Radial Through-Hole Ceramic Disc Capacitors Safety Standard Recognized, 900 Series, Radial Disc, Encapsulated, AH Type, X1 400 VAC/Y1 250 VAC (Industrial Grade) Overview KEMET's 900 series encapsulated radial through-hole ceramic disc capacitors are specifically designed for interferencesuppression AC line filtering applications. Having internationally recognized safety certifications, these capacitors are well-suited for applications that require keeping potentially disruptive or damaging line transients and EMI out of susceptible equipment. They are also an ideal solution when needing to suppress line disturbances at the source. With a working voltage of 400 VAC in line-to-line (Class X)and 250 VAC in line-to-ground (Class Y) applications, these safety capacitors meet the impulse test criteria outlined in IEC Standard 60384. Meeting subclass X1 and Y1 requirements, these devices are certified to withstand impulses up to 4 KV (X1) and 8 KV (Y1) respectively. These encapsulated devices also meet the flame test requirements outlined in UL Standard 94V-0. Safety Certified Capacitors are classified as either X and/or Y capacitors. Class X capacitors are primarily used in line-to line (across-the-line) applications. In this application there is no danger of electric shock to humans should the capacitor fail, but could result in a risk of fire. The class Y capacitor is primarily used in line-to-ground (line by-pass) applications. In this application, failure of the capacitor could lead to danger of electric shock. Ordering Information C9 1 1 U 620 J U Ceramic Series Body Diameter Lead Spacing1 Spec. Capacitance Code (pF) Capacitance Tolerance Rated Voltage 2 significant digits + Number of zeroes Use 9 for 1.0 9.9pF e.g., 2.2pF = 229 C = 0.25pF D = 0.5pF J = 5% K = 10% M = 10% U = X1 400 VAC / Y1 250 VAC C9 = Ceramic 900 Series 0 = 7.0 mm 1 = 10.0 mm U = 1 = 8.0 mm Safety 2 = 9.0 mm 3 = 10.0 mm 4 = 11.0 mm 5 = 12.0 mm 7 = 14.0 mm S D Dielectric/ Design Temp. Char. N = CH (NP0) S = SL Y = Y5P W = Y5U V = Y5V D= Disc A A 7317 Lead Config.2 Failure Rate Packaging (C-Spec)1,2 A= N/A 7317 = Ammo Pack WL30 = Bulk/3.0 mm Lead length WL35 = Bulk/3.5 mm Lead length WL40 = Bulk/4.0 mm Lead length WL45 = Bulk/4.5 mm Lead length WL50 = Bulk/5.0 mm Lead length WL20 = Bulk/20 mm Lead length A= Straight B= Vertical Kink C= Outside Kink 1 "Vertical Kink" and "Outside Kink" lead configurations cannot be combined with the bulk/20 mm lead length option (WL20). 20 mm lead length is only available on capacitors ordered with straight leads (lead configuration ordering code "A"). For nonstandard lead length inquiries, please contact KEMET. 2 Bulk packaging lead length availability is dependent upon "Lead Configuration." See "Dimensions" section of this document to verify availability of a specific lead length option. For nonstandard lead length inquiries, please contact KEMET. One world. One KEMET (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 (864) 963-6300 * www.kemet.com C1067_X1_400 VAC_Y1_250 VAC * 11/14/2013 1 Radial Through-Hole Ceramic Disc Capacitors Safety Standard Recognized, 900 Series, Radial Disc, Encapsulated, AH Type, X1 400 VAC/Y1 250 VAC (Industrial Grade) Lead Configurations Straight Vertical Kink Outside Kink Dimensions - Millimeters Lead Config. F Lead Lead Config. Packaging Spacing Lead Ordering Type Tolerance Spacing 1 Code Ammo Pack Straight A 10.0 1.0 Bulk Ammo Pack Vertical Kink (Preformed) B 10.0 1.0 Bulk Ammo Pack Outside Kink (Preformed) C 10.0 1.0 Bulk L Lead Length D T e Packaging C-Spec Body Body Lead Ordering Diameter Thickness Meniscus Code2 20.0 +1.5/-1.0 7317 3.0 1.0 WL30 4.5 1.0 WL45 5.0 1.0 WL50 20.0 minimum WL20 18.0 +2.0/-0 7317 3.5 1.0 WL35 4.0 1.0 WL40 18.0 +2.0/-0 7317 3.5 1.0 WL35 4.0 1.0 WL40 5.0 1.0 WL50 See Table 1 - "Product Ordering Codes and Ratings" 3.0 maximum Od Lead Dia. 0.5 0.1 Lead Configuration is identified in the 13th character of the ordering code. See "Lead Configuration" and "Ordering Information" sections of this document for further details. 