PART NO. 37-6607B
Replaces 37-6607A
0834
TransGlobal®
TG Series
International Transformer
Printed Circuit Mount
ELECTROCUTION HAZARD
Disconnect electric power to system at
main fuse or circuit breaker box before
servicing. Failure to do so could result
in death or serious injury.
FIRE HAZARD
Do not exceed transformer ratings.
Higher voltage may damage control
and could cause personal injury or
property damage.
SPECIFICATIONS:
WARNING
!
INPUT:
OUTPUT:
INSULATION RATING:
DIELECTRIC STRENGTH:
AGENCY APPROVALS:
FILE NOs.:
115/230 VAC, 50/60 Hz
See Table
Class B (130˚ C)
4,000 VRMS
UL recognized component for use in
the US and Canada
TUV certified to EN61558
Designed to requirements of EN60950
UL File # E173993
TUV Report # DI 401341
STANCOR Secondary RMS Rating
PART Series Parallel Agency
NUMBER VA Volts Amps Volts Amps
TG2H-10 2.5 10.0 C.T. @ 0.25 5.0 @ 0.50
TG05-10 5 10.0 C.T. @ 0.50 5.0 @ 1.00
TG10-10 10 10.0 C.T. @ 1.00 5.0 @ 2.00
TG20-10 20 10.0 C.T. @ 2.00 5.0 @ 4.00
TG30-10 30 10.0 C.T. @ 3.00 5.0 @ 6.00
TG56-10 56 10.0 C.T. @ 5.60 5.0 @ 11.20
TG2H-12 2.5 12.6 C.T. @ 0.20 6.3 @ 0.40
TG05-12 5 12.6 C.T. @ 0.40 6.3 @ 0.80
TG10-12 10 12.6 C.T. @ 0.80 6.3 @ 1.60
TG20-12 20 12.6 C.T. @ 1.60 6.3 @ 3.20
TG30-12 30 12.6 C.T. @ 2.40 6.3 @ 4.80
TG56-12 56 12.6 C.T. @ 4.40 6.3 @ 8.80
TG2H-16 2.5 16.0 C.T. @ 0.15 8.0 @ 0.30
TG05-16 5 16.0 C.T. @ 0.31 8.0 @ 0.62
TG10-16 10 16.0 C.T. @ 0.62 8.0 @ 1.25
TG20-16 20 16.0 C.T. @ 1.25 8.0 @ 2.50
TG30-16 30 16.0 C.T. @ 1.90 8.0 @ 3.80
TG56-16 56 16.0 C.T. @ 3.50 8.0 @ 7.00
TG2H-20 2.5 20.0 C.T. @ 0.12 10.0 @ 0.24
TG05-20 5 20.0 C.T. @ 0.25 10.0 @ 0.50
TG10-20 10 20.0 C.T. @ 0.50 10.0 @ 1.00
TG20-20 20 20.0 C.T. @ 1.00 10.0 @ 2.00
TG30-20 30 20.0 C.T. @ 1.50 10.0 @ 3.00
TG56-20 56 20.0 C.T. @ 2.80 10.0 @ 5.60
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
Certif.
STANCOR Secondary RMS Rating
PART Series Parallel Agency
NUMBER VA Volts Amps Volts Amps
TG2H-24 2.5 24.0 C.T. @ 0.10 12.0 @ 0.20
TG05-24 5 24.0 C.T. @ 0.21 12.0 @ 0.42
TG10-24 10 24.0 C.T. @ 0.42 12.0 @ 0.84
TG20-24 20 24.0 C.T. @ 0.83 12.0 @ 1.66
TG30-24 30 24.0 C.T. @ 1.25 12.0 @ 2.50
TG56-24 56 24.0 C.T.@ 2.33 12.0 @ 4.66
TG2H-28 2.5 28.0 C.T. @ 0.09 14.0 @ 0.18
TG05-28 5 28.0 C.T. @ 0.18 14.0 @ 0.36
TG10-28 10 28.0 C.T. @ 0.36 14.0 @ 0.72
TG20-28 20 28.0 C.T. @ 0.72 14.0 @ 1.44
TG30-28 30 28.0 C.T. @ 1.06 14.0 @ 2.12
TG56-28 56 28.0 C.T. @ 2.00 14.0 @ 4.00
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
TG2H-36 2.5 36.0 C.T. @ 0.07 18.0 @ 0.14
TG05-36 5 36.0 C.T. @ 0.14 18.0 @ 0.28
TG10-36 10 36.0 C.T. @ 0.28 18.0 @ 0.56
TG20-36 20 36.0 C.T. @ 0.56 18.0 @ 1.12
TG30-36 30 36.0 C.T. @ 0.82 18.0 @ 1.64
TG56-36 56 36.0 C.T. @ 1.56 18.0 @ 3.12
† ‡
† ‡
† ‡
† ‡
† ‡
† ‡
Certif.
Agency Certification : † ‡
NOTES:
1. Designed for single input and single output use only
and requires simultaneous use of all windings. 2. The input to the transformer must be fused with an IEC
60127-2 Standard Sheet 3 Time lag (surge-proof)
Low-breaking capacity or Standard Sheet 6 Time lag
(surge-proof) Enhanced breaking capacity fuse. The
fuse value are shown in the Dimensions and Require-
ments Table
www.stancor.com