Features
Regulated
Converters
Wide 4:1 Input Voltage Range
1.6kVDC Isolation for 24Vin and 48Vin,
3kVDC Isolation for 110Vin
Efficiency up to 92%
Six-Sided Continuous Shield
UL60950-1 AM2 Certified, EN50155 Certified
PD-1
REV.: 6/2018www.recom-power.com
DC/DC Converter
3
Y
E
A
R
w
a
r
r
a
n
t
y
3
Description
The RP40-FR series wide range input DC/DC converters have been especially designed for railway
applications and are EN50155 certified. They are also certified to UL60950-1 and cUL 60950-1, this
makes them ideal for all high input voltage telecom and industrial applications where approved safety
standards are required.
40 Watt
2“ x 1“
Single & Dual
Output
RP40-FR
Selection Guide
Part Number Input Output Output Input (1) Efficiency
(1) Max. Capacitive
Voltage Range Voltage Current Current typ. Load (2)
[VDC] [VDC] [mA] [mA] [%] [µF]
RP40-243.3SFR(3,4) 9-36 3.3 10000 1528 90 26600
RP40-2405SFR(3,4) 9-36 5 8000 1832 91 20000
RP40-2412SFR(3,4) 9-36 12 3333 1811 92 3900
RP40-2415SFR(3,4) 9-36 15 2666 1811 92 2600
RP40-2424SFR(3,4) 9-36 24 1666 1831 91 1300
RP40-483.3SFR(3,4) 18-75 3.3 10000 764 90 26600
RP40-4805SFR(3,4) 18-75 5 8000 916 91 20000
RP40-4812SFR(3,4) 18-75 12 3333 906 92 3900
RP40-4815SFR(3,4) 18-75 15 2666 906 92 2600
RP40-4824SFR(3,4) 18-75 24 1666 915 91 1300
RP40-1103.3SFR(3,4) 43-160 3.3 10000 341 88 26600
RP40-11005SFR(3,4) 43-160 5 8000 409 89 20000
RP40-11012SFR(3,4) 43-160 12 3333 402 90.5 3900
RP40-11015SFR(3,4) 43-160 15 2666 400 91 2600
RP40-11024SFR(3,4) 43-160 24 1666 404 90 1300
RP40-2412DFR(3,4) 9-36 ±12 ±1666 1851 90 ±2600
RP40-2415DFR(3,4) 9-36 ±15 ±1333 1851 90 ±1600
RP40-2424DFR(3,4) 9-36 ±24 ±833 1830 91 ±650
RP40-4812DFR(3,4) 18-75 ±12 ±1666 925 90 ±2600
RP40-4815DFR(3,4) 18-75 ±15 ±1333 741 90 ±1600
RP40-4824DFR(3,4) 18-75 ±24 ±833 572 91 ±650
RP40-11012DFR(3,4) 43-160 ±12 ±1666 408 89 ±2600
RP40-11015DFR(3,4) 43-160 ±15 ±1333 408 89 ±1600
RP40-11024DFR(3,4) 43-160 ±24 ±833 400 91 ±650
Model Numbering
Ordering Examples
RP40-2405SFR/P = 24V Input, 5V Output, Positive Logic CTRL pin and Trim pin fitted
RP40-2415SFR/N = 24V Input, 15V Output, Negative Logic CTRL pin and Trim pin fitted
Input Voltage
Output Voltage
Single or Dual
RP40-__ __ _FR/_ _
Notes:
Note1: Values at nominal input voltage and full load
Note2: Test by minimum Vin and constant resistor load.
EN50155 Certified
UL60950-1 AM2 Certified
E196683
Notes:
Note3: standard part is with suffix “P” for positive logic (1=ON, 0=OFF)
or add suffix “N” instead for negative logic (0=ON, 1=OFF)
Note4: add suffix “-HC” for premounted Heat-sink with clamps
Package (4)
CTRL Logic (3)
https://www.recom-power.com/pdf/
Powerline_DC-DC/RSPxxx-168.pdf
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Input Voltage Range
nom. Vin = 24V
nom. Vin = 48V
nom. Vin = 110V
9VDC
18VDC
43VDC
24VDC
48VDC
110VDC
36VDC
75VDC
160VDC
Under Voltage Lockout (UVLO)
Vin = 24V DC-DC ON
DC-DC OFF 8VDC
9VDC
Vin = 48V DC-DC ON
DC-DC OFF 16VDC
18VDC
Vin = 110V DC-DC ON
DC-DC OFF 40VDC
43VDC
Input Filter Pi-Type
Input Reflected Ripple Current nominal Vin and full load 30mAp-p
Input Surge Voltage
Vin =24V, 1s max.
