Temperature Sensor E52 CSM_E52_DS_E_7_2 A Wide Variety of High-precision Temperature Sensors * Ideal for the thermal input devices of Temperature Controllers. * Select from a wide variety of Temperature Sensors according to the temperature to be measured, location, and environment, and also according to the type and shape of the terminal. * General-purpose, low-cost, and exclusive models are available. Refer to Safety Precautions for All Temperature Controllers. Ordering Information List of Models Classification Generalpurpose Models Description TemperaElement ture range type (See note 3.) Sheathed E52-P@A platinum resistance E52-P@C thermometer -200C to 450C Standard E52-P@B platinum resistance E52-P@C thermometer 0C to 450C Sheathed thermocouple 0C to 1,050C Standard thermocouple Low-cost Models Model and appearance E52-CA@A E52-IC@A Pt100 K (CA) J (IC) Conductor type Class 3-conduc- B tor system Nongrounded type 2 (0.75) Protective tubing material SUS316 SUS316 Terminal type Page Exposed 5 lead wires Enclosed terminals 6 Exposed terminals 6 Enclosed terminals 7 Exposed 9 lead wires E52-CA@B E52-IC@B Exposed terminals 13 E52-CA@C E52-IC@C Enclosed terminals 13 Exposed terminals 14 Enclosed terminals 15 JIS ceramic Enclosed JIS special terminals ceramic 16 E52-CA@B E52-IC@B 0C to 1,000C SUS316 SUS310S E52-CA@C E52-IC@C E52-PR@C 0C to 1,400C R (PR) Low-cost E52-P10AE platinum E52-P6D resistance E52-P6F thermometer -50C to 250C Pt100 Low-cost thermocouple 0C to 400C K (CA) J (IC) E52-CA@AS E52-IC@AS 2 (0.25) 3-conduc- B tor system Nongrounded type SUS304 Exposed 17 lead wires 2 (0.75) 18 E52-CA1D E52-IC1D E52-CA6F E52-IC6F E52-CA6D E52-IC6D Grounded type 19 E52-CA10AE E52-IC10AE Nongrounded type 21 Note: 1. Exclusive models are provided on the following page. 2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use. 3. The temperature range varies with the material, thickness, and construction of the protective tubing. 1 E52 Classification Description Exclusive Models Bayonet spring for molding machines E52-CA2GV E52-IC2GV 0C to 350C K (CA) J (IC) Crimping terminals E52-CA1GT E52-IC1GT 0C to 300C Thermistors Model and appearance TemperaElement ture range type (See note 3.) Conductor type Class Grounded 2 (0.75) type Protective tubing material SUS304 Terminal type Page Exposed 21 lead wires 22 Used for E52-P2GS measuring surface temperatures -50C to 250C Used for E52-P10GR room temperature measurement -50C to 60C Double-el- E52-P20GW ement model -50C to 250C Two 3-conductor systems 23 WaterE52-P10GP proof model E52-P5A-40 0C to 70C 3-conductor system 23 Pt100 3-conduc- B tor system 22 22 -50C to 180C Fluororesin molding 24 Fluororesin tubing 24 27 Corrosion- E52-@@A-1 resistant model -80C to 180C Silicone- E52-CA1D-40 covered lead wires 0C to 300C K (CA) Grounded 2 (0.75) type --- Explosion- E52-@@C-6 proof model -100C to 500C Pt100 3-conduc- B tor system SUS316 Enclosed terminals -100C to 900C K (CA) Nongrounded type -50C to 300C Thermistor Element- 1 interchangeable thermistor SUS304 Exposed 29 lead wires E52-THE5A E52-THE6F E52-THE6D Pt100 3-conduc- B tor system K (CA) Nongrounded type 2 (0.75) 25 2 (0.75) Note: 1. General-purpose models and low-cost models are provided on the previous page. 2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use. 3. The temperature range varies with the material, thickness, and construction of the protective tubing. 2 E52 Accessories It is recommended that the following accessories be used for mounting Temperature Sensors. Accessory Compression Fitting Temperature range 600C max. Mounting example Mounting with Compression Fitting Page 30 Terminal box Compression Fitting PT screw Welding Loose Flange 400C max. Protective tubing Mounting with Loose Flange Terminal box Loose Flange Protective tubing Mounting screw Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the sensing object will cause problems. Note: 1. Use the Loose Flange in normal atmospheric pressure. The Loose Flange is not of airtight construction. 2. Use the Loose Flange at 400C max. 3. Do not apply the Loose Flange to protective tubing diameters other than the applicable ones. Lead Wires Accessory For resistance thermometers For thermocouples (compensating conductor) Specification Temperature range -20C to 70C Standard Vinyl-covered with twelve 0.18-dia. conductors (0.3 mm thick) and 4.8 mm in outer dia. Heat resistive Glass-wool-covered with twenty 0.18-dia. conductors (0.5 mm thick) ex- 0C to 180C ternally shielded with stainless steel, 5.2 mm in outer dia. Sleeve: 0C to 100C Standard Vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) and 3.2 x 5.0 mm in outer dia. Heat resistive Glass-wool-covered with seven 0.3-dia. conductors (0.5 mm thick) exter- 0C to 150C nally shielded with stainless steel, 2.9 x 4.6 mm in outer dia. Sleeve: 0C to 100C -20C to 70C Page --- 32 3 E52 Model Number Structure The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below. Model Number Legend Platinum Resistance Thermometers E52-@@@ D=@@@M 1 2 3 4 5 6 1. Element type P: Pt100 2. Protective tubing length (L) Specify the length in centimeters within the following range: Unit (cm) E52-@@A Diameter (D) Length (L) 3.2 7 to 100 4.8 10 to 600 6.4 13 to 1,300 4. Diameter 3.2: 3.2-mm dia. (Protective tubing construction: Sheathed) E52-@@A and E52-@@C only 4.8: 4.8-mm dia. (Protective tubing construction: Sheathed) E52-@@A and E52-@@C only 6.4: 6.4-mm dia. (Protective tubing construction: Sheathed) E52-@@A and E52-@@C only 8: 8-mm dia. (Protective tubing construction: Standard) E52-@@B and E52-@@C only 10: 10-mm dia. (Protective tubing construction: Standard) E52-@@C only 5. Heat resistance E52-@@B Code Diameter (D) 8 Length (L) Diameter (D) Length (L) 3.2 12 to 100 4.8 15 to 600 6.4 18 to 1,300 8 21 to 100 10 26 to 100 Lead type -20C to 70C Sleeve: 0C to 70C Vinyl-covered NETU 0C to 180C Sleeve: 0C to 100C Glass-wool-covered, externally shielded 20 to 100 E52-@@C Temperature range --- Specify for E52-@@A model only. 6. Lead length (M) Specify the length in meters within the following range for the E52@@A only: Range: 1 to 100 m 3. Terminal A: Exposed lead wires B: Exposed terminals C: Enclosed terminals Examples Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m E52-P42A D=4.8 NETU 10M General-purpose Models Sheathed Platinum Resistance Thermometers Refer to Model Number Legend above for the Pt100. Specifications Element type Pt100 Class JIS class B Sheath material SUS316 Sheath outer diameter 3.2 dia., 4.8 dia., 6.4 dia. Conductor type 3-conductor system Temperature range -200C to 450C (in dry air) 4 E52 Exposed-lead Models E52-P@A Dimensions Red (A) Unit (mm) Y-type crimp terminal for M4 Maker tube Lead wire SUS304 sleeve d White (B) M Black (B) d l 3.2 dia. 8 60 4.8 dia. 8 60 6.4 dia. 8 60 D SUS316 sheath D L Lead Wire * Standard (-20C to 70C): Fully vinyl-covered with twelve 0.18-dia conductors (0.3 mm thick) and 4.8 mm in outer dia. The sleeve resists a temperature range between 0C and 70C. * Heat Resistive (0C to 180C): Fully glass-wool-covered with twenty 0.18-dia. conductors (0.5 mm thick) externally shielded with stainless steel, 5.2 mm in outer dia. The sleeve resists a temperature range between 0C and 100C. * Lead Wire Length (M): 1, 2, 4, or 8 m Model Information Custom-made models are available on request. Refer to page 4 for details. Terminal type Protective tubing diameter D (mm) Exposed-lead 3.2 dia. Models Protective tubing length L (cm) 15 35 20 35 50 6.4 dia. Lead wire length M (m) 1 2 4 8 Model 20 4.8 dia. Lead wire type 20 35 50 Standard E52-P15A D=3.2 1M E52-P15A D=3.2 2M E52-P15A D=3.2 4M E52-P15A D=3.2 8M Heat resistive E52-P15A D=3.2 NETU 1M E52-P15A D=3.2 NETU 2M E52-P15A D=3.2 NETU 4M E52-P15A D=3.2 NETU 8M Standard E52-P20A D=3.2 1M E52-P20A D=3.2 2M E52-P20A D=3.2 4M E52-P20A D=3.2 8M Heat resistive E52-P20A D=3.2 NETU 1M E52-P20A D=3.2 NETU 2M E52-P20A D=3.2 NETU 4M E52-P20A D=3.2 NETU 8M Standard E52-P35A D=3.2 1M E52-P35A D=3.2 2M E52-P35A D=3.2 4M E52-P35A D=3.2 8M Heat resistive E52-P35A D=3.2 NETU 1M E52-P35A D=3.2 NETU 2M E52-P35A D=3.2 NETU 4M E52-P35A D=3.2 NETU 8M Standard E52-P20A D=4.8 1M E52-P20A D=4.8 2M E52-P20A D=4.8 4M E52-P20A D=4.8 8M Heat resistive E52-P20A D=4.8 NETU 1M E52-P20A D=4.8 NETU 2M E52-P20A D=4.8 NETU 4M E52-P20A D=4.8 NETU 8M Standard E52-P35A D=4.8 1M E52-P35A D=4.8 2M E52-P35A D=4.8 4M E52-P35A D=4.8 8M Heat resistive E52-P35A D=4.8 NETU 1M E52-P35A D=4.8 NETU 2M E52-P35A D=4.8 NETU 4M E52-P35A D=4.8 NETU 8M Standard E52-P50A D=4.8 1M E52-P50A D=4.8 2M E52-P50A D=4.8 4M E52-P50A D=4.8 8M Heat resistive E52-P50A D=4.8 NETU 1M E52-P50A D=4.8 NETU 2M E52-P50A D=4.8 NETU 4M E52-P50A D=4.8 NETU 8M Standard E52-P20A D=6.4 1M E52-P20A D=6.4 2M E52-P20A D=6.4 4M E52-P20A D=6.4 8M Heat resistive E52-P20A D=6.4 NETU 1M E52-P20A D=6.4 NETU 2M E52-P20A D=6.4 NETU 4M E52-P20A D=6.4 NETU 8M Standard E52-P35A D=6.4 1M E52-P35A D=6.4 2M E52-P35A D=6.4 4M E52-P35A D=6.4 8M Heat resistive E52-P35A D=6.4 NETU 1M E52-P35A D=6.4 NETU 2M E52-P35A D=6.4 NETU 4M E52-P35A D=6.4 NETU 8M Standard E52-P50A D=6.4 1M E52-P50A D=6.4 2M E52-P50A D=6.4 4M E52-P50A D=6.4 8M Heat resistive E52-P50A D=6.4 NETU 1M E52-P50A D=6.4 NETU 2M E52-P50A D=6.4 NETU 4M E52-P50A D=6.4 NETU 8M 5 E52 Enclosed-terminal Models E52-P@C Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. 34 dia. Aluminum die-cast terminal box 57 SUS304 SUS316 sheath D 65 4 16 19 Cap G3/8, 19 mm between facing sides, 10 inner dia. (with 7-inner-dia. rubber bushing built-in) 35 L Use wiring terminals that fit M3 screws. Terminal box: The permissible temperature is 0C to 80C. Note: The terminals in the cap indicate polarity (A, B, B). Model Information Custom-made models are available on request. Refer to page 4 for details. Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 3.2 dia. 4.8 dia. 6.4 dia. Model Enclosed-terminal Models 20 E52-P20C D=3.2 E52-P20C D=4.8 E52-P20C D=6.4 35 E52-P35C D=3.2 E52-P35C D=4.8 E52-P35C D=6.4 50 E52-P50C D=3.2 E52-P50C D=4.8 E52-P50C D=6.4 75 --- E52-P75C D=4.8 E52-P75C D=6.4 Standard Platinum Resistance Thermometers Refer to Model Number Legend on page 4 for the Pt100. Specifications Element type Pt100 Class JIS class B (See note 2.) Protective tubing material SUS316 Conductor type 3-conductor system Temperature range 0C to 450C (in dry air) Note: 1. Use the sheathed platinum resistance thermometer if condensation is likely to result. 2. Be sure that the thermometer is free of vibration or shock if high temperatures are measured. Exposed-terminal Models E52-P@B Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. Aluminum die-cast terminal box SUS316 protective tubing 10 A 50 B Three, M3 Custom-made models are available on request. Refer to page 4 for details D B 18 Model Information 14 dia. 20 Terminal type 20 dia. 40 L Terminal box: The permissible temperature is 0C to 100C. Exposedterminal Models Protective tubing diameter D (mm) Protective tubing length 8 dia. L (cm) Model 20 E52-P20B D=8 35 E52-P35B D=8 50 E52-P50B D=8 6 E52 Enclosed-terminal Models E52-P@C Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. 98 34 dia. Aluminum die-cast terminal box 22 dia. SUS316 protective tubing 57 SUS316 protective tubing 10 8 dia. 65 10 dia. 90 14 dia. Cap 35 G3/8, 19 mm between facing sides, 10 inner dia. (with 7-inner-dia. rubber bushing built-in) 10 40 dia. Aluminum die-cast terminal box (See note 1.) L - 40 Cap 57 Use wiring terminals that fit M3 screws. G1/2, ground (with 11-inner-dia. rubber bushing built-in) (See note 2.) L - 50 Use wiring terminals that fit M4 screws. Note: 1. The length L is in centimeters, but "40" is 40 millimeters. Therefore, for the E52-P20C, L = 20 (cm), the protective tubing length L - 40 = 200 - 40 = 160 mm. 2. The length L is in centimeters, but "50" is 50 millimeters. Therefore, for the E52-P75C: L = 75 (cm), the protective tubing length L - 50 = 750 - 50 = 700 mm. 3. Terminal box: The permissible temperature is 0C to 80C. Model Information Custom-made models are available on request. Refer to page 4 for details. Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 8 dia. 10 dia. Model Enclosed-terminal Models 20 E52-P20C D=8 --- 35 E52-P35C D=8 E52-P35C D=10 50 E52-P50C D=8 E52-P50C D=10 75 --- E52-P75C D=10 100 --- E52-P100C D=10 Note: The terminals in the cap indicate polarity (A, B, b). 7 E52 Model Number Legend The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below. Thermocouples E52-@@@ D=@@@M@ 1 2 3 4 5 6 7 1. Element type CA: K IC: J PR: R 2. Protective tubing length (L) Specify the length in centimeters in the following range: Unit (cm) 4. Diameter Specify the protective tubing material according to the table. Code Diameter Protective tubing (D) construction Protective tubing material 1 1 mm Sheathed SUS316 1.6 1.6 mm Sheathed SUS316 3.2 3.2 mm Sheathed SUS316 4.8 4.8 mm Sheathed SUS316 2 to 200 6.4 6.4 mm Sheathed SUS316 1.6 3 to 500 8 8 mm Sheathed SUS316 3.2 5 to 2,000 10 10 mm Standard SUS316, SUS310S 8 to 2,300 12 12 mm Standard SUS316, SUS310S 10 to 1,200 15 15 mm Standard SUS316, SUS310S 12 to 1,000 22 22 mm Standard SUS316, SUS310S 17 17 mm Standard PT1, PT0 E52-@@A (Exposed-lead Model) Diameter (D) 1 4.8 6.4 8 Length (L) E52-@@B and E52-@@C (except E52-PR@C) Diameter (D) Length (L) 3.2 11 to 2,000 4.8 14 to 2,300 6.4 16 to 1,200 8.0 18 to 1,000 10 21 to 126 12 24 to 126 15 29 to 156 22 39 to 206 E52-PR@C Diameter (D) 17 5. Heat resistance Specify this item for the exposed-lead models only. Code Temperature range Lead type --- -20C to 70C Sleeve: 0C to 70C Vinyl-covered NETU 0C to 150C Sleeve: 0C to 100C Glass-wool-covered with external shield 6. Lead length (M) Specify the length in meters in the following range for the E52@@A only. Range: 1 to 100 m 7. Protective tubing material Length (L) Code 50, 75, 100 3. Terminal A: Exposed lead wires (element type: K, J) B: Exposed terminals (element type: K, J) C: Enclosed terminals (element type: K, J, R) Protective tubing material Element type --- SUS316 K, J SUS310S SUS310S K, D = 10 to 22 PT1 JIS ceramic Cat.1 R PT0 JIS special ceramic R Examples Element: K; protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m E52-CA42A D=4.8 NETU 10M Element: J; protective tubing length: 360 mm, enclosed terminals, protective tubing dia.: 3.2 E52-IC36C D=3.2 8 E52 Sheathed Thermocouples Specifications Permissible Temperature in Dry Air Element type D K (CA), J(IC) Class Element wire K (CA) SUS316 JIS class 2 (0.75) J (IC) SUS316 Thermal contact Non-grounded type 1 dia. 650C 450C Sheath material CA: SUS316 1.6 dia. 650C 450C IC: SUS316 3.2 dia. 750C 650C 4.8 dia. 800C 750C 6.4 dia. 800C 750C 8.0 dia. 900C 750C Note: For details on the permissible temperature, refer to page D-5 of Introduction of Temperature Controllers (Cat. No. H900). Exposed-lead Models E52-CA@A Dimensions SUS304 sleeve (See note 2.) Y-type crimp terminal for M4 Unit (mm) SUS316 sheath Permissible Temperature in Dry Air d l 1 dia. 7 40 1.6 dia. 7 40 1 dia. 650C 3.2 dia. 7 40 1.6 dia. 650C 4.8 dia. Note: 1. Lead Wire (Compensating Conductor) * Standard (-20C to 70C): 6.4 dia. Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm 8 dia. thick) and external dimensions of 3.2 x 5.0. * Heat Resistive (0C to 150C): Fully glass-wool-covered with seven 0.3-dia. conductors (0.5 mm thick) with external shield of stainless steel and external dimensions of 2.9 x 4.6 The heat-resistive lead wires cannot be used in locations exposed to water or other liquids. * Lead Wire Length (M): 1, 2, 4, or 8 m 2. The sleeve resists temperatures ranging between -20C and 70C for standard models and 0C and 100C for heat-resistive models. 7 40 3.2 dia. 750C 10 45 4.8 dia. 800C 10 45 6.4 dia. 800C 8.0 dia. 900C Red (+) Lead wire (See note 1.) d D D White (-) M L D Element wire K (CA) SUS316 K (CA) Model Information (E52-CA@A) Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details. Terminal type Protective Protective tubing diameter tubing length L D (mm) (cm) Lead wire type Lead wire length M (m) 1 2 4 8 Model Exposed-lead Models 1 dia. 15 20 35 1.6 dia. 15 20 35 Standard E52-CA15A D=1 1M E52-CA15A D=1 2M E52-CA15A D=1 4M E52-CA15A D=1 8M Heat resistive E52-CA15A D=1 NETU 1M E52-CA15A D=1 NETU 2M E52-CA15A D=1 NETU 4M E52-CA15A D=1 NETU 8M Standard E52-CA20A D=1 1M E52-CA20A D=1 2M E52-CA20A D=1 4M E52-CA20A D=1 8M Heat resistive E52-CA20A D=1 NETU 1M E52-CA20A D=1 NETU 2M E52-CA20A D=1 NETU 4M E52-CA20A D=1 NETU 8M Standard E52-CA35A D=1 1M E52-CA35A D=1 2M E52-CA35A D=1 4M E52-CA35A D=1 8M Heat resistive E52-CA35A D=1 NETU 1M E52-CA35A D=1 NETU 2M E52-CA35A D=1 NETU 4M E52-CA35A D=1 NETU 8M Standard E52-CA15A D=1.6 1M E52-CA15A D=1.6 2M E52-CA15A D=1.6 4M E52-CA15A D=1.6 8M Heat resistive E52-CA15A D=1.6 NETU 1M E52-CA15A D=1.6 NETU 2M E52-CA15A D=1.6 NETU 4M E52-CA15A D=1.6 NETU 8M Standard E52-CA20A D=1.6 1M E52-CA20A D=1.6 2M E52-CA20A D=1.6 4M E52-CA20A D=1.6 8M Heat resistive E52-CA20A D=1.6 NETU 1M E52-CA20A D=1.6 NETU 2M E52-CA20A D=1.6 NETU 4M E52-CA20A D=1.6 NETU 8M Standard E52-CA35A D=1.6 1M E52-CA35A D=1.6 2M E52-CA35A D=1.6 4M E52-CA35A D=1.6 8M Heat resistive E52-CA35A D=1.6 NETU 1M E52-CA35A D=1.6 NETU 2M E52-CA35A D=1.6 NETU 4M E52-CA35A D=1.6 NETU 8M 9 E52 Terminal type Protective Protective tubing diameter tubing length L D (mm) (cm) Lead wire type Lead wire length M (m) 1 2 4 8 Model Exposed-lead Models 3.2 dia. 15 20 35 50 4.8 dia. 20 35 50 6.4 dia. 20 35 50 8 dia. 20 35 50 Standard E52-CA15A D=3.2 1M E52-CA15A D=3.2 2M E52-CA15A D=3.2 4M E52-CA15A D=3.2 8M Heat resistive E52-CA15A D=3.2 NETU 1M E52-CA15A D=3.2 NETU 2M E52-CA15A D=3.2 NETU 4M E52-CA15A D=3.2 NETU 8M Standard E52-CA20A D=3.2 1M E52-CA20A D=3.2 2M E52-CA20A D=3.2 4M E52-CA20A D=3.2 8M Heat resistive E52-CA20A D=3.2 NETU 1M E52-CA20A D=3.2 NETU 2M E52-CA20A D=3.2 NETU 4M E52-CA20A D=3.2 NETU 8M Standard E52-CA35A D=3.2 1M E52-CA35A D=3.2 2M E52-CA35A D=3.2 4M E52-CA35A D=3.2 8M Heat resistive E52-CA35A D=3.2 NETU 1M E52-CA35A D=3.2 NETU 2M E52-CA35A D=3.2 NETU 4M E52-CA35A D=3.2 NETU 8M Standard E52-CA50A D=3.2 1M E52-CA50A D=3.2 2M E52-CA50A D=3.2 4M E52-CA50A D=3.2 8M Heat resistive E52-CA50A D=3.2 NETU 1M E52-CA50A D=3.2 NETU 2M E52-CA50A D=3.2 NETU 4M E52-CA50A D=3.2 NETU 8M Standard E52-CA20A D=4.8 1M E52-CA20A D=4.8 2M E52-CA20A D=4.8 4M E52-CA20A D=4.8 8M Heat resistive E52-CA20A D=4.8 NETU 1M E52-CA20A D=4.8 NETU 2M E52-CA20A D=4.8 NETU 4M E52-CA20A D=4.8 NETU 8M Standard E52-CA35A D=4.8 1M E52-CA35A D=4.8 2M E52-CA35A D=4.8 4M E52-CA35A D=4.8 8M Heat resistive E52-CA35A D=4.8 NETU 1M E52-CA35A D=4.8 NETU 2M E52-CA35A D=4.8 NETU 4M E52-CA35A D=4.8 NETU 8M Standard E52-CA50A D=4.8 1M E52-CA50A D=4.8 2M E52-CA50A D=4.8 4M E52-CA50A D=4.8 8M Heat resistive E52-CA50A D=4.8 NETU 1M E52-CA50A D=4.8 NETU 2M E52-CA50A D=4.8 NETU 4M E52-CA50A D=4.8 NETU 8M Standard E52-CA20A D=6.4 1M E52-CA20A D=6.4 2M E52-CA20A D=6.4 4M E52-CA20A D=6.4 8M Heat resistive E52-CA20A D=6.4 NETU 1M E52-CA20A D=6.4 NETU 2M E52-CA20A D=6.4 NETU 4M E52-CA20A D=6.4 NETU 8M Standard E52-CA35A D=6.4 1M E52-CA35A D=6.4 2M E52-CA35A D=6.4 4M E52-CA35A D=6.4 8M Heat resistive E52-CA35A D=6.4 NETU 1M E52-CA35A D=6.4 NETU 2M E52-CA35A D=6.4 NETU 4M E52-CA35A D=6.4 NETU 8M Standard E52-CA50A D=6.4 1M E52-CA50A D=6.4 2M E52-CA50A D=6.4 4M E52-CA50A D=6.4 8M Heat resistive E52-CA50A D=6.4 NETU 1M E52-CA50A D=6.4 NETU 2M E52-CA50A D=6.4 NETU 4M E52-CA50A D=6.4 NETU 8M Standard E52-CA20A D=8 1M E52-CA20A D=8 2M E52-CA20A D=8 4M E52-CA20A D=8 8M Heat resistive E52-CA20A D=8 NETU 1M E52-CA20A D=8 NETU 2M E52-CA20A D=8 NETU 4M E52-CA20A D=8 NETU 8M Standard E52-CA35A D=8 1M E52-CA35A D=8 2M E52-CA35A D=8 4M E52-CA35A D=8 8M Heat resistive E52-CA35A D=8 NETU 1M E52-CA35A D=8 NETU 2M E52-CA35A D=8 NETU 4M E52-CA35A D=8 NETU 8M Standard E52-CA50A D=8 1M E52-CA50A D=8 2M E52-CA50A D=8 4M E52-CA50A D=8 8M Heat resistive E52-CA50A D=8 NETU 1M E52-CA50A D=8 NETU 2M E52-CA50A D=8 NETU 4M E52-CA50A D=8 NETU 8M 10 E52 Exposed-lead Models E52-IC@A Dimensions Y-type crimp terminal for M4 Red (+) SUS304 sleeve (See note 2.) Lead wire (See note 1.) Unit (mm) SUS316 sheath d White (-) M d l 1 dia. 7 40 1.6 dia. 7 40 1 dia. 450C 3.2 dia. 7 40 1.6 dia. 450C 4.8 dia. 7 40 3.2 dia. 650C 6.4 dia. 10 45 4.8 dia. 750C 8 dia. 10 45 6.4 dia. 750C 8.0 dia. 750C D D L Note: 1. Lead Wire (Compensating Conductor) * Standard (-20C to 70C): Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) and external dimensions of 3.2 x 5.0. * Heat Resistive (0C to 150C): Fully glass-wool-covered with seven 0.3-dia. conductors (0.5 mm thick) with external shield of stainless steel and external dimensions of 2.9 x 4.6 The heat-resistive lead wires cannot be used in locations exposed to water or other liquids. * Lead Wire Length (M): 1, 2, 4, or 8 m 2. The sleeve resists temperatures ranging between -20C and 70C for standard models and 0C and 100C for heat-resistive models. Permissible Temperature in Dry Air D Element wire J (IC) SUS316 J (IC) Model Information (E52-IC@A) Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details Terminal type Protective tubing diameter D (mm) Exposed-lead 1 dia. Models Protective tubing length L (cm) Lead wire length M (m) 1 2 4 8 Model 15 20 35 1.6 dia. Lead wire type 15 20 35 Standard E52-IC15A D=1 1M E52-IC15A D=1 2M E52-IC15A D=1 4M E52-IC15A D=1 8M Heat resistive E52-IC15A D=1 NETU 1M E52-IC15A D=1 NETU 2M E52-IC15A D=1 NETU 4M E52-IC15A D=1 NETU 8M Standard E52-IC20A D=1 1M E52-IC20A D=1 2M E52-IC20A D=1 4M E52-IC20A D=1 8M Heat resistive E52-IC20A D=1 NETU 1M E52-IC20A D=1 NETU 2M E52-IC20A D=1 NETU 4M E52-IC20A D=1 NETU 8M Standard E52-IC35A D=1 1M E52-IC35A D=1 2M E52-IC35A D=1 4M E52-IC35A D=1 8M Heat resistive E52-IC35A D=1 NETU 1M E52-IC35A D=1 NETU 2M E52-IC35A D=1 NETU 4M E52-IC35A D=1 NETU 8M Standard E52-IC15A D=1.6 1M E52-IC15A D=1.6 2M E52-IC15A D=1.6 4M E52-IC15A D=1.6 8M Heat resistive E52-IC15A D=1.6 NETU 1M E52-IC15A D=1.6 NETU 2M E52-IC15A D=1.6 NETU 4M E52-IC15A D=1.6 NETU 8M Standard E52-IC20A D=1.6 1M E52-IC20A D=1.6 2M E52-IC20A D=1.6 4M E52-IC20A D=1.6 8M Heat resistive E52-IC20A D=1.6 NETU 1M E52-IC20A D=1.6 NETU 2M E52-IC20A D=1.6 NETU 4M E52-IC20A D=1.6 NETU 8M Standard E52-IC35A D=1.6 1M E52-IC35A D=1.6 2M E52-IC35A D=1.6 