DATA S H E E T MINIATURE SIGNAL RELAY EA2 SERIES COMPACT AND LIGHTWEIGHT DESCRIPTION The EA2 series has reduced package size and power consumption to other NEC Conventional relays. Furthermore, it complies with 1500 V surge-voltage requirement of FCC part 68 by the unique structure and the efficient magnetic circuit FEATURES TM Low power consumption TM Compact and light weight TM 2 form c contact arrangement TM Low magnetic arrangement TM Breakdown voltage : 1000 Vac (surge voltage 1500 V), FCC Part 68 compliant TM Tube packaging TM UL recognized (E73266), CAS certified (LR46266) APPLICATIONS Electronic switching systems, PBX, key telephone systems, automatic test equipment and other electronic equipment. ATTENTION DO NOT EXCEED MAXIMUM RATINGS. Do not use relays under exceeding conditions such as over ambient temperature, over voltage and over current. Incorrect use could result in abnormal heating, damage to related parts or cause burning. READ CAUTIONS IN THE SELECTION GUIDE. Read the cautions described in NEC's "Miniature Relays" (ER0046EJ) when you choose relays for your application. Document No. ER0001EJ6V0DS00 (6th edition) Date Published June 1999 M Printed in Japan (c) 1989 (1996) EA2 SERIES OUTLINE DRAWING AND DIMENSIONS PAD LAYOUT (bottom view) Unit : mm (inch) 0.33 (0.013) 7.62 (0.30) 10- 0.8(0.03) (0.36) 2.54 (0.10) 0.5 (0.02) 0.25 (0.01) 10.16 (0.40) Note. Tolerance + - 0.1 ( + - 0.004) unless othewise specified 7.62 3.5 2.54 2.54 (0.10) 9.2 max. (0.21) (0.56) 5.4 max. 14.2 max. (0.10) (0.30) Note. tolerance + - 0.2 ( + - 0.008) unless otherwise specified Dimensions in show basic size. NJ type : Cover height-6.3 mm (0.248), Leads-2.8 mm (0.11) MARKINGS SAFETY STANDARD AND RATING 1 2 UL Recognized (UL508) File No E73266 CSA Certificated (CSA C22.2 No 14) File No LR46266 30 Vdc, 1 A (Resistive) 110 Vdc, 0.3 A (Resistive) 125 Vdc, 0.5 A (Resistive) EA2-5 q Part number JAPAN 5 9106 Spacing : UL114, UL478 w Manufacturer e Country of origin 3 r Date code 4 t Index mark of relay direction Standard type (pin No. 1, 10.) 1 y UL, CSA Marking 2 EA2-5NU JAPAN 3 9106 5 6 4 UL recognized, CSA certified type PIN CONFIGURATIONS S 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 - + + + - + - RS - + - 10 9 8 7 6 10 9 8 7 6 Index mark of relay direction Non-latch type (not energized position) Single coil latch type (reset position) 10 9 8 7 6 R Double coil latch type (reset position) S : Coil polarity of set (operate) R : Coil polarity of reset (release) 2 DATA SHEET ER0001EJ6V0DS00 EA2 SERIES PART NUMBER SYSTEM EA2 - 3 S NU Nil : Standard type NU : UL recognized, CSA certified type NJ : Trimmed leads type NP : Silver-palladium alloy contact (with gold alloy overlay) UL recognized, CAS certified type Latch type Nil : Non-latch type (standard type) S : Single coil latch type T : Double coil latch type Nominal coil voltage 3, 4.5, 5, 6, 9, 12, 24 Volts EA2 series PERFORMANCE CHARACTERISTICS Contact Form Contact rating 2 form c Maximum switching power 30 W (resistive) 62.5 VA (resistive) Maximum switching voltage 220 Vdc 250 Vac Maximum switching current 1A Maximum carrying current 2A Minimum contact ratings 10 mVdc, 10 A 1 Initial contact resistance 50 m typ. (Initial) Contact material Silver alloy with gold alloy overlay Nominal operating Power Minimum operating Power Non-latch type and double coil latch type 140 mW (3 to 12 V) 200 mW (24 V) Single coil Latch type 100 mW (3 to 12 V) 150 mW (24 V) Non-latch type and double coil latch type 79 mW (3 to 12 V) 113 mW (24 V) Single coil latch type 56 mW (3 to 12 V) 85 mW (24 V) Operate time (excluding bounce) Approximately 2 ms without diode Release time (excluding