rotation tab can be specified
for guard fitted in On or Off position
Double Pole
(C terminals shown)
0FF
0N
Optional
P232 plate
SP or DP
A
Without terminal barrier
Single pole
B
With terminal barrier
Double pole only
Panel hole (all types)
31.1
1
2
3
10.017.5
Keyway
Ø12.7 11.1
1.3
17.010.517.5
1
2
3
Keyway
15.0
14.0
63
31.0
21.5
31.1
1
2
3
10.017.5
Keyway
*
BODY OPTIONS
29.5
14.0
17.010.517.5
1
2
3
Keyway
*
Single Pole
(C terminals shown)
DIMENSIONS (mm) *Indicates ON position (for On - Off switches)
64
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
TERMINAL FUNCTION ACTUATOR BODY OPTIONS
C1750 H O - - -
1700 & 1750 Lever Switches 16A 250Vac Single and Double Pole
17.5
H
R
The switch is on between centre
terminals (2 & 5) and
the terminals over which the lever
is positioned
16.4
13.8
C
6.3 x 0.8
H
4.8 x 0.8
K
2.8 x 0.8
T
Solder
X
PCB 0.8 Sq
ACTUATORFUNCTION
Single pole Double pole
TERMINAL
1700 1750
ON - OFF
1710 µ1760 µ
ON - ON
1720 µ1770 µ
ON - OFF - ON
1721 µ
ON - OFF -ON
(momentary 1 side)
1722 µ
ON - OFF - ON
(momentary 2 sides)
16(4)A 250Vac T85
UL 20A 250Vac Non Ind (Single pole)
UL 16A 250Vac Non Ind (Double pole)
UL CSA (2 pos types) 250Vac 1hp, 125Vac 1/2hp
UL CSA (3 pos types) 250Vac 1/2hp, 125Vac 1/4hp
CSA 16A 250Vac Non Ind
UL 85˚C,file E45221, CSA file LR10990
UL and CSA N/A on momentary types
Inrush 36A to EN61058-1 & 20A 28Vdc
Selective “A, B, C” and “Off,A,A+B” circuits at 5 amp also available
3mm contact gap except where marked µ
Technical data on pages 4 & 5
9.1
9.1
9.1
2.0 1.2
7.0
Ø2.1
9.1
4.0
12 3
12 3
45 6
In house test
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
65
C1700RO ---
C1760RO ---
C1700HO ---
C1750HO ---
Neck Seal M539
Rubber -57T145
(H & R Actuators)
Actuator visible
Cover M1080
Rubber -57T145
(R Actuator only)
Cover M331
PVC -5T85
(R Actuator only)
Covers have internal nylon nuts
Fixing nuts (Standard is M506 & T92)
T5 Hex brass
M506 Hex nylon
T92 Knurled brass
M279 Knurled nylon
30.2
25.0
19.2
10.0
Keyway
Double Pole
(C terminals shown)
Optional terminal barrier M441 is available
0FF
0N
Optional
P232 plate
SP or DP
O
Single pole
O
Double pole
Panel hole (all types)
Panel thickness (Max)
Both nuts - 3.5mm
Less backnut - 6.5mm
19.2
10.0
Keyway
Ø12.7 11.1
1.3
12.2
10.0
Keyway
BODY OPTIONS
25.5
13.7
12.2
10.0
Keyway
Single Pole
(C terminals shown)
DIMENSIONS (mm)
16.2
4.1
16.0
2.6
15.2
3.0 (M506)
2.0 (T5)
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
66
Authority
European
UL
Technical Information - Indicators
The majority of Arcolectric indicator lights can be supplied with alternative light sources:
Neon, Fluorescent, Filament lamp or LED.
NEON and FLUORESCENT LAMPS
Colours
Red,Amber and Clear neon, Green fluorescent.
Maximum striking voltages
Standard brightness types 65Vac 90Vdc,
High brightness types 85Vac 135Vdc.
High brightness types are usually fitted.
Life
Typically 25,000 hours (Green fluorescent lamps 20,000 hours).
(Measured to a point when the light output of the lamp is half its
original level.)
The end of life for a neon lamp is not usually a sudden failure.
False signals due to long wiring
It is possible for neon or fluorescent tubes to glow when they should be
off. The false signal is caused by the capacitance effect of fairly long
wiring to the indicator being adjacent to other live cables.
This effect can be prevented in most cases by fitting a 100K resistor
across the supply wires close to the indicator assembly.
MATERIALS
Moulded bodies and bases Nylon 6.6
Metal bodies and bezels Chrome plated brass (except #)
Lenses Polycarbonate
Terminals (most types) Brass (electro-tin plated)
Terminals (exceptions) Brass (flash silver* or nickel** plated)
Threaded metal nuts Brass (nickel plated on 0275/7)
Other fixings Call factory for details
* R9, 0061, 0062, 0430, 0480, 1090, 1091, 6030, 7030, 8630, 8580
** # 3130, 3160, 3161, 3221 have nickel plated terminals with steel
screws and plated polyamide bezel trims
SYMBOLS
TEMPERATURE RATING
FILAMENT LAMPS
Colours
Red,Amber, Green, (Clear and Blue - check availability)
LEDS
Colours
Red,Yellow and Green.
Voltage
Basic voltage 2.0/2.2V. Some items are available with integral
resistors for 12V use. For details of resistors required for higher
voltages, please call the factory.
Current
Maximum continuous forward current 35mA.
Life
>100,000hrs
Polarity
LED flat side is - negative, round side + positive.
Terminals Wire leads Solid wires Panel hole size Panel thickness Temperature rating
C 6.3, H 4.8, K 2.8 200mm long Standard LED only
with Terminals with Wire leads
PVC SILICONE
T125°C T125°C
T105°C
T65/75°C T65/75°C
0.9
14.0 32.5 1.5 Ø6.7
Ø7.6
10.2 4.3
22.6 4.3 Ø7.6
Ø7.64.2
22.5
Ø7.5
Ø9.0
12.6
3.9
27.0
Ø9.5
7.912.5 13.7
18.0 Ø9.5
11.0
TERM TYPE
DIMENSIONS(mm)
5.8
3.0max
page 66
6.3
6.3max
page 66
6.3
10.0max
page 66
7.1
6.3max
page 66
8.0
0.8-1.6
page 66
8.0
0.8-3.0
page 66
PANEL & ˚C
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
67
(L) 1041 OO Chrome bezel
(L) 1045 OO Chrome bezel available
(L) 0245 OO Chrome bezel available
L 2950 OO Chrome bezel available
(C) 0145 AA
(L) 0195 BB
To create a catalogue number:
Refer to the 2 columns below (terminal and type)
Then state:
Lens colour, voltage and whether neon, LED or filament lamp
Indicator Lights(Neon, LED and Filament Lamp)
Colours and voltages:
Neon Red,Amber, Green, Clear
100/130V (marked 110V), 200/250V (marked 230V)
LED Red,Yellow, Green
2.0/2.2V Resistors for other voltages available
Filament lamp Red,Amber, Green, (Clear & Blue check availability)
