Aluminum electrolytic capacitors
Single-ended capacitors
Series/Type: B41827, B43827
Date: December 2010
© EPCOS AG 2010. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
General-purpose grade capacitors
Applications
General-purpose applications
Semi-professional to professional application range
For filtering, coupling and pulse circuits
Features
Miniaturized dimensions
RoHS-compatible
Useful life of 2000 h at 85 °C
Construction
Radial leads
Charge-discharge proof, polar
Aluminum case with insulating sleeve
Minus pole marking on the insulating sleeve
Case with safety vent from diameter 8 mm
Delivery mode
Bulk
Taped, Ammo pack
Cut (see chapter "Single-ended Taping, packing and lead
configurations, Cut leads (Chapter A)")
Kinked (see chapter "Single-ended Taping, packing and
lead configurations, Kinked leads (Chapter A)")
Refer to chapter "Single-ended capacitors Taping, packing
and lead configurations" for further details.
Single-ended capacitors B41827, B43827
Standard series 85 °C
Page 2 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Specifications and characteristics in brief
Series B41827 B43827
Rated voltage VR6.3 ... 100 V DC 160 ... 450 V DC
Surge voltage VSVR250 V DC: 1.15 VR(at room temperature)
VR> 250 V DC: 1.1 VR(at room temperature)
Rated capacitance CR0.47 ... 22000 µF 0.47 ... 330 µF
Capacitance tolerance ±20% M±20% M
Dissipation factor
(max.)
(20 °C, 120 Hz)
For capacitance higher than 1000 µF add 0.02 for every increase of
1000 µF.
VR
(V DC)
6.3 10 16 25 35 50 63 100 160
...
250
350
...
400
450
tan δ0.22 0.20 0.16 0.14 0.12 0.10 0.09 0.08 0.18 0.20 0.23
Leakage current Ileak
(20 °C, after
5 minutes) or 3 µA, whichever is greater
Useful life
85 °C; VR; IAC,R > 2000 h
Requirements C/C ±20% of initial value
tan δ 2 times initial specified value
Ileak initial specified limit
Shelf life After storage for 1000 h at 85 °C, the capacitors shall meet the
requirement of load life test after reforming process. After test: VRto be
applied for 30 minutes, 24 to 48 hours before measurement.
Vibration resistance test To IEC 60068-2-6, test Fc:
Frequency range 10 ... 55 Hz, displacement amplitude 0.75 mm,
acceleration max. 10 g, duration 3 ×2 h.
If can size D <16 mm, capacitor is mounted by the leads
If can size D 16 mm, capacitor rigidly clamped by the aluminum case
IEC climatic category To IEC 60068-1:
VR100 V DC: 40/085/56 (40 °C/+85 °C/56 days damp heat test)
VR> 100 V DC: 25/085/56 (25 °C/+85 °C/56 days damp heat test)
B41827, B43827
Standard series 85 °C
Page 3 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Dimensional drawing
Safety vent for diameter 8 mm.
Case Dimensions
d×l
mm
dmax ×lmax
mm
a
mm
b
mm
5×11 5.5 ×12.5 2.0 ±0.5 0.50 ±0.1
6.3 ×11 6.8 ×12.5 2.5 ±0.5 0.50 ±0.1
8×11.5 8.5 ×13.0 3.5 ±0.5 0.60 ±0.1
10 ×12.5 11.0 ×14.0 5.0 ±0.5 0.60 ±0.1
10 ×16 11.0 ×17.5 5.0 ±0.5 0.60 ±0.1
10 ×20 11.0 ×22.0 5.0 ±0.5 0.60 ±0.1
12.5 ×20 13.5 ×22.0 5.0 ±0.5 0.60 ±0.1
12.5 ×25 13.5 ×27.0 5.0 ±0.5 0.60 ±0.1
16 ×25 17.0 ×27.0 7.5 ±0.5 0.80 ±0.1
16 ×31.5 17.0 ×33.5 7.5 ±0.5 0.80 ±0.1
16 ×35.5 17.0 ×37.5 7.5 ±0.5 0.80 ±0.1
18 ×35.5 19.0 ×37.5 7.5 ±0.5 0.80 ±0.1
18 ×40 19.0 ×42.0 7.5 ±0.5 0.80 ±0.1
B41827, B43827
Standard series 85 °C
Page 4 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Overview of available types B41827
VR(V DC) 6.3 10 16 25
Case dimensions d ×l (mm)
CR(µF)
47 5 ×11
100 5 ×11 5 ×11 6.3 ×11
220 5 ×11 6.3 ×11 6.3 ×11 8 ×11.5
330 6.3 ×11 6.3 ×11 8 ×11.5 10 ×12.5
470 6.3 ×11 8 ×11.5 8 ×11.5 10 ×12.5
1000 10 ×12.5 10 ×12.5 10 ×16 10 ×20
2200 10 ×20 10 ×20 12.5 ×20 12.5 ×25
3300 12.5 ×20 12.5 ×20 12.5 ×25 16 ×25
4700 12.5 ×25 12.5 ×25 16 ×25 16 ×31.5
6800 16 ×25
10000 16 ×25 16 ×35.5 18 ×35.5
15000 16 ×35.5 18 ×35.5
22000 18 ×40
B41827
Standard series 85 °C
Page 5 of 39Please read Cautions and warnings and
Important notes at the end of this document.