2 The "Packaging C-Spec" is a 4-digit numeric or alphanumeric code which identifies both the packaging type and lead length requirement. When ordering, this code must be included in the 15th through 18th character positions of the ordering code. See "Ordering Information" section of this document for further details. 1 (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 (864) 963-6300 * www.kemet.com C1067_X1_400 VAC_Y1_250 VAC * 11/14/2013 2 Radial Through-Hole Ceramic Disc Capacitors Safety Standard Recognized, 900 Series, Radial Disc, Encapsulated, AH Type, X1 400 VAC/Y1 250 VAC (Industrial Grade) Benefits * * * * * * * * * * * * * Safety Standard Recognized (IEC 60384-14) Reliable operation up to 125C Class X1/Y1 10 mm lead spacing Lead (Pb)-free and RoHS Compliant Halogen Free Capacitance offerings ranging from 2.0 pF up to 4,700 pF Available capacitance tolerances of 0.25 pF, 0.5 pF, 5%, 10%, and 20% High reliability Preformed (crimped) or straight lead configurations Non-polar device, minimizing installation concerns 100% pure matte tin-plated lead finish allowing for excellent solderability Encapsulation meets flammability standard UL 94V-0 Applications Typical applications include: * Line-to-line (Class X) filtering * Line-to-ground (Class Y) filtering * Antenna coupling * Primary and secondary coupling (switching power supplies) * Line disturbances suppression (motors and motor controls, relays, switching power supplies, and inverters) Approval Standard and Certification No. Safety Standard Standard No. VDE (ENEC) IEC 60384-14 Subclass Working Voltage X1 400 VAC Y1 250 VAC Certificate No. 40036417 These devices are VDE/ENEC recognized for antenna coupling and AC line-to-line (Class X) and line-to-ground (Class Y) applications per IEC60384-14. Environmental Compliance These devices are Halogen Free and RoHS Compliant. They meet all requirements set forth by both EU and China RoHS directives. (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 (864) 963-6300 * www.kemet.com C1067_X1_400 VAC_Y1_250 VAC * 11/14/2013 3 Radial Through-Hole Ceramic Disc Capacitors Safety Standard Recognized, 900 Series, Radial Disc, Encapsulated, AH Type, X1 400 VAC/Y1 250 VAC (Industrial Grade) General Specifications/Performance Characteristics Dielectric/Temperature Characteristic: CH(NP0) SL Y5P Operating Temperature Range: Capacitance Change with Reference to +25C and 0 VDC Applied (TCC): Dissipation Factor (tan) at +25C1 Y5V +20%/-55% ~ +30%/-80% -25C to +125C 60 ppm/C -1,000 ~ +350 ppm/C 10% 4,000 VAC (60 5 seconds at 25C) Dielectric Withstanding Voltage Quality Factor (Q) Y5U 30 pF% and above: 1,000 Below 30 pF: 400 +(20xC)* See "Dissipation Factor" See "Quality Factor" 2.50% 2.50% 5.0% 10,000 M Minimum (500 VDC applied for 60 5 seconds @ 25C) Insulation Resistance (IR) Limit at +25C * C = Nominal capacitance 1 Capacitance and Dissipation Factor (DF) measured under the following conditions: CH(NP0) and SL: 1 MHz 100 kHz and 1.0 0.2 Vrms X5P, Y5U and Y5V: 1 kHz 50 Hz and 1.0 0.2 Vrms Note: When measuring capacitance, it is important to ensure the set voltage level is held constant. The HP4284 & Agilent E4980 have a feature known as Automatic Level Control (ALC). The ALC feature should be switched to "ON." Table 1 - Product Ordering Codes and Ratings Dimensions (mm) Dielectric/ Temp. Char. KEMET Part Number Capacitance CH (NP0) C901U209CUND(1)A(2) C901U309CUND(1)A(2) C901U409CUND(1)A(2) C901U509CUND(1)A(2) C901U609DUND(1)A(2) C901U709DUND(1)A(2) C901U809DUND(1)A(2) C901U909DUND(1)A(2) C901U100DUND(1)A(2) C901U120JUND(1)A(2) C911U150JUND(1)A(2) C911U180JUND(1)A(2) C911U200JUND(1)A(2) C911U220JUND(1)A(2) C911U240JUND(1)A(2) C911U270JUND(1)A(2) 2.0 pF 3.0 pF 4.0 pF 5.0 pF 6.0 pF 7.0 pF 8.0 pF 9.0 pF 10 pF 12 pF 15 pF 18 pF 20 pF 22 pF 24 pF 27 pF KEMET Part