6V, 12/14V, 24/28V
UL file E63363 CSA file LR29381
C6.3
L
W
L
W
L
W
L
L
C6.3
Ø7.5
Ø9.8
3.7
8.527.0
3.0
27.5
27.5
13.0 9.5 Ø10.0
2.3
27.5
27.5
13.0 9.5 Ø9.5
32.8 3.1 Ø12.2
33.5
22.2
8.5
max
23.0 12.0
3.0
19.0
Ø10.0
12.0 Sq.
23.5 3.5
23.5
22.3
*Final suffix (X) - Long barrier
*Final suffix (Y) - Short barrier
*Final suffix (W) - For Wires
*Final suffix (X) - Long barrier
*Final suffix (Y) - Short barrier
*Final suffix (W) - For Wires
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
68
Indicator Lights(Neon, LED and Filament Lamp)
To create a catalogue number:
Refer to the 2 columns below (terminal and type)
Then state:
Lens colour, voltage and whether neon, LED or filament lamp
Colours and voltages:
Neon Red,Amber, Green, Clear
100/130V (marked 110V), 200/250V (marked 230V)
LED Red,Yellow, Green
2.0/2.2V Resistors for other voltages available
Filament lamp Red,Amber, Green, (Clear & Blue check availability)
6V, 12/14V, 24/28V
UL file E63363 CSA file LR29381
(H) 0568 A(*) Deep lens profile
(VDE at T100)
(VDE at T100)
(H) 0568 B(*) Shallow lens profile
L 2951 OO Chrome bezel available
DIMENSIONS(mm)
(C) 0273 OO
(L) 0569 AW
(C) 0278 OO
L
K2.8
H4.8
L
K2.8
H4.8
L
C6.3
K2.8
H4.8
L
L8.0
0.8-1.6
page 66
8.0
0.8-3.5
page 66
8.0
0.8-3.5
page 66
9.0
2.0 max
page 66
9.0
0.8-2.5
Call
factory
9.0
2.0 max
page 66
L
C6.3
K2.8
H4.8
TERM TYPE PANEL & ˚C
53.7 3.3 8.3
14.9
32.2
22.2 Ø14.6
33.7
4.0
33.0
22.2 Ø12.0
32.5
22.2
16.0
32.7
3.0 Ø13.3
3.5
32.5
32.0
22.2
16.0
32.7
3.0
Ø13.3
Ø15.6
For sub-panel mounting, behind a facia
33.7
4.0
33.0
22.2 Ø12.0
18.4 16.6 Ø8.8
35.7
22.2
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
69
(C) 0277 OO Chrome bezel
(C) 0276 OO
(C) 0275 OO
(C) 0275 OO Chrome bezel
(C) 0276 AA
(C) 0273 LL
DIMENSIONS(mm)
9.5
0.8-2.8
page 66
10.0
12.0 max
page 66
10.0
11.5 max
page 66
10.0
2.8 max
page 66
10.0
12.0 max
page 66
10.0
0.6-2.0
page 66
TERM TYPE PANEL & ˚C
L
C6.3
K2.8
H4.8
L
C6.3
K2.8
H4.8
L
C6.3
K2.8
H4.8
L
C6.3
K2.8
H4.8
L
C6.3
K2.8
H4.8
L
C6.3
K2.8
H4.8
5.0
22.8
10.0 Ø13.6
1.8
25.1
10.0 15.5 Sq
5.0
22.8
9.9 Ø13.6
Ø14.5
22.8 1.6
10.0
Ø18.3
11.418.0
Ø16.0
Ø15.9
21.6
10.5 3.2
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
(C) 2820 OO
(C) 2821 OO
(C) 0586 OO
70
(C) 2870 OO
To create a catalogue number:
Refer to the 2 columns below (terminal and type)
Then state:
Lens colour, voltage and whether neon, LED or filament lamp
Colours and voltages:
Neon Red,Amber, Green, Clear
100/130V (marked 110V), 200/250V (marked 230V)
LED Red,Yellow, Green
2.0/2.2V Resistors for other voltages available
Filament lamp Red,Amber, Green, (Clear & Blue check availability)
6V, 12/14V, 24/28V
UL file E63363 CSA file LR29381
L 0081 OO Chrome bezel
(C) 0589 OO
Indicator Lights(Neon, LED and Filament Lamp)
DIMENSIONS(mm)
12.0
0.75-2.0
page 66
12.5
0.8-1.5
page 66
12.0 or 12.7
page 66
Ø12.0
= 0.8-2.5
Ø12.7
= 1.1-2.5
12.7
0.75-2.0
page 66
12.7
0.8-1.5
page 66
12.7
9.5
page 66
TERM TYPE PANEL & ˚C
L
C6.3
K2.8
H4.8
L
C6.3
K2.8
H4.8
L
C6.3
K2.8
H4.8
L
C6.3
K2.8
H4.8
L
C6.3
K2.8
H4.8
L
3.2
25.4
10.0 Ø15.9
5.1
38.1 Ø16.0
5.1
22.310.4
1.3
21.3
Ø15.0
5.1
22.310.4 Ø16.3
Starlock fixing
22.2
14.9
3.3 8.3
53.7
32.2
Ø14.6
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
71
(C) 0579 OO
(C) 0067 OO Chrome bezel
(C) 0180AA
(C) 0180BB Chrome bezel
(C) 0177 OO Chrome bezel
DIMENSIONS(mm)
L
C6.3
K2.8
H4.8
L
C6.3
K2.8
H4.8
L
C6.3
K2.8
H4.8
L
C6.3
K2.8
H4.8
L
C6.3
K2.8
H4.8
12.7
12.0max
page 66
12.7
1.14max
page 66
12.7
19.0max
page 66
13.5
0.9-1.14
page 66
14.0
2.5max
page 66
TERM TYPE PANEL & ˚C
14.6 8.5
8.67.912.5 13.7
18.0
10.7 8.5
14.6
23.5
30.2
25.1
26.3
32.3
11.3 8.0
9.0
3.3
4.3 11.0
60.0
Ø6.4
Red &
Amber
L77
M1068
Red
only
12.0
29.4 34.6
13.2 5.0
19.0
9.0 2.0 8.0
20.0
18.0
6.0
9.7
Neon tube, resistor and flexible lead assembly,
protected by “shrunk on” transparent sleeving
TERM TYPE PANEL & ˚C
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
72
L 0195 OO
H 0581 AY
(C) 0196 AA
C 0582 AY
L 0234 OO
L 0233 OO
Indicator Lights(Neon, LED and Filament Lamp)
To create a catalogue number:
Refer to the 2 columns below (terminal and type)
Then state:
Lens colour, voltage and whether neon, LED or filament lamp
* Call factor y for details
Colours and voltages:
Neon Red,Amber, Green, Clear
100/130V (marked 110V), 200/250V (marked 230V)
LED Red,Yellow, Green
2.0/2.2V Resistors for other voltages available
Filament lamp Red,Amber, Green, (Clear & Blue check availability)
6V, 12/14V, 24/28V
UL file E63363 CSA file LR29381
DIMENSIONS(mm)
H4.8
C6.3
L
L
C6.3
L
L
2.0-3.5
page 66
18.2/18.3
x
6.2/6.3*
0.8-2.3
page 66
32.5/32.6
x
10.0/10.1*
0.71-1.62
page 66
9.27/9.50
x
4.75*
page 66
13.0x6.5
0.8-3.0
page 66
13.0x6.5
0.8-3.0
page 66
H 4.8
H4.8
TERM
Indicator Lights(To match 8500, 8600, R13, 1500, 1550, 5500, 6000, 8300 and 7000 switches)
For full product details, to create a catalogue number
or to order:
Refer to the catalogue page shown against each item
UL file E63363 CSA file LR29381
H8580 AB
C0430 A(*)C6030 AL
C0480 A(*)
C7030 AH
C 6.3
T U
K 2.8
C6.3
TU
H4.8
K2.8
C 6.3
H 4.8
DIMENSIONS(mm)
Y
X21.0
15.0
Body Panel Cut-out
Code thickness X Y
B0.75-1.25 19.1/19.2 12.9/13.0
1.25-2.0 19.3/19.4 12.9/13.0
2.0-3.0 19.7/19.8 12.9/13.0
Y
X
Y
X
Body Cut-out Flange
*Code Y X Y X
A12.2/12.3 27.2/27.3 14.0 30.2
B11.0/11.1 30.0/30.1 14.0 33.4
L11.0/11.1 30.0/30.1 14.0 31.9
R14.0/14.1 28.5/28.6 17.0 31.5
Y
X
Y
X
Body Cut-out Flange
*Code Y X Y X
A22.3/22.4 27.2/27.3 25.0 30.2
B22.1/22.2 30.0/30.1 25.0 33.4
L22.1/22.2 30.0/30.1 25.0 32.0
R23.0/25.4 28.4/28.5 28.9 33.2
Ø28.0
Body Cut-out Flange
Code
HØ25.0/25.2 Ø28.0
25.0/25.2
Cut-out Flange
Full product details on pages 10-11
Cut-out Flange
Full product details on pages 18-19 & 20-21
Cut-out Flange
Full product details on pages 26-27
Cut-out Flange
