1-480
H
VDE 0884 VIORM = 630 V peak
Option for Plastic Optocouplers
Technical Data
Option 060
Description
Optocouplers are frequently used
to provide high voltage insulation.
Because optocouplers perform
this safety function, they are
regulated by many country safety
agencies, both at the component
level and the equipment level.
With Option 060, the products
are tested according to VDE 0884
(June 1992 Revision) at
VIORM = 630 V peak. HP also
offers other various VDE 0884
approved products at different
levels of VIORM such as
VIORM = 1414 kV peak
(HCNWXXXX series) and
VIORM = 891 V peak (HCPL-JXXX
series).
Refer to the front of the opto-
coupler section of the current
catalog, under Product Safety
Regulations section, for a detailed
description of VDE 0884 and the
partial discharge tests for
production and type testing.
Option 060 is available on the
following products.
HCPL-2211 HCPL-2212
HCPL-2219 HCPL-2300
HCPL-2400 HCPL-261A
HCPL-261N HCPL-2611
HCPL-3120 HCPL-3150
HCPL-4503 HCPL-4504
HCPL-4506 HCPL-4701
Contact your local HP Sales
Representative concerning
availablility of this option for
optocouplers not listed.
Ordering Information
Specify Part Number followed by
Option Number.
Example
HCPL-3120#060
Marketing Information
Insulation Related Specifications
Parameter Symbol Value Units Conditions
Minimum External Air L(101) 7.1 mm Measured from input terminals to output
Gap (External Clearance) terminals, shortest distance through air.
Minimum External Track- L(102) 7.4 mm Measured from input terminals to output
ing (External Creepage) terminals, shortest distance path along body.
Minimum Internal 0.08 mm Through insulation distance, conductor to
Plastic Gap conductor, usually the direct distance between
(Internal Clearance) the photoemitter and photodetector inside the
optocoupler cavity.
Tracking Resistance CTI 200 V DIN IEC 112/VDE 0303 Part 1
(Comparative
Tracking Index)
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
HP 3120V
9624
EXAMPLE:
HCPL-3120 #060
4 DIGITS
DATE CODE
5965-3572E
1-481
VDE 0884 Insulation Related Characteristics (Option 060)
*85°C
HCPL-2211, HCPL-2212, HCPL-2219, HCPL-2300, HCPL-2400, HCPL-2611, HCPL-261A,
HCPL-261N, HCPL-4701.
**100°C
HCPL-3120, HCPL-3150, HCPL-4503 HCPL-4504, HCPL-4506.
Description Symbol Characteristic Units
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage 300 V rms I-IV
for rated mains voltage 450 V rms I-III
Climatic Classification 55/85/21*
55/100/21**
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage VIORM 630 V peak
Input to Output Test Voltage, Method b†
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec, VPR 1181 V peak
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a†
VIORM x 1.5 = VPR, Type and Sample Test, VPR 945 V peak
tm = 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage†
(Transient Overvoltage, tini = 10 sec) VIOTM 6000 V peak
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Thermal Derating curve, Figure 1.)
Case Temperature TS175 °C
Input Current IS,INPUT 230 mA
Output Power PS,OUTPUT 600 mW
Insulation Resistance at TS, VIO = 500 V RS109
†Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section (VDE 0884), for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in
application.
Figure 1. Thermal Derating Curve, Dependence of Safety
Limiting Value with Case Temperature per VDE 0884.
OUTPUT POWER – P
S
, INPUT CURRENT – I
S
0
0
T
S
– CASE TEMPERATURE – °C
20050
400
12525 75 100 150
600
800
200
100
300
500
700 P
S
(mW)
I
S
(mA)
175
(230)