Number Capacitance Capacitance Tolerance Lead Spacing Body Body Lead Diameter Thickness Diameter (Maximum) (Maximum) Bulk Packaging Ammo Packaging 0.25 pF 7.0 0.5 pF 5% 5.0 0.5 0.1 10 mm Body Thickness (Maximum) Lead Diameter Lead Spacing 8.0 Capacitance Tolerance Body Diameter (Maximum) (1) To properly complete ordering code, insert the one-digit character code to reflect the required lead configuration: (See "Lead Configuration" section of this document, page 2, for further details.) A = Straight B = Vertical Kink C = Outside Kink (2) To properly complete ordering code, enter the four-digit numeric or alphanumeric "Packaging C-Spec Ordering Code." See "Dimensions" section of this document, page 2, for available options. (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 (864) 963-6300 * www.kemet.com C1067_X1_400 VAC_Y1_250 VAC * 11/14/2013 Roll Over for Order Info. 4 Radial Through-Hole Ceramic Disc Capacitors Safety Standard Recognized, 900 Series, Radial Disc, Encapsulated, AH Type, X1 400 VAC/Y1 250 VAC (Industrial Grade) Table 1 - Product Ordering Codes and Ratings cont'd Dimensions (mm) Dielectric/ Temp. Char. KEMET Part Number Capacitance SL C901U150JUSD(1)A(2) C901U180JUSD(1)A(2) C901U200JUSD(1)A(2) C901U220JUSD(1)A(2) C901U240JUSD(1)A(2) C901U270JUSD(1)A(2) C901U300JUSD(1)A(2) C901U330JUSD(1)A(2) C901U360JUSD(1)A(2) C901U390JUSD(1)A(2) C911U470JUSD(1)A(2) C911U500JUSD(1)A(2) C911U510JUSD(1)A(2) C911U560JUSD(1)A(2) C911U620JUSD(1)A(2) C921U680JUSD(1)A(2) C921U750JUSD(1)A(2) C921U820JUSD(1)A(2) C931U101JUSD(1)A(2) 15 pF 18 pF 20 pF 22 pF 24 pF 27 pF 30 pF 33 pF 36 pF 39 pF 47 pF 50 pF 51 pF 56 pF 62 pF 68 pF 75 pF 82 pF 100 pF C901U101KUYD(1)A(2) C901U151KUYD(1)A(2) C901U221KUYD(1)A(2) C901U331KUYD(1)A(2) C911U471KUYD(1)A(2) C921U561KUYD(1)A(2) C921U681KUYD(1)A(2) C941U102KUYD(1)A(2) 100 pF 150 pF 220 pF 330 pF 470 pF 560 pF 680 pF 1,000 pF Y5U C911U102MUWD(1)A(2) C921U152MUWD(1)A(2) C931U222MUWD(1)A(2) C951U332MUWD(1)A(2) C961U392MUWD(1)A(2) C971U472MUWD(1)A(2) 1,000 pF 1,500 pF 2,200 pF 3,300 pF 3,900 pF 4,700 pF Y5V C901U102MUVD(1)A(2) C911U152MUVD(1)A(2) C921U222MUVD(1)A(2) C941U332MUVD(1)A(2) C951U472MUVD(1)A(2) KEMET Part Number Y5P Capacitance Tolerance Lead Spacing Body Body Lead Diameter Thickness Diameter (Maximum) (Maximum) Bulk Packaging Ammo Packaging 7.0 5% 5.0 0.5 0.1 10 mm 5.0 0.5 0.1 10 mm 20% 8.0 9.0 10.0 12.0 13.0 14.0 5.0 0.5 0.1 10 mm 1,000 pF 1,500 pF 2,200 pF 3,300 pF 4,700 pF 20% 7.0 8.0 9.0 11.0 12.0 5.5 0.5 0.1 10 mm Capacitance Capacitance Tolerance Body Diameter (Maximum) Body Thickness (Maximum) Lead Diameter Lead Spacing 8.0 9.0 10.0 7.0 10% 8.0 9.0 11.0 (1) To properly complete ordering code, insert the one-digit character code to reflect the required lead configuration: (See "Lead Configuration" section of this document, page 2, for further details.) A = Straight B = Vertical Kink C = Outside Kink (2) To properly complete ordering code, enter the four-digit numeric or alphanumeric "Packaging C-Spec Ordering Code." See "Dimensions" section of this document, page 2, for available options. (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 (864) 963-6300 * www.kemet.com C1067_X1_400 VAC_Y1_250 VAC * 11/14/2013 Roll Over for Order Info. 5 Radial Through-Hole Ceramic Disc Capacitors Safety Standard Recognized, 900 Series, Radial Disc, Encapsulated, AH Type, X1 400 VAC/Y1 250 VAC (Industrial Grade) Table 2 - Performance & Reliability: Test Methods and Conditions Item Specification -25C to +125C Operating Temperature Range Dielectric Strength Between lead wires No failures Body Insulation No failures Insulation Resistance (IR) 10,000 M minimum Capacitance Within specified tolerance Dissipation Factor (DF) or Q Temperature Characteristics Temperature Characteristics Specification Y5P, Y5U DF 2.5% Y5V DF 5.0% NP0,SL 30 pF: Q 1,000 < 30 pF: Q 400 +(20 x C) C = Nominal capacitance Temperature Characteristics Capacitance Change Y5P