Full product details on pages 38-39
H 4.8 R9 92B Cut-out Flange
Full product details on pages 16-17
Snap fixing in panels thickness up to 3.0
0.9
Ø20.2
2.2
Ø23.0
H 4.8
T
X
H8630 FB Cut-out Flange
Y
X
21.0
15.0
Body Panel Cut-out
Code thickness X Y
B0.75-1.25 19.1/19.2 12.9/13.0
1.25-2.0 19.3/19.4 12.9/13.0
2.0-3.0 19.7/19.8 12.9/13.0
Full product details on pages 12-13
6030 - L body
& C terminals only
Approvals details - contact the factory
Factored
product
73
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
Colours and voltages:
Neon Red,Amber Green, Clear
100/130V (marked 110V), 200/250V (marked 230V)
LED Red,Yellow, Green
2.0/2.2V Resistors for other voltages available
Filament lamp Red,Amber, Green, Clear and Blue
6V, 12/14V, 24/28V
TYPE
Neon & LED Indicator Lights Sealed to IP52 and IP54
3161 Satin chrome style bezel
3130 No bezel
3160 Black bezel
3221 Large black bezel
36.0 9.0
Ø13.0
Ø18.0
34.0
2.0
45.0
Ø16.0
4.0
Ø20.5
34.0
2.0
45.0
Ø16.0
4.0
Ø20.5
38.0 2.0
45.0
Ø22.0
14.0
Ø30.0
0
Select the version most suitable for your application
from the 4 types shown
Or call the factory for availability
to your special requirements
Factored
product
Factored
product
Factored
product
Factored
product
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
Recessed
Screw
To order
Select a number from the “type” column
Then state:
Lens colour, voltage and whether neon or LED
All versions have recessed screw terminals
IP52 is standard. A panel sealing washer is available for IP54
Recessed
Screw
Recessed
Screw
Recessed
Screw
DIMENSIONS(mm)
74
Colours and voltages:
Neon Red,Amber, Green
120/230Vac 0.5W (Red base)
LED Red,Amber, Green
28Vac/dc 1W (Green base)
Neon versions feature integral current limiting & ghost lighting resistors
LED versions have rectifier diodes & resistors for direct connection to 28Vac/dc
TERM TYPE PANEL & ˚C
13.2
8.0max
T120 neon
T50 LED
16.2
5.0max
T120 neon
T50 LED
16.2
5.0max
T55 neon
T50 LED
22.3
4.5max
T120 neon
T50 LED
Ø16.05.1
44.5
9.1
21.3 Ø14.7
Low Voltage Lampholders
Front of panel bulb replacement
9.1
21.3 Ø14.7
Front of panel bulb replacement
6.3 23.7 4.8 Ø12.7
Rear of panel bulb replacement
Rear of panel bulb replacement
Paired Architectural lampholders with philinea lamp
38.1
33.3
17.5
13.5
4.7mm CS Hole
25.4
9.5
0.9-1.14
T85
12.7
1.14max
T85
12.7
9.6max
T85
12.7
9.6max
T85
T85 75
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
To create a catalogue number:
Refer to the 2 columns below (terminal and type)
Then state:
Lens colour and voltage
Colour and voltage:
These lampholders are suitable for up to 50V max.
Bulbs will be supplied (dependent on order quantity)
if a voltage is specified
Colours - Red,Amber, Green, (Clear & Blue, check availability)
C0067 OO (BA7s) Chrome bezel
T0062 AO (Midget flange) Chrome bezel
T0063 AO (LES) Chrome bezel
T0061 AO (LES)
T0063 MO (LES)
S0095 OO
T0062 MO (Midget flange)
DIMENSIONS(mm)
TERM TYPE PANEL & ˚C
T
C6.3
T
T
S
LED Lamps and LED Lampholders
LED Lampholders can be supplied with or without lamps
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
TERM TYPE
PANEL & ˚C
DIMENSIONS(mm)
To create a catalogue number:
Refer to the 2 columns below (terminal and type)
Then state:
LED colour and voltage and body finish (Black or Chrome)
Colours: Red,Yellow and Green LEDs
(High Intensity is standard. Option of extra super bright)
Voltages: LEDs are available for direct connection to 2.0/2.2V. or 12Vdc
For other voltages contact the factory
Ø10.0
12.4 2.9
16.9
Ø9.5
10.0 2.0
14.5
Ø10.0
13.4 2.9
17.9
Ø9.5
10.0 2.0
14.5
Ø7.6
12.7
13.9
1.5
Ø7.6
12.7
13.9
1.5
W
LED fitted
A
LED not fitted
W
LED fitted
A
LED not fitted
L
LED & Wires fitted
L
LED & Wires fitted
L
LED & Wires fitted
W
LED fitted
A
LED not fitted
L 1047 OO
(W) 1048 OO
L 1048 OO
(W) 1050 OO
(W) 1047 OO
L 1050 OO
5mm LED with focusing reflector
5mm LED with focusing reflector
5mm LED
5mm LED
3mm LED
3mm LED
76
6.3
6.3max
T85
6.3
6.3max
T85
8.0
5.5max
T85
8.0
5.5max
T85
8.0
7.0max
T85
8.0
7.0max
T85
LED Lamps and LED Lampholders - Designed to IP66
LED Lampholders can be supplied with or without lamps
TERM TYPE
PANEL & ˚C
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
77
To create a catalogue number:
Refer to the 2 columns below (terminal and type)
Then state:
LED colour and voltage and body finish (Black or Chrome)
Colours: Red,Yellow and Green LEDs
(High Intensity is standard. Option of extra super bright)
Voltages: LEDs are available for direct connection to 2.0/2.2V. or 12Vdc
For other voltages contact the factory
Properties
Sealing
O-ring sealing equivalent to IP66, of both the LED to bezel, and bezel to
panel is available where shown
Polarity
The nylon base mouldings are polarity marked
Body Material and Finish
Chromed brass or Black oxide coated brass
Lampholders only
Items prefixed ‘A’ are supplied without LEDs
LED wires or PVC covered wire leads
125mm min length wires, 6.3mm standard strip
Alternative colours, length and strip available
DIMENSIONS(mm)
Ø 10.0
13.4 2.9
17.9
1.0
Ø 9.5
11.0 2.0
15.5
1.0
Ø10.0
13.4 2.9
17.9
1.0
Ø 9.5
11.0 2.0
15.5
1.0
W
LED fitted
A
LED not fitted
W
LED fitted
A
LED not fitted
L 1048 OA Designed to IP66
(W) 1050 OA Designed to IP66
L 1050 OA Designed to IP66
(W) 1048 OA Designed to IP66
5mm LED
5mm LED
5mm LED with focusing reflector
5mm LED with focusing reflector
L
LED & Wires fitted
L
LED & Wires fitted
8.0
5.5max
T85
8.0
5.5max
T85
8.0
7.0max
T85
8.0
7.0max
T85
Low Voltage Lampholders with sealing option
DIMENSIONS mm
78
A
TERMINAL LAMP CAP LENS BODY VOLTAGE, COLOUR, ETC
C1090 F A - - -
LAMP CAP
F
Flat
V
Domed
N/A for L & M body
L
No lens
1090
E10
1091
BA9s
LENS THREADED BODYTERMINAL
C
6.3 x 0.8
Bulbs will be supplied (dependant on order quantity)
if a voltage is specified
These lampholders are suitable for up to 50V max.
