CSM_TL-W_DS_E_9_1
1
Flat Inductive Proximity Sensor
TL-W
Standard Flat Sensors in
Many Different Variations
Only 6 mm thick yet provides a sensing
distance of 3 mm (TL-W3MC1).
Aluminum die-cast models also available.
Ordering Information
Sensors [Refer to Dimensions on page 8.]
DC 2-Wire Models
DC 3-Wire Models
*1. Models with a different frequency are also available to prevent mutual interference. The model numbers are TL-W@M@@5 (e.g., TL-W5MD15).
*2. Models with PNP outputs are also available. Ask your OMRON representative for details.
*3. Models are also available with robotics (bend resistant) cables. Add “-R” to the model number. (e.g., TL-W5MC1-R 2M)
Appearance Sensing distance
Model
Operation mode
NO NC
TL-W5MD1 2M *1 *3 TL-W5MD2 2M *3
Appearance Sensing distance Output configuration
Model
Operation mode
NO NC
DC 3-wire, NPN
TL-W1R5MC1 2M ---
TL-W3MC1 2M TL-W3MC2 2M
TL-W5MC1 2M TL-W5MC2 2M
TL-W20ME1 2M TL-W20ME2 2M
DC 3-wire, NPN TL-W5E1 2M TL-W5E2 2M
DC 3-wire, PNP TL-W5F1 2M TL-W5F2 2M
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on
page 7.
Unshielded
5 mm
Unshielded
1.5 mm
*1
*2
*3
3 mm
*1
*2
*3
*1
*2
*3
5 mm
*1
*2
*3
20 mm
*1
*2
*3
Shielded
5 mm
TL-W
2
Ratings and Specifications
DC 2-Wire Models
*1. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*2. For environments that require oil resistance, the upper limit of the ambient operating temperature range is 40°C.
Item Model TL-W5MD@
Sensing distance 5 mm ±10%
Set distance 0 to 4 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page
5.)
Standard sensing object Iron, 18 × 18 × 1 mm
Response frequency *1500 Hz
Power supply voltage
(operating voltage range) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current 0.8 mA max.
Con-
trol
output
Load current 3 to 100 mA
Residual voltage 3.3 V max. (under load current of 100 mA with cable length of 2 m)
Indicators D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
Operation mode (with sensing
object approaching)
D1 Models: NO
D2 Models: NC
Protection circuits Load short-circuit protection, Surge suppressor
Ambient temperature range Operating/Storage: 25 to 70°C (with no icing or condensation) *2
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant *2
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 80 g
Materials Case Heat-resistant ABS
Sensing surface
Accessories Instruction manual
Refer to the timing charts under I/O Circuit Diagrams on page 6 for details.
3
TL-W
DC 3-Wire Models
* For environments that require oil resistance, the upper limit of the ambient operating temperature range is 40°C.
Model
Item TL-W1R5MC1 TL-W3MC@TL-W5MC@TL-W5E1, TL-W5E2
TL-W5F1, TL-W5F2
TL-W20ME1
TL-W20ME2
Sensing distance 1.5 mm ±10% 3 mm ±10% 5 mm ±10% 20 mm ±10%
Set distance 0 to 1.2 mm 0 to 2.4 mm 0 to 4 mm 0 to 16 mm
Differential travel 10% max. of sensing distance 1% to 15% of
sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.)
Standard sensing
object Iron, 8 × 8 × 1 mm Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 50 × 50 ×
1mm
Response
frequency 1 kHz min. 600 Hz min. 500 Hz min. 300 Hz min. 40 Hz min.
Power supply volt-
age (operating volt-
age range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. 12 to 24 VDC (10 to 30 VDC),
ripple (p-p): 20% max.
12 to 24 VDC (10
to 30 VDC), ripple
(p-p): 10% max.
Current
consumption 15 mA max. at 24 VDC (no-load) 10 mA max. 15 mA max. at 24 VDC (no-load) 8 mA at 12 VDC,
15 mA at 24 VDC
Control
output
Load
current
NPN open collector
100 mA max. at 30 VDC max.
NPN open collector
50 mA max. at
12 VDC (30 VDC
max.)
100 mA max. at
24 VDC (30 VDC
max.)
200 mA
100 mA max. at
12 VDC
200 mA max. at
24 VDC
Residual
voltage
1 V max. (under load current of 100 mA with
cable length of 2 m)
1 V max. (under load
current of 50 mA with
cable length of 2 m)
2 V max. (under load current of
200 mA with cable length of 2 m)
1 V max. (under
load current of
200 mA with ca-
ble length of 2 m)
Indicators Detection indicator (red)
Operation mode
(with sensing ob-
ject approaching)
NO C1 Models: NO
C2/B2 Models: NC
E1/F1 Models: NO
E2/F2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 6 for details.