Vin = 48V, 1s max.
Vin = 110V, 1s max.
50VDC
100VDC
170VDC
Start-up time Power up
Remote ON/OFF
60ms
60ms
Internal Operating Frequency 225kHz 250kHz 275kHz
Ripple and Noise measured by 20MHz bandwidth
with a 1µF/50V X7R MLCC
3.3Vout, 5Vout
12Vout, 15Vout
24Vout
75mVp-p
100mVp-p
150mVp-p
100mVp-p
125mVp-p
200mVp-p
ON/OFF CTRL (5)
Positive Logic DC-DC ON
DC-DC OFF
Open or 3.0V < Vr < 12V
Short or 0V < Vr < 1.2V
Negative Logic DC-DC ON
DC-DC OFF
Short or 0V < Vr < 1.2V
Open or 3.0V < Vr < 12V
Input current of Remote pin (CTRL) DC-DC OFF 3mA
DC-DC ON -0.5mA 0.5mA
continued on next page
PD-2 REV.: 6/2018 www.recom-power.com
DC/DC Converter
RP40-FR
Series
Specifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
Notes:
Note5: The pin voltage is referenced to -Vin pin.
Efficiency vs. Output Current Efficiency vs. Input Voltage
9Vin
24Vin
36Vin
Efficiency [%]
Output Current [%]
10
50
40
30
20
10
0
60
70
90
100
20 40 60 80 10030 50 70 90
80
Efficiency [%]
Input Voltage [VDC]
9
100
15 18 24 30 3612 21 27 33
90
80
70
60
50
40
30
20
10
0
RP40-2405SFR
DC/DC Converter
Specifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
REGULATIONS
Parameter
Condition
Value
Output Accuracy full load and nominal Vin ±1.0%
Output Voltage Trimming Single 3.3Vout, 5 Vout, 12Vout
15Vout, 24Vout
±10%
-10% to +20%
Line Regulation low line to high line at full load ±0.2%
Load Regulation 0% to 100% load Single
Dual
±0.5%
±1.0%
Cross Regulation asymmetrical 25%<>100% load ±5.0%
Transient Response 25% load step change 250µs typ.
continued on next page
RP40-FR
Series
PD-3
REV.: 6/2018www.recom-power.com
Efficiency vs. Output Current
Efficiency vs. Output Current
Efficiency vs. Input Voltage
Efficiency vs. Input Voltage
18Vin
48Vin
75Vin
Efficiency [%]
Output Current [%]
10
50
40
30
20
10
0
60
70
90
100
20 40 60 80 10030 50 70 90
80
43Vin
110Vin
160Vin
Efficiency [%]
Output Current [%]
10
50
40
30
20
10
0
60
70
90
100
20 40 60 80 10030 50 70 90
80
Efficiency [%]
Input Voltage [VDC]
18
60
50
40
30
20
10
0
70
80
30 36 48 60 66 7524 42 54 72
90
100
Efficiency [%]
Input Voltage [VDC]
43
60
50
40
30
20
10
0
70
80
62 72 96 125 16014352 84 110 136
90
100
RP40-4805SFR
RP40-11005SFR
continued on next page
PD-4 REV.: 6/2018 www.recom-power.com
DC/DC Converter
Specifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
RP40-FR
Series
External Output Trimming
TRIM UP TRIM DOWN
Output Voltage Trimming
Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using
external trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for
chosing these trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values
to work out the resistor required or use a variable resistor to set the output voltage. Output can be externally trimmed by using the method
shown below.