bounce) Approximately 1 ms without diode Insulation resistance 1000 M at 500 Vdc Between open contacts Breakdown voltage Between adjacent contacts 1000 Vac (for one minute) 1500 V surge (10 x 160 s 2) Between coil and contact Shock resistance 735 m / s 2 (75 G) (misoperating) 980 m / s 2 (100 G) (destructive failure) Vibration resistance 10 to 55 Hz at double amplitude of 3 mm (20 G) (misoperating) 10 to 55 Hz, at double amplitude of 5 mm (30 G) (destructive failure) Ambient temperature -40C to 85C Coil temperature rise 18 degrees at nominal coil voltage Noload 1 x 108 operations (Non-latch type) 3 1 x 107 operations (latch type) Running specifications Load 50 Vdc 0.1 A (resistive), 1 x 106 operations at 85C, 2 Hz 10 Vdc 10 mA (resistive), 1 x 106 operations at 85C, 2 Hz Weight Approximately 1.5 grams 1 This value is a reference value in the resistance load. Minimum capacity changes depending on seitching frequency and environment temperature and the load. 2 Rise time : 10 s, fall time : 160 s 3 This shows a number of operation where it can be running by which a fatal defect is not caused, and a number of operation by which a steady characteristic is maintained is 1 x 107 times. DATA SHEET ER0001EJ6V0DS00 3 EA2 SERIES PRODUCT LINEUP Non-latch Type at 20C Coil Resistance () 10 % Nominal Coil Voltage (Vdc) 3 Must Operate Voltage (Vdc) 64.3 Must Release Voltage (Vdc) 2.25 0.3 4.5 145 3.38 0.45 5 178 3.75 0.5 6 257 4.5 0.6 9 579 6.75 0.9 12 1028 9 1.2 24 2880 18 2.4 Single-Coil Latch Type at 20C Nominal Coil Voltage (Vdc) Coil Resistance () 10 % Must Operate Voltage (Vdc) Must Release Voltage (Vdc) 90 2.25 2.25 4.5 202.5 3.38 3.38 5 250 3.75 3.75 6 360 4.5 4.5 9 810 6.75 6.75 12 1440 9 9 24 3840 18 18 3 Double-Coil Latch Type (Can not be driven by revese polarity for reverse operation.) Nominal Coil Voltage (Vdc) 3 4.5 5 6 9 12 24 Note 4 Must Operate Voltage (Vdc) Coil Resistance () 10 % at 20C Must Release Voltage (Vdc) S 64.3 2.25 - R 64.3 - 2.25 S 145 3.38 - R 145 - 3.38 S 178 3.75 - R 178 - 3.75 S 257 4.5 - R 257 - 4.5 S 579 6.75 - R 579 - 6.75 S 1028 R 1028 - 9 S 2880 R 2880 - 18 9 - 18 - Test by pulse voltage S : Set coil (pin No.1... + , pin No.5... - ) R : Reset coil (pin No.10... + , pin No.6... - ) The latch type relays should be initalized at appointed position before using, and should be enegized to specific polanity by a bone polabity to avoid wrong operation. Any special coil requirement, please contact NEC for availability. DATA SHEET ER0001EJ6V0DS00 EA2 SERIES TYPICAL PERFORMANCE DATA SWITCHING CAPACITY 80 DC Load (resistive) AC Load (resistive) Coil Temperature Rise (C) Switching Current (A) 2.0 COIL TEMPERATURE RISE 1.0 0.5 0.4 0.3 0.25A 0.136A 0.2 30 100 200 Switching Voltage (V) 60 40 20 0 250 Vdc 220 Vdc 100 200 300 400 Applied Power (mW) Release Time or Bounce Time at Release (ms) OPERATE TIME Operate Time 2 Bounce Time at Operate 1 0 100 200 300 400 500 RELEASE TIME WITHOUT DIODE RELEASE TIME WITH DIODE Release Time or Bounce Time at Release (ms) Release Time or Bounce Time at Release (ms) Applied Power (mW) 2 Release Time 1 Bounce Time at Release 100 0 200 300 400 500 Release Time 2 1 0 Bounce Time at Release 100 200 300 400 500 Applied Power (mW) Applied Power (mW) RUNNING SPECIFICATIONS (Noload) Temperature : 85C Drive : 5 Vdc, 10 Hz 50% duty Operate Voltage or Release Voltage (V) 5 Contact Resistance (m) Sample : EA2-5 n = 10 Load : None Operate Voltage Release Voltage 4 3 2 1 0 1 5 10 2 3 Number of Operations ( x 10 6 operations) 1000 Make contact Break contact 500 300 200 100 50 30 20 10 0 DATA SHEET ER0001EJ6V0DS00 1 2 3 5 10 Number of Operations ( x 10 6 operations) 5 EA2 SERIES 50 40 30 20 10 