Qualifi cation Tes t
Report 501-528-2
28Dec04 Rev A
EC 0990-1699-04
NETCONNECT* SL Series Category 5e Jacks
©2004 Tyco Electronics Corpo ration
Harrisburg, PA
All Internatio nal Rights Reserved
* Trademark
| Indicates change 1 of 3
LOC B
1. INTRODUCTION
1.1. Purpose
Testing w as performed on NETCONNECT* SL Series Category 5e Jacks to determine thei r
confor mance to the requirements of Product Specification 108- 1990-2 Revi sion A.
1.2. Scope
This report covers the transmission perfor mance of the NETCONNECT SL Series Cat egory 5e Jacks.
Testing w as performed at Intertek T esting Ser vices Inc., 3933 US Route 11, Cortland, New York 13045
between 14Feb02 and 12Mar02. The test file number for this testing is 3019525- 001. This
documentation is on file at and available f rom the Engineering Assurance Product Test Laborat ory
under f il e number CTL 4691-001.|
1.3. Conclusion
The NETCONNECT SL Series Category 5e Jacks listed in paragraph 1.5., conformed to the
tr ansmission per formance requi rements of Product Speci fication 108-1990- 2 Revision A.
1.4. Product Descript ion
NETCONNECT Category 5e shielded and unshielded SL 110 jacks are desi gned for i nstallation into
various outlet plates, surface mount boxes, panels, and other similar type fittings. Jacks incorporate IDC
ter minals f or termi nating both shiel ded or unshielded tw isted pair communications cable and wil l
accommodate 22 - 24 AWG solid and 24 AWG stranded conductors. T he maximum conductor
i nsulation diameter is 1.27 mm [.050 in].
1.5. Test Specimens
Test specimens wer e representative of normal producti on lots. Specimens identified with the following
part numbers were used for test:
Test Group Quantity Part Number Description
1 30 1375191 NETCONNECT SL Seri es Category 5e Jacks
Fi gure 1
1.6. Environmental Conditions
Unl ess otherwise stated, the following environmental conditions pr evailed during testing:
!
Temperature: 15 to 35
/
C
!
Relative Humidity: 25 to 75%