Y5P, Y5U and Y5V: Capacitance is measured at 1 kHz 20% and 5 Vrms or less. (20 2C) NP0 and SL: Capacitance is measured at 1 MHz 20% and 1.0 0.2 Vrms (25C) A capacitance measurement is made at each step specified: Temperature 1 +20 2C Within 10% 2 -25 2C Y5U Within +22%/-56% 3 +20 2C Y5V Within ~+30%/-80% 4 +85 2C CH 0 60 ppm/C 5 +20 2C SL -1,000 ~+350 ppmC (+20C ~+85C) Lead wire or capacitor body shall not break. Bending Lead wire or capacitor body shall not break. Terminal Strength 1 The capacitor shall not be damaged when 4,000 VAC(rms) is applied between the lead wires for 60 seconds. The terminals (leads) of the capacitor shall be connected together. A metal foil is tightly wrapped around the body of the capacitor at a distance of about 3 to 4 mm from each terminal. The capacitor is then inserted into a container filled with metal balls approximately 1 mm in diameter. 4,000 VAC(rms) is applied for 60 seconds between the capacitor lead wires and metal balls. The insulation resistance shall be measured with 500 50 VDC applied after 60 5 seconds of charging. Step Tensile Solderability Test Method Lead wire should have a uniform coating of solder in the axial direction and over 3/4 of its circumference. Pre-treatment: Capacitor is stored at 85 2C for 1 hour and then placed at room condition1 for 24 2 hours before measurement. With the termination in its normal position, the specimen is held by its body in such a manner that the axis of the termination is vertical; a tensile force of 10 N is applied to the termination in the direction of its axis and acting in a direction away from the body of the specimen. With the termination in its normal position, the specimen is held by its body in such a manner that the axis of the termination is vertical; a mass force of 5 N is then suspended from the end of the termination. The body of the specimen is then inclined within a period of 2 to 3 seconds, through an angle of approximately 90 in the vertical plane and then resumed to its initial position over the same period of time; this operation constitutes one bend. One bend immediately followed by a second bend in the opposite direction. The lead wire of the capacitor is dipped into molten solder for 2 0.5 seconds. The depth of immersion is up to 1.5 mm (+5/-0 mm) from the root of lead wires. Solder Temperature: Lead free solder (Sn-3Ag - 0.5Cu) 245C 5C. "Room Condition" is defined as follows: Temperature: 15 ~ 35C/Humidity: 45 ~ 75%/Atmospheric Pressure: 86 ~ 106 kPa. (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 (864) 963-6300 * www.kemet.com C1067_X1_400 VAC_Y1_250 VAC * 11/14/2013 6 Radial Through-Hole Ceramic Disc Capacitors Safety Standard Recognized, 900 Series, Radial Disc, Encapsulated, AH Type, X1 400 VAC/Y1 250 VAC (Industrial Grade) Table 2 - Performance & Reliability: Test Methods and Conditions cont'd Item Soldering Effect (Non-Preheat) Specification Test Method Appearance No visual defect IR 1,000 M Dielectric Strength Per item 1 As shown in the figure below, the lead wires are immersed in molten solder up to 1.5 mm (+5/-0 mm) from the end of the epoxy meniscus (root of lead wire). Duration/Solder Temperature: 3.5 0.5 seconds/350C 10C or 10 1 seconds/260C 5C Capacitance Y5P, Y5U and Y5V: Within 10% SL, CH (NP0): Within 2.5% or 0.25 pF, whichever is larger. Appearance No visual defect IR 1,000 M Dielectric Strength Per item 1 Capacitance Y5P, Y5U and Y5V: Within 10% SL, CH (NP0): Within 2.5% or 0.25 pF, whichever is larger. Soldering Effect (Preheat) Appearance Capacitance Biased Humidity DF Q IR Dielectric Strength 1 No visual defect Temperature Characteristics Capacitance Change Y5P Within 10% Y5U Within 20% Y5V Within 30% SL CH (NP0) Within 2.5% or 0.25 pF, whichever is larger. Y5P and Y5U: 5.0% maximum Y5V: 7.5% maximum SL&CH(NP0): Less than 30 pF: Q 100+10xC/3 More than 30 pF: Q 200 C = Nominal capacitance Y5P, Y5V and Y5U: 3,000 M minimum SL and CH (NP0): 