SPECIFICATION
PSP-500-5 PSP-500-12 PSP-500-13.5 PSP-500-15 PSP-500-24 PSP-500-27 PSP-500-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
VOLTAGE RANGE Note.6
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
HARMONIC CURRENT
EMS IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
REMOTE CONTROL
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER LOAD
FUNCTION
AC CURRENT (Typ.)
5V 12V 13.5V 15V 24V 27V 48V
80A 41.5A 37A 33A 20.8A 18.5A 10.5A
0 ~ 80A 0 ~ 41.5A 0 ~ 37A 0 ~ 33A 0 ~ 20.8A 0 ~ 18.5A 0 ~ 10.5A
400W 498W 499.5W 495W 499.2W 499.5W 504W
100mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p
4.75 ~ 5.5V 10 ~ 13.2V 12 ~ 15V 13.5 ~ 18V 20 ~ 26.4V 24 ~ 30V 41 ~ 56V
2.0%
2.0%
1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
0.5% 0.3% 0.3% 0.3% 0.2% 0.2%
0.2%
0.5% 0.5% 0.5% 0.5% 0.5%
0.5%
1500ms, 50ms at full load
24ms at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
0.95/230VAC 0.98/100VAC at full load
76% 82% 82% 82% 84% 84% 86%
7A/115AVC 3.5A/230VAC
20A/115VAC 40A/230VAC
<1mA / 240VAC
110 ~ 125% rated output power
5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V 31 ~ 36.5V 57.6 ~ 67.2V
Protection type : Constant current limiting, recovers automatically after fault condition is removed
UL60950-1, TUV EN60950-1 Approved
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH with 30CFM forced air non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
130.1K hrs min. MIL-HDBK-217F (25 )
278*129*63.5mm (L*W*H)
2.6Kg; 6pcs/15.7Kg/0.89CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. In parallel connection, maybe only one unit operated, if the total output load less than 5% of rated load condition.
6. Derating may be needed under low input voltages. Please check the derating curve for more details.
RC+/RC-: 0 ~ 0.8V=power on ; 4 ~ 10V=power off sink current <4 ~ 10mA
OVER VOLTAGE
OVER TEMPERATURE RTH2 95 Detect on heatsink of Q1,Q7 power transistor & L3 output choke
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
500W with PFC and Parallel Function PSP-500 series
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections:Short circuit/Over load/Over voltage/Over temperature
Foced air cooling by built-in DC fan
Current sharing up to 2000W(3+1)
With power good and fail signal output
Built-in remote ON-OFF control
Built-in remote sense function
3 y e a r s w a r r a n t y
Features :
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
EMI CONDUCTION & RADIATION