SPECIFICATION
MODEL PLP-60-12 PLP-60-24 PLP-60-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP TIME
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (max.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT Note.5
SHORT CIRCUIT
OVER VOLTAGE
12V 24V 48V
18 ~ 24V 36 ~ 48V
5A
0 ~ 5A
2.5A
0 ~ 2.5A
1.3A
0 ~ 1.3A
60W 60W 62.4W
4.5Vp-p 4.5Vp-p
1.875 ~ 2.5A
4.8Vp-p
0.975 ~ 1.3A
±10%
±3.0%
±5.0%
1000ms / 230VAC 2000ms / 115VAC at full load
90 ~ 264VAC
47 ~ 63Hz
PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC
84% 88% 89%
15 ~ 18V 28 ~ 35V 57 ~ 63V
0.8A/115VAC 0.4A/230VAC
<0.75mA / 240VAC
Protection type : Constant current limiting, recovers automatically after fault condition is removed
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
583.3K hrs min. MIL-HDBK-217F (25 )
101.6*50.8*29.6mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. lease refer to "DRIVING METHODS OF LED MODULE".
P
6. Heat sink HS1,HS2 can not be shorted.
7. Heat sink HS1 must have safety isolation distance with system case.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
0.16Kg; 96pcs/16.4Kg/0.89CUFT
Universal AC input / Full range
Protections: Short circuit / Over current / Over voltage
Built-in active PFC function
Cooling by free air convection
Class 2 power unit
Output current level adjustable
100% full load burn-in test
High reliability
Suitable for built-in applications of LED lighting
2 years warranty
Features :
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C( 75% load); EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61547, light industry level, criteria A
3.75 ~ 5A
100 ~ 110%
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Hiccup mode, recovers automatically after fault condition is removed
60W Single Output LED Power Supply PLP-60 series
File Name:PLP-60-SPEC 2013-11-27
9 ~ 12V
..
EMC IMMUNITY
EMC EMISSION
( for 48V only) ( except for 48V )
UL8750, TUV EN61347-1, EN61347-2-13, CSAC22.2 No. 250.0-08(except for 48V) approved ; design refer to UL60950-1
COLD START 35A(t =55 s measured at 50% I ) at 230VAC
width peak
μ
CONSTANT CURRENT REGION
Note.5
Mechanical Specification
File Name:PLP-60-SPEC 2013-11-27
Unit:mm
Derating Curve Static Characteristics
AMBIENT TEMPERATURE ( )
LOAD (%)
-30 -25 -5 0 20 40 50 55 60 70
20
40
60
80
100
INPUT VOLTAGE (V) 60Hz
90 100 125 135 145 155 165 175 180 200 230 264
100
90
80
70
60
50
40
LOAD (%)
(HORIZONTAL)
fosc : 90KHz(115VAC)
120KHz(230VAC)
Block Diagram
50
AC Input Connector (CN1) : JST B3P-VH or equivalent
DC Output Connector (CN2) : JST B2P-VH or equivalent
Pin No.
Pin No.1
1
32
2
Assignment
AssignmentAC/L
+V
AC/N -V
No Pin
Mating Housing
Mating Housing
JST VHR
JST VHR
or equivalent
or equivalent
Terminal
Terminal
JST SVH-21T-P1.1
JST SVH-21T-P1.1
or equivalent
or equivalent
12V
Others
: Grounding required
DETECTION
PWM & PFC
CIRCUIT
O.L.P.
EMI FILTER
RECTIFIERS
POWER
SWITCHING FILTER
&
RECTIFIERS +V
-V
I/P
FG
CONTROL
O.V.P.
&
O.C.P.
CN2
CN1
FS1
1
2
1
2
3
3.175
3.175
95.25
101.6
.
.
HS2HS1
SVR1
PLP-60 series
60W Single Output LED Power Supply
29.6
3max.
4- 3.2ψ
44.45
50.8
1.HS1,HS2 can not be shorted.
2.HS1 must have safety isolation distance
with system case.
60
62
64
66
68
70
72
74
76
78
80
82
84
86
88
90
92
94
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
230V
115V
0.78
0.80
0.82
0.84
0.86
0.88
0.90
0.92
0.94
0.96
0.98
1.00
50% 60% 70% 80% 90% 100%
230V
115V
PLP-60 series possess superior working efficiency that up to 89% can be reached in field applications.
EFFICIENCY (%)
LOAD
Power Factor Characteristic
EFFICIENCY vs LOAD (48V Model)
Constant Current Mode
PF
LOAD
DRIVING METHODS OF LED MODULE
(60W)
This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.
Typical LED power supply I-V curve
Vo(%)
100
75
50 100
(max.)
Io (%)
Constant
Current area
Hiccup
Protection
In the constant current region, the highest voltage at the output of the driver
depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL.
File Name:PLP-60-SPEC 2013-11-27
PLP-60 series
60W Single Output LED Power Supply