INTEGRATED CIRCUITS DIVISION
www.ixysic.com
2R02
LCB710
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
AC/DC Configuration, Continuous IF=0mA IL
--1
Arms / ADC
DC Configuration, Continuous - - 2 ADC
Peak IF=0mA , t < 10ms ILPK --±5 A
P
On-Resistance 1
IF=0mA, IL=1A - 0.39 0.6 AC/DC Configuration RON
DC Configuration IF=0mA, IL=2A - 0.1 0.2
Switching Speeds
Turn-On ton - 0.63 3
IF=5mA, VL=10V ms
Turn-Off toff - 1.5 3
Off-State Leakage Current IF=2mA, VL=60V ILEAK --1 A
Output Capacitance IF=2mA, VL=50V, f=1MHz COUT - 125 - pF
Input Characteristics
Input Control Current to Activate IL=1A IF- 0.22 2 mA
Input Control Current to Deactivate - IF0.1 0.21 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10 A
Common Characteristics
Capacitance, Input to Output - CI/O -3- pF
1 Measurement taken within 1 second of on-time.
Parameter Ratings Units
Blocking Voltage 60 VP
Reverse Input Voltage 5 V
Input Control Current
Peak (10ms)
50 mA
1A
Input Power Dissipation 1100 mW
Total Power Dissipation 2800 mW
Isolation Voltage, Input to Output 3750 Vrms
ESD Rating, Human Body Model 8 kV
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Absolute Maximum Ratings @ 25ºC