4M E52-IC35A D=1.6 8M Heat resistive E52-IC35A D=1.6 NETU 1M E52-IC35A D=1.6 NETU 2M E52-IC35A D=1.6 NETU 4M E52-IC35A D=1.6 NETU 8M 11 E52 Terminal type Protective tubing diameter D (mm) Exposed-lead 3.2 dia. Models Protective tubing length L (cm) 15 20 35 50 4.8 dia. 20 35 50 6.4 dia. 20 35 50 8 dia. 20 35 50 Lead wire type Lead wire length M (m) 1 2 4 8 Standard E52-IC15A D=3.2 1M Model E52-IC15A D=3.2 E52-IC15A D=3.2 2M 4M Heat resistive E52-IC15A D=3.2 NETU 1M E52-IC15A D=3.2 NETU 2M E52-IC15A D=3.2 NETU 4M E52-IC15A D=3.2 NETU 8M Standard E52-IC20A D=3.2 1M E52-IC20A D=3.2 2M E52-IC20A D=3.2 4M E52-IC20A D=3.2 8M Heat resistive E52-IC20A D=3.2 NETU 1M E52-IC20A D=3.2 NETU 2M E52-IC20A D=3.2 NETU 4M E52-IC20A D=3.2 NETU 8M Standard E52-IC35A D=3.2 1M E52-IC35A D=3.2 2M E52-IC35A D=3.2 4M E52-IC35A D=3.2 8M Heat resistive E52-IC35A D=3.2 NETU 1M E52-IC35A D=3.2 NETU 2M E52-IC35A D=3.2 NETU 4M E52-IC35A D=3.2 NETU 8M Standard E52-IC50A D=3.2 1M E52-IC50A D=3.2 2M E52-IC50A D=3.2 4M E52-IC50A D=3.2 8M Heat resistive E52-IC50A D=3.2 NETU 1M E52-IC50A D=3.2 NETU 2M E52-IC50A D=3.2 NETU 4M E52-IC50A D=3.2 NETU 8M Standard E52-IC20A D=4.8 1M E52-IC20A D=4.8 2M E52-IC20A D=4.8 4M E52-IC20A D=4.8 8M Heat resistive E52-IC20A D=4.8 NETU 1M E52-IC20A D=4.8 NETU 2M E52-IC20A D=4.8 NETU 4M E52-IC20A D=4.8 NETU 8M Standard E52-IC35A D=4.8 1M E52-IC35A D=4.8 2M E52-IC35A D=4.8 4M E52-IC35A D=4.8 8M Heat resistive E52-IC35A D=4.8 NETU 1M E52-IC35A D=4.8 NETU 2M E52-IC35A D=4.8 NETU 4M E52-IC35A D=4.8 NETU 8M Standard E52-IC50A D=4.8 1M E52-IC50A D=4.8 2M E52-IC50A D=4.8 4M E52-IC50A D=4.8 8M Heat resistive E52-IC50A D=4.8 NETU 1M E52-IC50A D=4.8 NETU 2M E52-IC50A D=4.8 NETU 4M E52-IC50A D=4.8 NETU 8M Standard E52-IC20A D=6.4 1M E52-IC20A D=6.4 2M E52-IC20A D=6.4 4M E52-IC20A D=6.4 8M Heat resistive E52-IC20A D=6.4 NETU 1M E52-IC20A D=6.4 NETU 2M E52-IC20A D=6.4 NETU 4M E52-IC20A D=6.4 NETU 8M Standard E52-IC35A D=6.4 1M E52-IC35A D=6.4 2M E52-IC35A D=6.4 4M E52-IC35A D=6.4 8M Heat resistive E52-IC35A D=6.4 NETU 1M E52-IC35A D=6.4 NETU 2M E52-IC35A D=6.4 NETU 4M E52-IC35A D=6.4 NETU 8M Standard E52-IC50A D=6.4 1M E52-IC50A D=6.4 2M E52-IC50A D=6.4 4M E52-IC50A D=6.4 8M Heat resistive E52-IC50A D=6.4 NETU 1M E52-IC50A D=6.4 NETU 2M E52-IC50A D=6.4 NETU 4M E52-IC50A D=6.4 NETU 8M Standard E52-IC20A D=8 1M E52-IC20A D=8 2M E52-IC20A D=8 4M E52-IC20A D=8 8M Heat resistive E52-IC20A D=8 NETU 1M E52-IC20A D=8 NETU 2M E52-IC20A D=8 NETU 4M E52-IC20A D=8 NETU 8M Standard E52-IC35A D=8 1M E52-IC35A D=8 2M E52-IC35A D=8 4M E52-IC35A D=8 8M Heat resistive E52-IC35A D=8 NETU 1M E52-IC35A D=8 NETU 2M E52-IC35A D=8 NETU 4M E52-IC35A D=8 NETU 8M Standard E52-IC50A D=8 1M E52-IC50A D=8 2M E52-IC50A D=8 4M E52-IC50A D=8 8M Heat resistive E52-IC50A D=8 NETU 1M E52-IC50A D=8 NETU 2M E52-IC50A D=8 NETU 4M E52-IC50A D=8 NETU 8M E52-IC15A D=3.2 8M 12 E52 Exposed-terminal Models E52-CA@B E52-IC@B Dimensions Permissible Temperature in Dry Air Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. Aluminum die-cast terminal box 22 dia SUS316 sheath + 45 D - D Element wire K (CA) SUS316 J (IC) SUS316 3.2 dia. 750C 650C 4.8 dia. 800C 750C 6.4 dia. 800C 750C 8.0 dia. 900C 750C Terminal box: The permissible temperature is 0C to 100C. 4 16 Two, M3 40 16 L Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details. Element type Terminal type Protective tubing diameter D (mm) Protective tubing length L (cm) 3.2 dia. 4.8 dia. 6.4 dia. 8 dia. Model K (CA) Exposed-terminal Models J (IC) Exposed-terminal Models 20 E52-CA20B D=3.2 E52-CA20B D=4.8 E52-CA20B D=6.4 --- 35 E52-CA35B D=3.2 E52-CA35B D=4.8 E52-CA35B D=6.4 E52-CA35B D=8 50 E52-CA50B D=3.2 E52-CA50B D=4.8 E52-CA50B D=6.4 E52-CA50B D=8 75 --- E52-CA75B D=4.8 E52-CA75B D=6.4 E52-CA75B D=8 20 E52-IC20B D=3.2 E52-IC20B D=4.8 E52-IC20B D=6.4 --- 35 E52-IC35B D=3.2 E52-IC35B D=4.8 E52-IC35B D=6.4 E52-IC35B D=8 50 E52-IC50B D=3.2 E52-IC50B D=4.8 E52-IC50B D=6.4 E52-IC50B D=8 75 --- E52-IC75B D=4.8 E52-IC75B D=6.4 E52-IC75B D=8 Enclosed-terminal Models E52-CA@C E52-IC@C Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. Permissible Temperature in Dry Air D 34 dia. 57 Element wire K (CA) SUS316 14 dia. SUS316 sheath D 65 4 16 19 Aluminum die-cast terminal box 750C 650C 4.8 dia. 800C 750C 6.4 dia. 800C 750C 8.0 dia. 900C 750C Terminal box: The permissible temperature is 0C to 80C. Cap 35 G3/8, 19 mm between facing sides, 10 inner dia. (with 7-inner-dia. rubber bushing built-in) J (IC) SUS316 3.2 dia. Note: The terminals in the cap indicate polarity (+ or -). L-40 Use wiring terminals that fit M3 screws. Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details. Element type Terminal type Protective tubing diameter D (mm) Protective tubing length L (cm) 3.2 dia. 4.8 dia. 6.4 dia. 8 dia. Model K (CA) J (IC) Enclosed-terminal Models Enclosed-terminal Models 20 E52-CA20C D=3.2 E52-CA20C D=4.8 E52-CA20C D=6.4 --- 35 E52-CA35C D=3.2 E52-CA35C D=4.8 E52-CA35C D=6.4 E52-CA35C D=8 50 E52-CA50C D=3.2 E52-CA50C D=4.8 E52-CA50C D=6.4 E52-CA50C D=8 75 --- E52-CA75C D=4.8 E52-CA75C D=6.4 E52-CA75C D=8 20 E52-IC20C D=3.2 E52-IC20C D=4.8 E52-IC20C D=6.4 --- 35 E52-IC35C D=3.2 E52-IC35C D=4.8 E52-IC35C D=6.4 E52-IC35C D=8 50 E52-IC50C D=3.2 E52-IC50C D=4.8 E52-IC50C D=6.4 E52-IC50C D=8 75 --- E52-IC75C D=4.8 E52-IC75C D=6.4 E52-IC75C D=8 13 E52 Standard Thermocouples Specifications Permissible Temperature in Dry Air (See note.) D Element wire K (CA), J(IC), R Class K (CA), J (IC) JIS class 2 (0.75) Protective tubing material J (IC) SUS316 R, JIS class 2 (0.25) 10 dia. 750C 450C K (CA) SUS316 12 dia. 850C 500C J (IC) 15 dia. 850C 550C 22 dia. 900C 600C SUS316 R (See JIS ceramic cat. 1 (PT1) note.) JIS special ceramic (PT0) Thermal contact Element wire K (CA) SUS316 Non-grounded type Note: Specify PT1 or PT0 if the element is R. Note: For details on the permissible temperature, refer to Technical Guide for Temperature Sensors. D Element wire R 17 dia. 0C to 1,400C Exposed-terminal Models E52-CA@B E52-IC@B Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. Aluminum die-cast terminal box 53 SUS316 protective tubing 10 70 D 22 dia. Two, M3 27 L Terminal box: The permissible temperature is 0C to 100C. Permissible Temperature in Dry Air D Element wire K (CA) SUS316 J (IC) SUS316 10 dia. 750C 450C 12 dia. 850C 500C 15 dia. 850C 550C 22 dia. 900C 600C Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details. Element type Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 10 dia. 12 dia. 15 dia. 22 dia. Model K (CA) J (IC) Exposed-terminal Models Exposed-terminal Models 35 E52-CA35B D=10 E52-CA35B D=12 E52-CA35B D=15 --- 50 E52-CA50B D=10 E52-CA50B D=12 E52-CA50B D=15 E52-CA50B D=22 75 E52-CA75B D=10 E52-CA75B D=12 E52-CA75B D=15 E52-CA75B D=22 100 E52-CA100B D=10 E52-CA100B D=12 E52-CA100B D=15 E52-CA100B D=22 35 E52-IC35B D=10 E52-IC35B D=12 E52-IC35B D=15 --- 50 E52-IC50B D=10 E52-IC50B D=12 E52-IC50B D=15 E52-IC50B D=22 75 E52-IC75B D=10 E52-IC75B D=12 E52-IC75B D=15 E52-IC75B D=22 100 E52-IC100B D=10 E52-IC100B D=12 E52-IC100B D=15 E52-IC100B D=22 14 E52 Enclosed-terminal Models E52-CA@C E52-IC@C Dimensions Permissible Temperature in Dry Air Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. Aluminum die-cast terminal box 98 22 dia. SUS316 protective tubing D 90 D Element wire K (CA) SUS316 J (IC) SUS316 10 dia. 0 to 750C 0 to 450C 12 dia. 0 to 850C 0 to 500C 15 dia. 0 to 850C 0 to 550C 22 dia. 0 to 900C 0 to 600C Terminal box: The permissible temperature is 0C to 80C. 10 Note: The terminals in the cap indicate polarity (+ or -). 