AC-DC High Peak Power Rating 100-240 Watts THE XPERTS IN POWER CPE Series High Peak Power Rating * * Adjustable Output Voltage * 240 Watts Convection Cooled * Optional Screw Terminals * Optional Remote ON/OFF * International Safety Approvals Specification Input Remote ON/OFF Input Voltage * Input Frequency Power Factor Inrush Current * * * 85-264 VAC (120-370 VDC) For optional 50-264 VAC operation with a duty cycle of 1s/30s add suffix "-U" to model numbers. Output power derates by 25% 47-63 Hz Meets EN61000-3-2 15/30 A typical at 100/200 VAC Output Output Voltage * * Optional, add suffix "-R" to model number ON 4.5 V to 12.5 between RC+ & RCOFF 0 V to 0.5 V between RC+ & RC- Efficiency Leakage Current * * Isolation * Covers * 81-87% depending on output voltage 0.75 mA max for 0.1 mA max add suffix "-G" to model number Input to ground 2000 VAC 1 min, Input to output 3000 VAC 1 min Available by adding suffix "-C" to model number For optional screw terminal connections add suffix "-T" to model number General Line Regulation Load Regulation Ripple & Noise Start up time * * * * Hold up Time Output Voltage Set Point Output Voltage Adjustment Overcurrent Protection Overvoltage Protection * * See Table 2 additional outputs can be achieved by the addition of a DC/DC converter to the psu board add suffix "-Z" to model numbers. Contact technical sales for details 48 mV max from low line to high line 0.3% max from 0-100% load 150 mV typical 20 MHz bandwidth 500 ms max at 100 VAC and 100% load 20 ms typical 100 VAC, 100% load 4% max Shock * 10% min (See Table) 101% of peak current auto recovery * 115-140% of rating Safety Approvals * EMC * Screw Terminals Environmental Operating Temperature Storage Temperature Relative Humidity Vibration * * * * * -10C to +70C see derating curves -20 C to +75 C 20-90% RH non-condensing 10-55 Hz, 2 G, 3 mins period each along X, Y & Z axis 20 G, 11 ms, once each X, Y & Z axis EMC and Safety UL60950, EN60950, EN50178 C-UL (CSA 60950) Conducted emissions EN55022-B, CISPR22-B (not available with low leakage option"-G") complies with EN61000-4 -2, -3, -4, -5, -6, -8, -11. * * www.xpplc.com sales@xpplc.com Output Voltage 24.0 V (21.4-26.4) 36.0 V (26.4-39.6) 48.0 V (39.6-52.8) 24.0 V (21.4-26.4) 36.0 V (26.4-39.6) 48.0 V (39.6-52.8) 24.0 V (21.4-26.4) 36.0 V (26.4-39.6) 48.0 V (39.6-52.8) CPE Output Current Max 4.2 A 2.8 A 2.1 A 6.3 A 4.2 A 3.2 A 10.0 A 6.7 A 5.0 A Regulation Peak 7.0 A 4.7 A 3.5 A 12.0 A 8.0 A 6.0 A 20.0 A 13.4 A 10.0 A Line 48 mV 48 mV 48 mV 48 mV 48 mV 48 mV 48 mV 48 mV 48 mV Load 76 mV 90 mV 150 mV 76 mV 90 mV 150 mV 76 mV 90 mV 150 mV Efficiency (200 VAC, 100% load) 84% 85% 85% 85% 86% 87% 86% 87% 87% Model Number CPE100PS24 CPE100PS36 CPE100PS48 CPE150PS24 CPE150PS36 CPE150PS48 CPE240PS24 CPE240PS36 CPE240PS48 AC-DC Power Supplies OUTPUT VOLTAGE & CURRENT RATINGS CPE 100 Watts "-C" Option Connector CN1 VH5-5N CN2 VHR-8N CN3 (Option) CN4 Max Component Height - 35mm Weight - 380g Mating Connector (Option) XHP-2 XHP-3 Terminal Chain: SVH-21T-P1.1 Loose: BVH-21T-P1.1 Chain: SVH-21T-P1.1 Loose: BVH-21T-P1.1 Chain: SXH-001T-P0.6 Loose: BXH-001T-P0.6 Chain: SXH-001T-P0.6 Loose: BXH-001T-P0.6 CN1 Pin No. 1 2 3 4 5 CPE 150 Watts Input AC(L) AC(N) FG CN2 Pin No. Output 1, 2, 3, 4 -V 5, 6, 7, 8 +V "-C" Option CN3 (Optional) Pin No. Remote ON/OFF 1 RC (+) 2 RC (-) CN4 (Optional) Pin No. 1 2 3 Max Component Height - 40mm Weight - 490g -Z + COM - CPE 240 Watts "-C" Option Max Component Height - 45mm Weight - 690g www.xpplc.com NOTES: 1. Tolerance: 1. 2. Dimensions in mm. 3. PCB Material: CEM3. 4. Mounting torque: 1.5 Nm (16kgf cm) max. 5. Optional mating connector and loom kits are available order as: CPE CON KIT CPE LOOM KIT (one kit fits all models). sales@xpplc.com AC-DC High Peak Power Rating 100-240 Watts CPE Series Pin Connections CPE 100 Watts Open Frame Cover Fitted CPE 150 Watts Open Frame Cover Fitted CPE 240 Watts Open Frame Cover Fitted Output ripple & noise may increase to 350 mV pk-pk max. Mounting Orientation www.xpplc.com sales@xpplc.com 3 conditions must be satisfied: Ip 1. t1 10 sec 2. Iave = Ip t1 + Io t2 rated current t1 + t2 3. Duty cycle i.e. I ave t1 x 100 35% for CPE100 t1 + t2 Io For CPE150 & CPE240, the duty is dependant on peak load, refer to graphs. AC-DC Power Supplies Peak Load Ip = peak current Iave = average current Io = output current Peak Wattage (W) CPE 240 Remote ON/OFF Optional Remote ON/OFF. (add suffix "-R") Voltage Applied Between RC (+) and RC (-) SW ON (4.5 - 12.5 V) SW OFF (0-0.5 V) Output ON OFF AC/DC High Peak Power Rating 100-240 Watts CPE Series Peak Wattage (W) CPE 150 If external voltage source is in the range of 4.5 - 12.5 V, current limit resistor R is not required. If external voltage source exceeds 12.5 V, current limit resistor R must be connected in series To calculate the current limit resistor use following equation: Vcc - (1.1 +R x 0.005) R() = 0.005 Where; Vcc = Ri = External Voltage Source The internal resistance (780) www.xpplc.com sales@xpplc.com Rev 1.0