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 3.333 3.366 3.399 3.432 3.465 3.498 3.531 3.564 3.597 3.63 Volts
RU = 57.93 26.17 15.57 10.28 7.11 4.98 3.48 2.34 1.46 0.75 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 3.267 3.234 3.201 3.168 3.135 3.102 3.069 3.036 3.003 2.97 Volts
RD = 69.47 31.24 18.49 12.12 8.29 5.75 3.92 2.56 1.50 0.65 kOhms
RP40-xx3.3SFR
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 5.05 5.10 5.15 5.20 5.25 5.30 5.35 5.4 5.45 5.50 Volts
RU = 36.57 16.58 9.92 6.89 4.59 3.25 2.30 1.59 1.03 0.59 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 4.95 4.90 4.85 4.80 4.75 4.70 4.65 4.60 4.55 4.50 Volts
RD = 45.533 20.612 12.306 8.152 5.66 3.999 2.812 1.922 1.23 0.676 kOhms
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 12.12 12.24 12.36 12.48 12.60 12.72 12.84 12.96 13.08 13.20 Volts
RU = 367.91 165.95 98.636 64.977 44.782 31.318 21.701 14.488 8.879 4.391 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 11.88 11.76 11.64 11.52 11.40 11.28 11.16 11.04 10.92 10.8 Volts
RD = 460.99 207.95 123.6 81.423 56.118 39.249 27.199 18.162 11.132 5.509 kOhms
RP40-xx05SFR
RP40-xx12SFR
RU
6
5
RD
6
4
DC/DC Converter
Specifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
RP40-FR
Series
PD-5
REV.: 6/2018www.recom-power.com
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 15.15 15.3 15.45 15.60 15.75 15.90 16.05 16.20 16.35 16.50 Volts
RU = 419.81 199.91 126.60 89.95 67.96 53.30 42.83 34.98 28.87 23.98 kOhms
Trim up 11 12 13 14 15 16 17 18 19 20 %
Vout = 16.650 16.800 16.950 17.100 17.250 17.400 17.550 17.700 17.850 18.000 Volts
RU = 19.98 16.65 13.83 11.42 9.32 7.49 5.87 4.43 3.15 1.99 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 14.85 14.70 14.55 14.40 14.25 14.1 13.95 13.8 13.65 13.5 Volts
RD = 284.89 128.68 76.61 50.58 34.96 24.55 17.11 11.53 7.19 3.72 kOhms
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 24.240 24.480 24.720 24.960 25.200 25.440 25.680 25.920 26.160 26.400 Volts
RU = 1275.2 606.60 383.73 272.30 205.44 160.87 129.03 105.15 86.58 71.72 kOhms
Trim up 11 12 13 14 15 16 17 18 19 20 %
Vout = 26.640 26.880 27.120 27.360 27.600 27.840 28.080 28.320 28.560 28.800 Volts
RU = 59.56 49.43 40.86 33.51 27.15 21.57 16.66 12.29 8.38 4.86 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 23.760 23.520 23.280 23.040 22.800 22.560 22.320 22.080 21.840 21.600 Volts
RD = 838.15 376.78 222.98 146.09 99.95 69.19 47.22 30.74 17.93 7.68 kOhms
RP40-xx15SFR
RP40-xx24SFR
PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) continuous, automatic recovery
Over Voltage Protection (OVP) Zener Diode Clamp
3.3Vout
5Vout
12Vout
15Vout
24Vout
3.9VDC
6.2VDC
15VDC
20VDC
30VDC
Over Load Protection (OLP) % Iout rated 150% typ., Hiccup Mode
Over Temperature Protection (OTP) 115°C
Isolation Voltage
24Vin, 48Vin I/P to O/P
I/P to O/P to Case
1.6kVDC/1min.
1.6kVDC/1min.
110Vin I/P to O/P
I/P to O/P to Case
3kVDC/1min.
1.6kVDC/1min.
Isolation Resistance 500VDC 1G min.
Isolation Capacitance 1500pF max.
Notes:
Note6: This power module is not internally fused. An input line fuse must always be used.