VR(V DC) 35 50 63 100
Case dimensions d ×l (mm)
CR(µF)
0.47 5 ×11
1.0 5 ×11
2.2 5 ×11
3.3 5 ×11
4.7 5 ×11
10 5 ×11 5 ×11 6.3 ×11
22 5 ×11 6.3 ×11 8 ×11.5
33 5 ×11 5 ×11 6.3 ×11 10 ×12.5
47 5 ×11 6.3 ×11 6.3 ×11 10 ×12.5
100 6.3 ×11 8 ×11.5 10 ×12.5 10 ×20
220 10 ×12.5 10 ×12.5 10 ×20 12.5 ×25
330 10 ×12.5 10 ×16 12.5 ×20 16 ×25
470 10 ×16 10 ×20 12.5 ×25 16 ×31.5
1000 12.5 ×25 16 ×20 16 ×31.5 18 ×40
2200 16 ×25 16 ×31.5
3300 16 ×31.5
4700 18 ×35.5
B41827
Standard series 85 °C
Page 6 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Overview of available types B43827
VR(V DC) 160 200 250 350 400 450
Case dimensions d ×l (mm)
CR(µF)
0.47 5 ×11 5 ×11 6.3 ×11 8 ×11.5
1.0 5 ×11 5 ×11 6.3 ×11 6.3 ×11 8 ×11.5
2.2 5 ×11 6.3 ×11 8 ×11.5 8 ×11.5 10 ×12.5
3.3 6.3 ×11 6.3 ×11 6.3 ×11 10 ×12.5 10 ×12.5 10 ×16
4.7 6.3 ×11 8 ×11.5 8 ×11.5 10 ×12.5 10 ×16 10 ×20
10 8 ×11.5 10 ×12.5 10 ×12.5 10 ×20 12.5 ×20 12.5 ×20
22 10 ×16 10 ×20 10 ×20 12.5 ×25 16 ×25 16 ×25
33 10 ×20 12.5 ×20 12.5 ×25 16 ×25 16 ×25 16 ×31.5
47 12.5 ×25 12.5 ×20 12.5 ×25 16 ×35.5 16 ×35.5 18 ×40
100 16 ×25 16 ×25 16 ×31.5 18 ×40
220 16 ×35.5 18 ×35.5
330 18 ×35.5
B43827
Standard series 85 °C
Page 7 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B41827
CR
120 Hz, 20 °C
µF
Case dimensions
d×l
mm
IAC,R
120 Hz, 85 °C
mA
Ordering code
(composition see below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk
002 = for cut leads, bulk
016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for 5 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for 5 ... 6.3 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for 5 ... 12.5 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×25 ... 16 ×31.5 mm)
VR= 6.3 V DC
220 5 ×11 200 B41827A2227M***
330 6.3 ×11 270 B41827A2337M***
470 6.3 ×11 321 B41827A2477M***
1000 10 ×12.5 542 B41827A2108M***
2200 10 ×20 1005 B41827A2228M***
3300 12.5 ×20 1195 B41827A2338M***
4700 12.5 ×25 1560 B41827A2478M***
6800 16 ×25 1925 B41827A2688M***
10000 16 ×25 2360 B41827A2109M***
15000 16 ×35.5 2855 B41827A2159M***
22000 18 ×40 3345 B41827A2229M***
VR= 10 V DC
100 5 ×11 130 B41827A3107M***
220 6.3 ×11 280 B41827A3227M***
330 6.3 ×11 290 B41827A3337M***
470 8 ×11.5 385 B41827A3477M***
1000 10 ×12.5 650 B41827A3108M***
2200 10 ×20 1082 B41827A3228M***
3300 12.5 ×20 1436 B41827A3338M***
4700 12.5 ×25 1783 B41827A3478M***
10000 16 ×35.5 2700 B41827A3109M***
15000 18 ×35.5 3100 B41827A3159M***
VR= 16 V DC
100 5 ×11 160 B41827A4107M***
220 6.3 ×11 261 B41827A4227M***
330 8 ×11.5 373 B41827A4337M***
470 8 ×11.5 446 B41827A4477M***
1000 10 ×16 790 B41827A4108M***
B41827
Standard series 85 °C
Page 8 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B41827
CR
120 Hz, 20 °C
µF
Case dimensions
d×l
mm
IAC,R
120 Hz, 85 °C
mA
Ordering code
(composition see below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk
002 = for cut leads, bulk
016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for 5 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for 5 ... 6.3 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for 5 ... 12.5 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×25 ... 16 ×31.5 mm)
VR= 16 V DC
2200 12.5 ×20 1310 B41827A4228M***
3300 12.5 ×25 1695 B41827A4338M***
4700 16 ×25 2100 B41827A4478M***
10000 18 ×35.5 2980 B41827A4109M***
VR= 25 V DC
47 5 ×11 108 B41827A5476M***
100 6.3 ×11 192 B41827A5107M***
220 8 ×11.5 335 B41827A5227M***
330 10 ×12.5 446 B41827A5337M***
470 10 ×12.5 547 B41827A5477M***
1000 10 ×20 962 B41827A5108M***
2200 12.5 ×25 1560 B41827A5228M***
3300 16 ×25 1985 B41827A5338M***
4700 16 ×31.5 2455 B41827A5478M***
VR= 35 V DC
33 5 ×11 102 B41827A7336M***
47 5 ×11 130 B41827A7476M***
100 6.3 ×11 212 B41827A7107M***
220 10 ×12.5 390 B41827A7227M***
330 10 ×12.5 495 B41827A7337M***
470 10 ×16 652 B41827A7477M***
1000 12.5 ×25 1158 B41827A7108M***
2200 16 ×25 1810 B41827A7228M***
3300 16 ×31.5 2293 B41827A7338M***
4700 18 ×35.5 2710 B41827A7478M***
B41827
Standard series 85 °C
Page 9 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B41827
CR
120 Hz, 20 °C
µF
Case dimensions
d×l
mm
IAC,R
120 Hz, 85 °C
mA
Ordering code