Protection circuits Reverse polarity protection, Surge suppressor
Ambient
temperature range Operating/Storage: 25 to 70°C (with no icing or condensation) *
Ambient
humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence ±2.5% max. of sensing distance at rated volt-
age in the rated voltage ±10% range
±2.5% max. of sens-
ing distance at rated
voltage in the rated
voltage ±20% range
±2.5% max. of sensing distance at rated voltage in
the rated voltage ±10% range
Insulation
resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration
resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y, and Z directions
Destruction:
500 m/s2 10
times each in X,
Y, and Z direc-
tions
Degree of
protection IEC 60529 IP67, in-house standards: oil-resistant *
Connection
method Pre-wired Models (Standard cable length: 2 m)
Weight
(packed state) Approx. 70 g Approx. 80 g Approx. 100 g Approx. 210 g
Materi-
als
Case Heat-resistant ABS Aluminum die-cast Heat-resistant
ABS
Sensing
surface Heat-resistant ABS
Accessories Mounting Bracket, Instruction manual Instruction manual
TL-W
4
Engineering Data (Reference Value)
Sensing Area
TL-W1R5MC1 TL-W3MC1 TL-W5MC1/-W5MD@
TL-W5E/-W5F TL-W20@
6 4 2 0 2 4
4
3
2
1
Y
X
Sensing head
Distance Y
(mm)
Distance X (mm)
6 4 2 0 2 4
4
3
2
1
Y
X
Distance X (mm)
Sensing head
Distance
Y (mm)
8 6 4 2 0 2 4 6 8
6
5
4
3
2
1
Y
X
Distance X (mm)
Sensing head
Distance
Y (mm)
10 8 6 4 2 0 2 4 6 8
6
5
4
3
2
1
Y
X
Distance X (mm)
Sensing head
Distance
Y (mm)
20 15 10 5 0 5 10 15 20
30
25
20
15
10
5
Y
X
Distance X (mm)
Sensing head
Distance
Y (mm)
5
TL-W
Influence of Sensing Object Size and Material
TL-W1R5MC1 TL-W3MC1 TL-W5MC1
TL-W5E@/-W5F@/-W5MD@TL-W20@
10 20 30 40 50 60
4
3
2
1
0
X
d ×
d t = 1 mm
Distance X (mm)
Side length of sensing object: d (mm)
Brass
Aluminum
Iron
Copper
Stainless steel (SUS304)
10 20 30 40 50 60
4
3
2
1
0
X
d ×
d t = 1 mm
Distance X (mm)
Side length of sensing object: d (mm)
Brass
Aluminum
Iron
Copper
Stainless steel (SUS304)
20100
7
6
5
4
3
2
1
X
60504030
d ×
d t = 1 mm
Distance X (mm)
Side length of sensing object: d (mm)
Iron
Stainless steel
(SUS304)
Brass
Copper
Aluminum
5 10 15 20 25 30 35 40 45
6
5
4
3
2
1
0
X
d ×
d t = 1 mm
Distance X (mm)
Side length of sensing object: d (mm)
Brass
Aluminum
Iron
Stainless steel
(SUS304)
10 20 30 40 50 60 70 80 90
24
22
20
18
16
14
12
10
8
6
4
2
0
X
d ×
d t = 1 mm
Distance X (mm)
Side length of sensing object: d (mm)
Brass
Aluminum
Iron
Stainless steel
(SUS304)
TL-W
6
I/O Circuit Diagrams
DC 2-Wire Models
DC 3-Wire Models
Operation mode Model Timing chart Output circuit
NO TL-W5MD1
NC TL-W5MD2
Operation mode Model Timing chart Output circuit
NO
TL-W1R5MC1
TL-W3MC1
TL-W5MC1
NC TL-W3MC2
TL-W5MC2
NO TL-W5E1
TL-W20ME1
NC TL-W5E2
TL-W20ME2
NO TL-W5F1
NC TL-W5F2
80 (TYP)100(%) 0
Sensing
object
Stable sensing
area
Non-sensing area
Unstable
sensing
area
Set position
Proximity Sensor
ON
OFF
ON
OFF
ON
OFF
Setting indicator (green)
Operation indicator (red)
Control output
Rated
sensing
distance
0 V
+V
Load
Brown
Blue
Proximity
Sensor
main
circuit
Note: The load can be connected to either
the +V or 0 V side.