1,000 M minimum Pre-treatment: Capacitor is stored at 85C 2C for 1 hour and then placed at room condition1 for 24 2 hours before initial measurements. Post-treatment: Capacitor is stored for 1 to 2 hours at room condition1. Capacitor is stored at 120C +0/-5C for 60 +0/-5 seconds. Then, as shown in the figure below, the lead wires are immersed in molten solder up to 1.5 mm (+5/-0mm) from the end of the epoxy meniscus (root of lead wire). Duration/Solder Temperature: 7.5 +0/-1 seconds/260C 5C Pre-treatment: Capacitor is stored at 85C 2C for 1 hour and then placed at room condition1 for 24 2 hours before initial measurements. Post-treatment: Capacitor is stored for 1 to 2 hours at room condition1. Steady State Humidity: Load Humidity: 90 to 95% humidity at 40C 2C for 500 12 hours. 90 to 95% humidity at 40C 2C for 500 12 hours with full rated voltage applied. Post Treatment: Capacitor is stored for 1 to 2 hours at room condition1. Post Treatment: Capacitor is stored for 1 to 2 hours at room condition1. No failures "Room Condition" is defined as follows: Temperature: 15 ~ 35C/Humidity: 45 ~ 75%/Atmospheric Pressure: 86 ~ 106 kPa. (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 (864) 963-6300 * www.kemet.com C1067_X1_400 VAC_Y1_250 VAC * 11/14/2013 7 Radial Through-Hole Ceramic Disc Capacitors Safety Standard Recognized, 900 Series, Radial Disc, Encapsulated, AH Type, X1 400 VAC/Y1 250 VAC (Industrial Grade) Table 2 - Performance & Reliability: Test Methods and Conditions cont'd Specification No visual defect Appearance Capacitance Change IR Y5P, Y5V and Y5U: Within 20% SL and CH (NP0): Within 3 or 0.3 pF, whichever is larger. 3,000 M minimum SL and CH (NPO): 1,000 M minimum High Temperature Life Dielectric Strength No failures Test Method Impulse Voltage: Each individual capacitor is subjected to three 8 kv impulses prior to life testing. 0.9Vp Cx (uF) 0.01 0.1 UPR Vp Voltage Item UPP tr (uS) 1.2 1.5 td (uS) 46 47 0.5Vp tr td Time Capacitors are placed in a circulating air oven for a period of 1,000 hours. The air in the oven is maintained at a temperature of 125C 2C throughout the test. The capacitors are subjected to AC 425 Vrms. Each hour the voltage is increased to AC 1,000 Vrms for 0.1 seconds. The capacitor is exposed to a flame for 15 seconds and then removed for 15 seconds. This test is repeated for 5 cycles. The capacitor flame extinguishes as follows: Flame Test Cycle Time 1~4 30 seconds maximum 5 60 seconds maximum The capacitors are individually wrapped in at least one, but not more than two, complete layers of cheesecloth. They are then subjected to 20 discharges. The interval between successive discharges is 5 seconds. The VAC is maintained for 2 minutes after the last discharge. Active Flammability 1 The cheesecloth should not ignite. C1, 2 1 F 10% C3 0.033 F 5% 10 kV L1-4 1.5 Mh 20% 16A Rod core choke Cx Test capacitor R 100 2% VAC VR 5% Ct 3 F 5% 10 kV VR Rated Voltage F Fuse, Rated 10A Vt Voltage applied to Ct "Room Condition" is defined as follows: Temperature: 15 ~ 35C/Humidity: 45 ~ 75%/Atmospheric Pressure: 86 ~ 106 kPa. (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 (864) 963-6300 * www.kemet.com C1067_X1_400 VAC_Y1_250 VAC * 11/14/2013 8 Radial Through-Hole Ceramic Disc Capacitors Safety Standard Recognized, 900 Series, Radial Disc, Encapsulated, AH Type, X1 400 VAC/Y1 250 VAC (Industrial Grade) Table 2 - Performance & Reliability: Test Methods and Conditions cont'd Item Specification Test Method The capacitor under test is held into a flame and in a position which best promotes burning. Each specimen is exposed to the flame one time. Passive Flammability The burning time should not exceed 30 seconds. The tissue paper should not ignite. Time of exposure to flame: Length of flame: Gas burner length: Inside diameter: Outside diameter: Gas butane gas purity: Appearance Capacitance Temperature Cycle No visual defect Temperature Characteristics