(composition see below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk
002 = for cut leads, bulk
016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for 5 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for 5 ... 6.3 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for 5 ... 12.5 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×25 ... 16 ×31.5 mm)
VR= 50 V DC
10 5 ×11 58 B41827A6106M***
22 5 ×11 85 B41827A6226M***
33 5 ×11 117 B41827A6336M***
47 6.3 ×11 155 B41827A6476M***
100 8 ×11.5 260 B41827A6107M***
220 10 ×12.5 430 B41827A6227M***
330 10 ×16 510 B41827A6337M***
470 10 ×20 700 B41827A6477M***
1000 16 ×20 1100 B41827A6108M***
2200 16 ×31.5 1540 B41827A6228M***
VR= 63 V DC
10 5 ×11 60 B41827A8106M***
22 6.3 ×11 100 B41827A8226M***
33 6.3 ×11 140 B41827A8336M***
47 6.3 ×11 170 B41827A8476M***
100 10 ×12.5 300 B41827A8107M***
220 10 ×20 475 B41827A8227M***
330 12.5 ×20 710 B41827A8337M***
470 12.5 ×25 900 B41827A8477M***
1000 16 ×31.5 1300 B41827A8108M***
VR= 100 V DC
0.47 5 ×11 13 B41827A9474M***
1.0 5 ×11 20 B41827A9105M***
2.2 5 ×11 29 B41827A9225M***
3.3 5 ×11 36 B41827A9335M***
4.7 5 ×11 43 B41827A9475M***
10 6.3 ×11 75 B41827A9106M***
22 8 ×11.5 130 B41827A9226M***
B41827
Standard series 85 °C
Page 10 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B41827
CR
120 Hz, 20 °C
µF
Case dimensions
d×l
mm
IAC,R
120 Hz, 85 °C
mA
Ordering code
(composition see below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk
002 = for cut leads, bulk
016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for 5 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for 5 ... 6.3 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for 5 ... 12.5 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×25 ... 16 ×31.5 mm)
VR= 100 V DC
33 10 ×12.5 180 B41827A9336M***
47 10 ×12.5 230 B41827A9476M***
100 10 ×20 370 B41827A9107M***
220 12.5 ×25 620 B41827A9227M***
330 16 ×25 760 B41827A9337M***
470 16 ×31.5 1000 B41827A9477M***
1000 18 ×40 1380 B41827A9108M***
B41827
Standard series 85 °C
Page 11 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B43827
CR
120 Hz, 20 °C
µF
Case dimensions
d×l
mm
IAC,R
120 Hz, 85 °C
mA
Ordering code
(composition see below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk
002 = for cut leads, bulk
016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for 5 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for 5 ... 6.3 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for 5 ... 12.5 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×25 ... 16 ×31.5 mm)
VR= 160 V DC
0.47 5 ×11 15 B43827A1474M***
1.0 5 ×11 22 B43827A1105M***
2.2 5 ×11 33 B43827A1225M***
3.3 6.3 ×11 40 B43827A1335M***
4.7 6.3 ×11 49 B43827A1475M***
10 8 ×11.5 80 B43827A1106M***
22 10 ×16 152 B43827A1226M***
33 10 ×20 203 B43827A1336M***
47 12.5 ×25 268 B43827A1476M***
100 16 ×25 423 B43827A1107M***
220 16 ×35.5 786 B43827A1227M***
330 18 ×35.5 945 B43827A1337M***
VR= 200 V DC
3.3 6.3 ×11 40 B43827A2335M***
4.7 8 ×11.5 56 B43827A2475M***
10 10 ×12.5 95 B43827A2106M***
22 10 ×20 170 B43827A2226M***
33 12.5 ×20 225 B43827A2336M***
47 12.5 ×20 267 B43827A2476M***
100 16 ×25 490 B43827A2107M***
220 18 ×35.5 815 B43827A2227M***
VR= 250 V DC
0.47 5 ×11 15 B43827F2474M***
1.0 5 ×11 22 B43827F2105M***
2.2 6.3 ×11 33 B43827F2225M***
3.3 6.3 ×11 47 B43827F2335M***
4.7 8 ×11.5 56 B43827F2475M***
10 10 ×12.5 103 B43827F2106M***
B43827
Standard series 85 °C
Page 12 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B43827
CR
120 Hz, 20 °C
µF
Case dimensions
d×l
mm
IAC,R
120 Hz, 85 °C
mA
Ordering code
(composition see below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk
002 = for cut leads, bulk
016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for 5 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for 5 ... 6.3 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for 5 ... 12.5 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×25 ... 16 ×31.5 mm)
VR= 250 V DC
22 10 ×20 185 B43827F2226M***
33 12.5 ×25 225 B43827F2336M***
47 12.5 ×25 268 B43827F2476M***
100 16 ×31.5 525 B43827F2107M***
VR= 350 V DC
1.0 6.3 ×11 22 B43827A4105M***
