JJM
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Please refer to “Usage ambient
condition” in CAUTIONS FOR USE OF AUTOMOTIVE RELAYS.
Please inquire if you will be using the relay in a high temperature atmosphere (110°C 230°F).
*3. Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions.
REFERENCE DATA
Characteristics Item Specifications
Contact
Arrangement 1 Form A 1 Form C
Contact resistance (Initial) Typ 5mΩ (By voltage drop 6V DC 1A)
Contact material Ag alloy (Cadmium free)
Rating
Nominal switching capacity
(resistive load) 20 A 14V DC N.O.: 20 A 14V DC
N.C.: 10 A 14V DC
Max. carrying current (12V DC)*3N.O.: 35 A (at 20°C 68°F for 2 minutes), 25 A (at 20°C 68°F for 1 hour),
30 A (at 85°C 185°F for 2 minutes), 20 A (at 85°C 185°F for 1 hour)
Nominal operating power 640 mW
Min. switching capacity
(resistive load)*11 A 12V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 100 MΩ (at 500V DC, Measurement at same location as “Break down voltage” section)
Breakdown
voltage (Initial)
Between open
contacts 500 Vrms for 1 min. (Detection current: 10mA)
Between contacts
and coil 500 Vrms for 1 min. (Detection current: 10mA)
Operate time (at nominal voltage) Max. 10ms (at 20°C 68°F, excluding contact bounce time) (Initial)
Release time (at nominal voltage) Max. 10ms (at 20°C 68°F, excluding contact bounce time) (Initial)
Mechanical
characteristics
Shock
resistance
Functional Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Destructive Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms)
Vibration
resistance
Functional 10 Hz to 100 Hz, Min. 44.1 m/s2 {4.5G} (Detection time: 10µs)
Destructive 10 Hz to 500 Hz, Min. 44.1 m/s2 {4.5G},
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Expected life
Mechanical Min. 107 (at 120 cpm)
Electrical
<Resistive load>
Min. 105 (at nominal switching capacity)
(operating frequency: 1s ON, 9s OFF)
<Motor load>
Min. 2 × 105 (at Inrush 25A, Steady 5A 14 V DC)
Min. 5 × 104 (at 20A 14 V DC motor lock)
(operating frequency: 0.5s ON, 9.5s OFF)
<Resistive load>
N.O.: Min. 105 (at nominal switching capacity)
N.C.: Min. 105 (at nominal switching capacity)
(operating frequency: 1s ON, 9s OFF)
<Motor load>
N.O.: Min. 2 × 105 (at Inrush 25A, Steady 5A 14 V DC),
Min. 5 × 104 (at 20A 14 V DC motor lock)
N.C.: Min. 2 × 105 (at 20A 14 V DC brake currect)
(operating frequency: 0.5s ON, 9.5s OFF)
Conditions
Conditions for operation, transport and
storage*2
Ambient temperature: –40°C to +85°C –40°F to +185°F,
Humidity: 5% R.H. to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 6 cpm (at nominal switching capacity)
Mass Approx. 5g .176 oz
1. Coil temperature rise
Sample: JJM1-12V, 6pcs
Point measured: Inside the coil
Contact current: Non current through
contact, 5A, 10A, 15A, 20A
Resistance method, ambient temperature 85°C 185°F
2. Max. switching capability
(Resistive load, initial)
3. Ambient temperature and operating voltage
range
0
20
40
60
80
100
120
12 14 16
Temperature rise, °C
Coil applied voltage, V
20A
15A
10A
5A
Non current
through
contact
0
10
50
40
30
20
60
020304010 50
(N.O. side: room temperature)
Switching current, A
Switching voltage, VDC
0
5
10
15
35
30
25
20
40
−40 −20 20 40 60 1000 120
8085
Coil applied voltage, VDC
Ambient temperature, °C
Pick-up voltage
(cold start)
ASCTB234E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e