Colours - Red,Amber, Green, (Clear & Blue, check availability)
Brass bodies have polished chrome finish
C1090FP - - - C1090FL - - -
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
A19.0 Brass 35.0
D19.0 Brass 30.2
E19.0 Nylon 30.2
*P 19.0 Nylon
(+ chrome trim)
30.2
G19.0 Brass 24.6
H19.0 Nylon 24.6
L25.4 Brass 30.2
All E10 and BA9s types are suitable
for panel thickness up to 6.2mm.
Some versions will accept panels
up to 11.2mm thick
B19.0 Brass 35.0
C19.0 Nylon 35.0
*Q 19.0 Nylon
(+ chrome trim)
35.0
M25.4 Brass 41.8
Panel Body Dimension
Hole Dia. Material A
for BA9s types
Panel Body Dimension
Hole Dia. Material A
for E10 types
OPTIONS
Sealing
Neoprene washers to seal between
bezel and panel (W23)
and lens and bezel (W24) to give a
seal equivalent to IP66 are available
on most versions
F0445 MO
P.V.C. Insulating terminal cover.
*Note P and Q body codes denote a
nylon body fitted with a chrome
bezel trim (previously F0413PO)
9.1
TERMINALTYPE
IEC Connectors & NEMA Receptacles
DIMENSIONS(mm) View below is at Y
S
2.5 Solder
0711-1S
10A 250Vac
UL CSA 10A 250Vac UL 65°C
Terminal data shown at section end
For stock availability & additional options call the factory
36.5
39.8 R1.0
34.7
34.9
35.1/35.3
R2.0 +0
-2.0
21.0
Inlet with Voltage Select
SP 2 position switch is standard
15A 250Vac
10A 250Vac
15A 250Vac
10A 250Vac
15A 250Vac
0710-PV16 is 13A 250Vac.0710-PV12 is 15A 250Vac
15A 250Vac
10A 250Vac
Rating/approval details on request
9.0 18.2 X
22.3
10.3
27.4 40.0
19.8
Ø3.5
R3
50.0
22.5
20.6
27.0
27.0
24.0
X
24.6
27.0
27.0
30.5
Outlet
Outlet
Outlet
Inlet
32.4 40.0
24.2
Ø3.5
R3
50.0
29.0
25.0
26.7
X
R2
31.0
24.0
20.8
Inlet
Y
Y
Y
Y
Y
Y
Panel X
thickness
0.8 - 1.2 24.6
1.3 - 2.0 24.8
Panel thickness:
0.8 or 1.0 or 1.2
Call factory
for details
Panel X
thickness
0.8 - 1.2 20.3
1.3 - 2.0 20.5
Panel X
thickness
0.8 24.0
1.0 24.6
1.2 25.2
1.6 26.2
N
4.0 Solder
Q
4.8 Tab
W
6.3 Tab
N
4.0 Solder
Q
4.8 Tab
W
6.3 Tab
P
PCB
L
4.0 Solder
Q
4.8 Tab
V12
Solid Wire
V16
Solid Wire
LS
2.8 Solder Connector
Q
4.8 Tab/Solder Connector
T
3.0 Solder Switch
K
2.8 Solder Switch
S
2.5 Solder
N
4.0 Solder
Q
4.8 Tab
W
6.3 Tab
To order:
State type number, connector terminal code, switch terminal code (if applicable),
and for snap-in items, the panel thickness. Stocked items are for 1.0mm panels
TYPE TERMINAL TERMINAL PANEL
(connector) (switch) thickness
0711-1S LS K1.0mm
Factored
product
Factored
product
Factored
product
Factored
product
Factored
product
Factored
product
0708-1-C
0709-P
0710-P
0711-P
(2k min order)
0707-1-C
(2k min order)
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
79
IEC Connectors & NEMA Receptacles
36.0
O3.5
/
27.0
31.4
R2.0 +0
-2.0
27.0
27.2
X
R2.0 +0
-2.0
30.0
33.0
20.6
44.0
33.0
20.6
27.9
28.1
46.9/47.1
R2.0 +0
-2.0
30.5
50.0 R3.0
20.7
DP non-illuminated switch is standard
O3.5
/
R2.0 +0
-2.0
27.3
27.5 25.7
36.3
31.3/31.5
44.0
34.0
20.7 32.2
10A 250Vac
10A 250Vac
10A 250Vac
10A 250Vac
Y
Y
Y
Y
Panel X
thickness
0.8 - 1.2 31.4
1.3 - 2.0 31.6
Panel thickness:
0.8 or 1.0 or 1.2
Call factory
for details
0717-2-C For applications (eg medical equipment) where both live & neutral feeds must be fused
TYPE DIMENSIONS(mm) View below is at Y
0717-C
0717-1S State “Non Lit”
3b1a
4b2a
0717-1-P
Switched Fused Inlet 5x20
Fused Inlet 5x20
Fused Inlet 5x20
Double Fused Inlet 5x20
Q
4.8 Solder Connector
T
4.8 Solder Switch
S
2.5 Solder
LS
2.8 Solder
Q
4.8 Tab
W
6.3 Tab
S
2.5 Solder
LS
2.8 Solder
Q
4.8 Tab
W
6.3 Tab
27.9
28.1
46.9/47.1
R2.0 +0
-2.0
30.5
50.0 R3.0
20.7
DP illuminated switch is standard
10A 250Vac
Y
Panel thickness:
0.8 or 1.0 or 1.2
Call factory
for details
0717-1S State “Lit”
3b1a
4b2a
Switched Fused Inlet 5x20
Q
4.8 Solder Connector
T
4.8 Solder Switch
TERMINAL
S
2.5 Solder
LS
2.8 Solder
Q
4.8 Tab
W
6.3 Tab
10A 250Vac
R2.0 +0
-2.0
27.3
27.5
31.3/31.5
32.0
34.0
32.2
20.7
10A 250Vac
Y
Panel thickness:
0.8 or 1.0
or 1.2 or 1.5
Call factory
for details
0717-2-P For applications (eg medical equipment) where both live & neutral feeds must be fused
Double Fused Inlet 5x20
S
2.5 Solder
LS
2.8 Solder
Q
4.8 Tab
W
6.3 Tab
10A 250Vac
UL CSA 10A 250Vac UL 65°C
Terminal data shown at section end
For stock availability & additional options call the factory
To order:
State type number, connector terminal code, switch terminal code (if applicable),
and for snap-in items, the panel thickness. Stocked items are for 1.0mm panels
TYPE TERMINAL TERMINAL PANEL
(connector) (switch) thickness
0717-1S Q T 1.0mm
Factored
product
Factored
product
Factored
product
Factored
product
Factored
product
Factored
product
0717-2-P
(2k min order)
0717-2-C
(2k min order)
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
80
TERMINALTYPE DIMENSIONS(mm) View below is at Y
Technical data
Mouldings V2 (V0 option)
Connectors Tin plated solid brass
Terminals Silver plated
Ter minal dimensions For Connectors For Switches
Slide Slide Rocker
S N Q W P L LS V12 V16 T K T
2.5mm Solder 4mm Solder 4.8mm Solder/ 6.3 Fast on PCB Solder 2.8mm Solder 12-14 AWG 16 AWG Solder 2.8mm Solder 4.8mm Solder
Fast on Solid Wire Solid Wire
Note: Designated solder terminals should not be fitted with “Push on”,“QD”or “Fast on” type cable connectors
28.2
16.0
16.0
20A 125Vac
16A 250Vac
24.5
Ø3.5
32.6 42.0
R3
53.0
30.0
23.0
29.5
Ø3.5
37.6 45.0
R3
54.0
34.0
27.0
Y
Y
Y
Panel
thickness
0.8 - 1.3
2.5A 250Vac
20A 125Vac
16A 250Vac
24.519.5
12.5
7.5
Inlet
Inlet
Outlet
S
Solder
Q
4.8 Solder
W
6.3 Tab
Q
4.8 Solder
W
6.3 Tab
4.5
1.5x2.5 5.5
2.0x3.2 6.5
2.8x3.3 8.0
Ø1.7 5.5
1.7x3.0 10.0
1.5x3.0
1.35 0.8
2.6 6.0*
1.6
2.0 7.0*
1.3
8.5
3.5
R1.0
R0.8
Ø3.0x6.0
Factored
product
Factored
product
Factored
product
0723-C
(2k min order)
0722-C
(2k min order)
0721-P
(2k min order)
0721-P
(2k min order)
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
81
Fuseholders5 x 20 mm
BODY AND CAPTERMINAL
T
Solder
B
2.8 x 0.5
2.4 5.0
1.4
1.7 8.1
1.25
RA
RD
PANEL HOLE
12.0/
12.1
12.7
14.0
12.7
1.7/1.8
6.3A 250Vac (max fuse rating*) T-55 to T+70 (ambient)
Maximum dissipation wattage: 1.5W
UL 94V2 UL file E92075 CSA file LR44770