2.2 8 ×11.5 38 B43827A4225M***
3.3 10 ×12.5 54 B43827A4335M***
4.7 10 ×12.5 65 B43827A4475M***
10 10 ×20 115 B43827A4106M***
22 12.5 ×25 185 B43827A4226M***
33 16 ×25 276 B43827A4336M***
47 16 ×35.5 334 B43827A4476M***
100 18 ×40 510 B43827A4107M***
VR= 400 V DC
0.47 6.3 ×11 15 B43827A9474M***
1.0 6.3 ×11 23 B43827A9105M***
2.2 8 ×11.5 40 B43827A9225M***
3.3 10 ×12.5 55 B43827A9335M***
4.7 10 ×16 67 B43827A9475M***
10 12.5 ×20 118 B43827A9106M***
22 16 ×25 200 B43827A9226M***
33 16 ×25 280 B43827A9336M***
47 16 ×35.5 362 B43827A9476M***
B43827
Standard series 85 °C
Page 13 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and ordering codes B43827
CR
120 Hz, 20 °C
µF
Case dimensions
d×l
mm
IAC,R
120 Hz, 85 °C
mA
Ordering code
(composition see below)
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk
002 = for cut leads, bulk
016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for 5 mm)
007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for 5 ... 6.3 mm)
006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for 8 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for 5 ... 12.5 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d ×l=16×25 ... 16 ×31.5 mm)
VR= 450 V DC
0.47 8 ×11.5 18 B43827A5474M***
1.0 8 ×11.5 24 B43827A5105M***
2.2 10 ×12.5 36 B43827A5225M***
3.3 10 ×16 44 B43827A5335M***
4.7 10 ×20 56 B43827A5475M***
10 12.5 ×20 95 B43827A5106M***
22 16 ×25 170 B43827A5226M***
33 16 ×31.5 235 B43827A5336M***
47 18 ×40 302 B43827A5476M***
B43827
Standard series 85 °C
Page 14 of 39Please read Cautions and warnings and
Important notes at the end of this document.
1) Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life
graphs.
Useful life
depending on ambient temperature TAunder ripple current operating conditions1)
B41827
Useful life
depending on ambient temperature TAunder ripple current operating conditions1)
B43827
B41827, B43827
Standard series 85 °C
Page 15 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Frequency factor of permissible ripple current IAC versus frequency f
B41827, B43827
Standard series 85 °C
Page 16 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Taping, packing and lead configurations
Taping
Single-ended capacitors are available taped in Ammo pack from diameter 4 to 18 mm as follows:
Lead spacing F = 2.0 mm (d=4 5 mm)
Lead spacing F = 2.5 mm (d=4 6.3 mm)
Lead spacing F = 3.5 mm (d = 8 mm)
Lead spacing F = 5.0 mm (d=4 12.5 mm)
Lead spacing F = 7.5 mm (d = 16 ... 18 mm).
Lead spacing 2.0 mm (d = 4 ... 5 mm)
Last 3 digits of ordering code: 016
Dimensions in mm
d F H W W0W1W2P P0P1I1th D0
4 ... 5 2.0 18.5 18.0 7.0 9.0 3.0 12.7 12.7 5.10 1.0 0.7 1 4.0
+0.8
0.2 ±0.75 ±0.5 min. ±0.5 max. ±1.0 ±0.3 ±0.7 max. ±0.2 ±1.0 ±0.2
B41827, B43827
Standard series 85 °C
Page 17 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Lead spacing 2.5 mm (d = 4 ... 6.3 mm)
Last 3 digits of ordering code: 007
Dimensions in mm
d F H W W0W1W2H0P P0P1I1th D0
4 ... 6.3 2.5 18.5 18.0 5.5 9.0 1.5 16.0 12.7 12.7 5.1 1.0 0.7 1.0 4.0
Toler-
rance
+0.8
0.2 ±0.75 ±0.5 min. ±0.5 max. ±0.5 ±1.0 ±0.2 ±0.5 max. ±0.2 max. ±0.2
Lead spacing 3.5 mm (d = 8 mm)
Last 3 digits of ordering code: 006
Dimensions in mm
d F H W W0W1W2P P0P1I1th D0
8 3.5 18.5 18.0 10 9.0 3.0 12.7 12.7 4.6 1.0 0.7 1.0 4.0
Toler-
ance
+0.8
0.2 ±1.0 ±0.5 min. ±0.5 max. ±1.0 ±0.3 ±0.6 max. ±0.2 max. ±0.2
Leads can also run straight through the taping area. Taping is available up to dimensions
d×l=8×15 mm.
B41827, B43827
Standard series 85 °C
Page 18 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Lead spacing 5.0 mm (d = 4 ... 8 mm)
Last 3 digits of ordering code: 008
Lead spacing 5.0 mm (d = 10 ... 12.5 mm)
Last 3 digits of ordering code: 008
Dimensions in mm
d F H W W0W1W2H0P P0P1I1th D0
4 ...
6.3 5.0 18.5 18.0 5.5 9.0 1.5 16.0 12.7 12.7 3.85 1.0 0.6 1.0 4.0
820.0 10.0 16.0 12.7 12.7 3.85
10 5.0 19.0 18.0 12.5 9.0 1.5 12.7 12.7 3.85 1.0 0.6 1.0 4.0
12.5 19.0 12.5 15.0 15.0 5.0
Toler-
ance
+0.8
0.2 ±0.75 ±0.5 min. ±0.5 max. ±0.5 ±1.0 ±0.2 ±0.5 max. +0.3
0.2 max. ±0.2
Taping is available up to dimensions d ×l=10×31.5 mm and 12.5 ×25 mm.
