High Peak Power Rating
Adjustable Output Voltage
240 Watts Convection Cooled
Optional Screw Terminals
Optional Remote ON/OFF
International Safety Approvals
Input
Input Voltage 85-264 VAC (120-370 VDC)
For optional 50-264 VAC operation
with a duty cycle of 1s/30s add suffix
“-U” to model numbers. Output power
derates by 25%
Input Frequency 47-63 Hz
Power Factor Meets EN61000-3-2
Inrush Current 15/30 A typical at 100/200 VAC
Output
Output Voltage See Table
2 additional outputs can be achieved
by the addition of a DC/DC converter
to the psu board add suffix “-Z” to
model numbers.
Contact technical sales for details
Line Regulation 48 mV max from low line to high line
Load Regulation ±0.3% max from 0-100% load
Ripple & Noise 150 mV typical 20 MHz bandwidth
Start up time 500 ms max at 100 VAC and
100% load
Hold up Time 20 ms typical 100 VAC, 100% load
Output Voltage ±4% max
Set Point
Output Voltage ±10% min
Adjustment (See Table)
Overcurrent 101% of peak current auto recovery
Protection
Overvoltage 115-140% of rating
Protection
Remote ON/OFF Optional, add suffix “-R”
to model number
ON 4.5 V to 12.5 between RC+ & RC-
OFF 0 V to 0.5 V between RC+ & RC-
General
Efficiency 81-87% depending on output voltage
Leakage Current 0.75 mA max
for 0.1 mA max add suffix “-G”
to model number
Isolation Input to ground 2000 VAC 1 min,
Input to output 3000 VAC 1 min
Covers Available by adding suffix “-C”
to model number
Screw Terminals For optional screw terminal
connections add suffix “-T”
to model number
Environmental
Operating -10°C to +70°C
Temperature see derating curves
Storage -20 °C to +75 °C
Temperature
Relative Humidity 20-90% RH non-condensing
Vibration 10-55 Hz, 2 G, 3 mins period each
along X, Y & Z axis
Shock 20 G, 11 ms, once each X, Y & Z axis
EMC and Safety
Safety Approvals UL60950, EN60950, EN50178
C-UL (CSA 60950)
EMC Conducted emissions EN55022-B,
CISPR22-B (not available with low
leakage option“-G”) complies with
EN61000-4 -2, -3, -4, -5, -6, -8, -11.
100-240 Watts
CPE Series
AC-DC High Peak Power Rating
Specification
THE XPERTS INPOWER
www.xpplc.com sales@xpplc.com
Output Output Current Regulation Efficiency Model
Voltage Max Peak Line Load (200 VAC, 100% load) Number
24.0 V (21.4-26.4) 4.2 A 7.0 A 48 mV 76 mV 84% CPE100PS24
36.0 V (26.4-39.6) 2.8 A 4.7 A 48 mV 90 mV 85% CPE100PS36
48.0 V (39.6-52.8) 2.1 A 3.5 A 48 mV 150 mV 85% CPE100PS48
24.0 V (21.4-26.4) 6.3 A 12.0 A 48 mV 76 mV 85% CPE150PS24
36.0 V (26.4-39.6) 4.2 A 8.0 A 48 mV 90 mV 86% CPE150PS36
48.0 V (39.6-52.8) 3.2 A 6.0 A 48 mV 150 mV 87% CPE150PS48
24.0 V (21.4-26.4) 10.0 A 20.0 A 48 mV 76 mV 86% CPE240PS24
36.0 V (26.4-39.6) 6.7 A 13.4 A 48 mV 90 mV 87% CPE240PS36
48.0 V (39.6-52.8) 5.0 A 10.0 A 48 mV 150 mV 87% CPE240PS48
CPE 100 Watts
www.xpplc.com sales@xpplc.com
AC-DC Power Supplies AC-DC High Peak Power Rating 100-240 Watts CPE Series
OUTPUT VOLTAGE & CURRENT RATINGS CPE
Connector Mating Terminal
Connector
CN1 VH5-5N Chain: SVH-21T-P1.1
Loose: BVH-21T-P1.1
CN2 VHR-8N Chain: SVH-21T-P1.1
Loose: BVH-21T-P1.1
CN3 XHP-2 Chain: SXH-001T-P0.6
(Option) Loose: BXH-001T-P0.6
CN4 XHP-3 Chain: SXH-001T-P0.6
(Option) Loose: BXH-001T-P0.6
Pin No. Input
1 AC(L)
2
3 AC(N)
4
5FG
CN1
Pin No. Output
1, 2, 3, 4 -V
5, 6, 7, 8 +V
CN2
Pin Connections
Pin No. Remote ON/OFF
1 RC (+)
2 RC (-)
CN3 (Optional)
Pin No. -Z
1+
2 COM
3-
CN4 (Optional)
NOTES:
1. Tolerance: ±1.
2. Dimensions in mm.
3. PCB Material: CEM3.
4. Mounting torque: 1.5 Nm
(16kgf cm) max.
5. Optional mating connector
and loom kits are available order as:
CPE CON KIT
CPE LOOM KIT
(one kit fits all models).
Max Component Height - 35mm
Weight - 380g
Max Component Height - 40mm
Weight - 490g
Max Component Height - 45mm
Weight - 690g
CPE 150 Watts
CPE 240 Watts
“-C” Option
“-C” Option
“-C” Option
www.xpplc.com sales@xpplc.com
Cover Fitted
Open Frame
Open Frame
Open Frame
Cover Fitted
Cover Fitted
CPE 240 Watts
CPE 150 Watts
CPE 100 Watts
Mounting Orientation
Output ripple & noise may increase to 350 mV pk-pk max.
www.xpplc.com sales@xpplc.com
AC-DC Power Supplies AC/DC High Peak Power Rating 100-240 Watts CPE Series
3 conditions must be satisfied:
1. t1 10 sec
2. Iave = Ip t1 + Io t2 rated current
t1 + t2
3. Duty cycle i.e. t1 x 100 35% for CPE100
t1 + t2
For CPE150 & CPE240, the duty is dependant on
peak load, refer to graphs.
Ip
I ave
Io
Ip = peak current Iave = average current Io = output current
Peak Wattage (W)
CPE 150
Peak Wattage (W)
CPE 240
Peak Load
Optional Remote ON/OFF. (add suffix “-R”)
Remote ON/OFF
Voltage Applied Between Output
RC (+) and RC (-)
SW ON ON
(4.5 - 12.5 V)
SW OFF OFF
(0-0.5 V)
If external voltage source is in the range of 4.5 - 12.5 V, current limit resistor R is not
required. If external voltage source exceeds 12.5 V, current limit resistor R must be
connected in series
To calculate the current limit resistor use following equation:
R() =
Where;
Vcc = External Voltage Source
Ri = The internal resistance (780)
Vcc - (1.1 +R x 0.005)
0.005
Rev 1.0