General Description:
CAT3, 4-Pair, U/UTP-Unshielded, Riser-CMR, Premise Horizontal Cable, 24 AWG Solid Bare Copper
Conductors, Polyolefin Insulation, PVC Jacket
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
424 Solid BC - Bare Copper
Total Number of Conductors: 8
Insulation
Insulation Material:
Insulation Material
PO - Polyolefin
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Outer Jacket Diameter:
Nom. Dia. (in.)
0.197
Pair
Pair Color Code Chart:
Number Color
1White/Blue Stripe & Blue
2White/Orange Stripe & Orange
3White/Green Stripe & Green
4White/Brown Stripe & Brown
Mechanical Characteristics (Overall)
Operating Temperature Range: -20°C To +75°C
Bulk Cable Weight: 29 lbs/1000 ft.
Max. Recommended Pulling Tension: 35 lbs.
Min. Bend Radius/Minor Axis: 1 in.
Min. Bend/Installation: 1.900 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMR, CMX-Outdoor
Page 1 of 3 10-30-2013
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1229A1 Multi-Conductor - Category 3 Nonbonded-Pair Cable
CEC/C(UL) Specification: CMR, CMX-Outdoor
EU Directive 2011/65/EU (ROHS II): Yes
IEEE Specification: 802.3 10BaseT, 100BaseT4
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Other Specification: NEMA WC-63 Category 3, Verified to ANSI/TIA-586-C.2, Category 3
Flame Test
UL Flame Test: UL1666 Vertical Riser
C(UL) Flame Test: FT4
CSA Flame Test: FT4
Plenum/Non-Plenum
Plenum (Y/N): No
Plenum Number: 1245A2
Electrical Characteristics (Overall)
Nom. Mutual Capacitance:
Capacitance (pF/ft)
15
Maximum Capacitance Unbalance (pF/100 m): 330
Nominal Velocity of Propagation:
VP (%)
70
Maximum Delay:
Delay (ns/100 m)
538 @ 100MHz
Max. Delay Skew:
Delay Skew (ns/100 m)
45
Maximum Conductor DC Resistance:
DCR @ 20°C (Ohm/100 m)
9.38
Max. Operating Voltage - UL:
Voltage
300 V RMS
Maximum DCR Unbalanced:
DCR Unbalance @ 20°C (%)
5
Electrical Characteristics-Premise (Overall)
Premise Cable Elelctricals:
Freq. (MHz) Max. Attenuation (dB/100 m) Min. NEXT (dB) Min. PSNEXT (dB) Min. SRL (dB) Fitted Imp. (Ohms)
12.56 41.0 No Spec 12.0 100 ± 15%
Page 2 of 3 10-30-2013
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1229A1 Multi-Conductor - Category 3 Nonbonded-Pair Cable
45.58 32.0 No Spec 12.0 100 ± 15%
10 9.71 26.0 No Spec 12.0 100 ± 15%
16 13.10 23.0 No Spec 9.96 100 ± 15%
Notes (Overall)
Notes: Jacket sequentially marked at 2 ft. intervals. Third party verified to ANSI/TIA-568-C.2, Category 3.
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
1229A1 008U1000 1,000 FT 22.000 LB GRAY CAT3 4PR U/UTP CMR BOX
Revision Number: 4 Revision Date: 02-06-2013
© 2013 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 10-30-2013
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1229A1 Multi-Conductor - Category 3 Nonbonded-Pair Cable