Taping is not available for d ×l=8×20 mm.
B41827, B43827
Standard series 85 °C
Page 19 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Lead spacing 7.5 mm (d = 16 ...18 mm)
Last 3 digits of ordering code: 009
Dimensions in mm
d F H W W0W1W2P P0P1I1tPh D0
16 7.5 18.5 18.0 12.5 9.0 1.5 30.0 15.0 3.75 1.0 0.7 0 0 4.0
18
Toler-
ance ±0.8 0.5
+0.75 ±0.5 min. ±0.5 max. ±1.0 ±0.2 ±0.5 max. ±0.2 ±1.0 ±1.0 ±0.2
Taping is available up to dimensions d ×l=16×31.5 mm and 18 ×31.5 mm.
B41827, B43827
Standard series 85 °C
Page 20 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Cut or kinked leads
Single-ended capacitors are available with cut or kinked leads. Other lead configurations also
available upon request.
Cut leads (Chapter A)
Available for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086,
B43088, B43827, B43828.
Last 3 digits of ordering code: 002
Case size d x l (mm) Dimensions
(mm)
a±0.5
4 x 7 1.5
5 x 7 2.0
5 x 11 2.0
6.3 x 7 2.5
6.3 x 11 2.5
8 x 7 3.5
8 x 11.5 3.5
8 x 15 3.5
8 x 20 3.5
10 x 12.5 5.0
10 x 16 5.0
10 x 20 5.0
10 x 25 5.0
10 x 31.5 5.0
Case size d x l (mm) Dimensions
(mm)
a±0.5
12.5 x 16 5.0
12.5 x 20 5.0
12.5 x 25 5.0
12.5 x 31.5 5.0
12.5 x 35.5 5.0
12.5 x 40 5.0
16 x 20 7.5
16 x 25 7.5
16 x 31.5 7.5
16 x 35.5 7.5
16 x 40 7.5
18 x 20 7.5
18 x 25 7.5
18 x 31.5 7.5
18 x 35.5 7.5
18 x 40 7.5
B41827, B43827
Standard series 85 °C
Page 21 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Cut leads (Chapter B)
Available for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896,
B42824, B42851, B43866, B43867, B43890, B43896.
Last 3 digits of ordering code: 002
With stand-off rubber seal Case size Dimensions (mm)
d×l (mm) a ±0.5
10 ×12.5 5.0
10 ×16 5.0
10 ×20 5.0
12.5 ×20 5.0
12.5 ×25 5.0
16 ×20 7.5
16 ×25 7.5
16 ×31.5 7.5
16 ×35.5 7.5
18 ×20 7.5
18 ×25 7.5
18 ×31.5 7.5
18 ×35 7.5
18 ×40 7.5
With flat rubber seal
B41827, B43827
Standard series 85 °C
Page 22 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Kinked leads (Chapter A)
Available for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086,
B43088, B43827, B43828.
Last 3 digits of ordering code: 001
Case size d x l (mm) Dimensions
(mm)
a±0.5
4 x 7 1.5
5 x 7 2.0
5 x 11 2.0
6.3 x 7 2.5
6.3 x 11 2.5
8 x 7 3.5
8 x 11.5 3.5
8 x 15 3.5
8 x 20 3.5
10 x 12.5 5.0
10 x 16 5.0
10 x 20 5.0
10 x 25 5.0
10 x 31.5 5.0
Case size d x l (mm) Dimensions
(mm)
a±0.5
12.5 x 16 5.0
12.5 x 20 5.0
12.5 x 25 5.0
12.5 x 31.5 5.0
12.5 x 35.5 5.0
12.5 x 40 5.0
16 x 20 7.5
16 x 25 7.5
16 x 31.5 7.5
16 x 35.5 7.5
16 x 40 7.5
18 x 20 7.5
18 x 25 7.5
18 x 31.5 7.5
18 x 35.5 7.5
18 x 40 7.5
B41827, B43827
Standard series 85 °C
Page 23 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Kinked leads (Chapter B)
Available for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896,
B42824, B42851, B43866, B43867, B43890, B43896.
Last 3 digits of ordering code: 001
With stand-off rubber seal Case size Dimensions (mm)
d×l (mm) a ±0.5
10 ×20 5.0
12.5 ×20 5.0
12.5 ×25 5.0
16 ×20 7.5
16 ×25 7.5
16 ×31.5 7.5
16 ×35.5 7.5
18 ×20 7.5
18 ×25 7.5
18 ×31.5 7.5
18 ×35 7.5
18 ×40 7.5
With flat rubber seal
B41827, B43827
Standard series 85 °C
Page 24 of 39Please read Cautions and warnings and
Important notes at the end of this document.
PAPR leads (Protection Against Polarity Reversal)
These lead configurations ensure correct placement of the capacitor on the PCB with regard to
polarity. PAPR leads are available for diameters from 10 mm up to 18 mm.
There are three configurations available: Crimped leads, J leads, bent 90°leads
Available for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896,
B42824, B42851, B43866, B43867, B43890, B43896.