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety E196683 UL60950-1, 2nd Edition AM:2, 2014
CSA C22.2 No. 60950-1-07
Railway Applications - Electrical Equipment used on rolling stock 15A100702E-C EN50155, 2007
EMI Compliance Condition Standard / Criterion
Industrial, scientific and medical equipment - Radio frequency disturbance
characteristics - Limits and methods of measurement (8) with external filter EN50121-3-2, Class A
EN55011, Class A or B
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity (9)
Surge Immunity (9)
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
Air ±8kV and Contact ±6kV
20 V/m
±2kV
±2kV
10 Vr.m.s
100A/m continuous; 1000A/m 1s
EN61000-4-2, Criteria A
EN61000-4-3, Criteria A
EN61000-4-4, Criteria A
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
EN61000-4-8, Criteria A
continued on next page
PD-6 REV.: 6/2018 www.recom-power.com
DC/DC Converter
Specifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
RP40-FR
Series
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range without derating, without Heat-Sink
with derating
-40°C to +60°C
-40°C to +105°C
Maximum Case Temperature +105°C
Temperature Coefficient ±0.02%/°C max.
Thermal Impedance Natural convection, without Heat-sink
Natural convection, with Heat-sink
10.8°C/W
10.3°C/W
Operating Humidity 5% - 95% RH
Shock EN61373, MIL-STD-810F
Thermal Shock MIL-STD-810F
Vibration EN61373, MIL-STD-810F
Fire protection on railway vehicles according to EN45545-2, 2013 standard
MTBF according to MIL-HDBK-217F standard 907.3 x 103h
Notes:
Note7: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-
number not shown here please contact our technical support service at techsupportAT@recom-power.com
-40 60 80 100
105
12040
200-20
0
20
40
60
80
100
Ambient Temperature [°C]
Output Power [%]
-40 60 80
65 100
105 12040
200-20
0
20
40
60
80
100
Ambient Temperature [°C]
Output Power [%]
RP40-2415SFR RP40-2415SFR-HC
Derating Graph(7)
(@ Chamber and natural convection 0.1m/s)
continued on next page
DC/DC Converter
Specifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
RP40-FR
Series
PD-7
REV.: 6/2018www.recom-power.com
Notes:
Note8: The standard module meets EMI Class A or Class B with external components.
Note9: An external input filter capacitor is required if the module has to meet EN61000-4-4 and -4-5.
The RP40-24xxFR requires an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS (SMDJ58A,
58V, 3000Watt peak pulse power) connected in parallel.
The RP40-48xxFR requires an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS
(SMDJ120A,120V, 3000Watt peak pulse power) connected in parallel.
The RP40-110xxFR requires 3pcs aluminum electrolytic capacitor in parallel (Ruby-con BXF series, 68µF/200V) and two TVS
(SMDJ90A, 90V, 3000Watt peak pulse power) in series, connected in parallel.
EMC Filtering according to EN50121-3-2(Single Outputs)
EMC Filtering according to EN50121-3-2 (Dual Outputs)
MODEL TVS1 TVS2 C1(9) C2 C3 C4 C5, C6, C7 L1
RP40-24xxS_DFR
SMDJ58A
58V, 3000W
peak pulse power N/A 220µF/100V N/A N/A
10µF/50V
1210 MLCC 680pF/3kV
1808 MLCC
2.2µH 11A
SMD-Inductor
RP40-48xxS_DFR
SMDJ120A
120V, 3000W
peak pulse power
4.7µF/100V
1210 MLCC
12µH 4A
SMD-Inductor
RP40-110xxS_DFR
SMDJ90A
90V, 3000W
peak pulse power
SMDJ90A
90V, 3000W
peak pulse power
68µF/200V
3 in parallel
33µF/250V
