SCDS SERIES RELIABILITY TEST
1-1 MECHANICAL PERFORMANCE
NO. ITEM SPECIFICATION TEST CONDITIONS
1-1-1 Vibration Appearance : No Damage Test device shall be soldered on the substrate.
L Change : within r10% Oscillation Frequency : 10 to 55 to 10Hz for 1Min.
Q Change : within r30% Amplitude : 1.5mm
RDC : within Specification Time : 2Hrs. for each Axis (X, Y & Z), Total 6Hrs.
1-1-2 Resistance to Appearance : No Damage Pre-heating : 150qC, 1Min.
Soldering Heat Solder Composition : Sn/Pb = 63/37
Solder Temperature : 260 r 5qC
Immersion Time : 10 r 1Sec.
1-1-3 Solderability The electrodes shall be at least 90% covered Pre-heating : 150qC, 1Min.
with new solder coating. Solder Composition : Sn/Pb = 63/37
Solder Temperature : 230 r 5qC
Immersion Time : 4 r 1Sec.
1-2 ENVIRONMENTAL PERFORMANCE
NO. ITEM SPECIFICATION TEST CONDITIONS
1-2-1 Temperature Shock Appearance : No Damage 10 Cycles (Air to Air) 1 Cycles shall Consist of :
L Change : within r10% 30Min. Exposure to -55qC
L Change : within r30% 30Min. Exposure to -125qC
RDC : within Specification 15Sec. Max. Transition between Temperatures
Measured after Exposure in the Room Condition for 24Hrs.
1-2-2 Temperature Cycle One Cycle
Step Temperature (qC) Time (Min.)
1 -25 r 330
2 25 r 23
3 85 r 330
4 25 r 23
Total : 100 Cycles
Measured after Exposure in the Room Condition for 24Hrs.
1-2-3 Humidity Resistance Temperature : 40 r 2qC
Relative Humidity : 90 ~ 95%
Time : 1000Hrs.
Measured after Exposure in the Room Condition for 24Hrs.
1-2-4 High Temperature Temperature : 85 r 3qC
Resistance Relative Humidity : 20%
Applied Current : Rated Current
Time : 1000Hrs.
Measured after Exposure in the Room Condition for 24Hrs.
1-2-5 Low Temperature Temperature : -25 r 3qC
Resistance Relative Humidity : 0%
Time : 1000Hrs.
Measured after Exposure in the Room Condition for 24Hrs.