For more Information
please call
1-800-Belden1
General Description:
Belden^s .050" pitch gray ribbon cable was designed for general purpose electronic interconnect
applications. The cable provides reliable mass-termination to standard IDC connectors.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
20 28 7x36 TC - Tinned Copper
Total Number of Conductors: 20
Conductor Spacing Center to Center: .050 +/- .002
Conductor Spacing Outside Center to Outside Center: .95 +/- .008
Insulation
Insulation Material:
Insulation Material Wall Thickness (in.)
PVC - Polyvinyl Chloride .010
Insulation Resistance: >10,000 Megaohms
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Overall Cable
Overall Nominal Thickness: .035 +/- .003
Overall Nominal Width: 1.00 +/- .008
Mechanical Characteristics (Overall)
Operating Temperature Range: -40°C To +105°C
Bulk Cable Weight: 23 lbs/1000 ft.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
UL AWM Style: 2651
UL Rating: 105°C, 300 V RMS, VW-1
CSA Specification: AWM I A 105°C 300 V FT1
CSA Rating: 105°C, 300 V RMS, FT1
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 07/01/2005
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: VW-1
CSA Flame Test: FT1