These products comply with safety category PC2
*Users should be aware of the de-rating factors published by specialist manufacturers of fuses
These fuseholders are fitted with combination (solder / 2.8) mid-body terminals
It has not been possible to show both views here
M520
Terminal Cover A0033 OO
In-line 5 x 20 fuseholder
Call factory for rating details
DIMENSIONS (mm)
Panel thickness 0.8-4.5mm
Panel thickness 0.8-4.5mm
Panel thickness 0.8-2.0mm
Panel thickness 0.8-4.5mm
23.0 9.0
5.0 16.0
23.0 9.0
5.0 16.0
30.0 2.0
5.0 16.0
30.0 2.05.0 16.0
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
TERMINAL BODY & CAP PANEL HOLE OPTIONS
T0332 RA ------
82
0332(T terminal shown)
0333(T terminal shown)
0340(T terminal shown)
0341(T terminal shown)
0332
Finger release
0333
Tool release
0340
Tool release
0341
Tool release
42.0 19.5
3.0
9.1
9.1 39.0
42.0 19.5
3.0
42.0 19.5
3.0
9.1
19.5
3.0
9.1 39.0
42.0
Fuseholders6 x 30 mm (114"x14")
BODY AND CAPTERMINAL
C
6.3 x 0.8
D
6.3 x 0.8
Right angle
T
4.8 x 0.8
Solder
U
4.8 x 0.8
Right angle solder
RA
Panel thickness
0.8 - 2.0mm for snap-in
0.8 - 4.5mm for nut fixing
RD
Panel thickness
0.8 - 2.0mm for snap-in
0.8 - 4.5mm for nut fixing
PANEL HOLE
16A 250Vac (max fuse rating*) T-55 to T+70 (ambient)
Maximum dissipation wattage: 2.5W
UL 94V2 UL file E92075 CSA file LR44770
These products comply with safety category PC2
*Users should be aware of the de-rating factors published by specialist manufacturers of fuses
Fuseholders with in-line termination have combination (4.8 / 6.3) terminals. It has not been
possible to show both views here. Units with right angle terminals have user specified end
terminals and combination mid-body terminals
M873
Cover for C & T terminals A0035 OO
In-line 6 x 30 11/4 x 1/4fuseholder
Call factory for rating details
DIMENSIONS (mm)
0345(C terminal shown)
0345(D terminal shown)
0347(C terminal shown)
0347(D terminal shown)
9.1
9.1
9.1
4.1
2.8
9.1
4.1
2.8 15.0
15.1
16.0/16.1
17.3
17.4
16.0/16.1
2.5
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
83
0345(C terminal shown)
0345(D terminal shown)
0347(T terminal shown)
0347(U terminal shown)
TERMINAL BODY & CAP PANEL HOLE OPTIONS
T0347 RA ------
Cat No. PAGE Cat No. PAGE Cat No. PAGE
0919 . . . . . . . . . . . . . . .41
0920 . . . . . . . . . . . . . . .41
0936 . . . . . . . . . . . . . . .47
0938 . . . . . . . . . . . . . . .47
992B . . . . . . . . . . . . . .17,73
1041 . . . . . . . . . . . . . . .67
1045 . . . . . . . . . . . . . . .67
1047 . . . . . . . . . . . . . . .76
1048 . . . . . . . . . . . . . . .76,77
1050 . . . . . . . . . . . . . . .76,77
1067 . . . . . . . . . . . . . . .25
1080 . . . . . . . . . . . . . . .61,63,65
1090 . . . . . . . . . . . . . . .78
1091 . . . . . . . . . . . . . . .78
1100 . . . . . . . . . . . . . . .40
1101 . . . . . . . . . . . . . . .40
1250 . . . . . . . . . . . . . . .15
1300 . . . . . . . . . . . . . . .20
13 112 . . . . . . . . . . . . .16,17
13 208 . . . . . . . . . . . . .16
13 211 . . . . . . . . . . . . .17
1350 . . . . . . . . . . . . . . .26
1353 . . . . . . . . . . . . . . .26
1484 . . . . . . . . . . . . . . .26
1487 . . . . . . . . . . . . . . .26
1500 . . . . . . . . . . . . . . .20
1500 Twin units . . . . . .28
1501 . . . . . . . . . . . . . . .20
1502 . . . . . . . . . . . . . . .20
1510 . . . . . . . . . . . . . . .20,28
1511 . . . . . . . . . . . . . . .20
1520 . . . . . . . . . . . . . . .20,28
1521 . . . . . . . . . . . . . . .20
1522 . . . . . . . . . . . . . . .20
1550 . . . . . . . . . . . . . . .26
1551 . . . . . . . . . . . . . . .26
1552 . . . . . . . . . . . . . . .26
1553 . . . . . . . . . . . . . . .26
1560 . . . . . . . . . . . . . . .26
1561 . . . . . . . . . . . . . . .26
1562 . . . . . . . . . . . . . . .26
1570 . . . . . . . . . . . . . . .26
1571 . . . . . . . . . . . . . . .26
1572 . . . . . . . . . . . . . . .26
1700 . . . . . . . . . . . . . . .64
1710 . . . . . . . . . . . . . . .64
1710 Guard . . . . . . . . .63
1720 . . . . . . . . . . . . . . .64
1721 . . . . . . . . . . . . . . .64
1722 . . . . . . . . . . . . . . .64
1750 . . . . . . . . . . . . . . .64
1760 . . . . . . . . . . . . . . .64
1770 . . . . . . . . . . . . . . .64
1911 . . . . . . . . . . . . . . .43
1961 . . . . . . . . . . . . . . .43
22-- . . . . . . . . . . . . . . .30-33
23-- . . . . . . . . . . . . . . .30-33
24-- . . . . . . . . . . . . . . .30-31
25-- . . . . . . . . . . . . . . .30-31
2760 . . . . . . . . . . . . . . .69
2820 . . . . . . . . . . . . . . .70
2821 . . . . . . . . . . . . . . .70
2870 . . . . . . . . . . . . . . .70
290-- Snap action . . . .48
2950 . . . . . . . . . . . . . . .67
2951 . . . . . . . . . . . . . . .68
3005 . . . . . . . . . . . . . . .55
3006 . . . . . . . . . . . . . . .55
3101 . . . . . . . . . . . . . . .56
3102 . . . . . . . . . . . . . . .56
3111 . . . . . . . . . . . . . . .56
3130 . . . . . . . . . . . . . . .74
3141 . . . . . . . . . . . . . . .57
3145 . . . . . . . . . . . . . . .57
3146 . . . . . . . . . . . . . . .57
3147 . . . . . . . . . . . . . . .57
3160 . . . . . . . . . . . . . . .74
3161 . . . . . . . . . . . . . . .74
3221 . . . . . . . . . . . . . . .74
340- Snap action . . . . .50
390- Snap action . . . . .50
3900 Series . . . . . . . . .62
3950 Series . . . . . . . . .62
4102 . . . . . . . . . . . . . . .46
5500 . . . . . . . . . . . . . . .22
5500 Twin units . . . . . .23
0005 . . . . . . . . . . . . . . .61,65
0023 . . . . . . . . . . . . . . .78
0024 . . . . . . . . . . . . . . .78
0033 . . . . . . . . . . . . . . .82
0035 . . . . . . . . . . . . . . .83
0042 . . . . . . . . . . . . . . .23,25,27,29
0046 . . . . . . . . . . . . . . .19,21,23
0055 . . . . . . . . . . . . . . .54
0056 . . . . . . . . . . . . . . .54
0061 . . . . . . . . . . . . . . .75
0062 . . . . . . . . . . . . . . .75
0063 . . . . . . . . . . . . . . .75
0067 Lampholder . . . . .75
0067 Neon . . . . . . . . . .71
0081 . . . . . . . . . . . . . . .70
0092 . . . . . . . . . . . . . . .61,65
0095 . . . . . . . . . . . . . . .75