Capacitance Change SL, CH (NP0) Within 5% Y5P Within 10% Y5U, Y5V Within 20% SL, CH (NP0) 30 pF: Q 350 <30 pF: Q 275 +5/2C C = Nominal capacitance DF/Q IR Dielectric Strength 1 30 seconds 12 1 mm 35 mm minimum 0.5 0.1 mm 0.9 mm maximum 95% minimum Y5P DF 5% Y5U, Y5V DF 7.5% 3,000 M minimum SL and CH (NPO): 1,000 M minimum The capacitor is subjected to 5 temperature cycles. (Temperature Cycle) Step Temperature (C) Time (minutes) 1 -25 +0/-3 30 2 Room temperature 3 3 125 +3/-0 30 4 Room temperature 3 Pre-treatment: Capacitor shall be stored at 85 2 for 1 hour then placed at room condition1 for 24 2 hours. Post-treatment: Capacitor is stored for 1 to 2 hours at room condition1. No failures "Room Condition" is defined as follows: Temperature: 15 ~ 35C/Humidity: 45 ~ 75%/Atmospheric Pressure: 86 ~ 106 kPa. (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 (864) 963-6300 * www.kemet.com C1067_X1_400 VAC_Y1_250 VAC * 11/14/2013 9 Radial Through-Hole Ceramic Disc Capacitors Safety Standard Recognized, 900 Series, Radial Disc, Encapsulated, AH Type, X1 400 VAC/Y1 250 VAC (Industrial Grade) Soldering and Mounting Information Soldering: When soldering this product to a PCB/PWB, do not exceed the solder heat resistance specification of the capacitor. Subjecting this product to excessive heating could reflow the solder joint between the lead and ceramic element and/or may result in thermal shocks that can crack the ceramic element. When soldering these capacitors with a soldering iron, it should be performed under the following conditions: * Temperature of iron-tip: 400C maximum * Soldering iron wattage: 50 W maximum * Soldering time: 3.5 seconds maximum Cleaning (ultrasonic cleaning): To perform ultrasonic cleaning, observe the following conditions: * Rinse bath capacity: Output of 20 watts per liter or less * Rinsing time: 5 minute maximum * Do not vibrate the PCB/PWB directly * Excessive ultrasonic cleaning may lead to fatigue destruction of the lead wires Construction Reference Item Material 1 Encapsulation1 Epoxy resin, Pigment (Blue/UL 94 V-0) 2 Dielectric Material BaTiO3 3 Solder Sn 96.5, Ag 3, Cu 0.5 4 Electrodes Ag (Glass frit) Lead Wires Tinned copper clad steel wire (Sn Plating 100% 3-7 m) 5 The minimum thickness of the insulation coating (encapsulation) is 0.4 mm Note: Image is exaggerated in order to clearly identify all components of construction. 1 (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 (864) 963-6300 * www.kemet.com C1067_X1_400 VAC_Y1_250 VAC * 11/14/2013 10 Radial Through-Hole Ceramic Disc Capacitors Safety Standard Recognized, 900 Series, Radial Disc, Encapsulated, AH Type, X1 400 VAC/Y1 250 VAC (Industrial Grade) Capacitor Marking These capacitors shall be stamped or laser marked with KEMET's trademark, type designation, capacitor class, rated voltage, rated capacitance, and capacitance tolerance codes. In addition, all devices are marked with the recognized approval mark and a date/lot code for traceability. Marking will be supplied either on one side or both sides of the encapsulated capacitor body. All marking shall be legible to allow for clear identification of the component. Marking appears in legible contrast. Illustrated below is an example of the marking format and content. (Two sided marking is limited to capacitors with body diameters 8.0 mm.) AH222M X1:400V~ Y1:250V~ 2C12345 Location # Description Detail KEMET Trademark 1 Type Designation (2 characters) AH 1 Rated Capacitance (3 numeric characters) First two digits are the significant figures of capacitance. Third digit indicates the additional number of zeros. For example, 2,200 pF is identified as 222. (For values below 10 pF an "R" is used in place of the decimal point, e.g., 2R0 = 2.0 pF.) Capacitance Tolerance Code (1 character) C = 0.25 pF, D = 0.5 pF, J = 5%, K = 10%, M = 20% VDE & ENEC approval mark IEC 60384-14 3rd (2005) Capacitor Class and Rated Voltage X1: 400 