40 dia. Cap L-50 57 G1/2, 15-A ground (with 11-inner-dia. rubber bushing built-in) Use wiring terminals that fit M4 screws. Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details Element type Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 10 dia. 12 dia. 15 dia. 22 dia. Model K (CA) J (IC) Enclosed-terminal Models Enclosed-terminal Models 35 E52-CA35C D=10 E52-CA35C D=12 E52-CA35C D=15 --- 50 E52-CA50C D=10 E52-CA50C D=12 E52-CA50C D=15 E52-CA50C D=22 75 E52-CA75C D=10 E52-CA75C D=12 E52-CA75C D=15 E52-CA75C D=22 100 E52-CA100C D=10 E52-CA100C D=12 E52-CA100C D=15 E52-CA100C D=22 35 E52-IC35C D=10 E52-IC35C D=12 E52-IC35C D=15 --- 50 E52-IC50C D=10 E52-IC50C D=12 E52-IC50C D=15 E52-IC50C D=22 75 E52-IC75C D=10 E52-IC75C D=12 E52-IC75C D=15 --- 100 E52-IC100C D=10 E52-IC100C D=12 E52-IC100C D=15 E52-IC100C D=22 15 E52 Enclosed-terminal Models (High-temperature Use) E52-PR@C Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. 98 Permissible Temperature in Dry Air Aluminum die-cast terminal box SUS304 Ceramic protective tubing (t2.0) D Element wire R 17 dia. 90 Bending of protective tubing: 6 mm max. 21.7 dia. 40 dia. Cap 57 100 L-150 G1/2, 15-A ground (with 11-inner-dia. rubber bushing built-in) 17 dia. 0C to 1,400C Terminal box: The permissible temperature is 0C to 80C. Note: The terminals in the cap indicate polarity (+ or -). Use wiring terminals that fit M4 screws. Model Information Element type Terminal type Protective tubing diameter D (mm) Protective tubing length L (cm) 17 dia. Model R (See note 1.) Enclosed-ter- 50 minal Models 75 100 R (See note 2.) Enclosed-ter- 50 minal Models 75 100 Standard E52-PR50C D=17 PT1 E52-PR75C D=17 PT1 E52-PR100C D=17 PT1 E52-PR50C D=17 PT0 E52-PR75C D=17 PT0 E52-PR100C D=17 PT0 Protective tubing material Permissible temperature in dry air Note 1: JIS ceramic Cat.1 (PT1) Mullite, high alumina, etc. 1,500C (See note.) Note 2: JIS special ceramic (PT0) Recrystallized alumina, fused alumina, etc. 1,700C (See note.) Note: The permissible temperature given for the protective tubing is higher than 1,400C, but the permissible temperature of the thermocouple element wire is only 1,400C. Therefore, the protective tubing of the E52-PR@C can withstand high temperatures momentarily to the levels given in the table as exceptions, but the element wire will deteriorate quickly if the thermocouple is used regularly at temperatures that exceed the permissible temperature for the element wire. 16 E52 Low-cost Models Low-cost Platinum Resistance Thermometers Exposed-lead Models with Screws Specifications E52-P6D Element type Pt100 Conductor type 3-conductor system Class Class B Protective tubing material SUS304 Sensor length 30 mm Dimensions 4 dia. Tapered pipe thread Argon arc welding SUS304 R1/8 Silicone tubing SUS304 (t0.25) Caulking Black (B) Max. detectable temperature 250C Temperature range -50C to 250C Lead wire -50C to 150C Fluororesin-covered wire with 1.0 outer dia. each (PFA) 7/0.18 Red (A) 14 65 Y-type crimp terminal for M4 M 30 10 6 15 Black (B) Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Model 1 E52-P6D 1M 2 E52-P6D 2M 4 E52-P6D 4M Exposed-lead Models with Flange Specifications E52-P6F Element wire Pt100 Conductor type 3-conductor system Class Class B Protective tubing material SUS304 Sensor length 30 mm Dimensions Flange 120 SUS304 Three, 3.5 dia. 120 Silicone tubing Caulking SUS304 (t0.25) 4 dia. -50C to 250C Lead wire -50C to 150C Red (A) Black (B) Max. detectable temperature 250C Temperature range Fluororesin-covered wire with 1.0 outer dia. each 1 20 dia. 30 dia. 65 Silver soldering Y-type crimp 30 terminal for M4 M 15 Black (B) Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Model 1 E52-P6F 1M 2 E52-P6F 2M 4 E52-P6F 4M Exposed-lead Models Specifications E52-P10AE Element type Pt100 Conductor type 3-conductor system Class Class B Protective tubing material SUS304 Sensor length 20 mm Dimensions 3.2 dia. SUS304 (t0.25) Silicone shrinkable tubing White (B) Max. detectable temperature 250C Temperature range -50C to 250C Lead wire -50C to 150C Fluororesin-covered wire with 1.0 outer dia. each Caulking (PFA) 7/0.18 Red (A) 30 100 Y-type crimp terminal for M4 M White (B) Note: 1. The protective tubing is of pipe construction, which must not be bent. 2. A Compression Fitting (PT@) cannot be used for mounting. Lead wire length (m) Model 1 E52-P10AE 1M 2 E52-P10AE 2M 4 E52-P10AE 4M 17 E52 Low-cost Thermocouples Exposed-lead Models with Spring E52-CA@AS, E52-IC@AS Specifications Dimensions Element type K (CA), J (IC) Element dia. 0.65 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Thermal contact Non-grounded type Temperature range 0C to 400C: K (CA) 0C to 350C: J (IC) Lead wire 0C to 180C L SUS304 (t0.4) 4.8 dia. 32 12 dia. M 150 80 Red (+) Sleeve Brass-nickel Closely wound plating spring coil Fully glass-wool-covered compensating cable with four 0.65-dia. conductors and external dimensions of approx. 5.1 x 3.0 White (-) Y-type crimp terminal for M4 Color code (K: Blue, J: Yellow) L: Protective tubing length M: Lead wire length Note: The sleeve resists temperatures ranging between 0C and 100C. Note: The protective tubing is of pipe construction, which must not be bent. Protective tubing length (mm) Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 65 100 150 200 1 E52-CA6AS 1M E52-IC6AS 1M 2 E52-CA6AS 2M E52-IC6AS 2M 4 E52-CA6AS 4M E52-IC6AS 4M 1 E52-CA10AS 1M E52-IC10AS 1M 2 E52-CA10AS 2M E52-IC10AS 2M 4 E52-CA10AS 4M E52-IC10AS 4M 1 E52-CA15AS 1M E52-IC15AS 1M 2 E52-CA15AS 2M E52-IC15AS 2M 4 E52-CA15AS 4M E52-IC15AS 4M 1 E52-CA20AS 1M E52-IC20AS 1M 2 E52-CA20AS 2M E52-IC20AS 2M 4 E52-CA20AS 4M E52-IC20AS 4M 18 E52 Exposed-lead Models with Screw E52-CA1D, E52-IC1D Specifications Dimensions Element type K (CA), J (IC) Element dia. 0.65 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Thermal contact Grounded type Temperature range 0C to 400C: K (CA) 0C to 350C: J (IC) Lead wire 0C to 180C 0.65-dia. 2.8 thermocouple element B 3.8 dia. Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. Specify the type of screw (i.e., M6, M8, or W1/4) when ordering. 3. The thermocouple is not of airtight construction. 4. OMRON recommends that the tip of the thermocouple is touching the sensing object. Movable ring (brass) 1 10 A C M Color tubing Brass (K: Blue, J: Yellow) 5 dia. SUS304 screw (W1/4) Enamel-bonded copper wire 80 White (-) Color code (K: Blue, Crimp terminal for M4 J: Yellow) Covered with black insulation tubing Fully glass-wool-covered with external copper shield and external dimensions of approx. 