0100(%)
Proximity Sensor
Sensing
object
Sensing area
Non-sensing area
ON
OFF
ON
OFF
Operation indicator (red)
Control output
Rated sensing distance
Sensing object Present
Not present
Output transistor
(load)
ON
OFF
Detection indicator (red) ON
OFF
0 V
+V
100 Ω
*
* Load current: 100 mA max.
Output
Load
Brown
Black
Blue
Proximity
Sensor
main
circuit
Sensing object Present
Not present
Output transistor
(load) ON
OFF
Detection indicator
(red)
ON
OFF
Sensing object Present
Not present
Operate
Reset
Load (between brown
and black leads)
Output voltage (between
black and blue leads) High
Low
Detection indicator (red) ON
OFF
0 V
Tr
+V
100 Ω
4.7 kΩ
2.2 Ω*2
*1
Load
Brown
Black
*1. Load current: 200 mA max.
*2. When a transistor is connected.
Blue
Output
Proximity
Sensor
main
circuit
Sensing object Present
Not present
Operate
Reset
Load (between brown
and black leads)
Output voltage (between
black and blue leads)
High
Low
Detection indicator (red) ON
OFF
Sensing object Present
Not present
Operate
Reset
Load (between blue
and black leads)
Output voltage (between
blue and black leads)
High
Low
Detection indicator (red) ON
OFF
100 Ω
4.7 kΩ
2.2 Ω
0 V
Tr
+V
*2
*1
Brown
Black
Blue
Output
Proximity
Sensor
main
circuit
*1. Load current: 200 mA max.
*2. When a transistor is connected.
Load
Sensing object Present
Not present
Operate
Reset
Load (between blue
and black leads)
Output voltage (between
blue and black leads) High
Low
Detection indicator (red) ON
OFF
7
TL-W
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use this product under ambient conditions that exceed the
ratings.
Design
Influence of Surrounding Metal
When mounting the Sensor within a metal panel, ensure that the
clearances given in the following table are maintained. Failure to
maintain these distances may cause deterioration in the performance
of the Sensor.
Influence of Surrounding Metal (Unit: mm)
Mutual Interference
When installing Sensors face-to-face or side-by-side, ensure that the
minimum distances given in the following table are maintained.
Mutual Interference (Unit: mm)
Note: Values in parentheses apply to Sensors operating at different
frequencies.
* Mutual interference will not occur for close-proximity mounting if models with
different frequencies are used together.
Mounting
Use M3 flat-head screws to mount the TL-W1R5MC1 and TL-
W3MC1.
Do not exceed the torque in the following table when tightening the
resin cover screws.
Adjustment
Turning ON the Power
An error pulse will occur (approximately 1 ms) if adjustments are
made when turning ON the power or making AND connections.
Applicable e-CON Connector Models and Manufacturers
The companies and model number of e-CON connections that can be used with Sensor cables are listed in the following table.
Confirm applicability when purchasing e-CON connectors for connection to Pre-wired Sensors.
WARNING
Precautions for Correct Use
Model Distance l m n
TL-W1R5MC1 2
0
8
TL-W3MC@312
TL-W5MD@520
TL-W5MC1
TL-W20ME@25 16 100
TL-W5E@/-W5F@0020
nll
Sensing
surface
Proximity
Sensor
Metals on Both Sides and
in Front of the Sensor
mSensing surface
Proximity
Sensor
Metal on a Single Side
(Not Exceeding the Height
of the Sensor Surface)
Model Distance A B
TL-W1R5MC1 75 (50) 25 (8) *
TL-W3MC@90 (60) 30 (10) *
TL-W5MD@120 (80) 60 (30)
TL-W5MC1@
TL-W20ME@200 (100) 200 (100)
TL-W5E@/-W5F@50 35
Model Torque
TL-W1R5MC1
0.98 N·m
TL-W3MC@
TL-W5MD@
TL-W20M@1.5 N·m
AB
Model Applicable e-CON Connector Manufacturer
TL-W1R5@/-W3@XN2A-1470 Cable Plug Connector OMRON
TL-W
8
Dimensions
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
TL-W1R5MC1
1
5
R1.6
7.8
7
8
R1.6
3.2
3.2
0.2
3.2 dia.
5.5
6 dia.
90°
98
8
5±0.2
16±0.2
25
3
16
22.4
*
Mounting hole for M3
flat-head screw
* 2.9-dia. vinyl-insulated round cable with
3 conductors (Conductor cross section:
0.14 mm2, Insulator diameter: 0.9 mm),
Standard length: 2 m
Indicator
Indicator
Detection indicator
(red)
Sensing surface
(See note.)