V~ Y1: 250 V~ Date/Lot Code, e.g., 3C12345 Date/Lot Code 3 C 1 2345 Last digit of year, e.g., Manufacturing Location Code Manufacturing Month: Last 4 digits of lot no. 3 = 2013 1-9 = Jan - Sept A = October N = November D = December Packaging Quantities 1 Carrier Tape Quantity Packaging Type Loose (Bulk Bag) Ammo Pack N/A 500 pieces/box Bulk 500 pieces/bag N/A (25.4 mm Pitch1) For details regarding component pitch on carrier tape, see "Ammo Pack Taping Format" and "Ammo Pack Taping Specifications" sections of this document. (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 (864) 963-6300 * www.kemet.com C1067_X1_400 VAC_Y1_250 VAC * 11/14/2013 11 Radial Through-Hole Ceramic Disc Capacitors Safety Standard Recognized, 900 Series, Radial Disc, Encapsulated, AH Type, X1 400 VAC/Y1 250 VAC (Industrial Grade) Figure 1 - Ammo Pack Taping Format (10 mm Lead Spacing) Table 3 - Ammo Pack Taping Specifications Lead Spacing 10 mm Lead Style Straight Item Preformed1 Symbol Dimensions (mm) Lead Spacing F 10.0 1.0 Component Pitch P 25.4 2 Sprocket Hole Pitch P0 12.7 0.3 Sprocket Hole Center to Component Center P2 12.7 1.5 Sprocket Hole Center to Lead Center P1 7.7 1.5 Body Diameter D See "Product Ordering Codes and Ratings" section of this document. Component Alignment (side/side ) S 0 2.0 Carrier Tape Width W 18.0 +1.0/-0.5 Sprocket Hole Position W1 9.0 0.5 Height to Seating Plane (preformed leads ) H0 N/A 18.0 +2.0/-0 Height to Seating Plane (straight leads) H 20.0 +1.5/-1.0 N/A 2 1 2 Lead Protrusion 2.0 maximum Diameter of Sprocket Hole D0 4.0 0.2 Lead Diameter d 0.5 0.1 Carrier Tape Thickness t1 0.6 0.3 Total Thickness (Carrier Tape, Hold-Down Tape and Lead) t2 1.5 maximum h1 h2 2.0 maximum 2.0 maximum Cut Out Length L 11.0 maximum Hold-Down Tape Width W0 11.0 minimum Hold-Down Tape Position W2 Coating Extension on Leads (meniscus) e Body Thickness T 1.5 1.5 3.0 maximum for straight lead; not to exceed the bend for preformed1 lead configurations. See "Product Ordering Codes and Ratings" section of this document. Component Alignment (front/back ) Preformed (crimped) lead configurations include vertical kink and outside kink. See "Lead Configurations" and "Ordering Information" sections of this document for further details. 2 Also referred to as "lead length" in this document. 1 (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 (864) 963-6300 * www.kemet.com C1067_X1_400 VAC_Y1_250 VAC * 11/14/2013 12 Radial Through-Hole Ceramic Disc Capacitors Safety Standard Recognized, 900 Series, Radial Disc, Encapsulated, AH Type, X1 400 VAC/Y1 250 VAC (Industrial Grade) Application Notes: Storage and Operating Conditions: The insulating coating of these devices does not form an air and moisture-tight seal. Avoid exposure to moisture and do not use or store these devices in a corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt, or the like are present. Before cleaning, bonding or molding these devices, it is important to verify that your process does not affect product quality and performance. KEMET recommends testing and evaluating the performance of a cleaned, bonded or molded product prior to implementing and/or qualifying any of these processes. Store the capacitors where the temperature and relative humidity do not exceed 40 degrees Centigrade and 70% respectively. For optimum solderability, capacitor stock should be used promptly, preferably within 6 months of receipt. Working Voltage: Application voltage (Vp-p or Vo-p) must not exceed the voltage rating of the capacitor. Irregular voltages can be generated for a transient period of time when voltage is initially applied and/or removed from a circuit. It is important to choose a capacitor with a voltage rating greater than or equal to these irregular voltages. Operating Temperature and Self-Generating Heat: The surface temperature of a capacitor should be kept below the upper limit of its rated operating temperature range. Be