3.1 x 2.0 Internal Construction (E52-CA1D) 0.65-dia. black wire Movable ring Brass Red (+) Closely wound enamel-bonded coil. Lead wire length (m) Screw W1/4 M6 M8 A (mm) 5 4 5.3 B (mm) 11.5 11 14 C (mm) 3 4 2.5 Installation Example Cut a thread into the workpiece, and screw in the thermocouple while pushing in so that the tip makes complete contact. End Cut after silver soldering M6 Brass pipe Screw Shielded glass-wool lead wire Workpiece Note: E52-CA1D with the same shape and multiple element wires are also available (E52-CA1D-40). Refer to page 27 for details. Protective tubing length (mm) Lead wire length (m) Element type: K (CA) Element type: J (IC) Model M6 screw M8 screw W1/4 screw 1 E52-CA1D M6 1M E52-IC1D M6 1M 2 E52-CA1D M6 2M E52-IC1D M6 2M 4 E52-CA1D M6 4M E52-IC1D M6 4M 1 E52-CA1D M8 1M E52-IC1D M8 1M 2 E52-CA1D M8 2M E52-IC1D M8 2M 4 E52-CA1D M8 4M E52-IC1D M8 4M 1 E52-CA1D W1/4 1M E52-IC1D W1/4 1M 2 E52-CA1D W1/4 2M E52-IC1D W1/4 2M 4 E52-CA1D W1/4 4M E52-IC1D W1/4 4M 19 E52 Exposed-lead Models with Flange Specifications E52-CA6F, E52-IC6F Element type K (CA), J (IC) Dimensions Element diameter 0.65 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Fully glass-wool-covered tubing with external dimensions of 3.6 x 2.2 (CA) and 3.8 x 2.4 (IC) Three, 3.5 dia. 120 120 SUS304 Silver soldering Silicone tubing Solder processed SUS304 White/red stripe (+) White (-) Thermal contact Grounded type Temperature range 0C to 350C: K (CA) 0C to 350C: J (IC) Lead wire 0C to 150C Color code (K: Blue, J: Yellow) M 4 dia. 1 20 dia. 30 dia. 30 65 15 80 10 Lead wire length (M): 1, 2, or 4 m Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. The tip is processed with solder, which ensures ease of welding. 3. The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 1 E52-CA6F 1M E52-IC6F 1M 2 E52-CA6F 2M E52-IC6F 2M 4 E52-CA6F 4M E52-IC6F 4M Exposed-lead Models with Screws Specifications E52-CA6D, E52-IC6D Element type K (CA), J (IC) Dimensions Element diameter 0.65 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Fully glass-wool-covered tubing with external dimensions of 3.6 x 2.2 (CA) and 3.8 x 2.4 (IC) Tapered pipe thread Argon arc welding SUS304 Solder processed R1/8 SUS304 Silicone tubing White/red stripe (+) White (-) Thermal contact Grounded type Temperature range Lead wire 0C to 350C: K (CA) 0C to 350C: J (IC) 0C to 150C 4 dia. 14 80 10 30 10 6 65 15 M Color code (K: Blue, J: Yellow) Lead wire length (M): 1, 2, or 4 m Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. The tip is processed with solder, which ensures ease of welding. 3. The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 1 E52-CA6D 1M E52-IC6D 1M 2 E52-CA6D 2M E52-IC6D 2M 4 E52-CA6D 4M E52-IC6D 4M 20 E52 Exposed-lead Models Specifications E52-CA10AE, E52-IC10AE Element type K (CA), J (IC) Dimensions Element diameter 0.32 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 SUS304 3.2 dia. Caulking 2.8-max. outer-dia. fully glass-woolcovered tubing White/red stripe (+) White (-) 80 Thermal contact Non-grounded type Temperature range 0C to 350C: K (CA) 0C to 200C: J (IC) Lead wire 0C to 180C M 100 Color code (K: Blue, J: Yellow) Note: 1. 2. 3. 4. The thermocouple is a single wire from the tip to the terminal. Lead wire length M: 1, 2, or 4 m The protective tubing is of pipe construction, which must not be bent. The thermocouple cannot be mounted using a PT@ Compression Fitting. Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 1 E52-CA10AE 1M E52-IC10AE 1M 2 E52-CA10AE 2M E52-IC10AE 2M 4 E52-CA10AE 4M E52-IC10AE 4M Exclusive Models Thermocouples Thermocouples for Molding Machines Specifications E52-CA2GV, E52-IC2GV Element type K (CA), J (IC) Dimensions Element diameter 1.0 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 11-dia. spring metal fitting Closely wound spring coil Bayonet 4.8 dia. SUS304 6.8 dia. M3 screw Thermal contact Grounded type Temperature range 0C to 350C Lead wire 0C to 180C 25 15 22 105 Adapter (provided) 4.1-outer-dia. glass-wool-covered cable with external shield K (CA) White/red stripe (+) White/blue stripe (-) White stripe (-) Color code Y-type crimp (K: Blue, J: Yellow) terminal for M4 Element type: K (CA) 12 dia. 10 15 25 Brass-nickel plating M Lead wire length (M): 1 or 2 m Lead wire length (m) R1/8 J (IC) White/red stripe (+) Element type: J (IC) Model 1 E52-CA2GV 1M E52-IC2GV 1M 2 E52-CA2GV 2M E52-IC2GV 2M 21 E52 Thermocouples with Crimp Terminals Specifications E52-CA1GT, E52-IC1GT Element type K (CA), J (IC) Dimensions Element diameter 0.65 mm (single wire) Class Class 2 (0.75) M4, round crimp terminal 6.5 Silicone tubing Glass-wool-braided shield with maximum external dimensions of 4.2 dia. (CA) and K (CA) J (IC) 5.2 dia. (IC) White/red stripe (+) White/red stripe (+) Thermal contact Grounded type Temperature range 0C to 300C Lead wire 0C to 150C Note: The E52-CA1GT is also available with double elements. Refer to page 23 for details. 4.4 dia. 15 White stripe (-) Color code (K: Blue, J: Yellow) 6 dia. max. Y-type crimp terminal for M4 M Lead wire length (M): 1 or 2 m Lead wire length (m) White/yellow stripe (-) 80 Element type: K (CA) Element type: J (IC) Model 1 E52-CA1GT 1M E52-IC1GT 1M 2 E52-CA1GT 2M E52-IC1GT 2M Platinum Resistance Thermometers Platinum Resistance Thermometers for Surface Temperature Measurement Specifications E52-P2GS Dimensions Element type Pt100 Class Class B Protective tubing material SUS304 With brass-nickel-plated bracket Conductor type 3-conductor system Temperature range -50C to 250C Lead wire -50C to 150C Silicone-covered 3-conductor cable Brass-nickel-plated bracket with twelve 0.18-dia. conductors (0.3-mm thick) Four, 3.2 dia. 6-dia. SUS304 and approx. 4.8 dia. sleeve Press Red (A) 20 14 5 White (B) 50 20 28 Approx. 32 Silicone tubing (8-dia.) M Black (B) 80 Y-type crimp terminal for M4 6 Lead wire length (M): 1 or 2 m 1.5 Lead wire length (m) Model 1 E52-P2GS 1M 2 E52-P2GS 2M Platinum Resistance Thermometers for Room Temperature Measurement Specifications E52-P10GR Element type Pt100 Class Class B Protective tubing material SUS304 Conductor type 3-conductor system 15 Temperature range -50C to 60C Lead wire Dimensions 92 Aluminum alloy 6.7-outer-dia. vinyl-covered 3-conductor 65 dia. cable (twenty 0.18-dia. conductors, 0.5 mm thick) SUS304 8 dia. Red (A) White (B) 78 20 dia. -20C to 70C Black (B) Y-type crimp terminal for M4 80 97 100 2,000 55 Brass-nickel-plated protective pipe Lead wire length (m) 2 6 dia. G1/2 Model E52-P10GR 2M 22 E52 Double-element Platinum Resistance Thermometers Specifications E52-P20GW Element type Pt100 Class Class B Protective tubing material SUS304 Polyamide-insulated tubing with 0.5-dia. Ag lead wire Conductor type Double-element, 3conductor system Resistance thermometer element Temperature range -50C to 250C Lead wire -20C to 70C Dimensions Round press with hexagonal caulking Silicone shrinkable tubing M3.5, round crimp terminal Tubing with terminal number 8.2 dia. Red (A1) Black (B1) White (B1) 10 dia. 3.2 dia. Brown (A2) Filled with silicone Yellow (B2) Fluororesin tubing 200 Green (B2) 70 Lead wire length (M): 1 or 2 m M 80 Fully vinyl-covered lead cable with twenty 0.18-dia. conductors (0.5 mm thick) Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Model 1 E52-P20GW 1M 2 E52-P20GW 2M Waterproof Platinum Resistance Thermometers Specifications E52-P10GP Element wire Pt100 Class Class B Protective tubing material SUS304 Conductor type 3-conductor system Temperature range 0C to 70C (underwater) -20C to 70C (in the air) Lead wire 0C to 70C Dimensions Y-type crimp 7.2-outer-dia. vinyl-covered 3-conductor cable (thirty 0.18-dia. terminal for M4 conductors, 0.75 mm thick) Red (A) 20 dia. 7 dia. White (B) Black (B) 100 62 5 M Lead wire length (M): 2 or 4 m Note: The lead wires are vinyl-covered, and cannot be used underwater. Use the E52P5A-40 if waterproof lead wires are required for use underwater. Refer to page 24 for details. Lead wire length (m) Model 2 E52-P10GP 2M 4 E52-P10GP 4M 23 E52 Corrosion-resistant Models with Fluororesin-covered Protective Tubing Thermocouples