0145 . . . . . . . . . . . . . . .67
0167 Cover . . . . . . . . .11,13,14,35
0177 . . . . . . . . . . . . . . .71
0180 Neon . . . . . . . . . .71
0180 Cover . . . . . . . . .13,14
0188 Cover . . . . . . . . .16,17
0195 . . . . . . . . . . . . . . .67,72
0196 . . . . . . . . . . . . . . .72
0232 . . . . . . . . . . . . . . .63,65
0233 . . . . . . . . . . . . . . .72
0234 . . . . . . . . . . . . . . .72
0245 . . . . . . . . . . . . . . .67
0273 . . . . . . . . . . . . . . .68,69
0275 . . . . . . . . . . . . . . .69
0276 . . . . . . . . . . . . . . .69
0277 . . . . . . . . . . . . . . .69
0278 . . . . . . . . . . . . . . .68
0279 . . . . . . . . . . . . . . .61,65
0305 . . . . . . . . . . . . . . .53
0306 . . . . . . . . . . . . . . .53
0307 . . . . . . . . . . . . . . .53
0308 . . . . . . . . . . . . . . .53
0320 . . . . . . . . . . . . . . .52
0323 . . . . . . . . . . . . . . .42
0327 . . . . . . . . . . . . . . .47
0331 . . . . . . . . . . . . . . .61,65
0332 . . . . . . . . . . . . . . .82
0333 . . . . . . . . . . . . . . .82
0340 . . . . . . . . . . . . . . .82
0341 . . . . . . . . . . . . . . .82
0345 . . . . . . . . . . . . . . .83
0347 . . . . . . . . . . . . . . .83
0413 . . . . . . . . . . . . . . .78
0430 . . . . . . . . . . . . . . .20,73
0430 Twin units . . . . . .28
0434 . . . . . . . . . . . . . . .21,23
0441 . . . . . . . . . . . . . . .27
0445 . . . . . . . . . . . . . . .78
0480 . . . . . . . . . . . . . . .26,73
0494 . . . . . . . . . . . . . . .23,27,29
0506 . . . . . . . . . . . . . . .61,65
0520 . . . . . . . . . . . . . . .82
0539 . . . . . . . . . . . . . . .61,63,65
0568 . . . . . . . . . . . . . . .68
0569 . . . . . . . . . . . . . . .68
0579 . . . . . . . . . . . . . . .71
0581 . . . . . . . . . . . . . . .72
0582 . . . . . . . . . . . . . . .72
0586 . . . . . . . . . . . . . . .70
0589 . . . . . . . . . . . . . . .70
0600 . . . . . . . . . . . . . . .61
0602 . . . . . . . . . . . . . . .61
0616 . . . . . . . . . . . . . . .27
0707 . . . . . . . . . . . . . . .79
0708 . . . . . . . . . . . . . . .79
0709 . . . . . . . . . . . . . . .79
0710 . . . . . . . . . . . . . . .79
0711 . . . . . . . . . . . . . . .79
0717 . . . . . . . . . . . . . . .80
0721 . . . . . . . . . . . . . . .81
0722 . . . . . . . . . . . . . . .81
0723 . . . . . . . . . . . . . . .81
0873 . . . . . . . . . . . . . . .83
0910 . . . . . . . . . . . . . . .42
0911 . . . . . . . . . . . . . . .42,45
0911 Vandal . . . . . . . . .42,45
0916 . . . . . . . . . . . . . . .41
0917 . . . . . . . . . . . . . . .41
0918 . . . . . . . . . . . . . . .41
5503 . . . . . . . . . . . . . . .22
5508 . . . . . . . . . . . . . . .22
6000 . . . . . . . . . . . . . . .18
6000 Twin units . . . . . .25
6001 . . . . . . . . . . . . . . .18
6002 . . . . . . . . . . . . . . .18
6003 . . . . . . . . . . . . . . .18
6008 . . . . . . . . . . . . . . .18
6009 . . . . . . . . . . . . . . .18
6010 . . . . . . . . . . . . . . .18
6011 . . . . . . . . . . . . . . .18
6030 . . . . . . . . . . . . . . .18,73
6050 . . . . . . . . . . . . . . .24
6051 . . . . . . . . . . . . . . .24
6052 . . . . . . . . . . . . . . .24
6053 . . . . . . . . . . . . . . .24
6054 . . . . . . . . . . . . . . .24
6055 . . . . . . . . . . . . . . .24
6056 . . . . . . . . . . . . . . .24
6057 . . . . . . . . . . . . . . .24
6058 . . . . . . . . . . . . . . .24
6059 . . . . . . . . . . . . . . .24
6060 . . . . . . . . . . . . . . .24
6061 . . . . . . . . . . . . . . .24
6062 . . . . . . . . . . . . . . .24
6066 . . . . . . . . . . . . . . .24
6067 . . . . . . . . . . . . . . .24
6068 . . . . . . . . . . . . . . .24
6090 . . . . . . . . . . . . . . .24
6091 . . . . . . . . . . . . . . .24
6092 . . . . . . . . . . . . . . .24
7000 . . . . . . . . . . . . . . .38
7001 . . . . . . . . . . . . . . .38
7003 . . . . . . . . . . . . . . .38
7004 . . . . . . . . . . . . . . .38
7030 . . . . . . . . . . . . . . .38,73
7050 . . . . . . . . . . . . . . .38
7051 . . . . . . . . . . . . . . .38
7053 . . . . . . . . . . . . . . .38
7054 . . . . . . . . . . . . . . .38
8200 . . . . . . . . . . . . . . .36
8201 . . . . . . . . . . . . . . .36
8250 . . . . . . . . . . . . . . .36
8251 . . . . . . . . . . . . . . .36
8300 . . . . . . . . . . . . . . .34
8300 Vandal . . . . . . . . .44
8301 . . . . . . . . . . . . . . .34
8301 Vandal . . . . . . . . .44
8303 . . . . . . . . . . . . . . .34
8304 . . . . . . . . . . . . . . .34
8350 . . . . . . . . . . . . . . .34
8350 Vandal . . . . . . . . .44
8351 . . . . . . . . . . . . . . .34
8351 Vandal . . . . . . . . .44
8353 . . . . . . . . . . . . . . .34
8354 . . . . . . . . . . . . . . .34
8500 . . . . . . . . . . . . . . .10
8500 Push . . . . . . . . . .35
8503 . . . . . . . . . . . . . . .10
8550 . . . . . . . . . . . . . . .10
8550 Semi Rotary . . . . .11
8553 . . . . . . . . . . . . . . .10
8580 . . . . . . . . . . . . . . .10,73
8600 . . . . . . . . . . . . . . .12
8601 . . . . . . . . . . . . . . .12
8602 . . . . . . . . . . . . . . .12
8610 . . . . . . . . . . . . . . .12
8611 . . . . . . . . . . . . . . .12
8620 . . . . . . . . . . . . . . .14
8630 . . . . . . . . . . . . . . .12,73
8634 . . . . . . . . . . . . . . .13
8650 . . . . . . . . . . . . . . .12
8651 . . . . . . . . . . . . . . .12
8652 . . . . . . . . . . . . . . .12
8653 . . . . . . . . . . . . . . .12
8660 . . . . . . . . . . . . . . .12
8661 . . . . . . . . . . . . . . .12
8670 . . . . . . . . . . . . . . .14
8800 . . . . . . . . . . . . . . .8
8800 Twin units . . . . . .8
8801 . . . . . . . . . . . . . . .8
8802 . . . . . . . . . . . . . . .8
9000 . . . . . . . . . . . . . . .60
9100 . . . . . . . . . . . . . . .58
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
Index
84
For the purposes of the following Conditions of Sale, the words “The Company” refer to Arcolectric Switches plc.
CATALOGUES Catalogues, price lists and other advertising matter are an indication of the type of goods offered
and no prices or other particulars contained therein shall be binding.
