INTEGRATED CIRCUITS DIVISION
www.ixysic.com
2R04
PAA190
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Parameter Ratings Units
Blocking Voltage 400 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1150 mW
Total Power Dissipation 2800 mW
Isolation Voltage, Input to Output 5000 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Electrical Characteristics @ 25ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current *
Continuous, AC/DC Configuration - IL- - 150 mArms / mADC
Peak t=10ms ILPK - - ±400 mAP
On-Resistance, AC/DC Configuration IL=150mA RON --22
Off-State Leakage Current VL=400VPILEAK --1 µA
Switching Speeds
Turn-On IF=5mA, VL=10V ton --1 ms
Turn-Off toff - - 0.5
Output Capacitance VL=50V, f=1MHz COUT -25- pF
Input Characteristics
Input Control Current to Activate IL=150mA IF--5 mA
Input Control Current to Deactivate - IF0.2 0.7 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR- - 10 µA
Common Characteristics
Capacitance, Input to Output - CI/O -3- pF
*NOTE: If both poles operate simultaneously, then load current must be derated in order not to exceed the package power dissipation value.