Exposed-lead Models Specifications E52-CA20A-1 Element type K (CA) Class Class 2 (0.75) Protective tubing material SUS316 with Fluororesin-covered (FEP) tube Thermal contact Non-grounded type Temperature range 0C to 180C Lead wire Vinyl-covered: -20C to 70C Dimensions Y-type crimp Araldite resin terminal for M4 Compensating conductor Red (+) Fixed with adhesive tape and silicone heat-shrinking tube d Sleeve Sheath D White (-) FEP-covered tubing 2,000 Model 40 Protective tubing diameter E52-CA20A-1 D=4.6 2M D = 4.6 E52-CA20A-1 D=6 2M D = 6.0 E52-CA20A-1 D=8 2M D = 8.0 200 Lead wire length (m) Sleeve diameter Covering thickness (mm) (mm) Sleeve length (mm) d=7 l = 40 0.7 2 0.6 d = 10 l = 45 0.8 Platinum Measurement Exposed-lead Models Specifications E52-P20A-1 Element type Pt100 Class Class B Protective tubing material SUS316 with Fluororesin-covered (FEP) tube Conductor type 3-conductor system Temperature range -80C to 180C Lead wire Vinyl-covered: -20C to 70C Dimensions Y-type crimp terminal for M4 Araldite resin Fixed with adhesive tape and silicone heat-shrinking tube d Sleeve Lead wires Red (A) Sheath D White (B) Black (B) FEP-covered tubing 2,000 Model 200 60 Lead wire length (m) Coating thickness (mm) Sleeve diameter (mm) Protective tubing diameter E52-P20A-1 D=4.6 2M D = 4.6 d=8 0.7 E52-P20A-1 D=6 2M D = 6.0 d=8 0.6 E52-P20A-1 D=8 2M D = 8.0 d=8 0.8 2 FEP-molded Models (Completely Waterproof) Specifications E52-P5A-40 Element type Pt100 Class Class B Protective tubing material Fluororesin-molded (FEP) covering Conductor type 3-conductor system Temperature range -50C to 180C Lead wire Fluororesin-covered (PFA): -50C to 180C Dimensions FEP mold 7 dia. PFA-covered wire 7/0.18 Red (A) White (B) 10 7 3 White (B) 40 Y-type crimp terminal for M4 65 M Model Protective tubing diameter Lead wire length (m) E52-P5A-40 2M D = 10 (elliptical) 2 E52-P5A-40 4M D = 10 (elliptical) 4 E52-P5A-40 6M D = 10 (elliptical) 6 E52-P5A-40 8M D = 10 (elliptical) 8 24 E52 Pressure-resistant Explosion-proof (d2G4) Models Thermocouples Enclosed-terminal Models Specifications E52-CA@@C-6 Element type K (CA) Class Class 2 (0.75) Protective tubing material L2 section: SUS316 L1 section: SUS304 Operating temperature range (in dry air) Sensor: -100C to 900C Terminal: 0C to 70C Dimensions L L2 Metal conduit connected with screws to terminal box Conduit thread PF1/2 Installation method Conforms to Technical Recommendations of the Research Institute of Industrial Safety (Japan) Hexagonal slot, 22 between flats SUS316 15 dia. 6.4 dia. 84 dia. Explosion- Construction Pressure-resistant proof explosion-proof structure specifica- Explosiond2G4 tions protected class and ignitability Lead wire wiring method 115 L1 SUS304 18 77 Model PF1/2 Protective tubing length L (cm) Protective tubing diameter L2 (mm) E52-CA20C-6 D=6.4 L2=150 20 D = 6.4 150 E52-CA35C-6 D=6.4 L2=300 35 D = 6.4 300 E52-CA50C-6 D=6.4 L2=450 50 D = 6.4 450 E52-CA75C-6 D=6.4 L2=700 75 D = 6.4 700 Platinum Resistance Thermometers for Surface Temperature Measurement Enclosed-terminal Models Specifications E52-P@@C-6 Element type Pt100 Class Class B Protective tubing material L2 section: SUS316 L1 section: SUS304 Operating temperature range (in dry air) Sensor: -100C to 500C Terminal: 0C to 70C Explosion- Construction Pressure-resistant proof explosion-proof structure specifica- Explosiond2G4 tions protected class and ignitability Lead wire wiring method Metal conduit connected with screws to terminal box Conduit thread PF1/2 Installation method Conforms to Technical Recommendations of the Research Institute of Industrial Safety (Japan) Dimensions L L2 115 Hexagonal slot, 22 between flats L1 SUS316 15 dia. 6.4 dia. 84 dia. SUS304 18 77 Model Protective tubing length L (cm) PF1/2 Protective tubing diameter L2 (mm) E52-P20C-6 D=6.4 L2=150 20 D = 6.4 150 E52-P35C-6 D=6.4 L2=300 35 D = 6.4 300 E52-P50C-6 D=6.4 L2=450 50 D = 6.4 450 E52-P75C-6 D=6.4 L2=700 75 D = 6.4 700 25 E52 Double-element Models Thermocouple Exposed-lead Models Specifications E52-CA20A-7 Element type K (CA) Class Class 2 (0.75) Protective tubing material SUS316 (with sheath) Thermal contact Non-grounded type Temperature range 0C to permissible temperature limit Lead wire Vinyl-covered: -20C to 70C Dimensions Compensating conductor Red (+) d Sleeve Protective tubing D White (-) Red (+) White (-) 80 2,000 200 45 Permissible Temperature in Dry Air D Element wire K (CA) SUS316 3.2 dia. 750C 4.8 dia. 800C 6.4 dia. 850C 8.0 dia. 900C Model Protective tubing diameter Sleeve diameter (mm) Permissible Lead wire Temperature length (m) (C) E52-CA20A-7 D=3.2 2M D = 3.2 d = 10 750 2 E52-CA20A-7 D=4.8 2M D = 4.8 d = 10 800 2 E52-CA20A-7 D=6.4 2M D = 6.4 d = 10 800 2 E52-CA20A-7 D=8.0 2M D = 8.0 d = 10 900 2 Platinum Resistance Thermometers Exposed-lead Models Specifications E52-P20A-7 Element type Pt100 Class Class B Protective tubing material SUS316 (with sheath) Conductor type 3-conductor system Black (B1) Temperature range -200C to 450C White (B1) Lead wire Vinyl-covered: -20C to 70C Dimensions Y-type crimp terminal for M4 Red (A1) Lead wires Sleeve (SUS304) Caulking Protective tubing (SUS316) D Brown (A2) Yellow (B2) Araldite resin Green (B2) 80 Model 2,000 70 200 Protective tubing diameter Lead wire length (m) E52-P20A-7 D=4.8 2M D = 4.8 2 E52-P20A-7 D=6.4 2M D = 6.4 2 26 E52 Enclosed-terminal Models Specifications E52-P20C-7 Element type Pt100 Class Class B Protective tubing material SUS316 (with sheath) Conductor type 3-conductor system Temperature range -200C to 450C Dimensions 98 40 dia. 80 dia. Terminal box Protective tubing D 57 150 Model Protective tubing Protective length L (cm) tubing diameter E52-P20C-7 D=4.8 20 D = 4.8 E52-P20C-7 D=6.4 20 D = 6.4 Silicone-covered Lead Wires Models Thermocouples Exposed-lead Models with Screws Specifications E52-CA1D-40 Element type K (CA) Class Class 2 (0.75) Screw material SUS304 Thermal contact Grounded type Temperature range 0C to 300C Lead wire Silicone-covered (0.1/30): 0C to 150C Dimensions 1 2.8 10 4.2 M 13 80 Silicone covering 80 Red (+) 11 3.8 dia. 8 dia. Caulking Thermocouple SUS304 screw element wire Movable ring Note: Refer to the installation example for the E52-CA1D. Model White (-) SUS304 Silicone spring with covering Crimp terminal 6.5 outer dia. for M4 and 5.2 Silicone inside dia. shrinkable tubing Screw pitch Lead wire length (m) E52-CA1D-40 M6 1M M6 1 E52-CA1D-40 M6 2M M6 2 E52-CA1D-40 M6 4M M6 4 Thermocouples with Crimp Terminals Specifications E52-CA1GT-14 Element type K (CA) Dimensions Class Class 2 (0.75) Thermal contact Grounded type Temperature range 0C to 300C Silicone-covered M4, round, compensating cable with crimp terminal thirty 0.1-dia. conductors and external dimensions 6.5 of 3.5 x 4.9 Lead wire Silicone-covered (0.1/30): 0C to 150C Color tubing Blue CA (K) Red (+) White (-) 15 30 80 M Crimp terminal for M4 Lead wire length (M): 1 or 2 m Model Lead wire length (m) E52-CA1GT-14 1M 1 E52-CA1GT-14 2M 2 27 E52 Thermistors Element Interchangeable Thermistor for E5CS and E5C2 Temperature Ranges Temperature range Color code Nominal resistance Thermistor constant -50C to 50C Blue 6 k (0C) 3390K 0C to 100C Black 6 k (0C) 3390K 50C to 150C Red 30 k (0C) 3450K 100C to 200C Yellow 0.55 k (200C) 4300K 150C to 300C Green 4 k (200C) 5133K Lead wire A pair of 0.12 dia. 7 Fluororesin-insulated stranded wires with 0.86 outer dia. each Flat