PRICES Quotations are open for acceptance within 30 days. Prices on orders issued within that period are
guaranteed firm for three months from the date of formal acknowledgement. Deliveries extending beyond the
initial six months will be invoiced at the prices shown in the Company's then current price list.
Notwithstanding any clauses attached to Customers' orders, the Company's formal acceptance of the order is
made on the understanding that this clause applies and is accepted by the Customer unless expressly waived,
in writing, by the Company.
PAYMENT Unless otherwise agreed in writing, payment in full is due immediately in respect of any goods deliv-
ered. Until payment is made in full, the goods shall remain the property of the Company, but the risk therein and
all liability to third parties in respect thereof shall pass to the customer on delivery.
SETTLEMENT Credit terms can be arranged for customers taking regular deliveries of goods, such payment
terms are 30 days from date of invoice, or such other terms as agreed and are strictly nett. For infrequent pur-
chases and/or low value orders payment against a pro-forma invoice is required.
No discount is allowed for early payment or payment against a pro-forma invoice. Failure to pay in accordance
with these terms will result in the Company instructing a third party to obtain settlement. Any costs incurred thereby
will be charged to the Customer. The Company reserves the right to charge interest on overdue debts at a rate
of 4% above HSBC Bank base rate.
DESPATCH Any times quoted for despatch are to be treated as estimates only and the Company shall not be
liable for failure to despatch within such time. In all cases, whether a time for despatch be quoted or not, the
time for despatch shall be extended by a reasonable period if delay in despatch is caused by instructions or lack
of instructions from the Customer or by industrial dispute, or by any cause whatsoever beyond the reasonable
control of the Company.
MINIMUM ORDER QUANTITY Please discuss your likely batch quantity requirements with our Sales
department prior to ordering. On some items, ie coloured switches or special printing, MOQ's of 1000 or more
may apply.
CARRIAGE The Company reserves the right to make nominal charges for handling, packaging and carriage on
all orders.
DAMAGE OR LOSS IN TRANSIT If the Customer wishes the Company to make a claim on the carriers for a
parcel damaged in transit, the Customer must notify the carriers and the Company within 3 working days of
receipt. If a consignment fails to arrive within ten working days of the Customers' receipt of an advice note and
invoice from the Company, the Customer should immediately notify the carrier and the Company. Claims can
only be considered if made within this period. Shortage claims on consignments not damaged in transit should
be made within seven working days.
REJECTION Unless otherwise agreed, goods rejected by the Customer as not complying with the contract
must be advised within 7 working days of receipt.
DEFECTS AFTER DELIVERY The Company will make good by repair, or at the Company's option, by the supply
of a replacement, defects which under proper use, appear in the goods within a period of twelve calendar
months after the goods have been delivered, and arise solely from faulty design, workmanship or materials,
always provided that the defective parts have been returned to the Company if it be so required.
The liability of the Company under this clause shall be in lieu of any warranty or condition implied by the law as
to the quality or fitness for any particular purpose of the goods, and save as provided in this clause the
Company shall not be under any liability, whether in contract, tort or otherwise, in respect of defects in goods
delivered or for any injury (other than personal injury caused by the Company’s negligence as defined in Section
1 of the Unfair Contract Terms Act 1977), damage or loss resulting from such defect or from any work done in
connection therewith. Provided however, that nothing in this clause shall operate to exclude any warranty or
condition implied by law as to the quality of the goods in the event that the goods when sold by the Customer or
when sold by any person or persons to whom the Customer may sell the goods shall become the subject of a
consumer sale as defined in the Supply of Goods (Implied Terms) Act 1973, except to the extent that any claim
under such warranty or condition shall have arisen from any act or omission by the Customer or by any other
person or persons selling the goods by way of a consumer sale.
UK HEALTH AND SAFETY ACT 1974 Detailed approval information is available on application. Approvals do
not always cover every version of a component. Switches with metal levers (or metal fixing systems) do not
comply with the latest standards on safety unless the fixing plate is reliably earthed. Product descriptions are, of
necessity, abridged and users should always give full details of electrical load and environmental conditions so
that a check can be made that the component is suitable for the application. Switch ratings are, unless otherwise
stated, resistive at 250 Vac, T55. Transparent lenses on signal lamps, neon indicators and lit switches are
moulded in polycarbonate, a material which is attacked by hydrocarbons.
ARBITRATION If at any time any question, dispute or difference whatsoever shall arise between the Customer
and the Company in relation to or in connection with the contract, either party may give to the other party notice
in writing of the existence of such question, dispute or difference and the same shall be referred to the arbitration
of a third party to be mutually agreed upon, or failing agreement within 14 days of receipt of such notice, a party
appointed by the president, at the time, of the UK organisation known as the Federation of British Electrotechnical
and Allied Manufacturers’ Associations. Any legal recourse requiring judiciary judgement shall take place through
the courts and country of the Company’s choice.
