SPECIFICATION
MODEL PLP-60-12 PLP-60-24 PLP-60-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP TIME
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (max.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT Note.5
SHORT CIRCUIT
OVER VOLTAGE
12V 24V 48V
18 ~ 24V 36 ~ 48V
5A
0 ~ 5A
2.5A
0 ~ 2.5A
1.3A
0 ~ 1.3A
60W 60W 62.4W
4.5Vp-p 4.5Vp-p
1.875 ~ 2.5A
4.8Vp-p
0.975 ~ 1.3A
±10%
±3.0%
±5.0%
1000ms / 230VAC 2000ms / 115VAC at full load
90 ~ 264VAC
47 ~ 63Hz
PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC≧
84% 88% 89%
15 ~ 18V 28 ~ 35V 57 ~ 63V
0.8A/115VAC 0.4A/230VAC
<0.75mA / 240VAC
Protection type : Constant current limiting, recovers automatically after fault condition is removed
-30 ~ +70 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
583.3K hrs min. MIL-HDBK-217F (25 )℃
101.6*50.8*29.6mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. lease refer to "DRIVING METHODS OF LED MODULE".
P
6. Heat sink HS1,HS2 can not be shorted.
7. Heat sink HS1 must have safety isolation distance with system case.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
0.16Kg; 96pcs/16.4Kg/0.89CUFT
•Universal AC input / Full range
•Protections: Short circuit / Over current / Over voltage
•Built-in active PFC function
•Cooling by free air convection
•Class 2 power unit
•Output current level adjustable
•100% full load burn-in test
•High reliability
•Suitable for built-in applications of LED lighting
•2 years warranty
■Features :
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
Compliance to EN55015, EN61000-3-2 Class C( 75% load); EN61000-3-3≧
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61547, light industry level, criteria A
3.75 ~ 5A
100 ~ 110%
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Hiccup mode, recovers automatically after fault condition is removed
60W Single Output LED Power Supply PLP-60 series
File Name:PLP-60-SPEC 2013-11-27
9 ~ 12V
..
EMC IMMUNITY
EMC EMISSION
( for 48V only) ( except for 48V )
UL8750, TUV EN61347-1, EN61347-2-13, CSAC22.2 No. 250.0-08(except for 48V) approved ; design refer to UL60950-1
COLD START 35A(t =55 s measured at 50% I ) at 230VAC
width peak
μ
CONSTANT CURRENT REGION
Note.5