LD-P (ALDP)
1
ds_61B10_en_ldp: 010611D
ORDERING INFORMATION
TYPES
Packing quantity: inner 100 pieces, outer 500 pieces
RATING
1. Coil data
1 Form A 5A
Slim size (7 mm)
Power Relay
LD-P RELAYS (ALDP)
Contact arrangement Nominal coil voltage Part No.
1 Form A
5V DC ALDP105
6V DC ALDP106
9V DC ALDP109
12V DC ALDP112
18V DC ALDP118
24V DC ALDP124
Nominal coil
voltage
Pick-up voltage
(at 20C 68F)
Drop-out voltage
(at 20C 68F)
Nominal operating
current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Nominal operating
power
Max. allowable voltage
(at 20C 68F)
5V DC
75%V or less of
nominal voltage
(Initial)
5%V or more of
nominal voltage
(Initial)
40.0mA 125
200mW 130%V of
nominal voltage
6V DC 33.3mA 180
9V DC 22.2mA 405
12V DC 16.7mA 720
18V DC 11.1mA 1,620
24V DC 8.3mA 2,880
VDE
Protective construction: Sealed type
FEATURES
1. Nominal switching capacity:
5A 277V AC
2. Ambient temperature:
–40C to +85C –40F to +185F
3. Excellent heat resistance and
tracking performance:
EN60695 (GWT2-11, GWFI2-12,
GWIT2-13) data available
(Please consult us for details.)
4. Slim type:
20.3 (L) 7.0 (W) 15 (H) mm .799 (L)
.276 (W) .591 (H) inch
5. High insulation resistance:
• Creepage distance and clearances
between contact and coil: Min. 6 mm .236
inch (In compliance with IEC65)
• Surge withstand voltage between
contact and coil: 10,000 V or more.
TYPICAL APPLICATIONS
• Boilers
• Air conditioner
• Refrigerator
• Hot water units
• Microwave ovens
• Fan heaters
LD-P relay
ALDP 1
Coil voltage (DC)
05: 5V, 06: 6V, 09: 9V, 12: 12V, 18: 18V, 24: 24V
Contact arrangement
1: 1 Form A
Note: UL, C-UL and VDE approved type is standard.
Packing style
Nil: Tube packing
W: Carton packing
LD-P (ALDP)
2ds_61B10_en_ldp: 010611D
2. Specifications
Notes:
*1This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
REFERENCE DATA
Characteristics Item Specifications
Contact
Arrangement 1 Form A
Contact resistance (Initial) Max. 100 m (By voltage drop 6 V DC 1A)
Contact material AgNi type
Rating
Nominal switching capacity (resistive load) 5A 277V AC
Max. switching power (resistive load) 1,385VA
Max. switching voltage 277V AC
Max. switching current 5A
Min. switching capacity (reference value)*1100mA 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 750 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*2
(Between contact and coil) 10,000 V (initial)
Temperature rise Max. 30C 86F (By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 5A, at 85C 185F)
Operate time (at nominal voltage) (at 20C 68F) Max. 10 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20C 68F) Max. 10 ms (excluding contact bounce time) (With diode)
Mechanical
characteristics
Shock resistance Functional Min. 300 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Destructive Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life Mechanical (at 180 cpm) Min. 5106
Electrical (at 20 cpm) Min. 2105 (5A 125V AC at rated load), Min. 105 (5A 250V AC at rated load)
Conditions
Conditions for operation, transport and storage*3Ambient temperature: –40C to +85C –40F to +185F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed
(at nominal switching capacity) 20 cpm
Unit weight Approx. 4 g .14 oz
1. Max. switching power 2. Life curve 3. Coil temperature rise
Sample: ALDP112, 6 pcs.
Point measured: inside the coil
Contact current: 0 A, 5 A
10 100
10
5
1
0.1
Contact voltage, V
Contact current, A
AC resistive load
6543210
100
10
1
Contact current, A
125V AC resistive load
250V AC resistive load
Life, ×104
5A*
0A*
14012010080
50
40
30
20
10
Coil applied voltage, %V
Temperature rise, °C
*at room temperature
85°C 5A
85°C 0A
4-(1). Operate time
Sample: ALDP112, 30 pcs.
4-(2). Release time (without diode)
Sample: ALDP112, 30 pcs.
4-(3). Release time (with diode)
Sample: ALDP112, 30 pcs.
Max.
Min.
1401201008060
10
8
6
4
2
0
Coil applied voltage, %V
Operate time, ms
Max.
Min.
1401201008060
10
8
6
4
2
0
Coil applied voltage, %V
Release time, ms
Max.
Min.
1401201008060
10
8
6
4
2
0
Coil applied voltage, %V
Release time, ms
LD-P (ALDP)
3
ds_61B10_en_ldp: 010611D
DIMENSIONS (mm inch)
SAFETY STANDARDS
Certification authority
UL, C-UL 5A 277V AC 70C
5A 30V DC
VDE 5A 250V AC cos = 1.0 70C
5A 30V DC 0ms
5. Electrical life test
(5A 250V AC Resistive load)
Sample: ALDP112, 6 pcs.
Operation frequency: 20 times/min.
