General Description:
20 AWG stranded (19x32) high-conductivity tinned copper conductors, polyethylene insulation, rayon
braid, tinned copper braid shield (85% coverage), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material Dia. (mm)
420 19x32 High Conductivity TC - Tinned Copper 0.9398
Total Number of Conductors: 4
Insulation
Insulation Material:
Insulation Material Wall Thickness (mm) Dia. (mm)
PE - Polyethylene 0.4064 1.7526
Outer Shield
Outer Shield Material:
Type Outer Shield Material Coverage (%)
Braid TC - Tinned Copper 85
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.8128
Overall Cable
Overall Cabling Color Code Chart:
Number Color
1Clear
2Black
3Red
4Green
Overall Cabling Separator Material: Rayon Braid
Overall Nominal Diameter: 6.401 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -20°C To +60°C
UL Temperature Rating: 60°C (UL AWM Style 2094)
Bulk Cable Weight: 68.457 Kg/Km
Max. Recommended Pulling Tension: 444.820 N
Min. Bend Radius/Minor Axis: 63.500 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
AWM Specification: UL Style 2094 (300 V 60°C)
EU Directive 2011/65/EU (ROHS II): Yes
Page 1 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8404 Multi-Conductor - Four-Conductor Star Quad, Low-Impedance Cable
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: VW-1
Plenum/Non-Plenum
Plenum (Y/N): No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
45
Nom. Inductance:
Inductance (µH/m)
0.6562
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
75.463
Nom. Cap. Between Cond. in a Quad Config.:
Capacitance (pF/m)
160.769
Nominal Velocity of Propagation:
VP (%)
66
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
33.4662
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
10.5976
Max. Operating Voltage - UL:
Voltage
300 V RMS (UL AWM Style 2094)
Max. Recommended Current:
Current
3.1 Amps per conductor @ 25°C
Other Electrical Characteristic 1: 2/c 17 AWG equivalent DCR when connected to a 3-pin XLR.
Notes (Overall)
Notes: Quad connection scheme: The two blue wires (or wires directly opposite one another) are connected together to form one
conductor, and similarly the two white wires (or remaining wires) are connected together to form the second conductor.
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
Page 2 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8404 Multi-Conductor - Four-Conductor Star Quad, Low-Impedance Cable
8404 060U1000 305 MT 21.773 KG CHROME 4 #20 PE SHLD PVC
8404 060100 30 MT 2.449 KG CHROME 4 #20 PE SHLD PVC
8404 0601000 305 MT 22.226 KG CHROME C 4 #20 PE SHLD PVC
8404 060500 152 MT 11.340 KG CHROME C 4 #20 PE SHLD PVC
Notes:
C = CRATE REEL PUT-UP.
Revision Number: 1 Revision Date: 05-14-2007
© 2013 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8404 Multi-Conductor - Four-Conductor Star Quad, Low-Impedance Cable