Note: Mounting hole dimension: 17 ±0.2.
Material: Stainless steel (SUS304)
Mounting Bracket (Attachment)
TL-W3MC@
1
5.5
10
R1.6
R1.6
7.8
3.2
16
22.4
3.2
0.2
6
9
3.2 dia.
6 dia.
90°
98
5±0.2
17±0.2
3
10
27
*
Mounting hole for M3
flat-head screw
Indicator
* 2.9-dia. vinyl-insulated round cable with
3 conductors (Conductor cross section:
0.14 mm2, Insulator diameter: 0.9 mm),
Standard length: 2 m
Indicator
Detection indicator
(red)
Sensing surface
(See note.)
Note: Mounting hole dimension: 17 ±0.20.
Material: Stainless steel (SUS304)
Mounting Bracket (Attachment)
TL-W5MC@
TL-W5MD@
*1
3.5
5
4
4.5
8.5
18
30.5
18 12±
0.1
12.5
6.5 7.5 8
10
*1. TL-W5MC1
4-dia. vinyl-insulated round cable with 3
conductors (Conductor cross section: 0.2 mm2,
Insulator diameter: 1.2 mm), Standard length: 2 m
TL-W5MD@
4-dia. vinyl-insulated round cable with 2
conductors (Conductor cross section: 0.3 mm2,
Insulation diameter: 1.3 mm), Standard length: 2 m
*2. C Models: Detection indicator (red)
D Models: Operation indicator (red),
Setting indicator (green)
Indicator *2
Sensing
surface
TL-W5E@
TL-W5F@
Two, 4.5 dia.
15±0.2
3
10
4
4.2 dia.
*
(2)
50
10.5
4.5
8
10
0
-0.4
24.9 15
7.2 dia.
16-dia. sensing
surface
Detection indicator (red)
* 4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.2 mm2, Insulator
diameter: 1.2 mm), Standard length: 2 m
Mounting Hole
Dimensions
TL-W20ME@
30±0.1
40
5
18
27±0.1 206
23 1
18
53
5
1.5
Sensing surface
Detection
indicator (red)
Two, 5.5-dia.
mounting holes
6-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.5 mm2, Insulator
diameter: 1.9 mm), Standard length: 2 m
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omrons exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyers application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyers application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omrons Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omrons representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.9
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2014 All Right Reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
E39-L104 E3ZM-LS64H 2M E3ZM-R61 2M E3ZM-T61 2M E3ZM-LS61H 2M E3ZM-D62 2M E3ZM-LS62H 2M TL-
W1R5MC1-R TL-W20ME1 10M TL-W20ME1 5M TL-W20ME2 TL-W3MC2 10M TL-W3MC2 5M TL-W5E1 10M TL-
W5E2-5M TL-W5F1-5M TL-W5F2 5M TL-W5MD1 TL-W3MC2 E39-L142 E3ZM-D67 E3ZM-D82 2M E3ZM-D87
E3ZM-LS66H E3ZM-LS67H E3ZM-LS69H E3ZM-LS81H 2M E3ZM-LS82H 2M E3ZM-LS84H 2M E3ZM-LS84H 5M
E3ZM-LS86H E3ZM-LS87H E3ZM-LS89H E3ZM-R66 E3ZM-R81 2M E3ZM-R86 E3ZM-T66 E3ZM-T81 2M E3ZM-
T81 5M E3ZM-T83 2M E3ZM-T86 E3ZM-T88 TL-W3MC1-R 2M TL-W5MD15 2M TL-W5MD1 5M TL-W5MB2 TL-
W5MD2 TL-W5MD15 TL-W5MB1 TL-W5F1 TL-W5MC2 TL-W5MC1 TL-W3MC1 TL-W5E1 TL-W5F2 TL-W3MB1
TL-W3MB2-5 5M TL-W1R5MC15 2M TL-W20ME1 TL-W5E1-5M TL-W5E2 TL-W5F1-M1J 0.3M TL-W1R5MC1 TL-
W3MC1 5M TL-W3MC1-R 5M TL-W3MC2-R 5M TL-W3MC1 6M TL-W5MC15 TL-W2R5MC1-3 2M TL-W5MC1 5M
TL-W5MD2-M1GJ 0.3M TL-W3MC15 TL-W1R5MB1 TL-W1R5MB1 6M TL-W1R5MB1-5M TL-W3MB1-R 2M