Crimped leads
Last 3 digits of ordering code: 003
With stand-off rubber seal With flat rubber seal
Suggestion for PCB hole diameter
Case size Dimensions (mm)
d×l (mm) B ±0.2 C ±0.5 D ±0.1 E ±0.1 a ±0.5 b
16 ×20 1.5 3.0 1.3 0.3 7.5 0.8 ±0.05
16 ×25 1.5 3.0 1.3 0.3 7.5 0.8 ±0.05
16 ×31.5 1.5 3.0 1.3 0.3 7.5 0.8 ±0.05
16 ×35.5 1.5 3.0 1.3 0.3 7.5 0.8 ±0.05
18 ×20 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1
18 ×25 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1
18 ×31.5 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1
18 ×35 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1
18 ×40 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1
B41827, B43827
Standard series 85 °C
Page 25 of 39Please read Cautions and warnings and
Important notes at the end of this document.
J leads
Last 3 digits of ordering code: 004
Suggestion for PCB hole diameter
Case size Dimensions (mm)
d×l (mm) C ±0.5 E ±0.5 J ±0.2 a ±0.5 b
10 ×12.5 3.2 0.7 1.2 5.0 0.6 ±0.05
10 ×16 3.2 0.7 1.2 5.0 0.6 ±0.05
10 ×20 3.2 0.7 1.2 5.0 0.6 ±0.05
12.5 ×20 3.2 0.7 1.2 5.0 0.6 ±0.05
12.5 ×25 3.2 0.7 1.2 5.0 0.6 ±0.05
16 ×20 3.5 0.7 1.6 7.5 0.8 ±0.05
16 ×25 3.5 0.7 1.6 7.5 0.8 ±0.05
16 ×31.5 3.5 0.7 1.6 7.5 0.8 ±0.05
16 ×35.5 3.5 0.7 1.6 7.5 0.8 ±0.05
18 ×20 3.5 0.7 1.6 7.5 0.8 ±0.1
18 ×25 3.5 0.7 1.6 7.5 0.8 ±0.1
18 ×31.5 3.5 0.7 1.6 7.5 0.8 ±0.1
18 ×35 3.5 0.7 1.6 7.5 0.8 ±0.1
B41827, B43827
Standard series 85 °C
Page 26 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Bent 90°leads for horizontal mounting pinning
Last 3 digits of ordering code: 012
Case size Dimensions (mm)
d×l (mm) C ±0.5 E ±0.5 F ±0.5 a ±0.5 b
16 ×20 4.0 4.0 12.0 7.5 0.8 ±0.05
16 ×25 4.0 4.0 12.0 7.5 0.8 ±0.05
16 ×31.5 4.0 4.0 12.0 7.5 0.8 ±0.05
16 ×35.5 4.0 4.0 12.0 7.5 0.8 ±0.05
18 ×20 4.0 4.0 13.0 7.5 0.8 ±0.1
18 ×25 4.0 4.0 13.0 7.5 0.8 ±0.1
18 ×31.5 4.0 4.0 13.0 7.5 0.8 ±0.1
18 ×35 4.0 4.0 13.0 7.5 0.8 ±0.1
18 ×40 4.0 4.0 13.0 7.5 0.8 ±0.1
Bent leads for diameter 12.5 mm available upon request.
B41827, B43827
Standard series 85 °C
Page 27 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Packing units and box dimensions
Ammo pack
Valid for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088,
B43827, B43828.
Case size
d×l
Dimensions (mm) Packing
units
mm Amax Bmax Cmax pcs.
4×7 330 50 196 2000
5×7 330 50 226 2000
5×11 330 50 226 2000
6.3 ×7 330 50 286 2000
6.3 ×11 330 50 286 2000
8×7 330 50 246 1000
8×11.5 330 50 246 1000
8×15 330 50 246 500
10 ×12.5 330 50 196 500
10 ×16 330 54 196 500
10 ×20 330 58 196 500
12.5 ×20 341 60 272 500
12.5 ×25 341 65 272 500
16 ×25 320 65 270 300
16 ×31.5 315 65 275 300
18 ×20 315 65 275 250
18 ×25 315 65 275 250
18 ×31.5 315 65 275 250
B41827, B43827
Standard series 85 °C
Page 28 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Ammo pack
Valid for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824,
B42851, B43866, B43867, B43890, B43896.
Case size
d×l
Dimensions (mm) Packing
units
mm Amax Bmax Cmax pcs.
8×11.5 345 55 240 1000
10 ×12.5 345 55 280 750
10 ×16 345 60 200 500
10 ×20 345 60 200 500
12.5 ×20 345 65 280 500
12.5 ×25 345 65 280 500
16 ×20 315 65 275 300
16 ×25 315 65 275 300
16 ×31.5 315 65 275 300
18 ×20 315 65 275 250
18 ×25 315 65 275 250
18 ×31.5 315 65 275 250
B41827, B43827
Standard series 85 °C
Page 29 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Overview of packing units and code numbers for case sizes 4 x 7 ... 16 x 40
Valid for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088,
B43827, B43828.
Case size
dxl
mm
Standard,
bulk
pcs.
Taped,
Ammo pack
pcs.
Kinked leads,
bulk
pcs.
Cut leads,
bulk
pcs.