Al Cap. (lie down)
Chemi-con KXJ
1µF/250V
1812 MLCC
1µF/250V
1812 MLCC
1000pF
TDK CD series
Y1
22µH 1.5A
SMD-Inductor
C4
C2 C3
+VIN
-VIN
+VIN
-VIN
LOAD
C6
C5
C7
LOADLOAD
L1
C4
C6
C5
C7
L1
C2
C1
(9)
C3
TVS1
(9)
TVS2
(9)
C1
(9)
TVS1
(9)
TVS2
(9)
PD-8 REV.: 6/2018 www.recom-power.com
DC/DC Converter
Specifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
RP40-FR
Series
continued on next page
EMC Filtering according to EN55022 Class A (Single Outputs)
EMC Filtering according to EN55022 Class A (Dual Outputs)
MODEL C1 C2 C3 C4 C5 C6 C7 C8 L1
RP40-24xxS_DFR 10µF/50V
1210 MLCC N/A N/A N/A
10µF/50V
1210 MLCC 680pF/3kV
1808 MLCC
2.2µH 11A
SMD Inductor
RP40-48xxS_DFR 4.7µF/100V
1210 MLCC
4.7µF/100V
1210 MLCC
12µH 4A
SMD Inductor
RP40-110xxS_DFR N/A
33µF/250V
Al Cap. (lie down)
Chemi-con KXJ
1µF/250V
1812 MLCC
1000pF
TDK CD series
Y1
22µH 1.5A
SMD Inductor
Fuse
C5
+VIN
-VIN
LOAD
C7
C6
C8
LOADLOAD
L1
C5
C7
C6
C8
C1 C3 C4C2
Fuse
+VIN
-VIN
L1
C1 C3 C4C2
DC/DC Converter
Specifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
RP40-FR
Series
PD-9
REV.: 6/2018www.recom-power.com
continued on next page
Fuse
C2
+VIN
-VIN
LOAD
C7
C6
C4
C5
L2
L1
LOADLOAD
C1 C3
Fuse
C2
+VIN
-VIN
C7
C6
C4
C5
L2
L1
C1 C3
MODEL C1/C2 C3 C4/C6 C5/C7 L1/L2
RP40-24xxS_DFR 10µF/50V
1210 MLCC 82µF/100V
Al Cap. (lie down)
Chemi-con KJ
1000pf/3kV
1808 MLCC
2200pf/3kV
1808 MLCC
3.3µH 10A
SMD Inductor
RP40-48xxS_DFR 4.7µF/100V
1210 MLCC
12µH 4A
SMD Inductor
EMC Filtering according to EN55022 Class B (24Vin and 48Vin, Single Outputs)
EMC Filtering according to EN55022 Class B (24Vin and 48Vin, Dual Outputs)
PD-10 REV.: 6/2018 www.recom-power.com
DC/DC Converter
Specifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
RP40-FR
Series
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter Type Value
Material
Case
Base
Potting
Copper Alloy CuZn33
FR4 PCB
Silicone (UL94V-0)
Packaging Dimension (LxWxH) without Heat-sink
with Heat-sink
50.8 x 25.4 x 10.2mm
56.8 x 25.4 x 16.8mm
Packaging Weight without Heat-sink
with Heat-sink
32g
43g
continued on next page
Fuse
C1 C3 C5 C6
+VIN
-VIN
LOAD
C9
C8
C9
C8
C7
C7
L2
L1
LOADLOAD
C2 C4
Fuse
C1 C3 C5 C6
+VIN
-VIN
L2
L1
C2 C4
MODEL C1 C2/C3 C4 C5/C6 C7/C8/C9 L1/L2
RP40-110xxS_DFR
33µF/250V
Al Cap. (lie down)
Chemicon -KXJ
1µF/250V
1812 MLCC
33µF/250V
Al Cap. (lie down)
Chemicon -KXJ
1µF/250V
1812 MLCC
2200pF
TDK CD series Y1
22µH 1.5A
SMD Inductor
EMC Filtering according to EN55022 Class B (110Vin Single Outputs)
EMC Filtering according to EN55022 Class B (110Vin Dual Outputs)
PACKAGING INFORMATION
Parameter Type Value
Packaging Quantity without Heat-sink
with Heat-sink
Tube
Tray
9pcs
20pcs
Storage Temperature Range -55°C to +125°C
Storage Humidity 5% - 95% RH
Pin Connections
Pin # Single Dual
1 +Vin +Vin
2 -Vin -Vin
3 CTRL CTRL
4 +Vout +Vout
5 -Vout Com
6 Trim -Vout
Pin Pitch Tolerance ±0.25mm
Pin dimension tolerance ±0.1mm
XX.X ± 0.5mm
XX.XX ± 0.25mm
Dimension Drawing (mm)
Dimension Drawing with Heat-sink (mm)
3
2
1
6
5
4
Bottom View
10.2
50.8
45.72
25.4
5.6
5.08
15.24
25.4
5.1
2.54
7.62
17.78
ø1.0
ø1.0
10.2
16.8
25.4
5.6
24.20
50.00
5.85
1.40 1.30
1.60 1.30
Top View
45.72
56.8
DC/DC Converter
Specifications (measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
RP40-FR
Series
PD-11
REV.: 6/2018www.recom-power.com
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.