SPECIFICATION
MODEL RQ-65B RQ-65C RQ-65D
DCVOLTAGE
RATEDCURRENT
OUTPUT VOLTAGE ADJ.RANGE
SETUP,RISE,HOLDTIME
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
ACCURRENT
INPUT
INRUSHCURRENT(max.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
5V 12V -5V 5V 15V -5V 12V-15V 24V5V -12V-12V
6A 2A 0.5A 5A 2A 0.5A 1.5A0.5A 1A4A 0.5A0.5A
0.5~8A 0.2~3A 0~1A 0.5~8A 0.2~3A 0~1A 0.2~3A0~1A
0.1~1.5A
0.5~8A 0~1A0~1A
62.5W 65W 68W
80mVp-p
120mVp-p
80mVp-p
80mVp-p
120mVp-p
80mVp-p
120mVp-p
80mVp-p
180mVp-p
80mVp-p 80mVp-p80mVp-p
CH1:4.75~5.5V CH1:4.75~5.5V CH1:4.75~5.5V
2.0% 5.0% 2.0% +8,-4% 5.0% 8.0%5.0% 2.0% 5.0%5.0%
0.5%
0.5%
1.5%
6.0%
0.5% 0.5%
0.5%
1.5% 0.5% 1.5%
6.0%
0.5% 2.0%0.5%
0.5%
0.5%0.5%
3.0% 1.0% 3.0% 1.0% 3.0%1.0% 4.0% 1.0%1.0%
500ms,20ms,50ms/230VAC1200ms,30ms,10ms/115VACatfullload
88~264VAC125~373VDC(300VACpeak5sec.Nodamage)
47~63Hz
76% 78%76%
CH1:5.75~6.75V
2A/115VAC1.2A/230VAC
COLDSTART 40A/230VAC
<2mA /240VAC
110~150% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
UL60950-1, TUVEN60950-1 Approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
-20~+70 (Refertooutputloadderatingcurve)
20~90%RH non-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50 )on+5Voutput
10~500Hz,5G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
245.5Khrsmin.MIL-HDBK-217F(25 )
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
FileName:RQ-65-SPEC2004-03-12
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
129*98*38mm(L*W*H)
0.44Kg;30pcs/13.2Kg/0.72CUFT
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN61000-6-2(EN50082-2)heavyindustrylevel,criteria A
65WQuadOutputSwitchingPowerSupply
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
High realibility
Features :
RQ-65 seri es
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
CURRENTRANGE Note.6
RATEDPOWER Note.6
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
LINEREGULATION Note.4
LOADREGULATION Note.5
ENVIRONMENT
PROTECTION
EMICONDUCTION&RADIATION
SAFETY &
EMC
(Note7)
MechanicalSpecification
DeratingCurve
CaseNo.903Unit:mm
AMBIENTTEMPERATURE( )
LOAD(%)
-20
-20
0
0
10 20 30 40 50 60
20
40
60
80
100
TerminalPin.No Assignment
PinNo. PinNo. PinNo.
1 4
3
2 8
7
6
5
Assignment Assignment Assignment
DCOUTPUT +V2
DCOUTPUT V3
DCOUTPUT -V4
DCOUTPUT +V1
DCOUTPUT COM
FG
AC/N
AC/L
4.5 73.5
9
3 .5
3
8
3 33 3 1
122.5
129
9
8
9
2
-M 3
78 5 .5
1 8
3 -M 3
1 8 .5
9 .5
120
6.5
77
32
3 .5
3 .5
3 .5
FileName:RQ-65-SPEC2004-03-12
OutputDeratingVSInputVoltage
INPUTVOLTAGE(VAC)60Hz
88 10095 120115 160140 200180 240220 264
LOAD(%)
Ta=25
90
100
80
70
60
50
40
70
8
7
6
5
4
3
2
1
78.25
(VERTICAL)
65WQuadOutputSwitchingPowerSupply RQ-65 se ri es