SPECIFICATION
RSP-320-4RSP-320-3.3 RSP-320-5 RSP-320-7.5 RSP-320-12RSP-320-2.5
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.) Note.2
OUTPUT VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
SAFETY &
EMC
(Note 5)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
PROTECTION
4V3.3V 5V 7.5V 12V2.5V
60A60A 60A 40A 26.7A60A
0 ~ 60A0 ~ 60A 0 ~ 60A 0 ~ 40A 0 ~ 26.7A0 ~ 60A
240W198W 300W 300W 320.4W150W
100mVp-p100mVp-p 150mVp-p 150mVp-p 150mVp-p100mVp-p
2.35 ~ 2.85V 3.7 ~ 4.3V2.97 ~ 3.8V 4.5 ~ 5.5V 6 ~ 9V 10 ~ 13.2V
±2.0%±2.0% ±2.0% ±2.0% ±1.0%±2.0%
±0.5%±0.5% ±0.5% ±0.5% ±0.3%±0.5%
±1.0%±1.5% ±1.0% ±1.0% ±0.5%±1.5%
1500ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load
8ms at full load 230VAC /115VAC
88 ~ 264VAC 124 ~ 370VDC
47 ~ 63Hz
PF>0.95/230VAC PF>0.98/115VAC at full load
79.5% 81% 83% 88% 88%75.5%
20A/115VAC 40A/230VAC
<1mA / 240VAC
105 ~ 135% rated output power
3.8 ~ 4.5V 4.5 ~ 5.3V 5.75 ~ 6.75V 9.4 ~ 10.9V 13.8 ~ 16.2V
2.88 ~ 3.38V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
UL60950-1, TUV EN60950-1 , CCC GB4943 approved
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3,GB9254 class B,GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85, 10 ~ 95% RH
±0.03%/ (0 ~ 50)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
206.5K hrs min. MIL-HDBK-217F (25)
215*115*30mm (L*W*H)
0.9Kg; 15pcs/14.5Kg/0.78CUFT









EMC IMMUNITY
EMC EMISSION
RSP-320 series
320W Single Output with PFC Function
2.7A/115VAC 1.5 A/230VAC 4A/115VAC 2A/230VAC
AC CURRENT (Typ.)
File Name:RSP-320-SPEC 2015-01-22






 


SPECIFICATION
RSP-320-24RSP-320-15 RSP-320-27 RSP-320-36 RSP-320-48RSP-320-13.5
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.) Note.2
OUTPUT VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
SAFETY &
EMC
(Note 5)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
PROTECTION
24V15V 27V 36V 48V13.5V
13.4A21.4A 11.9A 8.9A 6.7A23.8A
0 ~ 13.4A0 ~ 21.4A 0 ~ 11.9A 0 ~ 8.9A 0 ~ 6.7A0 ~ 23.8A
321.6W321W 321.3W 320.4W 321.6W321.3W
150mVp-p150mVp-p 200mVp-p 220mVp-p 240mVp-p150mVp-p
12 ~ 15V 20 ~ 26.4V13.5 ~ 18V 26 ~ 31.5V 32.4 ~ 39.6V 41 ~ 56V
±1.0%±1.0% ±1.0% ±1.0% ±1.0%±1.0%
±0.2%±0.3% ±0.2% ±0.2% ±0.2%±0.3%
±0.5%±0.5% ±0.5% ±0.5% ±0.5%±0.5%
1500ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load
8ms at full load 230VAC /115VAC
88 ~ 264VAC 124 ~ 370VDC
47 ~ 63Hz
PF>0.95/230VAC PF>0.98/115VAC at full load
88.5% 89% 89% 89.5% 90%88%
20A/115VAC 40A/230VAC
4A/115VAC 2A/230VAC
<1mA / 240VAC
105 ~ 135% rated output power
18.8 ~ 21.8V 27.6 ~ 32.4V 32.9 ~ 38.3V 41.4 ~ 48.6V 58.4 ~ 68V
15.7 ~ 18.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85, 10 ~ 95% RH
±0.03%/ (0 ~ 50)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
206.5K hrs min. MIL-HDBK-217F (25)
215*115*30mm (L*W*H)
0.9Kg; 15pcs/14.5Kg/0.78CUFT









AC CURRENT (Typ.)
EMC IMMUNITY
EMC EMISSION
RSP-320 series
320W Single Output with PFC Function
File Name:RSP-320-SPEC 2015-01-22
UL60950-1, TUV EN60950-1 , CCC GB4943 approved
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3,GB9254 class B,GB17625.1
USP-225 seri esUSP-225 se ri esSP-320 se ri es
Mechanical Specification
Derating Curve Static Characteristics
File Name:RSP-320-SPEC 2015-01-22
Case No.207A Unit:mm
AMBIENT TEMPERATURE () INPUT VOLTAGE (VAC) 60Hz
9088 95 100 115 135 155 175 195 230 264
LOAD (%)
LOAD (%)
10 20 30 40 50 60 70
20
40
60
80
100
-30 0
320W Single Output with PFC Function
(HORIZONTAL)
Block Diagram PFC fosc : 100KHz
PWM fosc : 100KHz
PWM & PFC CIRCUIT
DETECTION
O.L.P.
EMI
FILTER RECTIFIERS POWER
SWITCHING FILTER
&
RECTIFIERS +V
-V
I/P
FG
CONTROL O.V.P.
O.T.P.
INRUSH
CURRENT
ACTIVE
LIMITING
FANFAN
CONTROL
SPEED
90
100
80
70
60
50
40
Terminal Pin No. Assignment :
Pin No. Pin No.
1 4~6
3
2 7~9
Assignment Assignment
AC/L DC OUTPUT -V
FG
AC/N DC OUTPUT +V
RSP-320 series
36.7
12.5
30
4-M4(Both Sides) L=5mm
32.5 150
32.5 150
215
direction
Air flow
47.45
135
9.5
16
115
50
32.5
+V
ADJ.
LED
1
8
2
3
4
5
6
7
8
9
4-M4 L=4mm
15
6.5 6.5
2
6.912.8
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Mean Well:
RSP-320-7.5 RSP-320-3.3 RSP-320-2.5 RSP-320-12 RSP-320-4 RSP-320-5 RSP-320-15 RSP-320-13.5 RSP-
320-24 RSP-320-48 RSP-320-27 RSP-320-36