LEGAL CONSTRUCTION Unless otherwise agreed in writing, the contract shall in all aspects be construed and
operate as an English contract and in conformity with English law.
STATUTORY AND OTHER REGULATIONS If the cost to the Company of performing its obligations under the
contract, be increased or reduced by reason of the making or amendment after the date of tender of any law or
of any order, regulation, or bye-law having the force of law that shall affect the performance of the Company’s
obligations under the contract, the amount of such increase or reduction shall be added to or deducted from the
contract price as the case may be.
OVER RUNS Where products are manufactured as special for a Customer, for instance colour, marking or
circuit, the Company reserves the right to despatch up to a maximum of 5% excess at the end of the order or at
the completion of the schedule.
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
Conditions of sale
arcolectric
Arcolectric Switches plc,
Central Avenue,
West Molesey, Surrey
England KT8 2RF
tel: +44 (0)20 8979 3232
fax: +44 (0)20 8979 2565
info@arcoswitch.co.uk
www.arcolectric.co.uk
UK Stockists
Arrow Catalogue
Essex
t: 01279 626777 f: 01279 441687
e: sales@arrowuk.com
Farnell Electronic Components Ltd
Yorkshire
t: 0870 1200 200 f: 0870 1200 201
e: sales@farnell.com
E Preston Electrical Ltd
Cheshire
t: 0161 339 5177 f: 0161 343 1935
e: sales@epreston.co.uk
R S Components
Northants
t: 01536 201201 f: 01536 201501
e: general@rswww.com
SINGAPORE - Singapore
Hitachi High-Technologies (S) Pte Ltd
e: bernard-tan@hitachi-hitec.com.sg
t: +65 6733 2787 f: +65 6737 8187
SINGAPORE - Singapore
Jelco Private Limited (Stockist)
e: jelco@cyberway.com.sg
t: +65 6561 1988 f: +65 6567 6242
SLOVAKIA - Skalica
Amicus sk.spol.sr.o
e: amicus@ba.psg.sk
t: +421 801 664 8644 f: +421 801 664 8530
SLOVENIA - Postojna
Ventes d.o.o.
e: ventes@siol.net
t: +386 1 709 7250 f: +386 1 709 7251
SOUTH AFRICA - Johannesburg
O & C Alexander Sales (Pty) Limited
e: ocalex@mweb.co.za
t: +27 11 403 3332 f: +27 11 403 1026
SPAIN - Barcelona
Ermec
e: ermec@ermec.com
t: +34 93 450 1600 f: +34 93 433 0885
SWEDEN - Tranas
OEM Component AB
e: info@comp.oem.se
t: +46 140 360 600 f: +46 140 360 699
SWITZERLAND - Lausanne
Orlamp SA
e: info@orlamp.ch
t: +41 21 323 1434 f: +41 21 323 4214
TAIWAN - Taipei
Inalways Corporation
e: inalways@mail.inalways.com.tw
t: +886 22 299 6370 f: +886 22 299 7053
THAILAND - Bangkok
Vutipong Electronic Co. Ltd
e: vutipong5@hotmail.com
t: +662 226 6496-9 f: +662 623 8617
TURKEY - Izmir
Metot Sanayi Ve Ticaret Limited Sti
e: metot@superonline.com
t: +90 232 252 4824 f: +90 232 252 4825
USA - Los Angeles
Arcolectric Corporation
e: info@arcolectric.com
t: +1 818 700 1933 f: +1 818 700 9541
Arcolectric Agents
ARGENTINA - Buenos Aires
Cristina Rogers
e: crisrogers@fibertel.com.ar
t: +54 11 4797 5480 f: +54 11 4797 5480
AUSTRALIA - Sydney
Beal Pritchett Pty Limited
e: BealPritchett@bigpond.com
t: +612 9437 6124 f: +612 9438 3379
AUSTRIA - Hörsching
Höllinger Industrie Vertrieb
e: gerhard.hoellinger@aon.at
t: +43 7221 74622 f: +43 7221 74622 21
BELGIUM - Brussels
Sprl Usitec Bvba
e: usitec@skynet.be
t: +32 2 343 70 52 f: +32 2 343 53 34
CANADA
Arcolectric Corporation (Los Angeles)
e: info@arcolectric.com
t: +1 818 700 1933 f: +1 818 700 9541
CHINA (Northern) - Qingdao
Widline Industrial Supply Co. Ltd
e: landw@public.qd.sd.cn
t: +86 532 607 1971/1981 f: +86 532 607 1991
CYPRUS - Nicosia
Solmatic Ltd
e: SOLMATIC@cytanet.com.cy
t: +357 249 7907 f: +357 231 4844
CZECH REPUBLIC - Prague
Ampra CZ s.r.o.
e: ampracz@ampra.cz
t: +420 2 8393 1122/2244 f: +420 2 8393 3344
DENMARK - Hvidovre
Chemo Electric A/S
e: info@chemolec.dk
t: +45 36 77 30 44 f: +45 36 77 30 88
FINLAND - Turku
OEM Automatic OY
e: jouni.joutsio@fi.oem.se
t: +358 2 4120 400 f: +358 2 4120 496
FRANCE - Champs sur Marne
B.R.N. Composants
e: brn.composants@libertysurf.fr
t: +33 1 45 16 12 32 f: +33 1 45 16 12 38
GERMANY - Fulda
Maluska Elektronik GmbH
e: info@maluska.de
t: +49 661 9475-0 f: +49 661 9475-30
GREECE - Athens
Extant Limited
e: interep@otenet.gr
t: +30 210 861 6334 f: +30 210 861 7622
HUNGARY - Budapest
Lomex KFT
e: info@lomex.hu
t: +361 349 5906 f: +361 320 3292
INDIA - Mumbai
Importex
e: importex@vsnl.net
t: +91 22 2361 2592 f: +91 22 2361 5097
REPUBLIC OF IRELAND - Dublin
Flynn Equipment Limited
e: flynn.equipment@indigo.ie
t: +353 1289 8727 f: +353 1289 8726
ISRAEL - Tel Aviv
A.S.R. (Avi Sasson Representatives)
e: asr@isdn.net.il
t: +97 2350 15322 f: +97 2350 31986
ITALY - Milan
Fusit Srl
e: fusit@fusit.it
t: +3902 26 68 00 53 f: +3902 26 68 02 97
KOREA - Seoul
electroCOM
e: electrocom@empal.com
t: +82 2473 0840-2 f: +82 2486 1609
MEXICO
Arcolectric Corporation (Los Angeles)
e: info@arcolectric.com
t: +1 818 700 1933 f: +1 818 700 9541
NETHERLANDS - Achterveld
Calpe BV
e: info@calpe.nl
t: +31 342 45 15 44 f: +31 342 45 13 64
NORWAY - Drammen
OEM Automatic A/S
e: info@no.oem.se
t: +47 3289 7270 f: +47 3289 7280
PHILIPPINES - Makati City
Pylon International Trading Corporation
e: pylontrading@yahoo.com
t: +632 892 8458 f: +632 812 8703
POLAND - Warsaw
Elemco Jacek Piskorski
e: elemco@medianet.pl
t: +48 22 877 3773 f: +48 22 877 3773
PORTUGAL - Cascais
Hotelec Equipamentos Electricos Lda
e: hotelec@netcabo.pt
t: +351 214 832 681 f: +351 214 831 550
ROMANIA - Bucharest
LS Electronic Components
e: constantin.savu@ecas.ro
t: +40 21 230 2550 f: +40 21 231 2173
RUSSIA - St Petersburg
ElectroMir
e: erk@electromir.com
t: +7 812 320 6488 f: +7 812 320 6490