glass-wool-shielded lead cable with 0.12 dia. 10 conductors and external dimensions of 2.5 x 1.55 Specifications Item Coupling method E52-THE@@ Element interchangeable thermistor Class JIS class 1 Protective tubing material SUS304 Time constant 8 to 15 s in still water Dissipation factor 2.4 to 2.8 mW/C in still air Lead wire heat resistive temperature 180C Error Detectable temperature Error -50C to 100C 1C max. 100C to 350C 1% max. of detectable temperature Permissible Temperature Detectable temperature Operating temperature -50C to 50C 100C 0C to 100C 150C 50C to 150C 200C 100C to 200C 250C 150C to 300C 350C Note: Models with non-standard lead wire length and protective tubing length are available on request. This Thermistor is a dedicated Thermistor for the E5C2 and E5CS. 28 E52 Exposed-lead Models E52-THE5A Note: The lead wires have no polarity Dimensions Temperature range SUS304 t0.25 Lead wires (See note.) Caulking Color code 4 dia. 15 50 50 10 1,030 Model -50C to 50C E52-THE5A -50-50C 1M 0C to 100C E52-THE5A 0-100C 1M 50C to 150C E52-THE5A 50-150C 1M 100C to 200C E52-THE5A 100-200C 1M 150C to 300C E52-THE5A 150-300C 1M Exposed-lead Models with Screws E52-THE6D Temperature range Dimensions -50C to 50C Tapered pipe thread SUS304 Lead wires R1/8 (See note.) SUS304 t0.25 Color code 4 dia. Argon arc welding 15 10 6 14 65 15 Model E52-THE6D -50-50C 1M 0C to 100C E52-THE6D 0-100C 1M 50C to 150C E52-THE6D 50-150C 1M 100C to 200C E52-THE6D 100-200C 1M 150C to 300C E52-THE6D 150-300C 1M 50 10 1,000 Note: The lead wires have no polarity Exposed-lead Models with Flange E52-THE6F Temperature range Dimensions -50C to 50C Three, 3.5 dia. 120 120 SUS304 SUS304 t0.25 Silver soldering Lead wires (See note.) Color code 4 dia. 15 1 20 dia. 30 dia. 65 15 Model E52-THE6F -50-50C 1M 0C to 100C E52-THE6F 0-100C 1M 50C to 150C E52-THE6F 50-150C 1M 100C to 200C E52-THE6F 100-200C 1M 150C to 300C E52-THE6F 150-300C 1M 50 10 1,000 Note: The lead wires have no polarity Note: 1. The Thermistor lead cable can be extended with a standard lead wire for extension. If waterproof performance is required, be sure that the lead cable joint is of waterproof construction as well. 2. Be sure to specify the model and temperature range when ordering the Thermistor. The Thermistor has a color code according to the temperature range. 29 E52 Accessories Compression Fittings Model Information Model Screw of part Applicable a protective tubing diameter PT 1/8 D=1.0 R 1/8 Dimension b 1.0 dia. PT 1/8 D=1.6 1.6 dia. PT 1/8 D=3.2 3.2 dia. PT 1/8 D=4.8 c d Flat diameter Part c Part b 5 13 10 14 14 5 15 12 17 14 17 4.8 dia. PT 1/4 D=3.2 R 1/4 3.2 dia. PT 1/4 D=4.8 4.8 dia. PT 1/4 D=6.4 6.4 dia. PT 3/8 D=8 R 3/8 8 dia. 5 19 15 21 PT 1/2 D=10 R 1/2 10 dia. 8 23.5 19.5 26 21 M 12 D=4.8 M 12 4.8 dia. 5 15 12 17 14 Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the sensing object will cause problems. The compression fitting is a screw that adjusts and secures the insertion length of Temperature Sensors with the above protective tubing diameters. The material of the Compression Fitting is SUS304 with internal fixing beads made of brass. a Protective tubing dia. D Sensor side Head side d c b Tighten using the retaining screw to secure to the protective tubing. Material Main body SUS304 Lock bead Brass Retaining screw SUS304 Source: JIS B 0203 (Unit: mm) Nominal thread size Outer T.P.I. (No. of diamethreads ter: d /inch) Root diameter: d1 Effective diameter: d2 Standard diameter position a (from pipe end) Minimum effective screw length: f PT 1/8 28 9.728 9.147 8.566 3.97 0.91 2.5 PT 1/4 19 13.157 12.301 11.445 6.01 1.34 3.7 PT 3/8 19 16.662 15.806 14.950 6.35 1.34 3.7 PT 1/2 14 20.955 19.793 18.631 8.16 1.81 5.0 a f Tapered thread d d2 d1 Standard dia. 30 E52 Loose Flanges Model Information Applicable protective tubing diameter MF-1 Model 3.2 dia. MF-1 D=3.2 4.8 dia. MF-1 D=4.8 6.4 dia. MF-1 D=6.4 8 dia. MF-1 D=8 10 dia. MF-2 D=10 12 dia. MF-2 D=12 15 dia. MF-2 D=15 22 dia. MF-2 D=22 Note: 1. Use the Loose Flange in atmospheric pressure. The Loose Flange is not of airtight construction. 2. Use the Loose Flange at 400C maximum. 3. Do not apply the Loose Flange to protective tubing diameters other than the applicable ones. MF-2 120 120 Three, 5 dia. Three, 6.5 dia. 36 54 dia. 21 dia. D dia. M4 31 dia. D dia. 5 14 24 23 dia. 45 dia. M6 6.6 35 dia. 70 dia. Material: Aluminum 31 E52 Compensating Conductors The material of the Compensating Conductor is the same as or similar to that of the Thermocouple. Therefore, the Thermocouple can be connected to the Compensating Conductor just as if the length of the Thermocouple is to be extended. A standard model for a temperature range between -20C and 70C and two types of heat-resistive models for a temperature range between 0C and 150C are available. Be sure to use the compensating conductor for the extension of the length of the thermocouple. Model Information Thermocouple R Heat resistance Standard Heat resistive K (CA) Exterior Model (Length) 1m Fully vinyl-covered (waterproof) WPRG 1M Fully glass-wool-covered WPRH 1M WPRG 2M 4m 8m WPRG 4M WPRG 8M WPRH 2M WPRH 4M WPRH 8M Fully glass-wool-covered with external shield of WPRH6 1M stainless steel WPRH6 2M WPRH6 4M WPRH6 8M Standard Fully vinyl-covered (waterproof) WCAG 1M WCAG 2M WCAG 4M WCAG 8M Heat resistive Fully glass-wool-covered WCAH 1M WCAH 2M WCAH 4M WCAH 8M WCAH6 2M WCAH6 4M WCAH6 8M Fully glass-wool-covered with external shield of WCAH6 1M stainless steel J (IC) 2m Silicone-covered (See note 2.) WCAG-40 1M WCAG-40 2M WCAG-40 4M WCAG-40 8M Standard Vinyl covered (waterproof) WICG 1M WICG 2M WICG 4M Heat resistive Fully glass-wool-covered WICH 1M WICH 2M WICH 4M WICH 8M WICH6 2M WICH6 4M WICH6 8M Fully glass-wool-covered with external shield of WICH6 1M stainless steel WICG 8M Note: 1. Compensating Conductors with lengths, increased in units of a meter, up to 100 meters are available on request. Specify lengths above 100 meters in units of 100 meters. The maximum length depends on the product. Contact your OMRON representative for details. 2. It has the same waterproof characteristics as the standard model (fully vinyl-covered) and can be used at high temperatures. Specifications (JIS C1610-1981) Model WPRG Type of thermocouple R WPRH Use Code Standard Heat resis- RX-H tive WPRH6 WCAG K (CA) WCAH Standard WICH WICH6 J (IC) Operating temperature range (C) Fully vinyl-covered (waterproof) 4/0.65 0 to 70 Fully glass-wool-covered 7/0.3 0 to 150 Error (C) +3/-7 Exterior color Black Resistance of both lines (/m) 0.055 0.140 Fully glass-wool-covered with external shield of stainless steel VX-G Fully vinyl-covered (waterproof) 4/0.65 -20 to 70 2.5 Fully glass-wool-covered 7/0.3 0 to 150 3.0 1.07 4.18 WX-H6 WCAG-40 Number of wires/wire diameter RX-H6 Heat resis- WX-H tive WCAH6 WICG RX-G Exterior Silicone-covered 30/0.1 -20 to 150 2.5 Standard Fully vinyl-covered (waterproof) 4/0.65 -20 to 70 2.5 Fully glass-wool-covered 7/0.3 0 to 150 Heat resis- JX-H tive JX-H6 0.39 Fully glass-wool-covered with external shield of stainless steel Heat resis- KX-G tive for moving parts JX-G Blue Yellow 0.47 1.27 Fully glass-wool-covered with external shield of stainless steel ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 32 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2012.8 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2012 All Right Reserved.