(ON:OFF = 1.5s:1.5s)
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
Contact welding
detection and
Mis-contacting
detection circuit
250V AC
12V DC
Max.
Min.
Max.
Min.
Pick-up and drop-out voltage, V
No. of operations, ×104
Drop-out voltage
Pick-up voltage
100
10
9
8
7
6
5
4
3
2
1
0
Max.
Min.
No. of operations, ×104
100
100
90
80
70
60
50
40
30
20
10
0
Contact resistance, mΩ
Download from our Web site.
CAD Data
CAD Data
CAD Data
1.15
4.7
.185 .045
Max. 7.2
Max. 20.5
Max. 15.3
Max. .602
Max. .807 Max. .283
0.8
.031
3.4
.134
0.2
.008
0.2
.008
0.4 dia.
.016 dia.
1.05 11.5 7.0
.453 .276
.041
0.4
.016
Dimension: General tolerance
Max. 1mm .039 inch:0.1 .004
1 to 3mm .039 to .118 inch:0.2 .008
Min. 3mm .118 inch:0.3 .012
PC board pattern (Bottom view)
Tolerance: 0.1 .004
Schematic (Bottom view)
11.5
(1.05)
(.041)
(1.15)
(.045)
4.7
.185
.453 7.0
.276 4-1.1 dia.
4-.043 dia.
NOCOM
COIL
LD-P (ALDP)
4ds_61B10_en_ldp: 010611D
NOTES
For Cautions for Use, see Relay Technical Information.
Usage, transport and storage
conditions
1) Temperature:
–40 to +85C –40 to +185F
2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for
usage, transport, and storage
4) Condensation
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
5) Freezing
Condensation or other moisture may
freeze on the relay when the
temperatures is lower than 0C 32F.
This causes problems such as sticking of
movable parts or operational time lags.
6) Low temperature, low humidity
environments
The plastic becomes brittle if the relay is
exposed to a low temperature, low
humidity environment for long periods of
time.
Solder and cleaning conditions
1) Please obey the following conditions
when soldering automatically.
(1) Preheating: Within 120C 248F
(solder surface terminal portion) and
within 120 seconds
(2) Soldering iron: 260C5C
500F41F (solder temperature) and
within 6 seconds (soldering time)
2) Do not use ultrasonic cleaning.
This will adversely affect the relay
characteristics. Also, it is recommended
that alcoholic solvents be used.
Certification
1) This relay is UL and C-UL certified.
UL and C-UL standards:
5 A 277 V AC 70C
5 A 30 V DC
2) This relay is certified by VDE.
VDE standards:
5 A 250 V AC cos = 1.0 70C
5 A 30 V DC 0ms
3) UL, C-UL and VDE certified ratings are
displayed on the packaging box.
(On the relay, only the certification marks
are shown and not the certified ratings.
Please refer to the product specification
diagrams to see what is stamped.)
Part number display
The “W” at the end of the part number
only appears on the inner and outer
packaging. It does not appear on the
relay itself.
Others
1) To ensure good operation, please
keep the voltage on the coil ends to 5%
(at 20C 68F) of the rated coil operation
voltage. Also, please be aware that the
pick-up voltage and drop-out voltage may
change depending on the temperature
and conditions of use.
2) Keep the ripple rate of the nominal coil
voltage below 5%.
3) The cycle lifetime is defined under the
standard test condition specified in the
JIS C 5442 standard (temperature 15 to
35C 59 to 95F, humidity 25 to
75%R.H.). Check this with the real device
as it is affected by coil driving circuit, load
type, activation frequency, activation
phase, ambient conditions and other
factors.
Also, be especially careful of loads such
as those listed below.
(1) When used for AC load-operating and
the operating phase is synchronous.
Rocking and fusing can easily occur due
to contact shifting.
(2) Highly frequent load-operating
When highly frequent opening and
closing of the relay is performed with a
load that causes arcs at the contacts,
nitrogen and oxygen in the air is fused by
the arc energy and HNO3 is formed. This
can corrode metal materials.
Three countermeasures for these are
listed here.
• Incorporate an arc-extinguishing circuit.
• Lower the operating frequency
• Lower the ambient humidity
4) Minimum switching capacity is a
guideline as to the lowest possible level
at which it will be possible for a low level
load to allow switching. This value can
change due to the switching frequency,
environmental conditions, and desired
reliability level, therefore it is
recommended to check this with the
actual load.
5) Heat, smoke, and even a fire may
occur if the relay is used in conditions
outside of the allowable ranges for the
coil ratings, contact ratings, operating
cycle lifetime, and other specifications.
Therefore, do not use the relay if these
ratings are exceeded.
6) If the relay has been dropped, the
appearance and characteristics should
always be checked before use.
7) Incorrect wiring may cause
unexpected events or the generation of
heat or flames.
8) Creepage distance and clearances
between contact and coil: Min. 6 mm
85
5
Humidity, %RH
Tolerance range
(Avoid
condensation
when used at
temperatures
higher than
0°C32°F)
(Avoid freezing
when used at
temperatures
lower than
0°C32°F)
850-40 +185+32-40
Temperature, °C°F