sure to take into account the heat generated by the capacitor itself. When the capacitor is used in a high-frequency current, pulse current or similar current, it may self-generate heat due to dielectric loss. Temperature rise due to self-generated heating should not exceed 20C (while operated at an atmosphere temperature of 25C). Handling - Vibration and Impact: Do not expose these devices or their leads to excessive shock or vibration during use. FAILURE TO FOLLOW THE ABOVE CAUTIONS MAY RESULT, WORST CASE, IN A SHORT CIRCUIT AND CAUSE FUMING OR PARTIAL DISPERSION WHEN THE PRODUCT IS USED. (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 (864) 963-6300 * www.kemet.com C1067_X1_400 VAC_Y1_250 VAC * 11/14/2013 13 Radial Through-Hole Ceramic Disc Capacitors Safety Standard Recognized, 900 Series, Radial Disc, Encapsulated, AH Type, X1 400 VAC/Y1 250 VAC (Industrial Grade) KEMET Corporation World Headquarters Europe Asia Southern Europe Paris, France Tel: 33-1-4646-1006 Northeast Asia Hong Kong Tel: 852-2305-1168 Mailing Address: P.O. Box 5928 Greenville, SC 29606 Sasso Marconi, Italy Tel: 39-051-939111 Shenzhen, China Tel: 86-755-2518-1306 www.kemet.com Tel: 864-963-6300 Fax: 864-963-6521 Central Europe Landsberg, Germany Tel: 49-8191-3350800 Corporate Offices Fort Lauderdale, FL Tel: 954-766-2800 Kamen, Germany Tel: 49-2307-438110 North America Northern Europe Bishop's Stortford, United Kingdom Tel: 44-1279-460122 2835 KEMET Way Simpsonville, SC 29681 Southeast Lake Mary, FL Tel: 407-855-8886 Northeast Wilmington, MA Tel: 978-658-1663 Espoo, Finland Tel: 358-9-5406-5000 Beijing, China Tel: 86-10-5829-1711 Shanghai, China Tel: 86-21-6447-0707 Taipei, Taiwan Tel: 886-2-27528585 Southeast Asia Singapore Tel: 65-6586-1900 Penang, Malaysia Tel: 60-4-6430200 Bangalore, India Tel: 91-806-53-76817 Central Novi, MI Tel: 248-994-1030 West Milpitas, CA Tel: 408-433-9950 Mexico Guadalajara, Jalisco Tel: 52-33-3123-2141 Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of KEMET Electronics Corporation. (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 (864) 963-6300 * www.kemet.com C1067_X1_400 VAC_Y1_250 VAC * 11/14/2013 14 Radial Through-Hole Ceramic Disc Capacitors Safety Standard Recognized, 900 Series, Radial Disc, Encapsulated, AH Type, X1 400 VAC/Y1 250 VAC (Industrial Grade) Other KEMET Resources Tools Resource Location Configure A Part: CapEdge http://capacitoredge.kemet.com SPICE & FIT Software http://www.kemet.com/spice Search Our FAQs: KnowledgeEdge http://www.kemet.com/keask Electrolytic LifeCalculator http://www.kemet.com:8080/elc Product Information Resource Location Products Technical Resources (Including Soldering Techniques) RoHS Statement Quality Documents http://www.kemet.com/products http://www.kemet.com/technicalpapers http://www.kemet.com/rohs http://www.kemet.com/qualitydocuments Product Request Resource Location Sample Request Engineering Kit Request http://www.kemet.com/sample http://www.kemet.com/kits Contact Resource Location Website Contact Us Investor Relations www.kemet.com http://www.kemet.com/contact http://www.kemet.com/ir Call Us 1-877-MyKEMET Twitter http://twitter.com/kemetcapacitors Disclaimer All product specifications, statements, information and data (collectively, the "Information") in this datasheet are subject to change. The customer is responsible for checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on KEMET Electronics Corporation's ("KEMET") knowledge of typical operating conditions for such applications, but are not intended to constitute - and KEMET specifically disclaims - any warranty concerning suitability for a specific customer application or use. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET's products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product-related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 (864) 963-6300 * www.kemet.com C1067_X1_400 VAC_Y1_250 VAC * 11/14/2013 15