4 x 7 10000 2000 15000 15000
5 x 7 7500 2000 10000 10000
5 x 11 5000 2000 10000 10000
6.3 x 7 5000 2000 10000 10000
6.3 x 11 5000 2000 5000 5000
8 x 7 5000 1000 5000 5000
8 x 11.5 2500 1000 4000 4000
8 x 15 2000 1000 2500 2500
8 x 20 1500 2000 2000
10 x 12.5 2000 500 2500 2500
10 x 16 1500 500 2000 2000
10 x 20 1000 500 1500 1500
10 x 25 1000 500 1250 1250
12.5 x 16 750 500 1000 1000
12.5 x 20 750 500 500 500
12.5 x 25 750 500 500 500
12.5 x 31.5 500 750 750
12.5 x 35.5 500 750 750
12.5 x 40 500 750 750
16 x 20 375 300 500 500
16 x 25 375 300 500 500
16 x 31.5 250 300 375 375
16 x 35.5 250 375 375
16 x 40 250 375 375
The last three
digits of the
complete
ordering code
state the lead
configuration
000 Code F (mm) d (mm) 001 002
006
007
008
009
016
3.5
2.5
5.0
7.5
2.0
8
4 ... 6.3
4 ... 12.5
16 ... 18
4 ... 5
B41827, B43827
Standard series 85 °C
Page 30 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Overview of packing units and code numbers for case sizes 18 x 20 ... 18 x 40
Valid for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088,
B43827, B43828.
Case size
dxl
mm
Standard,
bulk
pcs.
Taped,
Ammo pack
pcs.
Kinked leads,
bulk
pcs.
Cut leads,
bulk
pcs.
18 x 20 250 250 100 100
18 x 25 250 250 100 100
18 x 31.5 250 250 100 100
18 x 35.5 250 100 100
18 x 40 250 100 100
The last three
digits of the
complete
ordering code
state the lead
configuration
000 Code F (mm) d (mm) 001 002
009 7.5 16 ... 18
B41827, B43827
Standard series 85 °C
Page 31 of 39Please read Cautions and warnings and
Important notes at the end of this document.
1) Available upon request
Overview of packing units and code numbers for case sizes 8 ×11.5 ... 16 ×35.5
Valid for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824,
B42851, B43866, B43867, B43890, B43896.
PAPR
Case size
d×l
Stan-
dard,
bulk
Taped,
Ammo pack
Kinked
leads,
bulk
Cut
leads,
bulk
Crimped
leads,
blister
J leads,
blister
Bent 90°
leads,
blister
mm pcs. pcs. pcs. pcs. pcs. pcs. pcs.
8×11.5 1000 1000
10 ×12.5 1000 750 1000 675
10 ×16 1000 500 1000 675
10 ×20 500 500 500 500 500
12.5 ×20 350 500 350 350 300 1)
12.5 ×25 250 500 500 500 225 1)
12.5 ×30 200
12.5 ×35 175
12.5 ×40 175
16 ×20 250 300 200 200 200 200 120
16 ×25 250 300 200 200 200 200 120
16 ×31.5 200 300 250 250 344 344 120
16 ×35.5 100 100 100 150 150 150
The last three
digits of the
complete
ordering code
state the lead
configuration
000 Code F (mm) d (mm) 001 002 003 004 012
006
008
009
3.5
5
7.5
8
5...12.5
16...18
B41827, B43827
Standard series 85 °C
Page 32 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Overview of packing units and code numbers for case sizes 18 ×20 ... 18 ×40
Valid for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824,
B42851, B43866, B43867, B43890, B43896.
PAPR
Case size
d×l
Stan-
dard,
bulk
Taped,
Ammo pack
Kinked
leads,
bulk
Cut
leads,
bulk
Crimped
leads,
blister
J leads,
blister
Bent 90°
leads,
blister
mm pcs. pcs. pcs. pcs. pcs. pcs. pcs.
18 ×20 175 250 175 175 200 200 120
18 ×25 150 250 150 150 200 200 120
18 ×31.5 100 250 100 100 150 150 120
18 ×35 100 100 100 150 150 150
18 ×40 125 100 100 120 72
The last three
digits of the
complete
ordering code
state the lead
configuration
000 Code F (mm) d (mm) 001 002 003 004 012
009 7.5 16...18
B41827, B43827
Standard series 85 °C
Page 33 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have not only been optimized with a view to the intended
application, but also with regard to health and environmental compatibility. They do not contain
any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They
contain flame-retarding substances which will quickly extinguish any flame that may have been
ignited.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no safe substitute materials are
currently known. However, the amount of dangerous materials used in our products has been
limited to an absolute minimum. Nevertheless, the following rules should be observed when
handling aluminum electrolytic capacitors:
Any escaping electrolyte should not come into contact with eyes or skin.
If electrolyte does come into contact with the skin, wash the affected parts immediately with
running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If
symptoms persist, seek medical treatment.
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be
well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.
B41827, B43827
Standard series 85 °C
Page 34 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Product safety
The table below summarizes the safety instructions that must be observed without fail. A detailed
description can be found in the relevant sections of chapter "General technical information".
Topic Safety information Reference
chapter "General
technical information"
Polarity Make sure that polar capacitors are connected
with the right polarity.
1
"Basic construction of
aluminum electrolytic
capacitors"
Reverse voltage Voltages polarity classes should be prevented by
connecting a diode.
3.1.6
"Reverse voltage"
Upper category
temperature
Do not exceed the upper category temperature. 7.2
"Maximum permissible
operating temperature"
Maintenance Make periodic inspections of the capacitors.
Before the inspection, make sure that the power
supply is turned off and carefully discharge the
electricity of the capacitors.
Do not apply any mechanical stress to the
capacitor terminals.
