RECTIFIER ASSEMBLIES Single Phase Full Wave Bridges PMC Power Modules High Voltage, High Current FEATURES PIV: From 2.5kV to 60kV 12A in Oil 300A Surge Current Fast Recovery Low Leakage ABSOLUTE MAXIMUM RATINGS Peak inverse Voltage ........ icc cee cee eee etre tenes eens 2.5kV to 15kV Maximum Average Rectified Current..............45 .. See Electrical Specifications Maximum One Cycle Surge 8.3mS .......... eee eee .. See Electrical Specifications Operating and Storage Temperature Range ............. cece eee eee -65C to +150C MECHANICAL SPECIFICATIONS PMC101-PMC105 PMC101X-PMC105X PMC201 -PMC203 PMC201X -PMC203X DESCRIPTION The PMC POWER MODULE is a densely packaged single phase high voltage bridge rectifier assembly. Typical applications include high power transmitters, cable fault detectors, and shipboard radar systems, to name a few. PMC101 -PMC105 TOLERANCE: PMC101X-PMC105X XX + 015 (.361) + CASE LENGTH + .030 (,762)-| PMC201-PMC203 , 55 (13.97) TYP. PMC201X -PMC203X 37 (9.398) R TYP 4" .25 (6.35) pm a 25 (6.35) v{ | \ Y z t+ Ey 25 (6.35) z- 10.32 UNC 2B .25 a8 TYP 2PL FOR MOUNTING $2 8 AND ELECTRICAL UP S 2 TO 6.05 LENGTH ey yr Ti] 25 28 * 25 FOR seal } 7.18 THRU 13,75 LONG. (25 (6.35) 25 (6.38) R TYP CL aL Ok oe" M 75 \ NI PLATED .062 (1.575) OHFC 19.08) HEAT SINK TYP. 1 8a Wl MOUNTING & ELECTRICAL SPACING CASE LENGTH PART NUMBER | INCHES MM INCHES MM PMG101, 101X 58 14.73 2.75 69.85 PMC102, 102X 1.13 28.70 4.95 128.73 PMC103, 103X 1.68 42.67 7.15 181.61 PMC104, 104X 2.23 56.64 9.35 237.49 PMC105, 105X 3.33 84.58 13.75 349.25 PMG201, 201X 1.43 28.70 4.95 125.73 PMCG202, 202X 2.23 56.64 9.35 237.49 PMC203, 203X 3.33 84.58 13.75 349.25 NOTE: SINGLE PHASE FWB REQUIRES EXTERNAL CONNECTION. UNIT AVAILABLE WITH EITHER POSITIVE OR NEGATIVE a | OUTBOARD TERMINATION. ADD SUFFIX P OR N. Dimensions in inches and (millimeters) Reformatted 12/79 471 PMA [) me UNITRODE PMC101-105 PMC101X-105X PMC201-203 PMC201X -203X ELECTRICAL SPECIFICATIONS (at 25C unless noted) MAXIMUM RATINGS Maximum Peak Maximum Maximum Maximum Maximum Reverse Inverse Reverse Forward Average: One Cycle Recovery Voltage Current Voitage Rectified Surge M" Mounting & Case Time @ PIV Currentt 8.3mS Electrical Spacing Length Tar* PIV Ip Ve lo @ 50C Ip(surge) Type Type kV 25C [100C | @ 3.0A Peak NC FA Oil 2uS 250nS HA BA Vv Ake | Ake A A Inches MM Inches MM PMC101 PMC101X 2.5 2 100 2 48 6 150 58 14.73 2.75 69.85 PMC102 | PMC102X 5 2 100 10 2 4.8 6 150 1.13 28.70 4.95 125.73 PMC103 | PMC103X 7.5 2 100 45 2 4.8 6 460 1.68 42.67 7.15 181.61 PMC104 PMC104X 10 2 100 20 2 48 6 150 2.23 $6.64 9.35 237.49 PMC105 | PMC105X 15 2 100 30 2 4.8 6 150 3.33 84.58 13.78 349.25 @ 6.0A Peak PMC201 PMC201X 2.5 2 100 5 4 9.6 12 300 1.43 28.70 4.95 125.73 PMC202 | PMC202Xx 5 2 100 10 4 9.6 12 300 2.23 56.64 9.35 237.49 PMC203 PMC203X 75 2 100 15 4 9.6 12 300 3.33 84.58 13.75 349.25 * Reverse recovery test conditions for each cell prior to assembly Ip =400mA, |Rp=800MA, I_R=200MA. * For natural air convection operation unit must be mounted horizontally with no air restrictions. Forced air ratings are with a minimum air flow of (TBD). Notes: 1. For operation in air unit to be corona free to (TBD) test conditions (TBD). 2. Junction to heat sink thermal resistance (TBD). 3. Consult factory for series and/or parallel applications for special matching. 4. |o ratings @ 50C linearly derate to 0 @ 150C. 5. Oil and air operation any position. UNITRODE CORPORATION + 5 FORBES ROAD LEXINGTON, MA 02173 TEL. (617) 861-6540 TWX (710) 326-6509 TELEX 95-1064 472 PRINTED IN U.S.A.