Max. 0 -10 -20 -30 -40 -50 Min. I II III IV Layout V VI Drift of Release Voltage (%) Drift of Operate Voltage (%) MAGNETIC INTERFERENCE 50 40 30 20 10 0 -10 -20 -30 -40 -50 Max. Min. I II III IV Layout V VI 2.54 ON Layout I OFF OFF ON OFF ON OFF Layout II Layout III ON OFF ON OFF ON OFF Layout IV 2.54 ON Sample Layout VI Layout V Mounting Layout (mm) PACKAGE Dimensions of Relay Tube (Unit : mm) 40 pieces / Tube Material : Polyvinyl chloride (auti-static treated) 586 + -1 12.0 + - 0.3 (4.6) (0.5 t) (6.2) (2.5) 13.7 + - 0.3 ( ) Reference (4.5) Outline of Package Rubber stopper (Red) Rubber stopper (Green) Index Mark 6 DATA SHEET ER0001EJ6V0DS00 EA2 SERIES GUIDE TO APPLICATIONS 1. When connecting coils, refer to the pin configuration to prevent misoperation or malfunction. 2. The latch type relay should be initialized at the appointed position (set or reset position) when using, and should be energized or deenergized to the specified polarity to avoid wrong operations by reversed contact state. 3. Soldering should be done at 250C within 10 sec. 4. Ultrasonic cleaning is not recommended to keep reliable contact performance. Alcohol-based solvents are available as proper solvents. 5. Pressurized stress on the relay cover is not favorable to keep reliable operation of the relay during operation. 6. Minimum contact load of the relay is 10 mV, 10 A. This value is a reference value in the resistance load. Minimum capacity changes depending on swiching frequency and environment temperature and the load. DATA SHEET ER0001EJ6V0DS00 7 EA2 SERIES No part of this document may be copied or reproduced in any form or by any means without the prior written consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which may appear in this document. NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual property rights of third parties by or arising from use of a device described herein or any other liability arising from use of such device. No license, either express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of NEC Corporation or others. While NEC Corporation has been making continuous effort to enhance the reliability of its electronic components, the possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or property arising from a defect in an NEC electronic component, customers must incorporate sufficient safety measures in its design, such as redundancy, fire-containment, and antifailure features. NEC devices are classified into the following three quality grades: "Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based on a customer designated "quality assurance program" for a specific application. The recommended applications of a device depend on its quality grade, as indicated below. Customers must check the quality grade of each device before using it in a particular application. Standard: Computers, office equipment, communications equipment, test and measurement equipment, audio and visual equipment, home electronic appliances, machine tools, personal electronic equipment and industrial robots Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster systems, anti-crime systems, safety equipment and medical equipment (not specifically designed for life support) Specific: Aircrafts, aerospace equipment, submersible repeaters, nuclear reactor control systems, life support systems or medical equipment for life support, etc. The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books. If customers intend to use NEC devices for applications other than those specified for Standard quality grade, they should contact an NEC sales representative in advance. Anti-radioactive design is not implemented in this product.