10
"Maintenance"
Mounting
position of screw-
terminal capacitors
Do not mount the capacitor with the terminals
(safety vent) upside down.
11.1.
"Mounting positions of
capacitors with screw
terminals"
Mounting of
single-ended
capacitors
The internal structure of single-ended capacitors
might be damaged if excessive force is applied to
the lead wires.
Avoid any compressive, tensile or flexural stress.
Do not move the capacitor after soldering to PC
board.
Do not pick up the PC board by the soldered
capacitor.
Do not insert the capacitor on the PC board with a
hole space different to the lead space specified.
11.4
"Mounting
considerations for
single-ended capacitors"
Robustness of
terminals
The following maximum tightening torques must
not be exceeded when connecting screw
terminals:
M5: 2 Nm
M6: 2.5 Nm
11.3
"Mounting torques"
Soldering Do not exceed the specified time or temperature
limits during soldering.
11.5
"Soldering"
B41827, B43827
Standard series 85 °C
Page 35 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Topic Safety information Reference
chapter "General
technical information"
Soldering,
cleaning agents
Do not allow halogenated hydrocarbons to come
into contact with aluminum electrolytic capacitors.
11.6
"Cleaning agents"
Passive
flammability
Avoid external energy, such as fire or electricity. 8.1
"Passive flammability"
Active
flammability
Avoid overload of the capacitors. 8.2
"Active flammability"
Reference
chapter "Capacitors with
screw terminals"
Breakdown strength
of insulating
sleeves
Do not damage the insulating sleeve, especially
when ring clips are used for mounting.
"Screw terminals
accessories"
B41827, B43827
Standard series 85 °C
Page 36 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Symbols and terms
Symbol English German
C Capacitance Kapazität
CRRated capacitance Nennkapazität
CSSeries capacitance Serienkapazität
CS,T Series capacitance at temperature T Serienkapazität bei Temperatur T
CfCapacitance at frequency f Kapazität bei Frequenz f
d Case diameter, nominal dimension Gehäusedurchmesser, Nennmaß
dmax Maximum case diameter Maximaler Gehäusedurchmesser
ESL Self-inductance Eigeninduktivität
ESR Equivalent series resistance Ersatzserienwiderstand
ESRfEquivalent series resistance at
frequency f
Ersatzserienwiderstand bei Frequenz f
ESRTEquivalent series resistance at
temperature T
Ersatzserienwiderstand bei Temperatur T
f Frequency Frequenz
I Current Strom
IAC Alternating current (ripple current) Wechselstrom
IAC,rms Root-mean-square value of alternating
current
Wechselstrom, Effektivwert
IAC,f Ripple current at frequency f Wechselstrom bei Frequenz f
IAC,max Maximum permissible ripple current Maximal zulässiger Wechselstrom
IAC,R Rated ripple current Nennwechselstrom
IAC,R (B) Rated ripple current for base cooling Nennwechselstromstrom für Bodenkühlung
Ileak Leakage current Reststrom
Ileak,op Operating leakage current Betriebsreststrom
l Case length, nominal dimension Gehäuselänge, Nennmaß
lmax Maximum case length (without
terminals and mounting stud)
Maximale Gehäuselänge (ohne Anschlüsse
und Gewindebolzen)
R Resistance Widerstand
Rins Insulation resistance Isolationswiderstand
Rsymm Balancing resistance Symmetrierwiderstand
T Temperature Temperatur
T Temperature difference Temperaturdifferenz
TAAmbient temperature Umgebungstemperatur
TCCase temperature Gehäusetemperatur
TBCapacitor base temperature Temperatur des Becherbodens
t Time Zeit
t Period Zeitraum
tbService life (operating hours) Brauchbarkeitsdauer (Betriebszeit)
B41827, B43827
Standard series 85 °C
Page 37 of 39Please read Cautions and warnings and
Important notes at the end of this document.
Symbol English German
V Voltage Spannung
VFForming voltage Formierspannung
Vop Operating voltage Betriebsspannung
VRRated voltage, DC voltage Nennspannung, Gleichspannung
VSSurge voltage Spitzenspannung
XCCapacitive reactance Kapazitiver Blindwiderstand
XLInductive reactance Induktiver Blindwiderstand
Z Impedance Scheinwiderstand
ZTImpedance at temperature T Scheinwiderstand bei Temperatur T
tan δDissipation factor Verlustfaktor
λFailure rate Ausfallrate
ε0Absolute permittivity Elektrische Feldkonstante
εrRelative permittivity Dielektrizitätszahl
ωAngular velocity; 2 πf Kreisfrequenz; 2 πf
Note
All dimensions are given in mm.
B41827, B43827
Standard series 85 °C
Page 38 of 39Please read Cautions and warnings and
Important notes at the end of this document.
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical re-
quirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incum-
bent on the customer to check and decide whether an EPCOS product with the properties de-
scribed in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Ma-
terial Data Sheets on the Internet (www.epcos.com/material). Should you have any more de-
tailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the fore-
going for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current ver-
sion of the "General Terms of Delivery for Products and Services in the Electrical In-
dustry" published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap,
DigiSiMic, DSSP, FormFit, MiniBlue, MiniCell, MKK, MKD, MLSC, MotorCap, PCC,
PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap,
SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trade-
marks registered or pending in Europe and in other countries. Further information will be
found on the Internet at www.epcos.com/trademarks.
Important notes
Page 39 of 39